"Home Inspections That Discover" Property Inspection Report Linzi Liu Prepared for: Home Buyer West Ruby Hill Dr, Pleasanton 01/27/2022 00/00/2022 Report #8537 #3694 Inspected by Glenn Stewart of The House Whisperer LLC 1.800.662.8589 The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 1

Table of Contents CONDITION 3 GROUNDS 5 EXTERIOR 7 FOUNDATION - BASEMENT 9 ROOF SYSTEM 9 ATTIC 12 PLUMBING 13 ELECTRICAL 16 GARAGE - CARPORT 19 INTERIOR 21 HEATING & AIR CONDITIONING 25 KITCHEN - APPLIANCES 27 LAUNDRY 29 BATHROOMS 31 The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 2

CONDITION PLEASE READ. This inspection report is the property of the Client (the person who paid for the inspection report). Reported property conditions in this report should be carefully considered by the Client and reviewed with a real estate agent, as appropriate. The report of a condition is often based on the experience of the inspector using visual clues, it should be understood that more extensive problems may be present, which can be more costly to resolve than simply correcting the reported visible condition. The inspection and report are not intended to be technically exhaustive, or to imply that every component or instance of similar deficiencies was inspected, or that every possible defect was discovered. Unexpected repairs should be still be anticipated. CLIENT: 1.1 PRESENT: Buyer, Buyer's buyer's Agent, agent assistant, property inspector. Property Inspector. 1.2 CLIENT NAME: Home Buyer. 1.3 INSPECTION DATE: 12/27/2021 1:00 PM. PM. 00/00/2022 1:00 WEATHER: 1.4 WEATHER: Rain. 1.5 APPROX TEMPERATURE: 50-60 degrees. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 3

ABOUT BLDG: 1.6 BUILDING TYPE: This property is listed as a single family residence. 1.7 CRAWL or SLAB This building is built on a concrete slab on grade foundation (no crawlspace). 1.8 ABOUT The inspected house, townhouse or condo was viewed from the street with location references as being at the front, rear, left, or right. 1.9 UTILITIES: The gas, water and electrical utilities were turned on at the time of inspection. 1.10 OCCUPIED? The house was occupied at the time of inspection. NOTES: 1.11 NOTES The free standing, exterior masonry BBQ firepit or the stainless steel BBQ was not inspected and is not included as part of this report. There was a water softener system present at the property. Inspection of water treatment systems and/or water quality is beyond the scope of our services. Mold disclaimer: crawlspace moisture, poor exterior drainage, condensation, plumbing pipe leaks, exterior gaps, laundry hoses, roof and faucet leaks, water supply pipe leaks and other sources of moisture in a building may be a source for mold growth. It is beyond the scope of this inspection to determine, if mold is present in this building. If we do see evidence of bio-growth, it'll be commented on in this report. The automatic fire suppression system (ceiling sprinklers) was not inspected and is beyond the scope of this inspection. There is an installed central vacuum system. Inspection of the central vacuum system is beyond the scope of our services. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 4

REPORT LIMITATIONS: 1.12 LIMITATIONS There are one or more places in a residential house that are inaccessible or the inspector can't see to comment on. the buried sewer lateral pipe between the house and the street sewer line, inside of walls, under carpets, all areas of an attic. where there may be issues in need of attention discovered during remodeling or updating a house. GROUNDS This report doesn't include information on soil types, soil conditions, erosion, hillsides or site stability. If there are concerns, consult with a geo-technical engineer or soils engineer prior to taking possession of the property. DRIVEWAY: 2.1 CONDITION: The driveway within 20 feet of the building was in good condition. WALKWAYS: 2.2 CONDITION S3: The front entry walkway was in good condition. PATIO: 2.3 CONDITION: The patio is in good condition. PORCH-PATIO COVER: 2.4 DISCLAIMER: Free standing structures (not attached to the house) such as patio covers, arbors, trellises or pergolas are considered accessory structures and are excluded from this report. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 5

FENCES & GATES: 2.5 CONDITION: The metal property fence in the near vicinity of the house was in good condition. A section of the AC unit fence was wobbly and/or had a noticeable lean. Other fence sections may have a similar condition. Fences between properties are considered 'good neighbor' fences and the cost of repair is usually shared. GRADING AND DRAINAGE: 2.6 GRADE: The perimeter grade (slope) within 6 feet of the foundation was in good condition. 2.7 DRAINAGE: The property has installed surface drainage collection grates around the house. We recommend removing all debris, landscaping materials, grass that may accumulate on top of the grates. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 6

