Surge Protection - PSP Products

10m ago
6 Views
1 Downloads
6.43 MB
32 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Warren Adams
Transcription

Panel mount devices can be installed directly on the main electrical panel or equipment disconnect. Devices range from 100,000 to 400,000 surge Amp capacity and are available in 4, 7 and 10 mode configurations. A variety of enclosures and diagnostic options are available including light-emitting diode (LED) visual indicators. Modules virtually eliminate down-time. 5, 7 and 10 mode configurations available with internal & external 200 kAIC fused disconnects, red/green diagnostic LED’s, audible alarm, digital surge counter, NEMA 4 & NEMA 4X stainless steel enclosures. All units come standard with pop out replaceable modules by mode. Equipment level protection for AC/DC network cable, data and low voltage applications. Available in din-rail and direct inline installation. Modules can be mounted directly into equipment cabinets or can be custom configured in a variety of enclosures.

UL 1449 Listed 4th Edition type 1 for installation on the service entrance or main electrical panel. Common mode suppression with 160,000 Surge Amp capacity and Light-emitting diode (LED) visual indicator for transfer switch protection status. Flush mount plate option available for finished walls. Main panel, Sub Panel & Point of use Applications Up to 200 KAIC fault current rating. Status LED’s audible alarm and dry contacts available 80,000 to 300,000 surge Amps in all single and three phase. Nema 01,04 & 04X Stainless enclosures. UL 1449 4th Edition Type 1 Listed Common mode suppression. 150,000 or 200,000 Amps per phase, NEMA 4 enclosure, 65 & 200 kAIC, LED’s each phase, 7 mode protection, dry contacts, 10 year warranty. Also available in a NEMA 4X enclosure with internal/external fused disconnect and surge counter. Devices are UL 1449 4th Edition and include UL 1283 listing. The Hurricane 3000 Series provides a 200,000 KAIC fault current rating making it suitable for installation at the main service entrance and branch panels. This series is available in 100 kA, 200 kA and 300 kA models and is available in all WYE and Delta voltage configurations. 300,000 Amps per phase, NEMA 4 enclosure, LED’s each phase, 10 mode protection, dry contacts, push to test diagnostics, surge counter. Also available in a NEMA 4X enclosure with internal/external fused disconnect and surge counter. The MS Series is a high-performance UL 1449 Listed Type 1 SPD designed for critical panels located in the harshest environments. The MS Series is available for all single & three phase configurations up to 600 Vac. 100,000, 200,000, or 300,000 surge Amp capacity. Available as individual models, pre-assembled bar assemblies and Dinrail. This device is trusted by the oil and Telecom industries to protect their most critical equipment in vulnerable locations. 100,000 to 600,000 Amps per phase, replaceable modules by mode. Available in NEMA 1, 4, 4X and stainless steel. Full diagnostics including red-green LED’s, dry contacts, audible alarm, surge counter, internal/external fused disconnect. This LED Lighting Surge Protection Device is small enough to fit inside electrical fixture. All devices feature thermal protection which maximizes its efficiency and a LED indicator light that confirms protection is active. 40,000-150,000 surge Amp capacity modules can be combined and configured for almost any requirement. Small footprint allows for internal mounting. Modules include visual end of life indicators and form C dry contacts for remote monitoring. 40,000 surge Amp capacity plug and play Ethernet protection. POE or standard configuration available for a broad range of surge protection applications. Designed to protect sensitive data-monitoring equipment from transient over voltages.

UL 1449 4th Edition listed Common mode suppression with 160,000 Surge Amp Capacity Thermal fused metal oxide varistor (MOV) suppression technology Light-emitting diode (LED) visual indicator for transfer switch protection status NEMA 4 outdoor rated enclosure Available in maximum surge current capacity of 160kA Flush mount plate option available for finished walls Type 4 Enclosure suitable for transfer switches installed inside or outdoors Provides whole house surge protection Surge protection devices with extended operating temperature and the versatility of either a NEMA 1 indoor or NEMA 4 outdoor rated enclosure. The device provides robust protection for the whole home against damaging electrical surges and spikes. Residential Telecommunications Light commercial applications

