PRODUCT CATALOGFuel ManagementSystemsConsoles, Probes & SensorsTank & Line Leak DetectionFuel Management SoftwareBiofuel Approved Components(E85 & Biodiesel)US & Canada

FUEL MANAGEMENT SYSTEMSContentsTable of ContentsFuel Management Systems Consoles . 1TS-5 . 2TS-5000/550 . 4Tank Sentinel Consoles . 8TS-1001/2001 . 9TS-504/508 . 11TS-1001/G . 13TS-750 . 15Console Hardware & Software Enhancements . 17Electronic Line Leak DetectorsTS-LS300 AutoLearn . 18TS-LLD . 20Probes and SensorsLeak Detection and Inventory Control Probes. 22Moorman Level Gauge . 24Float Kits . 25Install Kits . 26TSP-EIS Leak Detection Sensor . 28TSP-ULS Leak Detection Sensor. 29TSP-HLS Leak Detection Sensor. 30TSP-DIS Leak Detection Sensor . 31TSP-DDS Leak Detection Sensor . 32TSP-DTS Leak Detection Sensor . 33TSP-DVS Leak Detection Sensor . 34TSP-HIS Leak Detection Sensor . 35TSP-MWS Leak Detection Sensor . 36Sensor Installation Accessories. 37AccessoriesTS-DIM External Console Hardware Accessory . 401

FUEL MANAGEMENT SYSTEMSContentsTable of Contents (cont.)TS-TPI External Console Hardware Accessory . 42TS-SEM External Console Hardware Accessory . 43TS-ROM External Console Hardware Accessory . 44TS-CIM External Console Hardware Accessory . 45TS-RA1 External Console Hardware Accessory. 46TS-RA2 External Console Hardware Accessory. 47TS-RK Exteranl Console Hardware Accessory . 48TS-M External Console Hardware Accessory . 49External Console Hardware Accessories . 50Power Sentinel . 51System Sentinel . 53System Sentinel AnyWare . 55Get Connected AnyWare . 57System Sentinel Tech Edition . 59Paper Supplies and Additional Documentation . 59Sump Test System Kit. 60INCON Technician Certification . 62Upgrading Installed Tank Sentinel and FMS Consoles . 63Spare PartsTS-5XXX Console Spare Parts . 64TS-LS500 Spare Parts . 64TS-LLD Spare Parts . 64TS-1001 Console Spare Parts . 65TS-2001 Console Spare Parts . 65TS-LS300 Spare Parts . 66TS-504/750 Console Spare Parts . 66TS-508 Console Spare Parts . 67TS-STS Sump Test Kit Spare Parts . 67Part Number Quick Reference. 682

Fuel ManagementSystems ConsolesFUEL MANAGEMENT SYSTEMSOrdering Consoles from the FactoryFORMAT: The Tank Sentinel part number is divided into three sections: Model, Hardware Options/Software Options.EXAMPLE: T550D/TL (TS-550 with a display, tank testing, line leak detection option).ModelThe following table shows the values that the Model section can assume.MODEL OF TANK GAUGEVOLTAGEPART NUMBER CODETS-5110 or 220 VACT5TS-550110 or 220 VACT550TS-5000110 or 220 VACT5000Notice: The order of specific option in the table determines position in the finalpart number.HardwareThe following table shows the values that the Hardware section can assume.HARDWAREOPTION esYesInternal ModemMYesYesYes*LON Module (EcheLON)EYesYesYes*Dispenser Interface ModuleIYesYesYes*Either a LON Module or a Dispenser Interface Module can be installed per console.SoftwareThe following table shows the values that the Software section can assume.SOFTWAREOPTION CODETS-5TS-550TS-5000Tank Testing(includes Static & SCALD)TStatic Std.SCALD Opt.YesYesReconciliationRYesYesYesLine Leak DetectionLNoYesYesVapor Recovery MonitoringVNoYesYesSecondary Containment MonitoringSNoYesYes1

