SHELF LIGHTING Sense Line GenXCOOLRefrigeration & FreezerequipmentShelf lightingHigh efficiecnyPlug-in solutionCinch-Connection-SystemDimmableVarious lenghtsNeutralWhite 1WarmWhiteMeat &Deli 2021-V00 LUMITECH Lighting Solution GmbH Technologiepark 10 A-8380 Jennersdorf Tel 43 (0)3329 90 900 Fax 43 (0)3329 90 900 10 office@lumitech.com www.lumitech.comAll rights reserved. The product may differ from the photos. The technical content corresponds to the conditions valid at the time of going to press and is subject to change without notice.

SHELF LIGHTING Sense Line GenX PRODUCT DESCRIPTION High efficient shelf lighting for cooling and freezer cabinets Ready-to-connect solution available, thanks to our Cinch Connection System High operational performance due to directional lighting, integrated heat andhighly efficient LEDs Excellent product illumination thanks to the combination of SMD LEDs and innovativeoptics Safe-use operation due safety extra-low voltage (SELV) Simple installation with application of FIXING Plates Heat sink profile made of anodised, extruded aluminium LED modules protected against moisture & dust by Conformal coating End caps made of PBT Linear lenses made of Polycarbonate (GWT up to 850 C) Dimming capability TECHNICAL DATA SKETCH 2Supply voltage24 VDCAmbient temperature ta-30 . 30 CMax. surface temperature on profile tc60 CType of protectionIP54 (only with „PROTECTION KIT“)Protection classIIIRisk group (EN 62471:2008)0 APPLICATION 2021-V00 LUMITECH Lighting Solution GmbH Technologiepark 10 A-8380 Jennersdorf Tel 43 (0)3329 90 900 Fax 43 (0)3329 90 900 10 office@lumitech.com www.lumitech.comAll rights reserved. The product may differ from the photos. The technical content corresponds to the conditions valid at the time of going to press and is subject to change without notice.

SHELF LIGHTING Sense Line GenX TECHNICAL DATA ORDER DATATypeLengthNo. ofmodulesColourEfficiencyLuminous fluxPowerCRI91430368LED LE905 NW 6L14-GenX 24V/33mA COS8DY905mm6Neutral White106lm/W510lm4,8W 9091430369LED LE905 WW 6L14-GenX 24V/33mA COS8DY905mm6Warm White96lm/W460lm4,8W 9091430370LED LE905 PM 6L14-GenX 24V/33mA COS8DY905mm6Meat & Deli88lm/W420lm4,8W 9091430318LED LE1200 NW 8L14-GenX 24V/33mA COS8DY1.200mm8Neutral White106lm/W670lm6,3W 9091430319LED LE1200 WW 8L14-GenX 24V/33mA COS8DY1.200mm8Warm White96lm/W610lm6,3W 9091430371LED LE1200 PM 8L14-GenX 24V/33mA COS8DY1.200mm8Meat & Deli88lm/W560lm6,3W 90Art. No.Packaging: 12 pieces/carton, 360 pieces/pallet Luminaires alsoAll typical values for Ta 25 C /- 2 CLuminous flux min. value typ. value – 20%Cool WhiteTolerance mechanical dimensions /- 1mm5000KTolerance electrical data /- 15%Tolerance optical data for CW, NW & WW /-15% (LED Modul @ 60mA string current)Tolerance optical data for PC, BP, PM /-15% (LED Modul @ 100mA string current)Tolerance min. value CRI -1available in all other LUMITECH light colours:Bread & Pastries2400KPasta & Cheese2700K CONVERTEROutput voltagePower converterChain length(luminaires)24 VDC 10 % sum of the typical individual powerof the light engins 20 %120mA: max 21 Module100mA: max 24 Module80mA: max 28 Module60mA: max 33 Module50mA: max 35 Module40mA: max 40 Module33mA: max 42 ModuleSelection of the operating device/protective functionsThe operating device protects the modules against overvoltage, overcurrent, overload andshort circuits.The device must comply with the relevant standards for safe operation in freezerand refrigeration equipment and must be also technically approved by LUMITECH LightingSolution GmbH. Power supply units must ensure the following protective measures: SELV Short-circuit protection Overload protection Overtemperature protection Protection against environmental influences OPTICAL PROPERTIES- LUMINAIRELight Distribution measured at 35 angle 3 2021-V00 LUMITECH Lighting Solution GmbH Technologiepark 10 A-8380 Jennersdorf Tel 43 (0)3329 90 900 Fax 43 (0)3329 90 900 10 office@lumitech.com www.lumitech.comAll rights reserved. The product may differ from the photos. The technical content corresponds to the conditions valid at the time of going to press and is subject to change without notice.

SHELF LIGHTING Sense Line GenX COORDINATES AND TOLERANCES*Meat & DeliPM Meat & Deli*Data refers only to LED MODULES WITHOUT LENS!*Colour shift through the lens is possible onrequest! 4 2021-V00 LUMITECH Lighting Solution GmbH Technologiepark 10 A-8380 Jennersdorf Tel 43 (0)3329 90 900 Fax 43 (0)3329 90 900 10 office@lumitech.com www.lumitech.comAll rights reserved. The product may differ from the photos. The technical content corresponds to the conditions valid at the time of going to press and is subject to change without notice.

