1

Company profileZhejiang Sandi Electric Co., Ltd is an international PV enterprise which is located in the"capital of China's electrical appliances" Wenzhou. Specialized in the new energy source andelectrical source scientific research, development, manufacture and service had surpasses for15 years.Sandi company's products are widely applied in solar or wind energy, construction, industry,new energy source, civilian use, electric power, medical treatment, aviation, automatically controlsystem of war industry and national heavy engineering project.Main products: PV Grid-connected inverter, Solar off grid pure sine wave inverter, solarpump inverter, PV array combiner box, solar charge controller, wind-solar hybrid controller,single phase to three phase converter and etc products.Sandi is recognized by widely customers according to entirely varieties, high quality andservice first. The R&D and engineering technicians have multi-year experiences in productdesign, product implementation, engineering service and can manufacture the solar energygeneration products with the international competition capability reaches advanced level in theworld, our product have passed CE(EMC&LVD), SAA(AS4777&AS3100), G83/1, G59, VDEARN 4105 and EN62109, EN61000 certification and approved by international standard.SANDI Electric Company insist on technology as forerunner, keep long-term, goodresearch cooperation with all universities; fetch in and absorb international advanced technology,built strictly quality control system.We will take the work objective of “unremitting exploration, endeavor and innovation,honesty and dedication, perfect and practicality” and quality guideline of “criterion management,intensive manufacture, quality first, service with all hearts”. Seek excellence, value innovation!We will ceaselessly struggle and create refulgence with you together.2

Qualification certificate3

Product IntroductionSANDI SDP series Pure Sine Wave Inverter is the one of the most advanced technology DC toAC conversion products in the world, it’s suitable use for areas without electricity, providing acomplete power solution for strict demand applications. With SVPWM technology it has highconversion efficiency, high instantaneous power and low losses power output pure sine wave,applying to capacitive, inductive and nonlinear mixed-load, with superior load capacity, perfectprotection function: overload, short circuit, low/over battery voltage, improper operation etc,which won’t cause mechanical failures. This Inverter is very suitable for solar power systems,wind power generation systems, wind and solar hybrid generation systems. The inverter cansupply AC power to all kinds of electric equipment, air conditioners, electric motors, refrigerators,fluorescent lights, televisions, electric fans and other industrial power supply.Technical Features: Using the sixth generation efficient IPM intelligent module from Japanese Mitsubishi, highefficiency and stable performance. It with powerful protection function, the protection forshort circuit, over load, over temperature is more safe and reliable. It’s service life can up to15 years or more. Intelligentized, modularized, simple structure design easy to maintenance. According to the product configuration conditions, adjustment the system usage mode:DC(Battery/Solar) priority or AC mains bypass priority can be set. Two kinds of start mode: Reduction Voltage Start and Variable Frequency Start. Customerscan set start mode according to the type of their load. This function is very convenient forusers and also reduce frequency converter’s usage, which reduced the cost of equipmentinvestment, easy to connect wires and control. The output frequency can be setting via LCD panel, it’s very convenient for customer. The output voltage can be set between -40 % to 20 % of rated voltage. And the outputvoltage is very accuracy 1%. The DC input voltage range can be set. Over-voltage point, under-voltage point, over-voltagerecovery point, under-voltage recovery point all can be setting via the LCD panel. Pure sine wave output. With good dynamic response less than 50MS, waveform distortionrate smaller, higher conversion efficiency and stable output voltage. Built-in low frequency isolation transformer, strong impact resistance, available with motors,pump, air conditioners and other high impact equipment. At the same time DC busbar andAC busbar are completely isolated to avoid interference.4