Surge Protection Device (SPD) Type to UL Operating AC voltage Maximum continuous operating AC voltage (MCOV) Line-Neutral Line-Ground Neutral-Ground Line-Line Nominal discharge current [In] Maximum surge current capacity [I max] Line-Neutral Line-Ground Neutral-Ground Line-Line Fault current rating (SCCR) Voltage protection rating (VPR) Line-Neutral Line-Ground Neutral-Ground Line-Line Suppression technology Connection terminal (suppression) hardwired Operating temperature ( C) Enclosure type (Outdoor) Enclosure dimension (LxWxH) Weight º º

UL 1449 4th Edition listed EMI/RFI filtering Thermally fused MOV’s Common mode suppression Visual and remote verification of protection status Surge current capacity up to 200 kA 8/20μs UL 1449 4th Edition listed Advanced SAD/MOV coordinated hybrid technology Thermally fused MOVs Common mode suppression Visual and remote verification of protection status Surge current capacity up to 200 kA 8/20μs

1Φ 120 2W G 200 Kaic Type 2 600 V 1000 V 600 V 1Φ 120/240 3W G 200 Kaic Type 2 600 V 1000 V 600 V 1000 V 3Φ 208/120Y 4W G 200 Kaic Type 2 600 V 1000 V 600 V 1000 V 1Φ 120/240 3W G 200 Kaic Type 2 600 V 1200 V 700 V 1200 V 3Φ 208/120Y 4W G 200 Kaic Type 2 600 V 1000 V 700 V 1200 V 1Φ 120/240 3W G 200 Kaic Type 2 500 V 800 V 600 V 700 V GS-07F-0435V Certified to ISO 9001:2000

The PSP Vortexx AMV Series features All-Mode AC surge suppression solutions with sine wave tracking circuitry for EMI/RFI filtering. Available in a variety of service voltage configurations, the AMV Series is the ideal choice when applications require all-mode suppression and filtering capabilities. The AMV Series utilizes metal oxide varistors (MOVs) to protect your sensitive electronic equipment from the devastating effects of transient voltage surges. Each phase includes an LED status indicator to show protection status. LED “on” indicates suppressor is functional. LED “off” indicates suppressor or AC power failure. Form C contacts are standard. UL 1449 4th Edition listed 10 Year Warranty UL 1283 listed Max Surge Current/Phase - 300,000 Amps/Phase Form C relay contacts included Operating Temperature: -40º C to 80 C Push-to-test diagnostics EMI/ RFI filtering sine wave tracking circuitry Form C Contact Connection: Terminal Block (#18-#22 AWG wires) Individual thermal fusing and MOV components Suppression Connection - Hardwire (pigtail wires, #10 AWG), 18” minimum (other lenghts available) Fused disconnect option Sine wave tracking circuitry

1Φ 120/240 3W G 200kA with 30Amp Breaker Type 2 600V 600V 600V 900V 1Φ 127/220 3W G 200kA with 30Amp Breaker Type 2 700V 700V 700V 1000V 3Φ 208/120Y 4W G 200kA with 30Amp Breaker Type 2 600V 700V 700V 800V 3Φ 220/127Y 4W G 200kA with 30Amp Breaker Type 2 700V 700V 700V 1000V 3Φ 240/120D 4W G High Leg Delta 200kA with 30Amp Breaker Type 2 900V 900V 800V 1200V 1000V 1200V 1000V 3Φ 480/277Y 4W G 200kA with 30Amp Breaker Type 2 1500V 1500V 1800V 1200V 3Φ 480/277Y 3W G 200kA with 30Amp Breaker Type 2 1500V 1200V GS-07F-0435V Certified to ISO 9001:2000

Small footprint, nipple or bracket installation 75 kA [Imax] surge capacity Thermally protected MOV with dual gas tube technology UL 1449 4th Edition In 10 kA Type 4X indoor/outdoor enclosure Light emitting diode (LED) diagnostic indicator Lifetime warranty UL listed as surge protection device type Operating voltage Maximum continuous voltage (MCOV) Nominal discharge current [In] Maximum surge capacity [Imax] Voltage protection rating (VPR) Suppression technology Operating temperature ( C) Connection terminals Standards º º

