Liebert CRVfrom 10 to 60 kWEfficient Cooling for IT Equipment

LIEBERT CRV from 10 to 60 kWVertiv Vertiv designs, builds and services mission critical technologies that enable the vital applications fordata centers, communication networks, and commercial and industrial environments. We supporttoday's growing mobile and cloud computing markets with our portfolio of power, thermal, infrastructuremanagement products, software and solutions, all complemented by our global service network.Bringing together global reach and local knowledge, and our decades-long heritage including brandslike Chloride , Liebert and NetSure , our team of experts is ready to take on your most complexchallenges, creating solutions that keep your systems running—and your business moving. Together,we’re building the future of a world where critical technologies always work.YOUR VISION, OUR PASSION.VertivCo.comLiebert CRV Row-Based CoolingThe Liebert CRV, row-based cooling unitis optimized to ensure maximum coolingcapacity in a minimal footprint. Targetedfor small and medium data centers, theunit provides cooling at the server racklevel.The Liebert CRV has been designed todeliver the highest efficiency andavailability, by removing heated air fromthe data center hot aisles, using it toreturn cooled air to the servers (coldaisle). The Liebert CRV is available inDirect Expansion, as well as Chilled Waterversions and in two frame widths - 600mm and a compact 300 mm. Providingfull capacity and airflow modulation tomatch the servers' load, the unit is able todeliver energy savings via its compressorwith capacity modulation, ElectronicExpansion Valve and variable speed ECFans. The Liebert CRV is acomprehensive row-based solution thatincludes all of the main functionsfundamental to cooling units, such ascooling, humidification, dehumidification,re-heating, air filtration, condensationmanagement, temperature and humiditycontrol, alarm functions and datacommunications.Furthermore, the unit enhances itsperformances and energy efficiencythrough the Vertiv ICOM Control,capable of optimizing unit operations byleveraging on its intelligent managementof system components. All componentsare easily accessible from the front andthe rear of the unit, granting simplifiedservice intervention.The unit also allows ease of installation,through simplified cable and pipesrouting from top and bottom of the unit.Liebert CRV 300 mm DX2

Designed to Optimize IT PerformanceThe Liebert CRV, self-containedThermal Management unit is idealfor the cooling of data center rackrowsThe Liebert CRV is a multi-option,precision air conditioner that deliverstemperature and humidity control, aswell as filtration and notificationmanagement, ensuring that data centertemperatures are maintained at anoptimum level.The unit is designed to continuouslymonitor variations in heat loads andinstantly deliver the most efficient andeffective cooling necessary.Liebert CRV: Simple, Safe,AdaptableThe Liebert CRV is a plug-and-play unitwith the capability of addressing theneeds of both open and containedapplications.Cooling is provided at the server racklevel rather than the room level. TheLiebert CRV removes and filters hot airfrom the data center aisles, using it toreturn cooled air to the servers.The integrated air diffusers accuratelydirect the airflow towards the necessarydirection of the heat load.Furthermore, Liebert CRV is designed tocomply with mission-criticalrequirements and ensure that serversare maintained at the correcttemperature and humidity levels.The Liebert CRV provides the exactlevel of cooling required by servers,modulating the airflow and coolingcapacity.The unit is available in two versions tomeet various installation demands:FEATURES ANDPERFORMANCE Units ranging from 10 to 60kW with chilled water anddirect expansion versions Industry's highest energysaving levels achieved increase of up to 50% whenthe Liebert CRV is combinedwith Vertiv SmartAisle cold aisle containment Best-in-class ThermalManagement unit forrow-based applications On-site adjustment capabilityof air diffuser distributiondirection maximizes coolingresults Integrated Vertiv ICOM Control for management ofcapacity and airflow throughEC Fans and variable capacityCompressor Ideal for scalable ITinfrastructure - increasedcooling capacity, reducednoise levels and enhancedefficiency when compared withsimilar chilled water and directexpansion configurations. A stand-alone, direct expansionsystem with variable capacity up to36 kW, available in both 300 mm and600 mm versions, complete with roofor wall-mounted condenser A chilled water system with up to 60kW of capacity available in both 300mm and 600 mm versions.3