Wide input voltage can be set according to customer’s requirement. Input voltage range canbe selected from 100-300V, 200-500V or 500-850V, suitable for solar/wind system withoutbackup batteries, it can save many cost and maximization use the solar/wind energy. Using SVPWM space vector algorithms, high conversion efficiency, high instantaneouspower and low losses conversion efficiency up to 94%. Powerful data display function. LCD can display the DC input voltage, output frequency,phase voltage, phase current, AC bypass input voltage, output power KWH, time and date,temperature, fault code display. European CE (EMC, LVD) certificate, accredited by Australian CEC, ERAC energy network.[Optional] RS485 remote monitoring; Can add AC bypass input complementary function;PV Off-grid Solar Power SystemPV Off-grid solar power generation system including solar panel array, solar charge controller,storage battery, Off-grid inverter, PV combiner box and etc. In the sunshine, the solar panelconvert the solar energy to DC power and charge the battery group by the charge controller.Then the off grid inverter convert the DC power into AC power for power supply the AC load.5

Technical ParameterModelSDP-3KWIsolation modeSDP-4KWLow Frequency TransformerDC InputRated voltage (Vdc)48Vdc96Vdc48Vdc96VdcRated current (A)62.5A31A83A42A43 80V86 150V43 80V86 150VInput voltage range (Vdc)AC OutputRated power (Kw)Rated voltage3KW4KW220V 3%380V 3%220V 3%380V 3%Number of phases1 phase 2 wire3 phase 4 wire1 phase 2 wire3 phase 4 wireRated current (A)13.6A4.5A18A6ARated output voltage range (V)110/120/220/230/240/380/400/415/440/480VAC (optional)Output frequency50Hz or 60Hz 0.05 (Can set)WaveformPure sine waveWaveform distortion rate (THD)Linear load 2%Dynamic Response time(Load 0 100%)5%, 50msPower Factor (PF)0.99Inverter Efficiency 94%Electrical insulation properties2000Vac、1 MinuteProtection FunctionOverload AbilityProtection150%、10sInput reverse polarity, under voltage, overvoltage, output over-current,short circuit, overheating etc.DisplayLCDCommunication interface (optional)RS485 (A、B)Method of workingWorking continuouslyCooling methodShort-circuit protectionFan-cooledNo automatic recovery, need to restart the machineWorking Environment & Mechanical dimensionDegree of protectionIP20 (indoor) 2500mWorking Altitude(m)Working temperature ( )-15 50 Relative humidity ( )0 90%, No condensation 50dBNoise ( 1 meter)Unit size: (W x D x H)Reference weight (Kg)550 450 750mm60KgOur company can adjust parameter configuration according to user’s requirement.665Kg

Technical ParameterModelSDP-5KWIsolation modeSDP-6KWLow Frequency TransformerDC InputRated voltage (Vdc)Rated current (A)Input voltage range (Vdc)96Vdc120Vdc96Vdc120Vdc52A42A62.5A50A86 140V108 175V86 140V108 175VAC OutputRated power (Kw)Rated voltage5KW6KW220V 3%380V 3%220V 3%380V 3%Number of phases1 phase 2 wire3 phase 4 wire1 phase 2 wire3 phase 4 wireRated current (A)23A7.5A27A9ARated output voltage range (V)110/120/220/230/240/380/400/415/440/480VAC (optional)Output frequency50Hz or 60Hz 0.05 (Can set)WaveformPure sine waveWaveform distortion rate (THD)Linear load 2%Dynamic Response time(Load 0 100%)5%, 50msPower Factor (PF)0.99Inverter Efficiency 93%Electrical insulation properties2000Vac、1 MinuteProtection FunctionOverload AbilityProtection150%、10sInput reverse polarity, under voltage, overvoltage, output over-current,short circuit, overheating etc.DisplayLCDCommunication interface (optional)RS485 (A、B)Method of workingWorking continuouslyCooling methodShort-circuit protectionFan-cooledNo automatic recovery, need to restart the machineWorking Environment & Mechanical dimensionDegree of protectionIP20 (indoor) 2500mWorking Altitude(m)Working temperature ( )-15 50 Relative humidity ( )0 90%, No condensation 50dBNoise ( 1 meter)Unit size: (W x D x H)Reference weight (Kg)550 450 750mm80KgOur company can adjust parameter configuration according to user’s requirement.790Kg