LANDSCAPING: 2.8 Sprinklers The inspection of any irrigation system (sprinklers) is beyond the scope of our inspection. EXTERIOR Any exterior building siding that was hidden from view by stored vehicles, stacked building materials, vegetation, sheds, air conditioning equipment, etc. at the time of inspection was not inspected. There may be siding discrepancies not identified. WALLS: 3.1 STUCCO: The stucco siding was in good condition. All stucco is susceptible to shrinkage cracks due to application or weather conditions and/or stress cracks due to seismic activity or building settlement. The bottom edge of the rear left stucco siding was in contact or near-contact with the soil. There's a potential for wood-destroying pest entry or water intrusion at the stucco siding bottom edge (weep screed). We recommend pulling back the soil to reveal 3-4" of the foundation and a review of a current structural pest report. 3.2 BRICK CONDITION: The masonry brick siding was in good condition. TRIM: 3.3 WINDOW TRIM: The paint has weathered, peeled and/or blistered at one or more exterior window wood trim pieces. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 7

EAVES 3.4 EAVE - RAFTER: The roof eaves or soffit panels visually appear to be in good condition. Since we don't carry equipment to probe wood, we recommend review of a current structural pest report for possible pest or dry rot conditions. There was evidence of birds nesting or roosting at the right side. Birds can be a nuisance as well as create unsanitary conditions and cause damage to the building. We recommend cleaning up the bird mess and a review by a Bird Control specialist. WINDOWS EXTERIOR: 3.5 CONDITION: One or more window screens were missing around the building. We recommend installing screens to keep out bugs, birds and pests prior to taking possession of the house. The house windows as viewed from the exterior are in good condition. There are one or more gaps or water damage at the exterior left side by the garage and an exterior rear, right window (master bedroom) faux trim. We recommend caulking gaps around windows to prevent moisture intrusion and a review of a current structural pest report. Contact a licensed contractor. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 8

FOUNDATION - BASEMENT Our inspection of the building foundation is a visual examination of the exposed and readily accessible portions of a foundation. Foundations are examined for visible surface defects, large cracks, deterioration and general condition. FOUNDATION: 4.1 TYPE: Concrete slab foundation (no crawlspace). 4.2 SLAB CONDITION: There were no obvious defects in the visible exterior perimeter edge of the concrete foundation slab. The surface of the interior concrete slab is rarely visible due to installed floor coverings. Sometimes when the carpeting and padding is changed, there can be visible shrinkage or settlement cracks in the concrete slab foundation. No readily visible problems were noted in the concrete slab foundation at the time of inspection. ROOF SYSTEM The inspection of a roof is our opinion of the general condition of the roofing material and roof penetrations (plumbing vents, exhaust vents, skylights, chimneys, etc). The home inspector cannot and does not offer an opinion or warranty as to whether there's water leakage during a rain; there will be future water leakage; or that the roof was installed per manufacturers' requirements. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 9

ROOF: 5.1 ROOF TYPE: The house roof is installed with flat concrete tiles. 5.2 INSPECTED BY: Due to the rain and steep pitch of some roof areas, the lower level roof was examined using a ladder and by viewing the roof from the ground. The upper roof was scanned with binoculars. This is a limited inspection and there may be reportable conditions. We recommend a no-charge review of the roof by the Roof Doctors 800-913-1180. Only a home buyer or a home seller, not a realtor or The House Whisperer office can schedule a roof inspection by the Roof Doctors (they recently changed their policy). VENT CAPS: 5.3 CONDITION: There is a loose exhaust vent at the upper middle roof, a possible water intrusion point. We recommend review by a licensed roofing contractor prior to taking possession of the house. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 10

GUTTERS & DOWNSPOUTS: 5.4 GUTTER TYPE & CONDITION: There is an installed rain gutter system that's in good condition. 5.5 DOWNSPOUT CONDITION: The roof gutter downspouts terminate into an underground water drainage collection system. The inspection of underground drainage systems is outside the scope of our inspection. CHIMNEY 1: 5.6 LOCATION: A chimney is located at the right side of building. 5.7 MATERIAL: Stucco chase (chimney) with stainless steel flue. 5.8 OK: The exterior chimney appears to be in good condition. 5.9 SCREEN & CAP: A spark arrestor-rain cap assembly was installed above the chimney flue(s) to prevent the escape of hot embers or rain entry and was in serviceable condition. CHIMNEY 2: 5.10 LOCATION: A chimney is located at the left side of building. 5.11 MATERIAL: Stucco chase (chimney) with stainless steel flue. 5.12 OK: The exterior chimney appears to be in good condition. 5.13 SCREEN & CAP: A spark arrestor-rain cap assembly was installed above the chimney flue(s) to prevent the escape of hot embers or rain entry and was in serviceable condition. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 11