Fuel ManagementSystems ConsolesFUEL MANAGEMENT SYSTEMSTank Sentinel - Automatic Tank Gauge TS-5The INCON automatic tank gauge provides inventory and leak detection for up totwelve storage tanks.FeaturesCan monitor up to 12 tanks.Continuous inventory monitoringand tank testing through provenmagnetostrictive probe technology.Highest rated continuous 24 hour leakdetection (SCALD) in the industry.Low cost, compact console.Standard communication portsincluding Ethernet, (2) RS-232 and USB.Internal fax and data modem options.Generates inventory, compliance andfuel management reports.CapabilitiesThe automatic tank gauge is built onan established open system softwareplatform.Standard Ethernet connection allowseasy integration to existing wide areanetworks.XML based software allows access todata remotely without the need of additional software.ApplicationsGraphical touch screen LCD allows textto be displayed in native language.The automatic tank gauge has been designed to monitor tank tightness and gatherinventory information.E-mail notification gives station ownersreal-time status information.Third party approved volumetric leakdetection (Pd 99.9% at 0.2 gph).Can provide dispenser information andautomate reconciliation when used inconjunction with the Dispenser InterfaceModule.2Provides accurate inventory information,including reports that can be used tobetter schedule deliveries.Multipurpose relays which can be usedfor outputs to overfill alarms and external audible and visual indicators.

FUEL MANAGEMENT SYSTEMSFuel ManagementSystems ConsolesTS-5 SpecificationsNumber of tanks monitored12Input channels2Output only channels2Display typeTouch screen LCDApplicable liquidsPetroleum, chemicals and hazardous wasteLevel unitsInches, centimeters and millimetersVolume unitsGallons or litersDisplay size320 240 pixelsPower requirements110-220 VAC, 15%, -10%, 150 Watt maximum,1.5 AmpOperating temperature32 to 104 F (0 to 40 C)Storage temperature-4 to 140 F (-20 to 60 C)Intrinsic Safety RatingUS: Class I, Div. I, Group DEurope: Group IIA, Zone 0MODELDESCRIPTIONT5DTS-5 console with LCD DisplayNote: Includes one TS-PRB (12 input probe module).Fixed Feature Modular ConsoleSoftware & Hardware OptionsThe TS-5 console comes standard with the ability to perform in-tank leakdetection. The following software and hardware options can be added tocustomize your consoles. The Internal Hardware Options will be factory installedwhen ordered with the console.PART NUMBERDESCRIPTIONInternal Software OptionTS-TT(T) Statistical Continuous Automatic Leak Detection,24 Hour Continuous Tank Testing SoftwareTS-TRAC(R) Tank Inventory Reconciliation and Auto CalibrationInternal Hardware OptionTS-DIMIB(I) Internal Dispenser Interface Module(Dispenser Interface Cable must be ordered separately)TS-LON(E) EcheLON Communication Module(IFSF protocol capability)TS-MDMIB(M) Internal Modem(Includes fax and data software capability)Note: Only one TS-DIMIB or TS-LON module can be installed per console.3

