Search 30rb 30rq air cooled liquid chillers and reversible air to

Air-Cooled Liquid Chillers Reversible heat pumps 30RB/30RQ 040R-160R Rated cooling capacity 40-160 kW R-32. 2. CONTENTS . must not restrict the unit's air flow. IMPORTANT: Before lifting the unit, check that all enclosure panels and grilles are securely fixed in place. Lift and set

codes regarding electromagnetic compatibility. 2 - GENERAL DESCRIPTION. 2.1 - General Pro-Dialog is an electronic control system to regulate units . of the following types: 30RB air-cooled liquid chillers 30RQ reversible heat pumps. These units have one or two refrigerant circuits. Pro-Dialog controls:

30RB/RQ 039S-160S Air-Cooled Liquid Chiller Reversible Air-to-Water Heat Pump Nominal cooling capacity: 39.7 157.9 kW(30RB) Nominal cooling capacity: 38.3 150.3 kW(30RQ)

275429 - Vanguard Twin Cylinder OHV Liquid-Cooled Engines MS-0750 - Vanguard 3-Cylinder OHV Liquid-Cooled Gasoline Engines MS-1055 - Vanguard 3-Cylinder OHV Liquid-Cooled Diesel Engines Quality Starts With A Master Service Technician Other Briggs & Stratton Commercial Power Repair Manuals: Vanguard Twin Cylinder OHV Liquid-Cooled .

Air Cooled Chiller Air Air 2 Air Air 6 AIR COOLED CHILLERS Air-cooled chillers are refrigeration machines that remove heat from cooling loads using chilled water and reject this heat into the atmosphere using refrigerant. THEY ALL HAVE fans, condenser coils, and compressors. Air-cooled chillers are used to provide cooling for human comfort and electronic equipment as well as industrial process .

Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 80 F chilled water. MAXIMUM SERIES † Air & Water-Cooled † 1/4 to 40 Tons † 20 F to 80 F † Using Non-Ozone Depleting Refrigerants 10 ton air-cooled model 10 ton water-cooled model 2 ton water-cooled model 1 ton air-cooled model

ACH Air-Cooled, Horizontal Air Flow ACV Air-Cooled, Vertical Air Flow ACR Air-Cooled Remote Condenser WCC Water-Cooled Condenser Digit 6 — Chilled Water System P Recirculating System, Tank and Pump M Single Pass Chiller Unit (no tank and pump) Digit 7 — Cabinet Type H Horizontal Low Profile V Vertical Upright

Vanguard Air-Cooled V-Twin Specifications Performance Curves 14 HP Vanguard Air-Cooled V-Twin 16 HP Vanguard Air-Cooled V-Twin 15.0 5.2 Kilowatt 7.5 8.2 9.0 9.7 10.4 111.2 111.9 14.0 13.0 12.0 11.0 10.0 9.0 8.0 7.0 16.0 6.7 6.0 HP 1800 2000 2200 24002600 2800 3000 3200 3400 3600 17.0 12.7 REVOLUTIONS PER MINUTE RATED GROSS BHP MAXIMUM .

EWY Air-cooled chiller, heat pump EWL Remote condenser chiller ERA Air cooled condensing unit EWW Water-cooled chiller, cooling only EWC Air-cooled chiller, cooling only with centrifugal fan EWT Air-cooled chiller, cooling only with heat recovery Refrigerant D R-134a P R-407c Q R-410a Capacity class in kW (Cooling) Always 3 .

AIR-COOLED Air-Cooled chillers utilize plant ambient air to extract heat from the refrigeration circuit. Fan or blowers move the plant air across generously sized finned condenser coils to permit full rated capacity at design conditions. WATER-COOLED Water-Cooled chillers utilize a secondary plant water source such as cooling tower or city .

Air-Cooled Chiller The use of air-cooled chillers in process and comfort cooling applications has been steadily increasing in recent years. The air-cooled chiller has evolved from a packaged product, with few options, to a fully customizable unit that can be tailored to meet specific application and job site requirements. High-efficiency air-cooled

Air-cooled chillers are used to produce chilled water to air-side systems such as primary air fan coil systems, constant air volume systems and variable air volume systems in different zones of the building. An air-cooled screw chiller generally comprises a shell and tube evaporator, an air-cooled condenser with