[In]: 5kA, 10kA [Imax]: 10kA, 15kA, 25kA GDT for common mode optional Rated voltage: 120V, 277V, 347V, 480V 14 AWG wire, lower clamping voltage IP 66 Agency Approvals: UL, cUL, UL EU, DEMKO, CE, CB Design for UL 1449 Type 4 CA [In]: 5 kA [I max]: 10kA With thermal protection One port and two port optional Two port product apply to waterproof connector Rated operating voltage: 120V, 277V, 347V, 480V Failure indication or signal indication or none GDT for common mode optional IP 66 UL 1449 Type 4 CA and IEC/EN 61643 11 T2 standards With thermal protection One port and two port optional Two port SPD can disconnect the power line when abnormal situation happens Failure indication optional

New patented 7 pin connector with ground connection and plug-in surge protection Surge protection for LED Outdoor Lighting Installations Plug-in Surge Protection Device attaches perfectly to the 7 pin Connector for maximum protection against transients and over voltages Comply with UL 1449, ANSI C136.2-2015, ANSI C136.41, ANSI C136.10 All-mode protection (L-N, L-G, N-G) Unique grounding design In 10kA, Imax 15kA, 20kA Series Connection can be customized

New Patented 7 pin connector with built-in surge protection for outdoor LED lighting installations Series and Parallel connections optional Provides Surge Protection for LED lighting All-mode protection (L-N, L-G, N-G) Unique grounding design In 10kA, Imax 15kA, 20kA Comply with UL 1449, ANSI C136.2-2015, ANSI C136.41, ANSI C136.10 New patented plug-in surge protection device with ground connection Provides surge protection for LED Outdoor Lighting Installations Plug-in Surge Protection Device perfectly attaches to 7 pin Connector for maximum protection against transients and over voltages Comply with UL 1449, ANSI C136.2-2015, ANSI C136.41, ANSI C136.10 All-mode protection (L-N, L-G, N-G) Unique grounding design In 10kA, Imax 15kA, 20kA Series and Parallel connections optional

Imax 100kA 8/20 µs UL 1449 4th Edition Type 1 Listed Common mode suppression Indoor/Outdoor IP66 NEMA 6 rated enclosure (NEMA 6 exceeds NEMA 4 or 4X) In 20 kA (All models) SCCR 200 kA (All models) Meets requirements of UL 96A Lighting Protection Master Label Available in a variety of voltages ranging from 120 to 600 volts AC in Hardwired connection #12 AWG 36” leads Audible Alarm protection status indicator Lifetime free replacement warranty Thermal fused metal oxide varistor (MOV) suppression with in series Gas-Tube technology for maximum surge protection and zero leakage Light emitting diode’s (LED) visual protection status indicator Real time diagnostics by LED per phase and audible alarm Available in maximum surge current capacity of 100,000 surge Amps

System voltage 120 - 208 120 480 4W G (Wye) 2W G (Single) 3W G (Delta) 140 140 550 140 140 / 120 120 / 240 / 560 Total maximal discharge current total 15 8 12 Voltage protection level 700 700 N/A 1200 N/A 2500 System Maximum operating voltage Operating current Follow current Short circuit current rating Maximum Leakage current Maximum recommended fuse Frequency Nominal discharge current Maximum discharge current kA Total maximal discharge current total Shipping dimensions Shipping weight Standard’s compliance or recongn Visual indicator Sound Disconnection Indicator Wiring type Maximum Altitude Operating Temperature Housing enclosure material Mounting type Environmental rating Nema rating Location installation

The Hurricane 3000 Series Surge Suppression device is the culmination of years of technological research and innovation. The Hurricane 3000 provides state of the art protection in 100, 200 and 300 kA/phase configurations. Adaptable to many different voltages and Delta and WYE configurations, the Hurricane 3000 is suitable for almost any TVSS need or environment. The Hurricane 3000 provides protection in all modes, L-N, L-G, N-G AND L-L plus noise filtration up to -50dB. Its robust yet compact NEMA 4 metal enclosure is suitable for both indoor and outdoor installations. Utilizing high-energy MOVs and EMI/RFI filtering, the Hurricane 3000 will protect against transients originating from induced lightning strikes, utility switching or internal motor operation. The Hurricane 3000’s internal SCCR (Short Circuit Current Rating) of 200 kA makes it capable of being installed in both service and branch panel applications without the need for cumbersome inline fusing. UL 1449 4th Edition listed cUL listed Multiple International Listings 4 Levels of Protection LED Status Indicators Audible Alarm NO/NC Dry Contacts NEMA 4 - (Nipple Product) NEMA 4X (option) Noise Filtration Sine Wave Tracking Circuitry 200 kAIC Fault Current Rated Surge Counter (option) Integral Fused Disconnect (option) 10 Year Warranty Nominal Line Voltage 120/208 277/480 347/600 220/380 MCOV 150 V 350 V 480 V 250 V Voltage Protection Rating (VPR) Per UL 1449, 4th Ed. 600 V 1200 V 1500 V 900 V Let Through Voltage Level for Surge Current 10 kA (8/20) (IEEE C62.41-1) 405 V 930 V 1260 V 800 V