Fuel ManagementSystems ConsolesFUEL MANAGEMENT SYSTEMSTank Sentinel - Automatic Tank GaugeTS-5000/550The INCON fuel management system’s modular design provides compliance andfuel management capability in a single enclosure.FeaturesCan monitor up to 72 tanks.Continuous inventory monitoringand tank testing through provenmagnetostrictive probe technology.Highest rated continuous 24 hour leakdetection (SCALD) in the industry.Patented AutoLearn electronic lineleak detection capability.Standard communication portsincluding Ethernet, (2) RS-232 and USB.Internal fax and data modem options.Interstitial and piping sump leaksensing for up to 72 sensors.Can handle 72 dispenser hook inputseliminating need for external box.CapabilitiesThe INCON fuel management systemis built on established open systemsoftware platform.ApplicationsThe flexible architecture of the INCON fuel management system allows multiple applicationsto run concurrently satisfying current and future business and regulatory requirements.Fuel management system applicationsprovide accurate inventory information,third party approved tank and lineleak detection, automated inventoryreconciliation and submersible pumpmonitoring.The Vapor Recovery Monitoringapplication gauges the effectiveness ofa station’s vapor recovery equipmentthrough continuous monitoringof gasoline vapors during fuelingoperations.Secondary Containment Monitoringapplication continuously monitors theinterstitial spaces of double wall tanks,lines and sumps, and notifies stationowners when a release of product intothe environment has occurred.Standard Ethernet connection allowseasy integration to existing wide areanetworks.XML based software allows access todata remotely without the need ofadditional software.Graphical touch screen LCD allows textto be displayed in native language.Generic interface modules giveflexibility in configuring stationmonitoring requirements.E-mail notification gives station ownersreal-time status information.Multiple printing options giveflexibility in style and format ofreports.4

FUEL MANAGEMENT SYSTEMSFuel ManagementSystems ConsolesTS-5000/550 SpecificationsIntrinsic Safety RatingUS: Class I, Div. I, Group DEurope: Group IIA, Zone 0Operating temperature32 to 104 F (0 to 40 C)Storage temperature-4 to 140 F (-20 to 60 C)Power requirements110-220 VAC, 15%, -10%, 150 Watt maximum,1.5 AmpMODELDESCRIPTIONTS-5000 110 VAC & 220 VAC ModelsT5000TS-5000 base console, without display and printerT5000DTS-5000 base console, with display and without printerT5000DPTS-5000 base console, with display and printerTS-550 110 VAC & 220 VAC ModelsT550TS-550 base console, without display and printerT550DTS-550 base console, with display and without printerT550DPTS-5000 base console, with display and printerExpansion ConsoleTS-EXPCSecondary Console to add eleven additional plug-in modules toprimary TS-5000/550 console. No display or printer.Full Feature Modular Console Software& Hardware OptionsThe TS-550 and TS-5000 consoles comes standard with the ability to monitorinventory levels. The following software and hardware options can be added tocustomize your consoles. The Internal Hardware Options will be factory installedwhen ordered with the console.PART NUMBERDESCRIPTIONInternal Software OptionTS-TT(T) Tank Testing Software (Includes Static and SCALD)TS-TRAC(R) Tank Inventory Reconciliation and Auto CalibrationTS-ELLD(L) Electronic Line Leak DetectionTS-SCM(S) Secondary Containment MonitoringInternal Hardware OptionTS-DIMIB(I) Internal Dispenser Interface Module (Dispenser Interface Cablemust be ordered separately)TS-LON(E) EcheLON Communication Module (IFSF protocol capability)TS-MDMIB(M) Internal Modem (Includes fax and data software capability)Note: Only one TS-DIMIB or TS-LON module can be installed per console.5