Technical ParameterModelSDP-8KWIsolation modeSDP-10KWLow Frequency TransformerDC InputRated voltage (Vdc)Rated current (A)Input voltage range (Vdc)120Vdc192Vdc192Vdc240Vdc67A42A52A42A108 175V172 275V172 275V216 340VAC OutputRated power (Kw)Rated voltage8KW10KW220V 3%380V 3%220V 3%380V 3%Number of phases1 phase 2 wire3 phase 4 wire1 phase 2 wire3 phase 4 wireRated current (A)36A12A45.5A15ARated output voltage range (V)110/120/220/230/240/380/400/415/440/480VAC (optional)Output frequency50Hz or 60Hz 0.05 (Can set)WaveformPure sine waveWaveform distortion rate (THD)Linear load 2%Dynamic Response time(Load 0 100%)5%, 50msPower Factor (PF)0.99Inverter Efficiency 93%Electrical insulation properties2000Vac、1 MinuteProtection FunctionOverload AbilityProtection150%、10sInput reverse polarity, under voltage, overvoltage, output over-current,short circuit, overheating etc.DisplayLCDCommunication interface (optional)RS485 (A、B)Method of workingWorking continuouslyCooling methodShort-circuit protectionFan-cooledNo automatic recovery, need to restart the machineWorking Environment & Mechanical dimensionDegree of protectionIP20 (indoor) 2500mWorking Altitude(m)Working temperature ( )-15 50 Relative humidity ( )0 90%, No condensation 50dBNoise ( 1 meter)Unit size: (W x D x H)Reference weight (Kg)550 550 875mm110KgOur company can adjust parameter configuration according to user’s requirement.8120Kg

Technical ParameterModelSDP-15KWIsolation modeSDP-20KWLow Frequency TransformerDC InputRated voltage (Vdc)Rated current (A)Input voltage range (Vdc)192Vdc240Vdc240Vdc360Vdc78A62.5A83A55.5A172 275V216 340V216 340V324 480VAC OutputRated power (Kw)Rated voltage15KW20KW220V 3%380V 3%220V 3%380V 3%Number of phases1 phase 2 wire3 phase 4 wire1 phase 2 wire3 phase 4 wireRated current (A)68A23A90A30ARated output voltage range (V)110/120/220/230/240/380/400/415/440/480VAC (optional)Output frequency50Hz or 60Hz 0.05 (Can set)WaveformPure sine waveWaveform distortion rate (THD)Linear load 2%Dynamic Response time(Load 0 100%)5%, 50msPower Factor (PF)0.99Inverter Efficiency 93%Electrical insulation properties2000Vac、1 MinuteProtection FunctionOverload AbilityProtection150%、10sInput reverse polarity, under voltage, overvoltage, output over-current,short circuit, overheating etc.DisplayLCDCommunication interface (optional)RS485 (A、B)Method of workingWorking continuouslyCooling methodShort-circuit protectionFan-cooledNo automatic recovery, need to restart the machineWorking Environment & Mechanical dimensionDegree of protectionIP20 (indoor) 2500mWorking Altitude(m)Working temperature ( )-15 50 Relative humidity ( )0 90%, No condensation 50dBNoise ( 1 meter)Unit size: (W x D x H)Reference weight (Kg)550 550 875mm145KgOur company can adjust parameter configuration according to user’s requirement.9180Kg