50 / 60 / 400 HZ -40 TO 185 F (-10 TO 85 C) Up to -50dB all models 200,000 kAIC fusing/mode 5,000 CAT C3 surges without drift Compliant Yes L-N, L-G, N-G, L-L Yes Form C dry contacts #10 AWG, 24” leads 5 nanoseconds 10 years 3 models 100,000 amps/phase - 50,000 amps/mode 200,000 amps/phase - 100,000 amps/mode 300,000 amps/phase - 150,000 amps/mode Fused safety disconnect Nipple product; NEMA 4. Hardwire; NEMA 4X/NEMA 1 Optional on all models #10 AWG wires NEMA 4 - Terminals #10NEMA 4 4 lbs; NEMA 4X Hardwired w/o disconnect 15 lbs NEMA 4X Hardwired w/disconnect 16 lbs Flush mount 15 lbs Green status LED’s per phase with audible alarm & dry contacts Stainless steel, flush mount, NEMA 1 *Drawing not to scale

Listed UL Type 1 Surge Protective Device Optional Surge Counter Imax 300/400 kA per phase All Environmental Ratings Available UL 1449 4th Edition In 20kA (All models and all modes) Smart Diagnostic Indicating Remaining Surge Capacity SCCR 200kA (All models) Protects All Modes VPR L-N is 700V for 120V, 120/240V, 120/208V Optional UL 1283 Interference Filter Real-Time LED indicators, Audible Alarm, Remote Contacts Electromagnetic The Hurricane 4000 Series is a high-performance UL 1449 Listed Type 1 SPD designed for critical panels located in the harshest environments. The Surge Protective Device (SPD) achieves the highest UL performance ratings for the Nominal Discharge Current (In) and High Current (SCCR) tests while providing a low Voltage Protection Rating (VPR). It is ideally suited for all NEC compliant locations including a UL96A Master Label Lighting Protection System and thus can be deployed with complete confidence. In addition to its rugged performance, the Hurricane 4000 Series has a new Smart-Diagnostic system that includes a multi-stage LED to indicate the exact level of protection present per phase, an audible alarm, remote signal contacts and an optional surge counter. The Hurricane 4000 Series is available for all single & three phase configurations up to 600Vac and is housed in a NEMA 4/12 rated metal enclosure or NEMA 4X stainless steel option. High energy varistor Thermally Protected

120/208 Vac 277/480Vac 347/600 Vac 240 Vac Wye 3Ph N G Wye 3Ph N G Wye 3Ph N G Delta 3Ph G L-G 150 320 550 320 L-N 150 320 550 - N-G 150 320 550 - L-L 300 640 1100 640 10 mA 30 mA System voltage System Maximum Operating Voltage Operating Current Follow Current Maximum Leakage Current mA 10 mA 10 mA L-G 700 1200 1800 1200 L-N 700 1000 1800 - N-G 700 1000 1800 - L-L 1000 1800 3000 1800 A mA Max. Recommended fuse if any Frequency Hz Nominal discharge current per mode kA Maximum Discharge Current per phase Impulse Discharge Current per phase kA Total Maximal Discharge Current kA Total Maximal Discharge Current kA Let through Voltage L-G L-N N-G L-L Voltage Protection Rating Short Circuit Current Rating kA Standard’s Compliance or recognition RFI Filtering Thermal disconnector Overload disconnector Failure indicators Operating Temperature F Housing Enclosure material Mounting type Environmental rating Nema Location Installation IP