FUEL MANAGEMENT SYSTEMSFull Feature Modular ConsolesInterface ModulesThe TS-550 and TS-5000 consoles come standard with a Power Supply Moduleand a Controller Module. Additional interface modules can be installed. Interfacemodules ordered with a TS-550/5000 console will be installed in the console at thefactory. The following guidelines must be followed:TS-5000: Eleven total modules can be installed with a maximum of nineintrinsically safe modules, a maximum of three of any one kind of module.TS-550: Six total modules can be installed with a maximum of four intrinsicallysafe modules, a maximum of three of any one kind of module.Intrinsically Safe ModulesPART NUMBERDESCRIPTIONTS-PRB12 Input Probe Module (LL2 Series Mag Probesand VFM Series Flow Meters)TS-2WSNS12 Input 2-wire Sensor Module (TSP-ULS and TSP-HLS Sensors)TS-3WSNS8 Input 3-wire Sensor Module (TSP-EIS, DIS, DDS, DTS,HIS and DVS Sensors)TS-420IB8 Input 4-20 ma Module (LSU500 Transducersand VPS & VCM Series Pressure Sensors)Non-Intrinsically Safe ModulesPART NUMBERDESCRIPTIONTS-ACI12 Input AC Input Module (Dispenser Hook Inputs)*TS-RLY8 Input Relay Output Module (VCM Series Solenoid)TS-LS500 AutoLearn Pressurized Line Leak Detection provides automatic 3.0 gph hourly, 0.2 gphmonthly and 0.1 gph annual precision line leak detection for TS-550 and TS-5000consoles. A TS-420IB, TS-ACI and TS-RLY modules and TS-ELLD software option mustbe ordered and installed in tank gauge console.PART NUMBERDESCRIPTIONTS-LS500/22-line transducer kitTS-LS500/33-line transducer kitTS-LS500/44-line transducer kitNote: Using Turbine Pump Interface (TPI) communications eliminates the need for a TS-RLYmodule (FFS intelligent controllers required).6Fuel ManagementSystems Consoles

FUEL MANAGEMENT SYSTEMSFuel ManagementSystems ConsolesDispenser Interface Module CablesPART NUMBERDESCRIPTIONTSP-WDCBLWayne DIM CableTSP-TDCBLTokheim DIM CableTSP-GDCBLGilbarco DIM CableTSP-GSDCBLGilbarco G-Site DIM CableSecondary Containment MonitoringThe Secondary Containment Monitoring system is designed to detect leaks indouble-walled tanks, sumps and piping. A TS-420IB, TS-RLY module, TS-ACI andTS-SCM software option must be ordered and installed in the tank gauge console.Sensor ModulesPART NUMBERDESCRIPTIONTS-SCCM/1Single Secondary Containment Control ModuleTS-SCCM/2Double Secondary Containment Control ModuleTS-SCMCALLeak Generator Kit (one per station)Install KitPART NUMBERDESCRIPTIONTSP-SCLSIProduct/Vapor Line/Sump Containment Install KitTSP-SCTKITank Containment Install Kit (in tank hose sold separately)AccessoriesPART NUMBERDESCRIPTIONTSP-SCTB2525 foot hoseTSP-SCTB5050 foot hoseTSP-SCTB100100 foot hoseTSP-SCCLPFive hose clampsTSP-SCVLVFive Schraeder valvesTSP-SCBRBFive ¼” NPT barbed fittingsTSP-SCBRBT¼” NPT barbed T fitting7

Tank Sentinel ConsolesFUEL MANAGEMENT SYSTEMSOrdering Consoles from the FactoryFORMAT: The Tank Sentinel part number is divided into three sections: Model, Hardware Options/Software Options.EXAMPLE: T2P/8S (TS2001 with a printer option/software SCALD option that supports eight tanks).ModelThe following table shows the values that the Model section can assume.MODELVOLTAGEMODEL CODETS-1001120 VACT1TS-1001220 VACV1TS-2001120 VACT2TS-2001220 VACV2TS-504120 VACT504TS-504220 VACV504TS-508120 VACT508TS-508220 VACV508TS-750120 VACT750TS-750220 VACV750HardwareThe following table shows the values that the hardware section can assume. Note that theorder of the specific option in the final part number is fixed. The order of the options in thetable reflects this (i.e. P will always be before M).HARDWAREOPTION CODETS-1001TS-2001PrinterPStd.Std.Internal ModemMYesYes1 or 2NoYesNoInternal Expansion ice: The order of specific option in the table determines position in the final part number. ALLoptions except the Internal Expansion Module are determined by a setting programmed into the IDchip. Internal Expansion Modules is determined at power up via presence of hardware module(s).SoftwareThe following table shows the values that the software section can assume. Note that theorder of the specific option in the final part number is fixed. The order of the options in thetable reflects this (i.e. 8 will always be before S, which should always be before D).SOFTWAREOPTION CODETS-1001TS-2001TS-504TS-508TS-7500, 2, 4, 80, 2, 48481, 2, 3, 4SCALD or GeneratorS, GYesSNoNoSData Fax/Data ModemD, FYesYesYesYesYesNumber of tanksContinental versionCYesYesYesYesYesLine Leak sNoNote:The order in the table determines the part number.SCALD and Generator options are mutually exclusive. The SCALD option is not needed for thegenerator model.Data and Fax/Data Modem options are mutually exclusive.8

