GeneralSpecificationsModel YPC4000Portable Modular Calibrator with HART Communications YPC4000 is a combination Calibrator / HART Communicatorthat reduces the time spent on field calibrations and the numberof instruments that have to be carried into the field. TheYPC4000 Series delivers the versatility of a modular calibrator and the convenience of HART communications in one handheldunit. Users can view up to four measurements simultaneously on the high resolution LCD or compare HART PV and AO values tocorresponding values measured. Available sensor modulesinclude a variety of differential, gauge, vacuum and absolutepressure (for EJA/EJX) as well as temperature (for YTA. A voltage and current meter is integral to the base unit. All HARTfield devices can be configured, polled, and trimmed using HART communications. Device Specific commands forsupported devices are included.FEATURES & ADVANTAGESUSER INTERFACE – 2.6” x 2.6” display, four soft keys (definitionschange with mode requirements) and eight hard keys provide userinterface. Display is configurable for 1 to 4 simultaneousmeasurements.MODULES – select from a variety of positive lock measurementmodules for excellent versatility.FIELD RECERTIFICATION – sensor modules and integral V / I canbe recalibrated for zero, span, & linearity through the base unit.MEASUREMENT UNITS – customary English and Metric Systemunits are selectableUSER CONVENIENCE – Auto shut off, Damping, Min/Max valuecapture, display Hold, sensor Zero, direct Contrast adjustment &tare.SECURITY LOCKOUT – YPC4000 settings can be locked outentirely or by specific feature.DIAGNOSTICS – YPC4000 self-tests upon power up and uponinstallation of sensor modules. Advisories are posted on thedisplay.FIELD UPDATES – uses Internet downloads to update and add capability / HART support DEDICATED DOF MEMORY – Memory for 500 HART profiles.ALL-IN-ONE TOOL – takes the place of multiple handheldinstruments, simplifies workload and improves productivityDOCUMENTING – Documenting memory and firmware for use with DMS software. Stores up to 200 HART configuration filesand over 100 calibration results (as-found & as-left data [up to 21points each], time/date info, tag). Communicate with PC via DB-9connector.INTRINSIC SAFETY – Class I, Div I areas per CSA 22.2 & UL913 by MET Laboratories .OPTIONAL DMS SOFTWARE – The Device ManagementSystem software is a full feature software tool for calibration andconfiguration management of smart and conventional fielddevices. DMS provides user-friendly navigation and organizationof field devices, scheduling of calibration procedures, andstorage of smart field device configuration data.The calibration management features are extended to theCalibration / Configuration equipment as well. Calibrationand configuration change reporting, certificates, anddevice history are standard features in DMS.SPECIFICATIONSBASE UNIT: 9.00"L x 4.70"W x 3.58"D ABS plastic case withshock absorbing boot, 28 ozs, three bays for measurementmodulesDISPLAY: 128 x 128 pixel graphic display, 2.6” x 2.6”viewable area, 5-digit resolutionPOWER: 6 AA alkaline or NiMH batteries; optional 100– 240 Vac power adapterTEMPERATURE RANGE: Storage:-40 F to 140 F (-40 C to60 C) Operating: 23 F to 122 F (-5 C to 50 C)CONNECTIONS: Pressure: 1/8” FNPT, 316ss Electrical:Std. banana jacks (¾” center) for 50 mA/Volts, HART &Loop leads Data transfer: DB-9 for RS-232CNIST TRACEABLE ACCURACY:Pressure: 0.025% to 0.10% of F.S including all effects oflinearity, repeatability, hysteresis and temperature over therange 23 F to 122 F.Current / Voltage: 0.025% of F.S. 0.001%of Span per F (ref. temp. 70 F).PRESSURE MODULE LIMITS / MEDIAS: GI / AI modules:2X range / 316ss compatible DN modules: 2X range whenpressurized on high side only, 150 PSI when appliedsimultaneously to high and low sides / dry gases onlyMODULES: 2.3”L x 1.3”W x 2.6”D, 8.3 ozs or less. Positivelock with

YPC 4010 HART Communicator / Calibrator - Base calibrator unit with HART capability (includes HART leads, and 250 ohm resistor) - see available sensor modules on next page ; use VMA0055 for 24Vdc loop supply Code Reserved -01 Yokogawa

Related Documents:

HART Communication Foundation Yokogawa Contact Information For customer Assistance Address Yokogawa Corporation of America 2 Dart Road Newnan, GA. 30265USA Telephone 1-800-888-6400 E-mail meters-instr@us.yokogawa.com . YHC5150X Series HART Communicator Overview

Yokogawa Corporation of America 2 Dart Road, Newnan, GA 30265 770-254-0400 IM 61A-E-A 2nd Edition: Dec. 2004 Users Manual YPC 4000 C

TTL and CMOS logic 74 Series 74ls00 datasheet, 74ls02 datasheet, 74ls04 datasheet, 74ls08 datasheet, 74ls11 datasheet, 7414 datasheet, 74ls14 datasheet, 74ls20 datasheet, 74ls30 datasheet, 74ls32

YOKOGAWA Yokogawa Corporation of America 2 Dart Road Newnan, GA 30265 To: Classis Controls From: Todd Garber, Yokogawa Corporation of America Date: December I, 2003 Subject: Classic Control’ s Yokogawa Territory Coverage This memo is to serve as verifica

and features of the Yokogawa Zirconia Oxygen Analyzers: Compact design for flexible low-cost installation Long-life sensor Reduced maintenance and calibration using self-diagnostics Excellent price/ performance correlation Yokogawa’s Zirconia Oxygen analyzer can also be use

Yokogawa released the first Sushi Sensor, a wireless vibration sensor, in March 2018. In July 2019, Yokogawa released wireless temperature and pressure sensors, expanding the sensor portfolio (Note 1: The wireless vibration sensor has been released in Japan and some other countries. Although the wireless pressure and temperature sensors are .

Mar 14, 2021 · Datasheet Fortigate-60D CP0 FortiSOC2 1 1839 3879 n/a Fortigate 60D datasheet FortiWiFi-60E SOC3 ARMv7 4 1863 3662 (EMMC) n/a Fortigate 60E datasheet Fortigate-60E SOC3 ARMv7 4 1866 3662 (EMMC) n/a Fortigate 60E datasheet FortiGate-61E SOC3 ARMv7 4 1866 3662 (EMMC) 122104 Fortigate

Austin, Oscar Palmer Nacogdoches, TX Vietnam War Austin, William . Lopez, Jose Mendoze Mission, TX (Santiago Huitlan, Mexico) World War II (Most sources say that Lopez was born in Texas but he later stated in multiple interviews and his funeral program recorded that he was born in Mexico) Lummus, Jack Ennis, TX World War II Martinez, Benito Fort Hancock, TX Korean War . Compiled by Gayle .