LIEBERT CRV from 10 to 60 kWEnsuring Availability Under All Working ConditionsMaintaining IT InfrastructureAvailabilityWith integrated Vertiv ICOM Control,the Liebert CRV is able to monitorvariations in temperature and humidity,instantly adapting its performance tomeet variations in load conditions.This furthermore ensures increasedavailability and safety of protected ITequipment.The Liebert CRV's constanttemperature monitoring and controlcapabilities ensure the availability ofservers in all working conditions.Furthermore, its parallel load sharingfunctionality enables the managementof N 1 configurations.Meeting Primary IT RequirementsThe Liebert CRV's ability to modulatecapacity allows for constant, accurateroom temperature and humidity levelsto be maintained.The variable capacity capability of theLiebert CRV, contributes to increasingdata center availability during bothstandard operations and in the event ofload variations.A reduction in its start/stop cyclingfunction further contributes toincreasing data center availability, aswell as lengthening the life of criticalcomponents.The integrated compressors withcooling capacity modulation aredesigned to avoid peaks in absorbedpower, thus reducing the stress placedon components. The Liebert CRV usesa dedicated control that also enablesthe compressor to operate when theexternal air temperature increasesabove standard limits.Extreme Flexibility for Open and Closed ArchitecturesSuitable For a Wide Range of InstallationsThe Ideal AirflowThe Liebert CRV addresses the cooling needs of both new and existing data centerspace, regardless of raised floor availability. It is ideally suited to data centers with upto 50 racks, irrespective of heat load.EC Fans and compressors with variablecooling capacity, managed throughintegrated Vertiv ICOM Control,achieve flexible capacity and airflow forthe ideal operating conditions of ITequipment.The Liebert CRV, designed usingadvanced, computer-aided dynamic fluidtechnology, delivers optimum airdistribution across rack installations. Theexceptional levels of air distribution havebeen proven as a result of wide-scalelaboratory and field testing.Configuration FlexibilityThe Liebert CRV can be configured to perform temperature as well as humiditycontrol. The Liebert CRV 300 mm and 600 mm width versions have been designed tospecifically meet the requirements of data centers in need of optimizing spaceoccupancy, as well as capital and running costs.4

Optimizing Total Cost of OwnershipDelivering Optimized ResultsEnergy Efficient CoolingIdeally suited for rack-level cooling and specifically designed for high return airtemperatures, the Liebert CRV optimizes air distribution and maximizes efficiency,delivering both cost and energy-related savings.Efficiency is further enhanced through the use of the environmentally friendly R410Arefrigerant which ensures constant operation at the highest efficiency levels.The Liebert CRV is also designed to optimize installation and minimize start up,connection and labor investments. The unit is available for integration with existingracks or as a bundled solution combined with racks, UPS and monitoring capabilities.The integrated Vertiv ICOM Control,equipped with up to 10 racktemperature sensors, continuouslymonitors the heat load of the racks andregulates the Liebert CRV, ensuring itprovides the most effective level ofcooling while at the same time deliveringenergy savings. Variable capacitycompressors modulate the coolingcapacity, thus reducing input power withpartial loads. EC Fan technologyregulates airflow and reduces fan inputpower.Customer Monitoring InterfacesMonitoring and Control Through Existing Network Via your Web BrowserThe Liebert CRV system can be fitted with a Vertiv monitoring card allowing fulladvantage to be taken of the Ethernet network and remote monitoring from yourcomputer desktop, network operations center or any network access simply utilizing astandard web browser. A standard web browser, via HTTP protocol or NetworkManagement System software via SNMP protocol, can be used to access the unitinformation.Monitoring Integration withExisting Building ManagementSystemIf required, by installing the optionalmonitoring card, the Liebert CRV can bemonitored and controlled by an existingBuilding Management System.The monitoring card provides Modbus,Bacnet and SNMP protocol support.5