Tank Sentinel ConsolesFUEL MANAGEMENT SYSTEMSFull-Feature Compliance ConsolesThe TS-1001/TS-2001 consoles feature business management and environmentalcompliance capabilities. They feature inventory, leak detection, reporting andalarm notification.FeaturesCan monitor up to eight tanks.Designed on an open architectureplatform that is easily expandable foradditional capabilities.Low cost, compact console handles awide range of applications.Easily programmed throughmultipurpose function keys to meetsite-specific criteria.Internal high-speed fax/data modemcapability allows remote access fromSystem Sentinel .Executes automatic system checkand notifies user if the unit is notfunctioning properly.Performs continuous leak testing, nostation down time required.CapabilitiesINCON automatic tank gauge (ATG) haveprogrammable settings and are capableof monitoring up to eight tanks.Offers a wide range of advancedcommunication options.ApplicationsThe automatic tank gauge has been designed to monitor tank tightness, gather inventoryinformation and assist with multiple environmental compliance issues.Third party approved volumetric leakdetection (Pd 99.9% at 0.2 gph).Can provide dispenser information andautomate reconciliation when usedin conjunction with the DispenserInterface Module.Provides accurate inventory information,including reports that can be used tobetter schedule deliveries.Multipurpose relays which can be usedfor outputs to overfill alarms andexternal audible and visual indicators.Expanded, backlit LCD display with twolines of 40 columns.Supports multiple languages.Supports English and metric units.Generates numerous system warningsand tank alarms to quickly notify theuser of any potential problems.Supports important generator and fuelmanagement features.9

FUEL MANAGEMENT SYSTEMSTank Sentinel ConsolesTS-2001/1001 SpecificationsUNIT MODELDimensionsInput channelsTS-1001TS-1001/GTS-200111” 12” 4”11” 12” 4”17” 12” 6”2 (10*)2 (10*)2 (26*)Output only channels2 (10*)2 (10*)2 (26*)Sensor inputs12 (28*)12 (28*)24 (40*)NoYesNo428Generator back upNumber of tanks monitoredThe following specifications apply to all models:Display type12.0”(30.48 CM)Alphanumeric LCDApplicable liquidsPetroleum, chemicals and hazardous wasteLevel unitsInches or millimetersTemperature unitsDegrees Fahrenheit or CelsiusVolume unitsGallons or litersNumber of LLDs supported8Display size2 lines of 40 charactersPrinter type24 column thermalPower requirements11.0”(27.94 CM)4.0”(10.16 CM)TS-1001115 VAC 15%, -10%, 100 Watts maximum,1 Amp maximum; 230 VAC 15%, -10%,100 Watts maximum, 0.5 Amp maximumOperating temperature32 to 122 F (0 to 50 C)Storage temperature-4 to 140 F (-20 to 60 C)Intrinsic Safety RatingClass I, Div. I, Group D*Maximum number when including additional optionsPART NUMBER12.0”(30.48 CM)DESCRIPTIONTS-1001 (T1)/TS-2001 (T2) 110 VAC MODELST1P/0Leak Monitor (0 tanks): 12 sensor inputs with printerT1P/2ATG: up to 2 tanks and 12 sensor inputs with printerT1P/4ATG: up to 4 tanks and 12 sensor inputs with printerT2P/8ATG: up to 8 tanks and 24 sensor inputs with printerTS-1001 (V1)/TS-2001 (V2) 220 VAC MODELSV1P/0CLeak Monitor (0 tanks): 12 sensor inputs with printerV1P/2CATG: up to 2 tanks and 12 sensor inputs with printerV1P/4CATG: up to 4 tanks and 12 sensor inputs with printerV2P/8CATG: up to 8 tanks and 24 sensor inputs with printer1017.0”(43.18 CM)6.0”(15.24 CM)TS-2001