UL 1449 4th Edition Listed Noise Filtering cUL Listed Sine Wave Tracking Circuitry Fused Safety Disconnect Switch (Option) Available in 4 - 7 & 10 Mode Design Heavy Duty Modular Construction LED Status Indicators Audible Alarm Push to Test Individual Modules Replaceable by Mode NO/NC Dry Contacts Digital Surge Counter NEMA 4 & Nema 4X Enclosure 10 Year Warranty The Hurricane 5000 Series Surge Suppressors provide “high risk” surge suppression capability at your facility’s service entrance for both conducted (10/350 μs) and induced (8/20 μs) transient over voltages originating from such sources as lightning strikes and utility switching. These protectors incorporate reliable “high intensity” replaceable modules (per mode) with individually monitored and fused MOVs. Designed to various national and international standards, the Hurricane 5000 Series products are ideal as a global protection solution. The Hurricane 5000 Series products come in 4 models, 100,000 amp, 200,000 amp, 400,000 amp and 600,000 amp, and are versatile and scaleable to meet an array of engineering designs. The Hurricane 5000 Series products are housed in a NEMA 4 enclosure and they come standard with a 200 kAIC rating to meet the most demanding needs. Noise filtration up to -50 dB is incorporated providing protection in all modes and is available with or without a fused disconnect to meet all applications. Nominal Line Voltage 120/208 277/480 347/600 220/380 MCOV 150V 350 V 480 V 250 V Voltage Protection Rating (VPR) Per UL 1449, 4th Ed. 600V 1200 V 1500 V 900 V Nominal Discharge Current [I n]: 8/20 20 kA 20 kA 20 kA 20 kA 100 kA 200 kA 400 kA 600 kA

50/60/400 HZ -40 to 160 F (-10 to 70 C) Up to -50dB all models 200,000 kAIC 5,000 CAT C3 Surges without Drift Yes Compliant L-N, L-G, N-G, L-L (where applicable) Yes Form C Dry Contacts #10 AWG, 24” leads 5 nanoseconds 10 years 100,000 amps/phase - 50,000 amps/mode 200,000 amps/phase - 100,000 amps/mode 400,000 amps/phase - 200,000 amps/mode 600,000 amps/phase - 300,000 amps/mode Terminals #10-#2 AWG 100,000 amps/phase 25 lbs. 200,000 amps/phase 26 lbs. 400,000 amps/phase 28 lbs. 600,000 amps/phase 38 lbs. NEMA 4 and 4X Version Yes Red-Green LED’s, Dry Contacts, Audible Alarm, and Push to Test Nema 4X Enclosure - Fused Internal & External Safety Disconnect *Drawings not to scale

Available from 40,000 to 200,000 surge amp capacity. Dry contacts and visual indicators available as well as noise filtration assemblies. The DS70RS is a one pole module that can be configured for both common and differential mode protection in any single and three phase applications to 600V AC. The DS2x0-xxDC surge protector is designed to protect equipment connected to a DC power supply (or AC) against lightning surges. 2 and 4 pair Series Din Rail Surge Protection for Telephone ADSL/SDSLSHDSL, ISDN, Fipway, Fieldbus-H2, 4-20mA, RS232 & RS485, MIC/T2 10 BaseT Products. Available from 6 to 150 DC voltage. 20,000 surge amp capacity. Pop out field replaceable modules. The P8AX series coaxial surge protectors have been designed to protect antennas, microwaves, broadband applications, two-way radios, cellular, GPS and CATV equipment against lightning surges and electrical transients. With patented gas tube and waterproof. B180/480 series are wall mount DC signal line surge protectors designed to protect your sensitive telephone, data com and instrumentation equipment against harmful lightning surges and electrical transients. Maximum line current is 300 mA. The MJ8 and MJ6-1T Series is designed to protect sensitive data-monitoring equipment connected to various network protocols from transient over voltages. The transient protection circuit is based on high energy gas discharge tubes (GDT). Photovoltaic Surge Protectors 500 to 1000 Volts DC with 40,000 Amps Imax. Type 1 UL 1CA DC SPD with High Energy MOV’s, Imax 40 kA modular design with UL 1449 4th edition listing. Modular design for ease of maintenance. Z6-6 (2P) – Surge Stopper United States Navy Shipboard Surge and Noise Suppressor. The PSP Products Model Z6-6 (2P) surge suppressor has been specifically engineered and designed for shipboard use. It is approved for U.S. Navy shipboard use. These devices are based on high energy varistors (MOV) matched with the DC operating voltage (from 12 to 350 Vdc).