LIEBERT CRV from 10 to 60 kWData Center Rooms with up to 10 RacksThe Liebert CRV is installed in close proximity to servers for installations relating to network access cabinets and small computerrooms, regardless of the presence of a raised floor. The cooling unit, equipped with ten temperature sensors, modulates the airflowto match the real-time cooling requirements of the server.Direct Expansion SolutionWhen a chilled water system andphysical building limitations restrict theinstallation of chillers, a direct expansionsolution is the ideal choice.In the event that internal and externalunits are installed in close proximity,direct expansion units are able to deliversignificant reductions in installationrelated time and costs. One of theScenario16N of RacksHeat LoadSpaceRaise FloorRecommended Solutionadvantages of the Liebert CRV with adirect expansion solution is theeco-friendly refrigerant R410A. The unitalso offers variable capacity compressor,which has the capability of immediatelymodulating and adapting its operationaccording to server coolingrequirements. It significantly minimizesstart/stop cycling, extending the lifecycle of your cooling equipment. The1 to 4Up to 20 kWFrom 5 m2 and 15 m2-Direct ExpansionScenario2Liebert CRV, operates with a significantreturn air temperature, which contributesto maximizing cooling capacity andincreasing efficiency without placingadditional stress on compressors.N of RacksHeat LoadSpaceRaise FloorRecommended SolutionUp to 10Up to 100 kWUp to 30 m2-Direct Expansion

Data Center Rooms with up to 50 RacksThe Liebert CRV's integration with Vertiv SmartAisleTM proves to be the ideal cold aisle containment approach for small datacenters requiring heat density increases. This solution has the added advantage of avoiding the installation of raised floors orheightening roof levels.Chilled Water Solution with Vertiv SmartAisle The Vertiv SmartAisle separates hotreturning air and cold supply air,optimizing the entire cooling solution. Byincreasing the room temperature, thefloor-mounted cooling units can besignificantly downsized, reducing theoverall level of investment. The higherEnergy Efficiency Ratio also improvesenergy savings and dramatically reducesrunning costs. The solution delivers thebest results when combined with theLiebert HPC - maximizing thefreecooling effect and reducing runningcosts.Scenario3N of RacksHeat LoadSpaceRaise FloorRecommended SolutionCombining the Liebert CRV withthe Liebert HPC FreecoolingChiller for Increased AdvantagesChilled water solutions are optimized toreduce energy consumption: With the use of EC Fans and theunit’s close proximity to the racks,the Liebert CRV minimizes fan powerinput and can be regulated based onserver load levels. As it is specifically designed for high10 to 20Up to 200 kWUp to 50 m2-Chilled Waterreturn air temperatures, the LiebertCRV can operate at high chilledwater temperatures while maintainingcapacity, thus maximizing the chillerfreecooling effect.Scenario4N of RacksHeat LoadSpaceRaise FloorRecommended SolutionUp to 50Up to 300 kWUp to 100 m2-Chilled Water7

LIEBERT CRV from 10 to 60 kWLiebert CRV Technical DataDIRECT EXPANSION (DX) MODELSCR012RANet Sensible Cooling Capacity [kW]Nominal Airflowm3/hWeight[kg]Humidity ControlDimensions H x W x D[mm]CHILLED WATER (CW) MODELSCR025RA CR020RA/W CR035RA/W14.022.532004000215260NoYes2000x300x1100 (*)CR030RC24.237.741705540335 / 350365 / .057.072007758230230NoYes2000x300x1100 175Note: The performances shown above refer to an air inlet temperature of 38 C, condensing temperature for air and water-glycol cooled units of 45 C and a chilled water temperature of 7/12 C. (*) Unit available alsowith a 2200 mm height and 1200 mm depth.STANDARD FEATURES AND OPTIONSDX VersionCW Version High Efficiency Scroll/RotaryH Compressor with Capacity ModulationElectronic expansion valveEC plug fansR410A RefrigerantAdjustable modular baffle systemTop/Bottom connectionsLevelling feetFilters with up to F5 filtration classand clog filter switchElectrode humidifierElectric reheat 1-stageInternal condensate pumpUser Friendly DisplayRemote rack temperature sensorsMonitoring card for WEB, Modbusand BACnetTeamworking functionality EC plug fans 3-way or 2-way valve with 0-10V actuatorAdjustable modular baffle systemTop / Bottom connectionsLevelling feetFilters with up to F5 filtrationclass and clog filter switchElectrode humidifierElectric reheat 1-stageInternal condensate pumpUser Friendly DisplayRemote rack temperature sensorsMonitoring card for WEB,Modbus and BACnetTeamworking functionalityDW8ADDITIONAL OPTIONSLiebert CRV 300 mm CWDX VersionCW Version Additional remote rack temperature Additional remote rack temperaturesensors Compressor jacket (600 mm models) Dual power supply with ATS onselected modelssensors Dual power supply with ATS Cooling capacity meter