Tank Sentinel ConsolesFUEL MANAGEMENT SYSTEMSFixed Feature Inventory Control ConsolesThis inventory control family of products offers a feature-rich and cost-effectivesolution for continuous inventory management of fuel sites where in-tank leakdetection is not required.FeaturesCost-effective system can provide upto-the-minute inventory information.State-of-the-art communicationcapability.Feature-rich programming generatesdetailed inventory managementreports.Fully compatible with System Sentinel remote monitoring software.CapabilitiesProvides real-time, accurate inventoryand delivery information for each tankmonitored.Supports up to twenty-four sensors forsumps, interstitial spaces and test wellapplications.Can control remote alarms and pumpsvia multipurpose, high current relays.Self-calibration and diagnostic featuresquickly notify users of potentialproblems.Delivers cost-effective overfillprotection.ApplicationsThe TS-504 and TS-508 family of tank monitors is the perfect solution for monitoring andcontrolling liquid levels in aboveground tanks at:Retail fueling sitesBulk fuel terminalsFuel distribution depotsChemical storage plantsHeating oil storage terminalsMany other inventory control applicationsnot requiring in-tank leak detectionBulk storage locations for othermotor fluidsCan provide sales through putinformation and automatedreconciliation of sales andconsumption data when used with theINCON dispenser interface module.Multiple monitors can be easilynetworked to support large tank farmsand bulk terminals with more thaneight tanks.Can be remotely monitored andcontrolled via System Sentinel remotefuel management software.Supports multiple languages as well asEnglish and metric units.11

FUEL MANAGEMENT SYSTEMSTank Sentinel ConsolesTS-504/508 SpecificationsUNIT MODELTS-504 & 508Dimensions12” 11” 4”Operating temperature32 to 122 F (0 to 50 C)Storage temperature-4 to 140 F (-20 to 60 C)Sensor inputs8 (24*)Form C Relay Output Channels2Liquid Levels Probe Input Channels(Number of tanks monitored)4 (TS-504)8 (TS-508)12.0”(30.48 CM)The following specifications apply to all models:Display typeAlphanumeric LCDApplicable liquidsPetroleum, chemicals and hazardous wasteLevel unitsInches or millimetersTemperature unitsDegrees Fahrenheit or CelsiusVolume unitsGallons or litersDisplay size2 lines of 40 charactersPrinter type24 column thermalPower requirements115 VAC 15%, -10%, 100 Watts maximum,1 Amp maximum; 230 VAC 15%, -10%,100 Watts maximum, 0.5 Amp maximum*Total number including additional options.PART NUMBERDESCRIPTIONTS-504 (T504)/TS-508 (T508) 110 VAC MODELST504/4Monitors up to 4 tanks, 8 sensor inputsT504P/4Monitors up to 4 tanks, 8 sensor inputs with printerT508/8Monitors up to 8 tanks, 8 sensor inputsT508P/8Monitors up to 8 tanks, 8 sensor inputs with printerTS-504 (V504)/TS-508 (V508) 220 VAC MODELSV504/4CMonitors up to 4 tanks, 8 sensor inputsV504P/4CMonitors up to 4 tanks, 8 sensor inputs with printerV508/8CMonitors up to 8 tanks, 8 sensor inputsV508/8CMonitors up to 8 tanks, 8 sensor inputs with printer1211.0”(27.94 CM)4.0”(10.16 CM)TS-504/508

