Bill Redirect Software How redirect the weight of a USB Scale (Supports several Postal Scales) Postal USB Scale, Mettler Toledo PS60 PS90, Pitney Bowes, Fairbanks, X.J., CHARDER, Pelouze, SANFORD, DYMO, Endicia, ELANE.XM, Elane Plus BT Bluetooth, Stamps digital USB postal scale Use this documentation with the product : Bill Redirect Version 8.0L or more. (Rev.:19/11/2016) RS232 USB Balance and Scale Software: 32 USB balance scale software.htm Email: info@BillProduction.com

SOFTWARE DESCRIPTION Bill Redirect software supports several models of USB scales ! This professional software enables USB scales who do not come with a serial port driver to communicate with your current Windows applications. Bill Redirect allows information to be entered directly into Windows programs as if it was typed in using the keyboard. No programming or additional hardware required ! Supported Operating Systems: Windows 98,Me,2000,3000,XP,NT4, Vista, Windows 7, Windows 8 Simply the best scale software available ! 1

GENERAL INFORMATION To configure this software you have to enter in the field password www.billproduction.com, In the configuration options you have the possibility to change this password for what you want. To close this software, type END in the password field. If a problem persist or to do more use our Software configuration and integration service It's free, fast (usually the same day), and efficient ! Submit your case to info@billproduction.com and receive a customized solution ! 2

To redirect a USB Scale to keyboard buffer Use this documentation ONLY if your Scale is USB and do not come with a serial port driver Step #1 (General configuration) First download and install Bill Redirect software: http://www.billproduction.com/Bill COMtoKB.ZIP *To access the configuration, enter the 'Password' field: www.billproduction.com Disable all except the Serial Port and Keyboard Buffer section Set to OFF Serial Port and Pressed key switch 3

Step #2 (USB configuration) Activate the option: USB Scale Without Serial Port driver Make sure that your product is plugged and power on Wait 30 seconds If after this time it’s always written “Not Found” in the field status, please contact our technical support: info@billproduction.com include with your email: Your scale Manufacturer and Model Choose the Output Format * You can enter your own format, example to receive the weight with unit: {lbs} lbs{ENTER} Set the option “Send weight” to: When is stable 4

Step #3 (Keyboard configuration) Click on button: Configuration Activate the option: API KB user 32 The QWERTY option: Select this option if you use a QWERTY keyboard. *If your keyboard is QWERTY you can see just across the letter Q the letters WERTY The AZERTY option: Select this option if you use a AZERTY keyboard. *If your keyboard is AZERTY you can see just across the letter A the letters ZERTY The Target Windows Name (optional): With this option you can activate automatically a target windows. Enter the title of the window where you want redirect the data * If you enter nothing, the software redirect the data to the current window. * You can enter just a part of the title, for example if the title is “my application software” you can enter just a part of the title for example: my application The U. Case option: The software can switch all lower case characters automatically to upper case. Step #4 (Test stable mode) TEST YOUR SCALE Open the Windows NotePad Put something on the scale The weight should be written in the NotePad when it is stable. 5

Step #5 (Optional: Use a Virtual button to receive the weight) In “Serial Port Configuration” set option “Send weight” to: On demand Click on button: Configuration To add a New button, click on button: Add 6

Step #6 (Optional: Use a Virtual button to receive the weight) At this step you can see a button like this one: *To see the configuration of the button activate the upper left check box Enter in field “String to send if this button is push”: {USB TX[REQWEIGHT]} Button Text: Use this field to set what you want to see on the button. Button Position: Use this section to change button position. * Tips: Activate the NumLock Click the button and use the number 4,6,2 and 8 to change the position. Button Size : Use this section to change the button size. 7

Step #7 (Optional: Use a Virtual button to receive the weight) Example: Window Title (optional): Option “Window Title” Description: With this option each button of your Virtual Keyboard can appear and disappear when a specific window title is activate. *Example: If the window title is “Application weight expert Version 1.2b” and in the field “Window Title” you enter “Weight EXPERT” then each time that this window take the focus this button is visible. * To enter more of one window title, separate the title name by a comas: Example: Weight EXPERT, NOTEPAD, PAGE COUNT * If this the field “Window Title” is blank, then the button is always visible. Color (optional): Use this option to change the button back color. Font (optional): Use this option to change the button text font. Picture (optional): Use this section to: Paste the picture from the Clipboard to the button. Clear the picture button. Load the picture button. 8

Step #8 (Optional: Use a hotkey to request the weight) This optional step will allow you to request the weight from your scale via a hotkey for example F11. Section “Pressed key” set the switch to position: On Click on: Data Filtering Configuration Enter in field “Prefix”: {PAUSE.5SEC} Click on: ADD Enter in field “Search”: {F11} * You can replace the hotkey {F11} by what you want example {ALT}{F10} Enter in field “Replace by”: {TX KEYB[{CTRL UP}{ALT UP}{USB TX[REQWEIGHT]}]} 9

Step #9 (Test: Virtual Button / Hotkey to request the weight) TEST YOUR SCALE Click on button: Run Open the Windows NotePad Put something on the scale Click on your: Virtual Button The weight should be written in the NotePad when you click the button. If a problem persist or to do more use our Software configuration and integration service It's free, fast (usually the same day), and efficient ! Submit your case to info@billproduction.com and receive a customized solution ! 10