Coupling Air Cooled Liebert CRV Units with Air Cooled CondensersModelAmbient Temperature up to 35 CAmbient Temperature up to 40 CAmbient Temperature up to 46 CStandard NoiseLow NoiseStandard NoiseLow NoiseStandard NoiseLow Noise1 x HCR171 x HCR331 x HCR331 x HCR511 x HCR331 x HCR431 x HCR431 x HCR591 x HCR331 x HCR431 x HCR431 x HCR511 x HCR431 x HCR511 x HCR511 x HCR591 x HCR431 x HCR511 x HCR511 x HCR761 x HCR511 x HCR591 x HCR591 x HCR88CR012RACR025RACR020RACR035RACondensers 3102136165[mm] / [kg][mm] / [kg][mm] / [kg][mm] / [kg][mm] / [kg][mm] / [kg][mm] / [kg]Coupling Water/Glycol Cooled Liebert CRV Units with DrycoolersModelCR20RWCR35RWAmbient Temperature up to 30 CAmbient Temperature up to 35 CAmbient Temperature up to 40 CStandard NoiseLow NoiseStandard NoiseLow NoiseStandard NoiseLow Noise1 x ESM0181 x EST0281 x ELM0181 x ELM0271 x EST0281 x EST0501 x ELM0271 x ELT0551 x EST0501 x EST0701 x ELT0471 x ELT065Dry Cooler 02CHILLED WATER COOLINGChilled water cooling units may be coupled with Vertiv chillers (LiebertHPC or Liebert AFC series). The Liebert HPC chiller series offers a widerange of air cooled or water cooled solutions. Available with various noisethresholds and with freecooling modes, these units significantly enhancethe system's energy saving capabilities. Liebert HPC freecooling chillersare available from 40 kW to 1600 kW. The Liebert AFC, AdiabaticFreecooling Chillers, are available from 500 kW to 1700 kW and aredesigned to maximize data center efficiency and availability.9

LIEBERT CRV from 10 to 60 kWThermal Management Data Center Infrastructure for Small and Large ApplicationsLiebert HPCWide range of high efficiency Freecooling Chillersfrom 40 kW to 1600 kW Designed specifically for data center applicationsand to work with Vertiv SmartAisle Premium energy efficiency versionUnique control capabilities with the VertivICOM Control.Liebert PDXLiebert PCWAvailable from 5-220 kW Premium energyefficiencyEurovent certifiedperformanceUnique controlcapabilities with theVertiv ICOM ControlLiebert EconoPhase available for the directexpansion system.Vertiv Trellis PlatformLiebert EFCIndirect evaporative freecooling unit leveraging on datacenter know-how. Available from 100 to 450 kW 10Unique control capabilities optimizing water andenergy costsSubstantial reductions and savings in terms ofelectrical infrastructure.Vertiv’s Trellis TM platform is a real-time infrastructure optimization platform that enables theunified management of data centre IT and facilities infrastructure. The Vertiv Trellis platformsoftware can manage capacity, track inventory, plan changes, visualize configurations, analyzeand calculate energy usage, and optimize cooling and power equipment. The Vertiv Trellisplatform monitors the data center, providing a thorough understanding of system dependenciesto help IT and facilities organizations keep the data center running at peak performance. Thisunified and complete solution, delivers the power to see the real situation in your data center,make the right decision and take action with confidence.

