FMU Δp-Indicators and Pressure IndicatorsIndicators SeriesMAX 420 barFilter indicators167

FMU Δp-IndicatorsIndicators SeriesFeatures & BenefitsFeaturesAdvantagesBenefitsIndicators fatigue tested to fullpressure ratingReliable indicators for heavy duty applicationsReliable and continuous control of thefilter in all applicationsCartridge screw-in type indicatorsEasy mountingReliable sealing, no leakageVisual, electrical and electronicindicators availableCheck element condition at a glanceRight style for the applicationOptimises element life, prevents bypassingMatch your system’s electrical connectionsSeveral indication settingsOptimized for each bypass settingRight indicator for applicationVisual indicatorsLocal monitoring of the element conditionReliable low cost indicatorElectrical indicator withchange-over switchOption of Normally Open (N.0.) and NormallyClosed (N.C.) functionApproved for low voltage and highvoltage use including machine controlsystems and PLC’sElectrical indicator with 4 LEDsThermal lock-outVisual early warning with yellow LEDPre-alarm with yellow LED and wired outputAlarm with red LED and wired outputNo false alarm because of lowtemperature oilAllows time to schedule element changeIndicates upcoming element changeClear indication for element changeRight indicators for special applicationsImproved machine surveillanceProgrammable and ATEX certifiedindicators availableTypical ApplicationsIndustrial equipmentMobile equipmentMarine/offshore applicationsThe Parker FMU SeriesDifferential Pressure IndicatorsThe FMU range of filter condition indicators, aredesigned for use on a wide range of Parker filtersand suitable for competitive interchange (consultParker Filtration for details).Ideal for giving accurate visual, electronic or electricalfeedback of filter element condition, in order tofacilitate effective maintenance and ensuringhydraulic systems, marine/mobile or industrial areprotected from particulate contamination.168Parker HannifinFilter Division EuropeFDHB200UK. Section 23

SpecificationThe differential pressure values ofstandard indicator models:1.2 bar 0.11.5 bar 0.22.5 bar 0.25.0 bar 0.47.0 bar 0.58.5 bar 0.5(Indicators for other differential pressure values are optional).Maximum operating pressure:420 bar (250 bar for aluminium).Maximum differential pressure:210 bar.Working temperature range:-20 C to 85 C.Material of housing:Brass, aluminium or stainless steel.Seals:Fluoroelastomer, Nitrile or EPDM.FMU Δp – Indicators are typically used with the following filters:Marine filters: 2020, 2035, 2040, 2045, 2060, 2065, 2070, 2110 and 2520.Types: 2035, 2040, 2045 and 2060 require FMU-Block for connecting indicator to the filter.U12H1.5 barMedium pressure filters series: 45M and 130M.High pressure filters series: 70L, 70T, 70B, 5000, 7100 and 7200.U12H2.5 barHigh pressure filters without bypass valve: 70L, 70T, 70B, 7100 and 7200.U12H7.0 barMedium and low pressure filter series;Note for PD Range only 2.5 bar indicators are available15CN, 40CN, 80CN, 22PD, 32PD, 15P, 30P, 40RF, 50RF, IL8, 12M, 22M, 16P, 26P, 36PU14M1.2 and 2.5 barHigh pressure filters 18P, 28P, 38P, FDA, FDBU14H2.5 and 5.0 barFilter indicators169

FMU Δp-IndicatorsIndicators SeriesFMUT ElectricalU12H modelContact configuration U12H modelP1-P2Rotating part 360 partNormally closed (N.C)31Enclosure classElectrical connectorOvervoltage categoryACDU14M modelU14H10532Ø18.83 0.067/8-14UNF-2AU14H modelIP65DIN 43650II (EN61010-1)BContact configuration U14M & U14HP2 low pressureP1-P2C13P1 high Non-inductive load (A)Inductive load loadloadloadN.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O.1.5 0.72.5 1.3531.0 0.51.5 0.83253542201053442max. ltageNormally open (N.O)COMNormally closed (N.C)NoconnectPinU14M10532Ø19.78 0.067/8-14UNF-2ABIndication (N.O)COMP1 high pressureP2 low pressure2DFixedNoconnectPinU12H9827.5Ø16.2 0.053/4-16UNF-2AABCFMUM3 Visual Auto Reset/FMUM1 Visual Manual ResetOperationU12H modelR-type pushhere for resetø24OperationRed colourvisible whenindicator onU14M modelU14H modelNote: Only FPUM3visual auto reset availablefor models U14M andU14H. FMUM1 notavailable.Low pressure27.5High pressure55.53260Red colourvisible whenindicator onHigh pressureø19.78 -0.06Low pressure/ -16 UNF-2A3 4/ - 14UNF - 2A7 8170ø18.83 -0.06/ - 14UNF - 2A7 8Parker HannifinFilter Division EuropeFDHB200UK. Section 23