ATTIC We use a flashlight at the attic access opening or from an approved equipment service deck to conduct a very limited inspection of the visible areas of the attic. The following conditions can block visual inspection and entry into the attic space: insulation concealment, low roof clearance, roof support framing, roof replacement debris, rodent infestation, chimneys, flues, exhaust ducts, heating/cooling ducts, plumbing pipes, bathroom vent ducts, stored personal items, excessive temperature, and/or exposed or covered by insulation Knob & Tube wiring. Evidence of termites, insects, bees, hornets, wasps, squirrels, rats, mice, squirrels, birds, bats, nests, and/or other life activity may not have been observed or smelled. We highly recommend asking the seller to comment prior to the close of the contingency, if they know of any unwanted conditions in the attic. ATTIC 6.1 ACCESS The visible sections of the attic were viewed from a couple of different access openings only. If the attic is entered by an individual willing to take on the liability of possible damage to the ceiling below and possible health and safety risks; there's the possibility of discovering a condition that wasn't visible when the inspector viewed the attic from the attic access opening. 6.2 FRAMING: The visible attic/roof framing was in good condition. 6.3 VENTILATION: The visible attic vent screens are in good condition. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 12

6.4 DUCTS: The visible attic heating/cooling ducts were in good condition. 6.5 INSULATION CONDITION: The visible attic insulation is in good condition. The insulation is installed backwards with the foil or paper barrier visible. The vapor barrier side of the insulation batt should be installed towards the heated side of the home for best performance. PLUMBING We inspect readily accessible and visible: 1. Water supply piping 2. Drain, waste, and vent piping 3. Faucets and fixtures 4. Fuel gas piping 5. Water heaters 6. Functional flow and functional drainage The inspector does not measure water pressure to the house, but does check functional water flow. Contact the local water utility company to measure water pressure from the street. Per State Bill 407, water conserving plumbing fixtures (toilets, sink fixtures, shower heads) are required when an existing property was built on or before Jan 1994. and is undergoing additions, alterations or improvements, after Jan 1, 2017. Home sellers are required to disclose to buyers whether there are any non-compliant plumbing fixtures on the property. WATER AND SHUT OFF LOCATION: 7.1 LOCATION - MATERIAL: The homeowner water shutoff valve was located at the right side of the two car garage. 7.2 CONDITION: The main water shutoff valve was in good condition. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 13

GAS & SHUT OFF LOCATION: 7.3 LOCATION: The natural gas meter was located on left side of the building. 7.4 CONDITION: The gas service meter was in good condition. 7.5 CONDITION 3 There was no gas valve shutoff wrench at the gas meter. We recommend providing a gas shutoff wrench, so that the gas flow can be shut off manually in an emergency. No automatic gas shutoff valve was installed at the gas service meter. Some counties, local building departments and home owner insurance companies require this seismic safety device at the gas meter. Check to see if this is a requirement for this property prior to taking possession of the house. Contact a licensed plumber to install an automatic gas shutoff valve. The gas service meter plumbing pipe surfaces are beginning to rust. Contact PG&E for a no charge review of the gas system and gas-fired appliances. HOSE FAUCETS: 7.6 CONDITION: The accessible exterior hose bibs (water faucets) were working at the time of our inspection. Faucets not attached to the home, are not tested. SUPPLY PLUMBING: 7.7 MATERIAL: The visible water supply pipes were copper. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 14

7.8 CONDITION: The visible water supply plumbing pipes were in good condition. WASTE PLUMBING: 7.9 MATERIAL: ABS (acronym for acrylonitrile, butadiene), a rigid black plastic pipe, 7.10 CONDITION: The visible portions of the plumbing drain and waste pipes were in good condition. 7.11 SEWER LATERAL: A sewer lateral pipe cleanout is located at the right of the house. WATER HEATER 1: 7.12 LOCATION: A water heater is located in the garage. 7.13 TYPE: The water heater uses natural gas to heat the water. 7.14 AGE/CAPACITY Water heater was manufactured in 2015 and is a 75 gallon size. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 15