DS70RS is a heavy duty AC Surge Protection Device (SPD) for high risk electrical service entrance and branch panel applications. The DS70RS protects against the direct and indirect lightning strikes and large switching transients. They are particularly useful in areas where space is limited. The DS70RS is a one pole module that can be configured for both common and differential mode protection in any single and three phase applications to 600 Vac. The DS70RS has a 70 kA 8/20us surge current rating, low leakage current to ground, no follow current and a low residual clamp voltage. The DS70RS module is din rail mountable with cage terminal connectors for parallel wiring. The DS70RS Series include an integral thermal disconnection compliant to UL-60691, a visual fault indicator, protection redundancy, replaceable modules as well as remote signalization. 230/400 V 277/480 V 480 V 600 V UL Max. Operating Voltage (MCOV) 275 Vac 840 Vac TOV Withstand (UT) 275 Vac 840 Vac IEC/UL Nominal Discharge Current [In] 275 Vac 840 Vac Max. Discharge Current [Imax] 70 kA 70 kA Max. Lightning Current (limp) - - UL Voltage Protection Rating (VPR) 900 V 2500 V Protection Level at In (Up) 1.4 kV 2.5 k V 100 kAIC 100 kAIC 1 mA 1 mA AC Network UL Short-Circuit Current Rating (SCCR) Leakage Current at MCOV (lc) Connection Mode Follow Current (lf) AC System Thermal Disconnector Overcurrent Protection Dimensions Connection Remote Signal Indicator Mounting Operating Temperature (ºC) Operating Altitude Relative Humidity Enclosure Material Environmental Rating Weight

The DS2x0-xxDC surge protector is designed to protect equipment connected to a DC power supply (or AC) against lightning surges. These devices are based on high energy varistors (MOV) matched with the DC operating voltage (from 12 to 350 Vdc). The MOV are equipped with internal thermal disconnectors in order to provide safe end of life. The indication of the disconnection status is provided by a mechanical indicator and is transmitted through a remote signal mechanism. The pluggable module allows an easy and fast maintenance. The DS2x0-xxDC is DIN rail compatible and is connected in parallel on the DC line to be protected. Network voltage (Un) 24 Vdc 75 Vdc Max. Operating Voltage (Uc) 38 Vdc 100 Vdc Nominal discharge current [In] 10 kA 20 kA Maximum discharge current [Imax] 20 kA 40 kA Protection level (@ In) (Up) 250 V 390 V Protective fuses (if necessary) 20 A 50 A Network voltage (Un) 130 Vdc 280 Vdc Max. Operating Voltage (Uc) 180 Vdc 350 Vdc Nominal discharge current (In) 20 kA 20 kA Maximum discharge current (Imax) 40 kA 40 kA Protection level (@ In) (Up) 620 V 1200 V Protective fuses (if necessary) 50 A 50 A Thermal Disconnector Dimensions Connection Disconnection indicator Remote signaling Mounting Operating temperature (ºC) Protection class Housing Material NF EN 61643-11 France IEC 61643-1 Intl UL1449 4th Ed. USA/Canada CSA C22.2 No. 8-M1986

2 and 4 pair Series Din Rail Surge Protection for Telephone ADSL/SDSL-SHDSL, ISDN, Fipway, Fieldbus-H2, 4-20mA, RS232 & RS485, MIC/T2 10 BaseT Products. Available from 6 to 150 DC voltage. 20,000 surge amp capacity. Pop out field replaceable modules. Application Din Rail mounted pluggable surge protector 2-pair versions available (DLA2) Multiple configurations for all applications Multiple grounding options Shielded wire protection UL 497B listed With or without line cut capabilities Removable module for easy maintenance ISDN-T0 48V line Leased line 4-20 mA RS422 Nominal Line Voltage (Un) 48 V 24 V 6V Maximum Line Voltage (Uc) 53 V 28 V 8V Maximum Line Current 300 mA 300 mA 300 mA Maximum Frequency 3 MHz 3 MHz 3 MHz Protection Level (Up) 8/20µs impulse - 5 kA 70 V 40 V 20 V Nominal Discharge Current [In] 8/20µs impulse - 10 times 10 kA 10 kA 10 kA Maximum Discharge Current [Imax] 8/20µs impulse - 1 time 20 kA 20 kA 20 kA Impulse Current (limp) 10/350µs impulse - 2 times 5 kA 5 kA 5 kA Short-circuit Short-circuit Short-circuit End of life Configuration Mounting Operating temperature Wiring Housing material Earth Connection Replacement module Versions NF EN 64643-21 (France) UL 497B (USA) DLA 6403021 6403011 6401011 DLA2 640312 640311 640111