FUEL MANAGEMENT SYSTEMSFixed Feature Back-Up GeneratorTank MonitoringThe TS-1001/G back-up generator tank monitoring system provides fuel inventorycontrol, generator runs status reports and continous leak detection.FeaturesCan monitor two tanks simultaneously.Proven INCON design.Easy, site-specific programmingthrough keyboard.Accurate inventory information, including days supply remaining.Alarms and positive shut-off avaiable.As many as 28 sensor inputs.Communicates directiy to SystemSentinel software.Uses highly accurate magnetostrictiveprobe technology.CapabilitiesGenerates inventory, compliance andfuel management reports.Performs continuous leak detection.Supports English and metric units, andmultiple languages.Generates numerous system warningand tank alarms to quickly notify theuser of any potential problems.4 to 20ma output signal available asan option.Can open and shut appropriate valvesthrough multi-purpose relays.13

FUEL MANAGEMENT SYSTEMSTS-1001/G SpecificationsUNIT MODELTS-10001/GDimensions12” 11” 4”Input channels2 standard, 8 optionalOutput only channelsSensor2 standard, 8 optional12 standard, 16 optionalNumber of tanks monitoredDisplay type2Alphanumeric LCDApplicable liquidsLevel unitsInches or centimetersTemperature unitsVolume unitsDerees Farenheit or CelsiusGallons or litersDisplay size2 lines of 40 charactrersPrinter type24 column thermalPower requirements115 VAC 15%, -10%, 100 Watts maximum, 1Amp maximum; 230 VAC 15%, -10%, (specialorder), 100 Watts maximum, 0.5 Amp maximumPART NUMBERDESCRIPTIONT1P/2GOne to two tank configuration with generator back-up capability (110 VAC)V1P/2GOne to two tank configuration with generator back-up capabiility (220 VAC)1412.0”(304.8 cm)Petroleum, chemicals and hazardous wastes11.0”(279.4 cm)4.0”(101.6 cm)

Tank Sentinel ConsolesFUEL MANAGEMENT SYSTEMSFixed Feature Tank Monitoring andCompliance KitsThe TS-750 kit is a complete, easy to order and cost effective solution for yourenvironmental compliance needs. It provides inventory control and leak detectionfor sites with up to four underground storage tanks.FeaturesDesigned specifically to deliver costeffective environmental compliance.TS-750 compliance tank gaugeincludes printer.Can accommodate up to eight sensorsand four probes.Provides real-time, accurate inventoryand deliver information for each tankmonitored.Optional continuous 24 hour leaktesting (SCALD).Capable of multiple alarm modes.Can control remote visual andaudible alarms.Easily programmed to meet sitespecific criteria.Uses INCON’s magnetostrictivetechnology probes forunparalleled accuracy.Reports product and water levelsin tank.Temperature compensated.Will accommodate tanks up to 12 feetin diameter.Kits provide for easy ordering andgreat value.Ordering InformationTS-LL2 PROBEPROBE INSTALL KITFLOATSThe TS-750 is available in kit form,designed specifically for undergroundfuel storage tank sites. When ordering,specify the number of tanks, thediameter of each tank and the producttype for each tank. INCON will providethe appropriate TS-750 tank gauge,probes, floats and installation kits foreach site.15