7.15 STRAPS: Ok The water heater was strapped, braced, or anchored per State guidelines to resist toppling during an earthquake. 7.16 PLUMBING: The water supply/return plumbing at the water heater was in good condition. 7.17 RELIEF VALVE: The water heater safety valve discharge pipe terminates next to the water heater. This doesn't meet requirements of terminating at the exterior or to an approved receptor. This is a personal safety concern, if the valve opens and someone is nearby. We recommend review by a licensed plumber prior to taking possession of the house. 7.18 FLUE OK The water heater exhaust flue was in good condition. ELECTRICAL We are not electricians, nor are we building code compliance inspectors. The inspection of the electrical system should be considered a 'top-level' general review of observed electrical conditions at time of inspection. If electrical panels are accessible and considered safe to open, we may do so to check interior panel conditions. We do not evaluate every instance of a component (electrical outlet, switch, light, circuit breaker, wire, circuit, etc), but rather check a representative sample of each component, as a means of assessing the general status of electrical conditions. Buildings that have a Bulldog, Pushmatic, Zinsco, Sylvania Zinsco or Federal Pacific Electric electrical panel should have it evaluated by a licensed electrician, as these older types of panels and breakers are sometimes obsolete, have safety concerns, or are difficult to service The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 16

SERVICE: 8.1 SERVICE: The incoming electrical service cables were installed underground between an electrical service vault and the building. ELECTRICAL MAIN PANEL: 8.2 LOCATION: The main electrical panel is located at the left exterior of the building. 8.3 ELECTRICAL CAPACITY: The main electrical panel has an installed 200 amp (amperes) electrical circuit breaker for turning the electricity to the house On/Off. 8.4 CONDITION OK: The main electrical panel was in good condition at the time of our inspection. SUB-PANEL 1: 8.5 LOCATION: Garage. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 17

8.6 TYPE: The electrical subpanel uses circuit breakers to turn the electrical power on or off. 8.7 PANEL CONDITION Ok: The electrical subpanel circuit breakers were labeled and the panel was in good condition. INTERIOR WIRING: 8.8 WHAT IS GFCI? A GFCI (ground fault circuit interrupter) electrical wall outlet is a special type of electrical outlet designed to protect people from electrical shock in bathrooms, kitchens, garages, house exterior, pools, etc where there's water. 8.9 GFCI CONDITION: The installed GFCI electrical wall outlets (outlets with test/ reset buttons) were tested and were in operable condition. 8.10 OUTLETS OK: A sample of the readily accessible electrical wall outlets (not blocked by furniture) were tested and the sampled outlets were found to be in operable condition. 8.11 SWITCHES: A representative number of electrical wall switches were tested and the sampled electrical switches were found to be in good condition. Some of the wall switches were found to be without an obvious function. 8.12 LOW VOLTAGE The evaluation of low-voltage wiring in the building or on the property including, but not necessarily limited to telephone, computer, security systems, data transfer lines, TV antenna and cables, security alarm, intercom, doorbell, low voltage outdoor lighting, and stereo wiring is beyond the scope of this inspection. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 18

GARAGE - CARPORT TYPE: 9.1 TYPE: There is a three car split garage. FLOOR: 9.2 CONDITION: The visible garage floors were in good condition. GARAGE DOORS: 9.3 CONDITION: The 2 car door was worn, water damaged, weathered, and/or there was peeling paint. We recommend review by a qualified garage door specialist, as the door may have to be replaced. Moisture stains were noted on the inside of the wood framed garage vehicle door. This is a typical condition, but suggests that the garage door panels are in need of painting and/or sealing. Review a current structural (termite) pest report. 9.4 OPENER CONDITION: If the home buyer doesn't get two garage door remote openers, the buyer should consider purchasing new universal remote controls for the garage door(s) for security, not knowing where one or more of the original two garage door remote controllers may be. Both of the garage doors opener wall switches had to be held down in order to fully close both of the garage doors. Both garage door openers are in need of service. We recommend review by a garage door specialist prior to taking possession of the house. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 19

FIRE DOOR: 9.5 CONDITION: The passage doors between the garage and the habitable house were in operable condition (self-closing and latching). FIREWALL: 9.6 WALL CONDITION: A cooling wall unit for the wine closet was installed in the single car garage firewall. This doesn't meet building requirements and is an entry point for fumes, fire, smoke and vapors and is a health safety concern. We highly recommend review by a licensed contractor prior to taking possession of the house. CEILING: 9.7 CEILING CONDITION: The garage ceilings were inspected for water stains and none were noted at the time of inspection. GARAGE NOTES: 9.8 CONDITION: There were rodent droppings in the garage. This is a health safety concern. We recommend cleaning up the rodent activity and installing weather seals around doors, repairing any damaged ventilation screens and sealing any openings from the exterior. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 20