FMUF ElectronicU12H modelContact configurationNPN V3 10.36 VdcLoad1Normallyopen2(N.O)ABCRotating part 360 Loadpart0VGreen LEDmax 300 mAYellow LED’sDA4FixedFMU FNPNRed LEDPNPNormallyopen(N.O)U14M10532Ø19.78 0.067/8-14UNF-2AU14H10532Ø18.83 0.067/8-14UNF-2A V1Load2Load 10.36 Vdc0V4max 300 mAHigh pressureB3FMU FPNPU12H9827.5Ø16.2 0.053/4-16UNF-2ACDLow pressureU14M modelU14H modelThermal lock-out (standard setting 20 C)Indicator operates only when temperature is above setting.Green LED is blinking if temperature is lower. (not in U12H)LED statusG Y1 Y2 ROutputBInd. press.setting50%–75%2 active100%1 activeEnclosure classElectrical connectorInput supply voltage*Indication outputOutput type:Low pressureIP65DIN 43650, cable connection PG9 or optinally M12 4-pin 10 to 36 Vdcmax. 300 mA/36 VdcN.O. or N.C./NPN or PNPCDNote: Do not connect output terminals 1 or 2 directly (without load) to powersupply terminals, because this will damage the equipment.High pressureCDSafety feature: The 250 bar U14M indicator does not fit into the U14H cavity,which is used in 420 bar filtersFPUL1 ProgrammableProgrammable Δp-indicatorDimensions: see FMUF electronic Δp-indicatorAll settings adjustable (settings made via PC) Connections cable and softwareavailable from Parker 4 LEDs giving visual indication: Green (G): Power ON Yellow 1 (Y1): Pre-alarm 1 (presetting 50%) Yellow 2 (Y2): Pre-alarm 2 (presetting 75%) Red (R): Indication (presetting 100%) two independently programmable indication outputs can be set independently from each other and LED setting output type: NPN or PNP switching type: N.O. or N.C. setting range: 0,5 . 10 bar thermal lock-out range: 0 . 100 C includes a microchip with memory logs number of alarms: max 65535 time indication on (output 1): max 1092 hours time power on (running hours): max 7 1/2 years upload and reset via PCFilter indicators171

FMU Δp-IndicatorsIndicators SeriesOrdering InformationProduct configuratorBox 1Box 2M3FMUBox 3KBox 4VBox 5MBox 6U14Box 7HBox 8Box 1CodeIndicator seriesFilter monitoring unitCodeFMUBox 2Box 3Indicator settingFilter typeDifferential pressure indicatorVisual manual resetVisual autoresetElectricalElectronic 4 LED, PNP, N.O.Electronic 4 LED, NPN, N.O.Electronic 4 LED, PNP, N.C.Electronic 4 LED, NPN, N.C.Programmable with memory logsEx versionCodeM1*M3T1F1F2F3F4L1X1* available only with U12 threadBox 4Indicator setting1.0 bar (14 psi)1.2 bar (17 psi)1.5 bar (21 psi)2.5 bar (35 psi)5.0 bar (70 psi)7.0 bar (98 psi)8.5 bar (125 psi)Standardcaca, b, cbcCodeFGHKMNPStandard settings:a: U14M, former -W3b: U14H, former -W6C: U12H, former -F6Box 5Box 6Seal typeSeal materialNitrileFluoroelastomerEPDMNeoprenIndicator bodyCodeBVENThread connectionIndicator bodyAluminium (Box 7, code M)Brass (Box 7, code H)Stainless steelBox 7CodeAMRThread connection3/4" - 16UNF-2A7/8" - 14UNF-2ACodeU12U14Box 8Max PressureMax pressureMedium pressure housings ( 250 bar)High pressure housings ( 420 bar)OptionsCodeMHOptionsStandardOther optionsCodeomitfactory suppliedNote: F and L type indicators. Non-standard thermallockout settings shown here.Indicator type X1: ATEX Δp-indicatorElectronic indicator accordant with ATEX 94/9/EC directive: (Ex) II 2 GD Eex mII T6.Degree of protection IP66. For details contact Parker Filtration.Connection cable software for programmable indicator L1Connection cable for PC serial connection and software for indicator settings and utilising memory logs.Ordering Code: 905075030Seal kits (fluroelastomer)Indicators with thread connection U12H (former -F6)Indicators with thread connection U14M (former -W3)Indicators with thread connection U14H (former -W6)Ordering code911045078911045086911045087Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.172Parker HannifinFilter Division EuropeFDHB200UK. Section 23