SERVICESLiebert AFCThe Adiabatic Freecooling Chiller availablefrom 500-1700 kW Integrated adiabatic pad system High freecooling capacity 100% compressor back up.Vertiv SmartAisle Aisle containment Provides highest energyefficiency Works with any Liebert ThermalManagement unit.Vertiv supports entire criticalinfrastructures with the largestglobal service organization and anextensive service offering,enhancing network availability andensuring total peace of mind 24/7.Our approach to servicing criticalinfrastructure covers all aspects ofavailability and performance: fromsingle power and thermalmanagement equipment to entiremission-critical systems.The most comprehensiveinsurance for business protectioncan be obtained with a serviceprogram from Vertiv whichincludes access to Vertiv LIFE Services.VERTIV LIFE SERVICESLiebert CRVRow-based high efficiency cooling units availablefrom 10-60 kW in DX and CW versions Full airflow and cooling capacity modulation tomatch server load and to save energy Best footprint capacity with the highest efficiency Six different control modes to ensure greaterflexibility.Liebert DCLClosed loop rack cooling Two different architectures:Closed LoopHybrid Loop Multiple combinations for up to 4 serverracksAvailable as direct expansion or chilled waterversion Vertiv LIFE Services providesRemote Diagnostics andPreventive Monitoring for UPSand thermal managementequipment.Vertiv LIFE Services deliversincreased uptime and operationalefficiency by enabling continuousmonitoring of your equipment,expert data analysis and fieldengineering expertise.Through the data transferred fromyour equipment via Vertiv LIFEServices, our Remote experts gainthe real-time insight andinformation needed to quicklyidentify, diagnose, and resolve anyirregularities that may arise inoperation, ultimately takingresponsibility for your criticalassets 24/7.11

VertivCo.com Vertiv Infrastructure Limited, George Curl Way, Southampton, SO18 2RY, VAT Number: GB188146827 2018 Vertiv Co. All rights reserved. Vertiv , the Vertiv logo, Liebert CRV, Liebert HPC, Liebert ACF, Vertiv SiteScan , Vertiv ICOM , Vertiv IntelliSlot , Vertiv SmartAisle , Vertiv Nform and Vertiv LIFE Services are trademarks or registered trademarks ofVertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. Assumes no responsibility, anddisclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice.MKA4L0UKCRV Rev. 5-12/2018

The Liebert CRV, self-contained Thermal Management unit is ideal for the cooling of data center rack rows The Liebert CRV is a multi-option, precision air conditioner that delivers temperature and humidity control, as well as filtration and notification management, ensuring that dat

Related Documents:

Liebert GXT 10kVA, Liebert GXT2U and Liebert Nfinity Liebert IntelliSlot Web Card-LB - compatible with: Liebert NX and Liebert Hinet UPS models Liebert IntelliSlot Web Card-LBDS - compatible with these Precision Cooling units: Liebert DS , Liebert X

Liebert HPC L . Liebert HPC S . Emerson’s Thermal Management Data Centre Product Portfolio . Liebert CRV Liebert XDV . Liebert PCW Liebert PDX Digital Scroll XDH. Evaporative Air Handlers/Room . Cooling . Knürr DCD Knürr DCL . 35 . Liebert DM . Liebert HPS . Rack and . In Row . Liebert DSE . Room/Perimeter

Liebert Nform Software Frequently Asked Questions Yes, by adding the Liebert MultiLink shutdown license, Liebert Nform can be setup to send shutdown commands to Liebert MultiLink 1.5 clients. Yes. Liebert can custom build templates for your UPSs to work with Liebert Nform. No, Liebert Nform c

Aug 01, 2019 · Liebert EconoPhase pumped refriger-ant economizer) increasing its ability to adapt to diverse application demands. The Liebert EconoPhase pumped refrigerant economizer is compatible with Liebert PDX and Liebert MC to improve thermal management and control,

Liebert NXr Series 30KVA to 200KVA (380V) 2 Today, you need a power infrastructure . Liebert NXr to provide the same level of reliability you have come to expect from the Liebert NX UPS series. 4 The best investment you can make in a UPS system: Efficiency, . Liebert NXr Liebert NXr Li

The Liebert GXT3-5000RT208, Liebert GXT3-6000RT208 and the Liebert GXT3-6000RTL630 contain no user-serviceable parts except the internal battery pack. The Liebert GXT3-10000RT208 and the Liebert GXT3-8000RT208 contain no user-serviceable parts except the internal battery pack and the Power Module.

Liebert PDX Floor-Mount Unit Liebert MC Microchannel Condenser Liebert EconoPhase Economizer The Liebert EconoPhase pumped refrigerant economizer is compatible with the Liebert PDX and Liebert MC to improve thermal management and control, while drastically cutting energy costs and lowering p

The Liebert DSE direct expansion cooling system comprises four primary components: the Liebert DSE indoor computer room air conditioning (CRAC) unit, the Liebert MC micro-channel outdoor condenser, the Liebert EconoPhase pumped refrigerant economizer and Liebert iCOM control with thermal syste