GARAGE ATTIC 9.9 ACCESS The visible sections of the garage attic was viewed from the access opening only. 9.10 ISSUES: There was excessive clothes dryer lint in the single car garage attic. See additional comment under the Laundry section. INTERIOR Wall, floor and ceiling surfaces that are visible and accessible are inspected. We do not move furniture or personal items. The condition of walls behind wall coverings, wall hangings, stored items, drapes and/or furniture cannot be judged. As a general rule, cosmetic wall deficiencies (hairline cracks, dents, scuff marks, damaged paint) are considered normal wear and tear and are not reported. WINDOWS: 10.1 TYPE: Dual pane windows are installed. 10.2 DISCLAIMER This property has dual pane windows. When there's a visible fogginess, streaking or condensation at a dual pane window. it's an indication of a failed perimeter window seal due to weather conditions. We make every effort to identify failed window seals; but make no guarantee that all windows with failed seals have been identified in this building. 10.3 CONDITION: The accessible windows that the inspector was able to walk up to were in operable condition. Windows blocked by furniture, blinds, stored items, high on a wall or on other side of a bathtub were not inspected. We recommend a review of all windows at the final walk through inspection. FRONT DOOR: 10.4 CONDITION: The door latch for the front entry door is broken per the realtor assistant, as stated to the inspector. We recommend review of the front door latch by a qualified door specialist prior to taking possession of the house. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 21

INTERIOR DOORS: 10.5 CONDITION: The interior doors were in operable condition. CLOSET DOORS: 10.6 CONDITION: The closet doors were in good condition at the time of our inspection. FIREPLACE: 10.7 FIREPLACES: The living room fireplace is installed with decorative gas logs, glass beads or sand and is not a wood burning fireplace. We do not turn on the gas valve and light decorative gas logs. We recommend inspection of the gas log fireplace and flue by a licensed fireplace specialist prior to taking possession of the house. The inspector was unable to inspect the family room fireplace due to TV sitting on the hearth in front of the firebox. We recommend review of the fireplace and chimney by a license chimney specialist prior to taking possession of the house. 10.8 DAMPER CONDITION: The living room fireplace has a gas valve. It is now a requirement to have a C-clamp installed on the fireplace flue damper plate edge. In the event of a leaking gas valve, the C-clamp prevents gas from entering the living space by keeping the damper plate above the firebox partially open. This is a potential health/safety concern. We recommend review by a licensed fireplace specialist. 10.9 HEARTH CONDITION: The living room fireplace hearth extension was in good condition at the time of our inspection. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 22

WALLS: 10.10 WALL CONDITION: Not all wall surfaces were viewed as some wall sections were hidden by furniture, stored items and drapes. Conditions in need of repair may be discovered. Any observed hairline cracks in the interior walls are 100% cosmetic and not structurally threatening. CEILINGS: 10.11 CEILING CONDITION: The ceilings were in good condition. Any observed hairline cracks are considered a cosmetic condition and are not structurally threatening. Repair is optional. FLOORS: 10.12 FLOOR CONDITION: The visible flooring materials (excludes flooring covered by area rugs, furniture and personal items) were in good condition at the time of our inspection. 10.13 CARPET CONDITION: Loose carpeting was noted in one or more carpeted rooms, where the carpet backing has stretched and created a raised section of carpet. a potential tripping concern. We recommend review by a qualified flooring specialist. SMOKE DETECTOR 10.14 READ ME In California, smoke detectors are required in: 1) bedrooms 2) bedroom hallways 3) each story of the house, finished attics, basements, at the top of a stairway on the ceiling, and at bottom of basement stairs on ceiling. Follow manufacturers installation instructions. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 23

10.15 COMMENTS S1: Smoke detectors were installed in the downstairs bedrooms and in the downstairs hallway; but no smoke detector was observed upstairs outside of the bedrooms. This is a fire safety concern, a liability and doesn't meet building requirements. We highly recommend having the required smoke detectors installed. A battery was missing from one or more left side bedroom smoke detectors. This is a concern, as a hard-wired detectors will not sound during a power outage; and a battery-operated smoke detectors will not respond to smoke. We highly recommend installing replacement batteries in all of the smoke detectors. CO DETECTOR 10.16 CONDITION: Carbon monoxide (CO) detectors were installed outside the right side bedroom area and upstairs, but not outside the left side bedroom area. This is a health safety concern and a home owner's liability. We highly recommend installing one more (1x) CO detector in this left side bedroom area hallway prior to taking possession of the house. STAIRS & HANDRAILS: 10.17 CONDITION: The interior stairs, the handrail (and guard railings) were in good condition. EXTERIOR DOORS: 10.18 CONDITION: One or more exterior house doors were inspected and found to be in operable condition. The House Whisperer This report is the exclusive property of the inspection company and Client who paid for the report. Use of the report by others is prohibited. 24