Pressure Indicators for Low Pressure FiltersETF FilterVisual pressure indicator48 Vdc electrical indicator 1.2 bar250 VAC electrical indicator 1.2 barCode G2Code S2/S3Code S4mm (inches)mm (inches)mm (inches)31Rotatingpart 360 (1.22)G1/838(1.49)40(1.57)67(2.64)HEX 2456(2.20)44 (1.73)30 (1.18) x30 (1.18)C374(2.91)2 NO1 NC32(1.26)10(0.39)10 (0.39)G1/8KFixed partHEX 27(1.06)OptionDescriptionG2Visual indicator1.2 barConnection/VoltageN/AG1/8KWiringPart numberN/AFMUG2FBMG02LNormally open contactsS2/S3S4Electrical indicator1.2 bar42 VdcmaxElectrical indicator1.2 bar250 VacmaxSelect either normally open (NO)or normally closed (NC)Indicator PS pressure switch1NC2NO3CFMUS2FBMG02LorFMUS3FBMG02LNormally closed contactsFMUS4FBMG02LIndicator PS NO/NC pressure switchProtective coverProtective capwith dual cable ductfor 1, 7-2, 3mm diameter cableNormally open contacts24Amp 6.3x8terminals58551 COM.2 N.C.3 N.O.24 A/F9927 A/FNormally closed contacts74751SwitchG1/8 ad connectionElec.connectionProtectionCodeVisual indicatorM10: codeG1/8: code42V / 4AM10x1AMP 6.3x0.8 terminals protective capIP65 (with cap) terminals IP00FMUS1EBMM10L (Switch)1.2 ratingThread connectionElec.connectionProtectionSwitch typeCode42V / 2AG1/8 - M10x1AMP terminal 6.3x0.8IP65 (terminal IP00)NO or NCFMUS2EBMG02L (NO switch)FMUS3EBMG02L (NC switch)Visual indicatorM10: codeG1/8: code1.2 barFMUG1EBPM10LFMUG2EBPG02LFilter indicators173

Notes174Parker HannifinFilter Division EuropeFDHB200UK.

The Parker FMU Series Differential Pressure Indicators The FMU range of filter condition indicators, are designed for use on a wide range of Parker filters and suitable for competitive interchange (consult Parker Filtration for details). Ideal for giving accurate visual, electronic or ele

Related Documents:

Earth Pressure (P) 8 Earth pressure is the pressure exerted by the retaining material on the retaining wall. This pressure tends to deflect the wall outward. Types of earth pressure: Active earth pressure or earth pressure (Pa) and Passive earth pressure (P p). Active earth pressure tends to deflect the wall away from the backfill.File Size: 1MBPage Count: 55

Supply port for pressure to be regulated VOLUME CONTROLLER For fine adjustment of pressure OUTPUT PORTS For regulated pressure output . PCS-01 Pressure Controlling System. PGS-01 Pressure Generating System 0-2000 PSI PRESSURE REGULATOR For pressure control to target pressure FILL PORT Input port for filling internal single cylinder INTERNAL .

Pressure support Pressure control ventilation Pressure-controlled inverse-ratio ventilation Airway pressure release ventilation Volume-assured pressure modes (1-5 below) 1. Pressure augmentation (Bear 1000) 2. Volume Support (Siemens) 3. Pressure Regulated Control (Siemens) Main Parameters Pressure support level, sensitivity, FIO 2, and PEEP

Acceptance Factor is calculated using the pressure tank precharge pressure (2 psig below the pump cut-in pressure). The pressure tank will oper ate between the pressures set by the pressure switch. The tank precharge pressure should be set at 2 psig below the low pressure cut -in to prevent a noticeable drop in pressure at the fixture.

Bosch Rexroth AG, RE 92650/06.2016 6 A1VO Series 10 Axial piston variable pump Working pressure range Working pressure range Pressure at service line port B Definition Nominal pressure p nom 250 bar The nominal pressure corresponds to the maximum design pressure. Maximum pressure p max 280 bar The maximum pressure corresponds the maximum working pressure within the

Table of contents 004 –007 Faulted circuit indicators overview 008 –010 Overhead faulted circuit indicators 011 –022 Underground faulted circuit indicators 023 –027 Cellular RTUs and receivers 028 –033 Clamp-type faulted circuit indicators 034 –043 Test point indicators 044 –047 Current sensors 048 –072 Capacitor controls 073 Index —

Indicators of Smart Growth in Maryland NCSGRE January 2011 5 . Conceptual and Technical Issues Common to any indicator effort: - Number of possible indicators. - Measurement of indicators. - Interpretation of indicators. - Aggregation of indicators.

APPLIED ENGLISH GRAMMAR AND COMPOSITION [For Classes IX & X] English (Communicative) & English (Language and Literature) By Dr Madan Mohan Sharma M.A., Ph.D. Former Head, Department of English University College, Rohtak New Saraswati House (India) Pvt. Ltd. Second Floor, MGM Tower, 19 Ansari Road, Daryaganj, New Delhi-110002 (India) Ph: 91-11-43556600 Fax: 91-11-43556688 E-mail: delhi .