SHELF LIGHTING Sense Line GenX COLOUR KEYCodeColourCWNWWWPCBPPMCool WhiteNeutral WhiteWarm WhitePasta & CheeseBread & PastriesMeat & Deli5000K4000K3000K2700K2400Kspecial colourCCT LIFETIME STANDARDS70.000h (L80 B10) EN 60598-1 EN 60598-2-1 EN 62031 EN 62471 EN 60335-2-89 THERMAL BEHAVIOUROperating temperature (operation, no defects)ta-30 . 30 CStorage temperatureTemperature cooling profile 12ts-30 . 60 Ctc-30 . 60 C12Values apply to operation at 100% output, natural convection.If the maximum temperature limits are exceeded, the lifetime of the module willbe greatly reduced or the module may be destroyed. The tc point temperature atthe profile of the light engine should be measured in the thermally stable state andunder operating conditions by means of a temperature sensor or temperaturesensitive sticker (available for example from conrad.com or rs-components.com)in accordance with EN60598-1. The entire profile can be used as the tc point. 5Note Installation should only be conducted by a licensed electrician. Reversing the polarity can damage the product! Make sure the converter has been switched off prior to connecting thelight engine. If this is not observed, the light engine may be damaged! Connection or operation is only permitted when using the specifiedconverters. Higher voltages result in damage to or failure of the lightengine. The user is responsible for correct selection of illumination intensity.Excessive illumination intensity may lead to greying or colour changesof displayed products. 2021-V00 LUMITECH Lighting Solution GmbH Technologiepark 10 A-8380 Jennersdorf Tel 43 (0)3329 90 900 Fax 43 (0)3329 90 900 10 office@lumitech.com www.lumitech.comAll rights reserved. The product may differ from the photos. The technical content corresponds to the conditions valid at the time of going to press and is subject to change without notice.

91430318 LED LE1200 NW 8L14-GenX 24V/33mA COS8DY 1.200mm 8 Neutral White 106lm/W 670lm 6,3W 90 91430319 LED LE1200 WW 8L14-GenX 24V/33mA COS8DY 1.200mm 8 Warm White 96lm/W 610lm 6,3W 90 91430371 LED LE1200 PM 8L14-GenX 24V/33mA COS8DY 1.200mm 8 Meat &

Related Documents:

91430363 LED LE1200 WW 8L14-GenX 24V/80mA ASC8DY 1.200mm 8 Warm White 101lm/W 1540lm 15,2W 90 91430364 LED LE1200 PM 8L14-GenX 24V/80mA ASC8DY 1.200mm 8 Meat & Deli 93lm/W 1410lm 15,2W 90 91430365 LED LE1760 NW 12L14-GenX 24V/80mA

Dec 06, 2016 · COMMERCIAL LIGHTING 01-13 14-29 industrial lighting hazardous area lighting cleanroom lighting INDUSTRIAL LIGHTING street lighting area lighting induction lighting landscape lighting CITYSCAPE LIGHTING 30-51 ballast light sources HID lamps spares price list A

LIGHTING ( DEFINED ) OPEN AREA (ANTI-PANIC) LIGHTING ( UNDEFINED ) HIGH RISK TASK LIGHTING Emergency lighting standards tree. Escape route lighting. 1.Escape Route Lighting The emergency lighting on a route forming part of the means of escape from a point in a building to final exit. 2.Open Area (Anti-panic) Lighting The part of emergency .

Small Lighting controls 20 80/22 21 Small Lighting-only 20 80/22 18 Large Lighting controls 10 80/31 10 Large Lighting-only 10 80/31 7 2013-2014 Small Lighting controls 40 80/16 42 Small Lighting-only 20 80/22 21 Large Lighting controls 30 80/18 33 Large Lighting-only 10 80/31 10 Total 160 80/15 162

Crème de Menthe or Get 27 Top Shelf Creme de Menthe Hot Cinnamon Top Shelf Hot Cinnamon Schnapps Parfait Amour Top Shelf Parfait Amour Pimm’s No.1 Top Shelf Summer Cup No.1 Port Wine Top Shelf Ruby Port Southern Comfort Icon Southern Smooth Top Up Liqueur Kit Vermouth Top Shelf Dry Vermouth IF YOU LIKE YOU WILL ENJOY COMMERCIAL EQUIVALENTS

Connect the communication cable between Distribution Shelf and adjacent Rectifier Shelf (cable provided). . Install other controller communications cables (alarm, LAN, etc.) per Rectifier Shelf Quick Start Guide. Controller in Distribution Shelf. ABB Device Comm cable a. Route cable out of the shelf through the Control Cable Bushing. b.

Quik-Lok Shelving POSITION UPRIGHT Temporarily place one shelf support at any convenient location to properly space uprights. 1 BUILD FROM THE BOTTOM UP Place shelf supports or quick- base (front and back) for lowest shelf only. 2 FIT SHELF OVER SUPPORTS Then add two more supports at the next shelf location, place shelf, and continue up the unit. 3

the health care needs of people with multiple health conditions Mai Stafford, Adam Steventon, Ruth Thorlby, Rebecca Fisher, Catherine Turton and Sarah Deeny Key points As the number of people with multiple health conditions grows, meeting their needs will be one of the biggest challenges facing the NHS. In 2006/07, one in 10 patients admitted to hospital as an emergency had 5 conditions .