Technical ParameterModelSDP-25KWIsolation modeSDP-30KWLow Frequency TransformerDC InputRated voltage (Vdc)Rated current (A)Input voltage range (Vdc)240Vdc360Vdc240Vdc360Vdc104A69.5A125A83A216 340V324 480V216 340V324 480VAC OutputRated power (Kw)Rated voltage25KW30KW220V 3%380V 3%220V 3%380V 3%Number of phases1 phase 2 wire3 phase 4 wire1 phase 2 wire3 phase 4 wireRated current (A)114A38A136A45.5ARated output voltage range (V)110/120/220/230/240/380/400/415/440/480VAC (optional)Output frequency50Hz or 60Hz 0.05 (Can set)WaveformPure sine waveWaveform distortion rate (THD)Linear load 2%Dynamic Response time(Load 0 100%)5%, 50msPower Factor (PF)0.99Inverter Efficiency 93%Electrical insulation properties2000Vac、1 MinuteProtection FunctionOverload AbilityProtection150%、10sInput reverse polarity, under voltage, overvoltage, output over-current,short circuit, overheating etc.DisplayLCDCommunication interface (optional)RS485 (A、B)Method of workingWorking continuouslyCooling methodShort-circuit protectionFan-cooledNo automatic recovery, need to restart the machineWorking Environment & Mechanical dimensionDegree of protectionIP20 (indoor) 2500mWorking Altitude(m)Working temperature ( )-15 50 Relative humidity ( )0 90%, No condensation 50dBNoise ( 1 meter)Unit size: (W x D x H)Reference weight (Kg)600 700 1150mm220KgOur company can adjust parameter configuration according to user’s requirement.10270Kg

Technical ParameterModelSDP-40KWIsolation modeSDP-50KWLow Frequency TransformerDC InputRated voltage (Vdc)Rated current (A)Input voltage range (Vdc)360Vdc384Vdc360Vdc384Vdc111A104A139A130A324 480V345 550V324 480V345 550VAC OutputRated power (Kw)Rated voltage40KW50KW220V 3%380V 3%380V 3%Number of phases1 phase 2 wire3 phase 4 wire3 phase 4 wireRated current (A)182A60A76ARated output voltage range (V)220/230/240/380/400/415/440/480VAC (optional)Output frequency50Hz or 60Hz 0.05 (Can set)WaveformPure sine waveWaveform distortion rate (THD)Linear load 2%Dynamic Response time(Load 0 100%)5%, 50msPower Factor (PF)0.99Inverter Efficiency 93%Electrical insulation properties2000Vac、1 MinuteProtection FunctionOverload AbilityProtection150%、10sInput reverse polarity, under voltage, overvoltage, output over-current,short circuit, overheating etc.DisplayLCDCommunication interface (optional)RS485 (A、B)Method of workingWorking continuouslyCooling methodShort-circuit protectionFan-cooledNo automatic recovery, need to restart the machineWorking Environment & Mechanical dimensionDegree of protectionIP20 (indoor) 2500mWorking Altitude(m)Working temperature ( )-15 50 Relative humidity ( )0 90%, No condensation 50dBNoise ( 1 meter)Unit size: (W x D x H)Reference weight (Kg)650 750 1200mm315KgOur company can adjust parameter configuration according to user’s requirement.11360Kg

Technical ParameterModelSDP-60KWIsolation modeSDP-80KWLow Frequency TransformerDC InputRated voltage (Vdc)Rated current (A)Input voltage range (Vdc)384Vdc480Vdc384Vdc480Vdc104A125A208A167A345 550V432 650V345 550V432 650VAC OutputRated power (Kw)60KW80KW380V 3%380V 3%Number of phases3 phase 4 wire3 phase 4 wireRated current (A)91A121ARated voltageRated output voltage range (V)220/230/240/380/400/415/440/480VAC (optional)Output frequency50Hz or 60Hz 0.05 (Can set)WaveformPure sine waveWaveform distortion rate (THD)Linear load 2%Dynamic Response time(Load 0 100%)5%, 50msPower Factor (PF)0.99Inverter Efficiency 93%Electrical insulation properties2000Vac、1 MinuteProtection FunctionOverload AbilityProtection150%、10sInput reverse polarity, under voltage, overvoltage, output over-current,short circuit, overheating etc.DisplayLCDCommunication interface (optional)RS485 (A、B)Method of workingWorking continuouslyCooling methodShort-circuit protectionFan-cooledNo automatic recovery, need to restart the machineWorking Environment & Mechanical dimensionDegree of protectionIP20 (indoor) 2500mWorking Altitude(m)Working temperature ( )-15 50 Relative humidity ( )0 90%, No condensation 50dBNoise ( 1 meter)Unit size: (W x D x H)Reference weight (Kg)750 750 1485mm420KgOur company can adjust parameter configuration according to user’s requirement.12490Kg