Step #10 (Optional: To see the weight in real-time directly on the virtual button) In “Serial Port Configuration” set option “Send weight” to: Continuous Set the “Keyboard Buffer” switch to: OFF Click on button: ADD In the field “Search” enter: {USB RX} In the field “Replace by” enter: {TX BUTTON TXT[0, RX DATA]} Section “Virtual Keyboard” Configuration “Button Configuration” edit this option: String to send if this button is push: {TX KEYB[{BUTTON TXT[0]}]} 11

Step #11 (Test: Weight in real-time directly on the virtual button) TEST YOUR SCALE Click on button: Run Open the Windows NotePad Put something on the scale Click on your: Virtual Button The weight should be written in the NotePad when you click the button. 12

Step #12 (Optional: Button in MS Access and weight to field) Use this Step to receive the weight in your MS Access form. With this solution the button to request the weight is directly in your MS Access form and the weight is sent directly in the good field of your form ! Bill Redirect software configuration: Enable the section: File In File section, set the switch to: Read In Serial Port section, set the switch to: Off In Serial Port Configuration set option Send weight to: On demand In Keyboard Buffer section, set the switch to: On In Pressed Key section, set the switch to: Off In File Configuration, enter in field File: C:\BillProduction.cfg\request.txt In File Configuration, check the option: Delete the file after reading On main screen, click on button: Save Configuration MS Access Form configuration: In your MS ACCESS to receive the weight in your form. add this code on a button in your form: On Error Resume Next Text1.SetFocus Open "C:\BillProduction.cfg\request.txt" For Append As #1 Print #1, "{TX KEYB[{CTRL UP}{ALT UP}{USB TX[REQWEIGHT]}]}" Close #1 Replace Text1 by your Text Box field name where you want receive the weight If a problem persist or to do more use our Software configuration and integration service It's free, fast (usually the same day), and efficient ! Submit your case to info@billproduction.com and receive a customized solution ! 13

For more documentation visit: http://www.billproduction.com/documentation.html To receive the data in real time to a existing Excel file, install our Excel Plugin: http://www.billproduction.com/Plugin DDE.zip Use this documentation: http://www.billproduction.com/Bill DDE over Ethernet.pdf If a problem persist or to do more use our Software configuration and integration service It's free, fast (usually the same day), and efficient ! Submit your case to info@billproduction.com and receive a customized solution ! 14

Bill Redirect Software How redirect the weight of a USB Scale (Supports several Postal Scales) Postal USB Scale, Mettler Toledo PS60 PS90, Pitney Bowes, Fairbanks, X.J., CHARDER, Pelouze, SANFORD, DYMO, Endicia, ELANE.XM, Elane Plus BT Bluetooth, Stamps digital USB postal scale

Related Documents:

Pelouze 10-lb USB Postal Scale The Pelouze 10-lb USB Postal Scale weighs items up to ten pounds (4.5 kg) in 0.2-ounce (5 g) increments. This document provides instructions for using the scale. Installing the Scale The scale is powered through a USB port on your computer. When not connected to your computer, the scale can be powered by an

In-box 1m cable or Jabra 1.8m cable How to connect using Anker PowerLine/Newnex cable USB-A USB-C 3m USB-A to USB-C cable How to connect using Startech USB 3.0/USB 2.0 Startech USB Extender Power Adapter USB-A USB-A USB-C In-box

APC Back-UPS USB USB APC Back-UPS RS USB USB APC Back-UPS LS USB USB APC Back-UPS ES/CyberFort 350 USB APC Back-UPS BF500 USB APC BACK-UPS XS LCD USB APC Smart-UPS USB USB APC Back-UPS 940-0095A/C cables APC Back-UPS 940-0020B/C cables APC Back-UPS 940-0023A cable APC Back-UPS Office 940-0119A cable APC Ba

RESULTS TO A USB FLASH DRIVE in the Quickstart Poster for instructions.) Note: Use the included USB flash drive to store/transfer readings. Other USB flash drives may not be compatible with USB Scale. 2. Connect that USB flash drive to a free USB port on your computer (or on a powered USB hub). 3. Open the software by going to Start ! All .

4. USB 2.0 connector Connect USB-compatible devices, such as a USB keyboard, USB mouse, USB storage device, or USB printer. 5. USB 3.2 connector Gen 1 Connect USB-compatible devices, such as a USB keyboard, USB mouse,

USB-COMi-TB . USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual . The USB-COMi-TB USB-to-Industrial Single RS-422/485 Adapter is designed to make industrial communication port expansion quick and simple. Connecting to a USB port on your computer or USB hub, the USB-COMi-TB instantly adds an industrial communication port to your .

Bridgeport CNC TorqCut 22 USB-A001 Bridgeport Lathe - EZ-Path USB-A001 Bridgeport Mille - EZ Trax DX USB-A001 . HAAS Mini Mill USB-A001 HAAS SL20 Lathe 1999 USB-A001 HAAS VF2 Mill USB-A001 HAAS VF3 USB-A001 HAAS VF7 w/ Mitsumi D359T6 USB-D022 HACO ERM40200 USB-D001 Happy Embroidery Machine USB-D003

three main factors used for determining the premium rates under a life insurance plan are mortality, expense and interest. The premium rates are revised if there are any significant changes in any of these factors. Mortality (deaths in a particular area) When deciding upon the pricing strategy the average rate of mortality is one of the main considerations. In a country like South Africa .