The P8AX series coaxial surge protectors have been designed to protect antennas, microwaves, broadband applications, two-way radios, cellular, GPS and CATV equipment against lightning surges and electrical transients. They are a first line of defense for your sensitive equipment. The P8AX series employs a patented gas tube, are waterproof (IP65) and available with three grounding options: M6 ground screw, bulkhead or optional mounting bracket. 1 20 kA transient amps protection (8/20 μs) Insertion Loss 0.1dB 5 kA transient amps protection (10/350 μs) Bi-directional, series installed DC Pass to /-48V Waterproof VSWR 1.2 Removable GDT Frequency Range DC-5 GHz DC Turn-On (Breakdown) 200-300 V Technology Gas Discharge Tube lnsertion Loss 0.1 db Return Loss 20 db VSWR 1.2:1 lpeak (8/20 μs) 20 kA Max Power 190 W Max current 10 A lmpedance 50 omhs1 Connection Method Series (bi-directional) Connectors N, TNC, SMA, F, BNC, 7/16 Grounding M6 Screw, Bulkhead, Bracket Connectors N, TNC, SMA, F, BNC, 7/16 Environmental IP65 Rating -50 C to 85 C Operating Altitude M6 Screw, Bulkhead, Bracket Relative Humidity up to 5 to 95% non-condensing, up to 100% Weight 4.4 oz Impedance for F-Type Connector is 75 Ohms.

PB180BL, PB280BL and PB480BL series are wall mount phone line surge protectors designed to protect your sensitive telephone against harmful lightning surges and electrical transients. The PB Series utilizes a hybrid protection circuit consisting of high energy Gas Discharge Tubes (GDTs) and fast clamping diodes that offer an ultra fast response time ( 1 ns) and a very high power handling capability of 20kA 8/20μs. These units automatically reset after each surge event. 1, 2, or 4 pair protection units Maximum line current is 300 mA All types of telephone and data lines IEC-61643-21 Removable protection circuit board UL4197B Wall or surface mount 1-pair unit 2-pair unit 4-pair unit Application Configuration protected -PB180BL. -PB280BL. -PB480BL. Nominal line voltage (Un) Max. line voltage (Uc) Max. clamping voltage Protection Level (Up) Nominal discharge current (Up) Max. discharge current [Imax] Lightning Current (limp) Type of diagram End of Life Mounting Dimensions Wiring Housing material

These units are designed to protect sensitive communication terminals (telephone sets, fax, modem, ADSL terminals.) connected to analog or digital telephone lines (PSTN or ADSL) from lightning surges and electrical transients. 1-pair Surge Protector Wall mounting for telephone line (PSTN or ADSL) complies IEC 61643-21 standard RJ11 connector in/out Easy installation GDT: 3-electrode gas tube R: Resistor D: Clamping diode network Application Bandwidth Nominal line voltage (Un) Maximum line voltage (Uc) Residual voltage (Up) Nominal discharge current [In] I/O connections Wiring Mounting Grounding