Technical ParameterModelSDP-100KWIsolation modeSDP-150KWLow Frequency TransformerDC InputRated voltage (Vdc)384Vdc480Vdc480Vdc540VdcRated current (A)260.5A208A312.5A278A345 550V432 650V432 650V486 750VInput voltage range (Vdc)AC OutputRated power (Kw)100KW150KW380V 3%380V 3%Number of phases3 phase 4 wire3 phase 4 wireRated current (A)151.5A227ARated voltageRated output voltage range (V)220/230/240/380/400/415/440/480VAC (optional)Output frequency50Hz or 60Hz 0.05 (Can set)WaveformPure sine waveWaveform distortion rate (THD)Linear load 2%Dynamic Response time(Load 0 100%)5%, 50msPower Factor (PF)0.99Inverter Efficiency 93%Electrical insulation properties2000Vac、1 MinuteProtection FunctionOverload AbilityProtection150%、10sInput reverse polarity, under voltage, overvoltage, output over-current,short circuit, overheating etc.DisplayLCDCommunication interface (optional)RS485 (A、B)Method of workingWorking continuouslyCooling methodShort-circuit protectionFan-cooledNo automatic recovery, need to restart the machineWorking Environment & Mechanical dimensionDegree of protectionIP20 (indoor) 2500mWorking Altitude(m)Working temperature ( )-15 50 Relative humidity ( )0 90%, No condensation 50dBNoise ( 1 meter)Unit size: (W x D x H)750 750 1485mm1000 1150 1860mmReference weight (Kg)550Kg1050KgOur company can adjust parameter configuration according to user’s requirement.13

Technical ParameterModelSDP-200KWIsolation modeSDP-250KWLow Frequency TransformerDC InputRated voltage (Vdc)Rated current (A)Input voltage range (Vdc)480Vdc540Vdc540Vdc600Vdc417A370A463A417A432 650V486 750V486 750V540 850VAC OutputRated power (Kw)200KW250KW380V 3%380V 3%Number of phases3 phase 4 wire3 phase 4 wireRated current (A)303A379ARated voltageRated output voltage range (V)220/230/240/380/400/415/440/480VAC (optional)Output frequency50Hz or 60Hz 0.05 (Can set)WaveformPure sine waveWaveform distortion rate (THD)Linear load 2%Dynamic Response time(Load 0 100%)5%, 50msPower Factor (PF)0.99Inverter Efficiency 93%Electrical insulation properties2000Vac、1 MinuteProtection FunctionOverload AbilityProtection150%、10sInput reverse polarity, under voltage, overvoltage, output over-current,short circuit, overheating etc.DisplayLCDCommunication interface (optional)RS485 (A、B)Method of workingWorking continuouslyCooling methodShort-circuit protectionFan-cooledNo automatic recovery, need to restart the machineWorking Environment & Mechanical dimensionDegree of protectionIP20 (indoor) 2500mWorking Altitude(m)Working temperature ( )-15 50 Relative humidity ( )0 90%, No condensation 60dBNoise ( 1 meter)Unit size: (W x D x H)Reference weight (Kg)1000 1150 1860mm1150KgOur company can adjust parameter configuration according to user’s requirement.141300Kg