FUEL MANAGEMENT SYSTEMSTank Sentinel ConsolesTS-750 SpecificationsUNIT MODELTS-750Dimensions12” 11” 4”Operating temperature32 to 122 F (0 to 50 C)Storage temperature-4 to 140 F (-20 to 60 C)Form C Relay Output Channels2Leak Detection Sensor Input Channel8Liquid Levels Probe Input Channels(No. of tanks monitored)1, 2, 3 or 412.0”(30.48 CM)The following specifications apply to all models:Display typeAlphanumeric LCDApplicable liquidsPetroleumLevel unitsInches or millimetersNumber of tanks monitored1, 2, 3 or 4Volume unitsGallons or litersDisplay size2 lines of 40 charactersPrinter type24 column thermalPower requirements115 VAC 15%, -10%, 100 Watts maximum,1 Amp maximum; 230 VAC 15%, -10%,100 Watts maximum, 0.5 Amp maximumThe TS-750 kit consists of the TS-750 compliance monitor, probe(s), float(s) andinstallation kit. Please specify the diameter of each tank and the product stored ineach tank when ordering. The following kits are currently available.PART NUMBERDESCRIPTIONTS-750 (T750) 110 VAC MODELST750P/1Single tank kit, eight sensor inputs with printerT750P/1SSingle tank kit, eight sensor inputs with printer and SCALDT750P/2Two (2) tank kit, eight sensor inputs with printerT750P/2STwo (2) tank kit, eight sensor inputs with printer and SCALDT750P/3Three (3) tank kit, eight sensor inputs with printerT750P/3SThree (3) tank kit, eight sensor inputs with printer and SCALDT750P/4Four (4) tank kit, eight sensor inputs with printerT750P/4SFour (4) tank kit, eight sensor inputs with printer and SCALDTS-750 (V750)/TS-508 (V508) 220 VAC MODELSV750P/1CSingle tank kit, eight sensor inputs w

Tank Sentinel - Automatic Tank Gauge TS-5 The INCON automatic tank gauge provides inventory and leak detection for up to twelve storage tanks. Applications The automatic tank gauge has been designed to monitor tank tightness and gather inventory information. Third party

Related Documents:

This catalog shows Olympus standard phased array probes, which are divided into three types: angle beam probes, integrated wedge probes, and immersion probes. Other types of probes can be designed to suit the needs of your application.File Size: 1MB

3- Differential surge tank: an orifice tank having a riser is called differential tank. 4- One- way surge tank: in a one way surge tank the liquid flows from the tank into the pipeline only when the pressure in the pipeline drops below the liquid level in the surge tank. 5- Closed surge tank: if the top of the tank is closed and there is

Eddy Current Probes Olympus eddy current probes consist of the acquired brands of Nortec and NDT Engineering. We offer more than 10,000 stan-dard and custom designed eddy current probes, standard refer-ences, and accessories. This catalog features many of the standard design probes

impedance standard substrates (ISSs) from Cascade Microtech. Figure 9 shows the probes in the alignment setup on the ISS for the 106-683A substrate for short, open and load for GS and SG probes. Figure 9 - Cascade probes probing ISS for calibration Before performing the calibration measurements, the probes are aligned using alignment marks on the

We offer a wide selection of eddy current and other electromagnetic probes. Bobbin probes for non-ferromagnetic tube inspections X-Probe and CXB multi-coil array probes to quickly detect and characterize all flaws, including circumferential cracks Rotating (MRPC) probes to detect and characterize all flaws at

If upgrading the functionality of dispatch consoles is your priority, start by replacing some or all of your existing circuit-switched consoles. Begin by: Deploying an ASTRO 25 core system Deploying one or more Motorola MCC 7500 and/or MCC 7100 Consoles Integrating the new consoles into your existing network infrastructure

Other examples of sensors Heart monitoring sensors "Managing Care Through the Air" » IEEE Spectrum Dec 2004 Rain sensors for wiper control High-end autos Pressure sensors Touch pads/screens Proximity sensors Collision avoidance Vibration sensors Smoke sensors Based on the diffraction of light waves

Loughborough College Local Offer Des Gentleman Learner Services Manager des.gentleman@loucoll.ac.uk . 2 Regulation 3 Special Educational Needs and Disability (Information) Regulations (2014) School/College Name: Loughborough College Address: Radmoor Road, Loughborough, Leicestershire Telephone Number: 01509 618375 Principal and CEO: Jo Maher Executive Lead Learner Services: Heather Clarke .