Designed with High Energy MOV’s Imax: 40 kA /pole at 8/20μs Modular Design for Ease of Maintenance In: 20 kA /pole at 8/20μs Integrated Status Indicator Window UL 1449 4th Edition Recognized Maximum PV Voltage - Ocstc 600 Vdc 1000 Vdc Protection Mode* CM/DM CM/DM Maximum Operating Voltage - Ucpv 680 Vdc 1060 Vdc Current Withstand Short - Circuit - Iscwpv 1000 A 1000 A Operating Current to the voltage Ucpv - Icpv 0.1 mA 0.1 mA Leakage Current to the voltage - Ucpv - Ipe 0.1 mA 0.1 mA Nominal Discharge Current 15 x 8/20 μs Impulses - [In] 20 kA 20 kA Maximum Discharge Current 8/20 μs Withstand - [Imax] 40 kA 40 kA Protection Level (at In) - Up 2.5 kV 3.6 kV Dimensions Connection End of life mode Disconnection indicator Remote Signaling of Disconnection Mounting Operating Temperature º Protection Class Housing Material Thermal Disconnector prEN50539 - 11: Europe UL 1449 4th Edition: USA Type 1CA S50PVS - 500 S50PVS - 600 S50PVS - 800 S50PVS - 1000 (*)CM Common mode ( /PE or -/PE) - DM Differential mode ( /-) Type 1CA

The MJ8 Series is designed to protect sensitive data-monitoring equipment connected to various network protocols from transient over voltages. The MJ8 Series surge protector is deployed in a RS485 signal network applications with data transmission speeds of up to1000 Mbps. The surge protector is housed in a shielded enclosure with high quality shielded RJ45 jacks. The transient protection circuit is based on high energy gas discharge tubes (GDT) and a network of fast response silicon avalanche diodes (SAD) to achieve sharp clamping of very large surge events. red curve: maximum limit Max. data rate Max. DC supply Pinouts Line-Line Line-Ground Input Output Pinout Enclosure Ground connection Standard Compliance 1000 Mbps 1000 Mbps 18 Vdc 600 mA 180 Vdc 600 mA (1-2) (3-6) (4-5) (7-8) (1-2) (3-6) (4-5) (7-8)

Z6-6 (2P) – Surge Stopper United States Navy Shipboard Surge and Noise Suppressor. With technology ahead

Provides Surge Protection for LED lighting All-mode protection (L-N, L-G, N-G) Unique grounding design In 10kA, Imax 15kA, 20kA Comply with UL 1449, ANSI C136.2-2015, ANSI C136.41, ANSI C136.10 New patented plug-in surge protection device with ground connection Provides surge protection for LED Outdoor Lighting .

Related Documents:

steady fl ow from the header tank through the surge pipe. This fl ow creates a measurable head loss (due to friction) along the surge pipe from the header tank to the surge tower. To create the surge, students quickly shut the surge valve downstream of the surge pipe. VDAS displays and records the pressure surge in the surge tower. Students

surge protection units provide premier surge protection for AC power at the service entrance. These products provide protection for residential electrical equipment by reducing power surges to an acceptable level for surge strips to handle at the point of use. UL 1449 3rd Edition Type 1 and Type 2 Surge Protection Type 1 Surge Protective

Type 2 surge arresters are tested with a 8/20 ms current wave. Type 3 surge arresters are tested with a 1.2/50 ms and 8/20 ms combined wave. Protection Load protection iPRD, iPRD IT surge arresters Type 2 or 3 LV withdrawable surge arresters Each surge arrester in the range has a specific application: b incoming protection (type 2):

Surge ProtectIon STV 200/400K Series 7 . Surge protective devices tailored to protect CCTV, data, audio and cable applications. StFv . Surge ProtectIve devIce/FIlter APPlIcAtIon SelectIon tAble Surge Protection Active Tracking Filtering With Surge Protection Data/Signal

surge protection arrangement is required to be done at different levels. 1.3 Surge protection devices (SPDs) Surge Protection Devices can protect the electronic equipment from the potentially destructive effects of high-voltage transients.The Surge Protection Devices have following features: 1. Rapid operation, 2. Accurate voltage control and 3.

The coincidence of wind surge, spring high tide and external surge leads to extreme storm surge levels along the coast (figure 4). Figure 4: The components of a storm surge. Thus a storm surge is composed of the local tides, wind surge and a possible external surge. In the project storm surges from 1901 until 2008 at tidal gauge

close to the source of interference as possible as protection against swit-ching surge voltages. In the case of buildings with an external lightning protection system or in the case of supply via an exposed cable, a type 1 surge arrester must also be used. Protection area OBO surge protection devices limit the voltage at the installation location

Agile describes a set of guiding principles that uses iterative approach for software development Agile is a practice that helps continuous iteration of development and testing in the software development process. In this model, development and testing activities are concurrent, unlike the Waterfall model. This mindset allows more communication .