Technical ParameterModelSDP-300KWIsolation modeSDP-400KWLow Frequency TransformerDC InputRated voltage (Vdc)600VRated current (A)500A667A540 850V540 850V300KW400KW380V 3%380V 3%Number of phases3 phase 4 wire3 phase 4 wireRated current (A)454.5A606AInput voltage range (Vdc)AC OutputRated power (Kw)Rated voltageRated output voltage range (V)220/230/240/380/400/415/440/480VAC (optional)Output frequency50Hz or 60Hz 0.05 (Can set)WaveformPure sine waveWaveform distortion rate (THD)Linear load 2%Dynamic Response time(Load 0 100%)5%, 50msPower Factor (PF)0.99Inverter Efficiency 93%Electrical insulation properties2000Vac、1 MinuteProtection FunctionOverload AbilityProtection150%、10sInput reverse polarity, under voltage, overvoltage, output over-current,short circuit, overheating etc.DisplayLCDCommunication interface (optional)RS485 (A、B)Method of workingWorking continuouslyCooling methodShort-circuit protectionFan-cooledNo automatic recovery, need to restart the machineWorking Environment & Mechanical dimensionDegree of protectionIP20 (indoor) 2500mWorking Altitude(m)Working temperature ( )-15 50 Relative humidity ( )0 90%, No condensation 60dBNoise ( 1 meter)Unit size: (W x D x H)Reference weight (Kg)1600 1600 2000mm2300KgOur company can adjust parameter configuration according to user’s requirement.152600Kg

Technical ParameterModelSDP-500KWIsolation modeLow Frequency TransformerDC InputRated voltage (Vdc)600VRated current (A)833AInput voltage range (Vdc)540 850VAC OutputRated power (Kw)500KWRated voltage380V 3%Number of phases3 phase 4 wireRated current (A)757.5ARated output voltage range (V)220/230/240/380/400/415/440/480VAC (optional)Output frequency50Hz or 60Hz 0.05 (Can set)WaveformPure sine waveWave

Pure sine wave output. With good dynamic response less than 50MS, waveform distortion rate smaller, higher conversion efficiency and stable output voltage. Built-in low frequency isolation transformer, strong impact resistance, available with motors, pump, air conditioners and ot

Related Documents:

800VA Pure Sine Wave Inverter’s Reference Design Sanjay Dixit, Ambreesh Tripathi, Vikas Chola, and Ankur Verma ABSTRACT This application note describes the design principles and the circuit operation of the 800VA pure Sine Wave Inverter. The pure Sine Wave inverter has various applications because of its key advantages such as operation

output generated: modified sine wave, and pure sine wave1. A modified sine wave can be seen as more of a square wave than a sine wave; it passes the high DC voltage for specified amounts of time so that the average power and rms voltage are the same as if it were a sine wave.

Pure Sine Wave Power Inverter. Website: www.ato.com Email: sales@ato.com Tel: 1 800 585 1519 . 3 . Pure Sine Wave Power Inverter Applications . ATO pure sine wave inverters output power ranging from 300W to 8000W with full protections against reverse connection, over voltage, under voltage, overload, short circuit, and overheat for your devices.

4. Advantages of a Pure Sine Wave Inverter Today s inverters come in two basic output waveforms: modified sine (which is actually a modified square wave) and pure sine wave. Modified sine wave inverters approxi

encodes a sine wave. The duty cycle of the output is changed such that the power transmitted is exactly that of a sine-wave. This output can be used as-is or, alternatively, can be filtered easily into a pure sine wave. This report documents the design of a true sine wave inverter, focusing on the inversion of a DC high-voltage source.

Again modified sine wave inverters are named after their output waveform. The output of the modified sine wave inverter cycles through positive, ground and negative voltage as shown in the diagram above, to give a similar output waveform to pure sine wave. Modified sine wave inverters are a much cheaper alternative to pure sine wave inverters .

Pure Sine Wave Power Inverter · Applications . ATO-JYP 300W-6000W Pure Sine Wave Inverters deliver the true sine wave power that is the same as the grid power we use every day, ideal for running all kinds of electronics, household appliances, power tools and sensitive loads. 3 . www.ato.com sale@ato.com Global Shipping 1 800 585 1519

MODIFIED SINE WAVE OR PURE SINE WAVE Most Magnum Energy brand series inverters provide pure sine wave power. Run your TVs, stereos, tool battery chargers, computers, and other sensitive electronics without worry. Our pure sine wave inverter chargers provide clean, reliable power with low