HEATING & AIR CONDITIONING Our inspection of the heating and/or cooling system includes an examination of the readily accessible and visible major components: heat pumps, wall heater, heating furnace, AC condenser, AC evaporator coil, boilers, etc., to determine defects, excessive wear, and general state of repair. We activate the wall thermostat and check for an appropriate response. We don't remove equipment panels. We don't check the performance of the HVAC system. We recommend periodic inspections of the equipment by a licensed HVAC service technician. AIR CONDITIONING: 11.1 TYPE: This property is installed with a central air conditioning system consisting of an evaporator coi

Property Inspection Report Prepared for: Linzi Liu West Ruby Hill Dr, Pleasanton 01/27/2022 Report #3694 Inspected by Glenn Stewart of The House Whisperer LLC 1.800.662.8589 Prepared for: Home Buyer 00/00/2022 Report #8537

Related Documents:

5. The Property Inspection Report a. Purpose of the property inspection As per New Zealand Standard 4306:2005, section 2.1.2: the purpose of the property inspection is to identify significant defects visible at the time of the inspection. b. The property report Section 3.2 of NZS 4306:2005 states that the Property R eport shall include the .

INSPECTION INFORMATION 1.1 SUBJECT PROPERTY Commercial building xxxxxx Glendale, California 1.2 INSPECTION DATE Thursday February 25, 2016 1.3 INSPECTION TIME 2:30 p.m. . This inspection and report has been performed in accordance with the California Real Estate Inspection Association (CREIA) Standards of Practice which is incorporated herein .

Property Inspection Report Charlie and Mary Sample Residential Inspection Inspection Date: 11/20/06 Prepared for: Charlie and Mary Sample Report number: 60022011 Inspector: John P. Vagliardo Vagliardo Inspection Service Office 607-433-1630 Fax 607-433-1640 www.vagliardoinspectionservice.com .

1997 Ashton-Barnes Inspection, Stability, and Spillway Adequacy Report 2002 J.F. Brennan Co. Underwater Inspection Report and Videos 2004 DNR Inspection Report 2008 J.F. Brennan Co. Underwater Inspection Report and Videos 2009 DNR Inspection Report 2010 Stanley Consultants Inspection Report

PROPERTY INSPECTION REPORT Prepared For: Mr. and Mrs. Buyer Concerning: 123 Main Street, Anywhere, Texas 75000 By: Clark Steven Covey TREC # 20460 8/2/2015 PURPOSE, LIMITATIONS AND INSPECTOR / CLIENT RESPONSIBILITIES This property inspection report may include an inspection agreement (contract), addenda, and other information related to

Standard Home Inspection Report . Subject Property: Royal Palm Beach, FL33411. Client: Ms. Brown. Status of Property: unoccupied . Type of Property: Single Family Home . Square Footage: 2196 Total SF (Property Appraiser's data ) Age of Home: 1997 (Property Appraiser's data) Date of Inspection: 02/18/2019 . Time of Inspection: 10:00 AM

Property Inspection Report This report published on Friday, January 29, 2016 10:44:25 AM EST This report is the exclusive property of VT Comfort Home Inspections and the client(s) listed in the report title. Use of this Client(s): Sample Report Property address: ##### Inspection date: Wednesday, January 27, 2016 Page 1 of 59

ANALISIS PENERAPAN AKUNTANSI ORGANISASI NIRLABA ENTITAS GEREJA BERDASARKAN PERNYATAAN STANDAR AKUNTANSI KEUANGAN NO. 45 (STUDI KASUS GEREJA MASEHI INJILI DI MINAHASA BAITEL KOLONGAN) KEMENTERIAN RISET TEKNOLOGI DAN PENDIDIKAN TINGGI POLITEKNIK NEGERI MANADO – JURUSAN AKUNTANSI PROGRAM STUDI SARJANA TERAPAN AKUNTANSI KEUANGAN TAHUN 2015 Oleh: Livita P. Leiwakabessy NIM: 11042103 TUGAS AKHIR .