LEAK DETECTORS AND LEAK MONITORS - Yellow Jacket

2y ago
11 Views
2 Downloads
882.03 KB
8 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Audrey Hope
Transcription

80SYSTEM TOOLSHEATINGINSTRUMENTSLEAK DETECTORSAND MONITORSWIRELESS ANDELECTRONICINSTRUMENTSHOSE ADAPTERS,VALVES & PARTSVACUUM ANDCHARGING HOSESVACUUM AK DETECTORS AND LEAK MONITORS

CHARGINGSYSTEMSGAUGESRECOVERYMACHINESVACUUM PUMPSYSTEMSVACUUM ANDCHARGING HOSESHOSE ADAPTERS,VALVES & PARTSWIRELESS ANDELECTRONICINSTRUMENTSHEATINGINSTRUMENTSThe only tool you will need for fast, easy and certain leak detection.LEAK DETECTORSAND MONITORSAccuProbe Leak DetectorsSYSTEM TOOLS81

HEATINGINSTRUMENTSLEAK DETECTORSAND MONITORSWIRELESS ANDELECTRONICINSTRUMENTSHOSE ADAPTERS,VALVES & PARTSVACUUM ANDCHARGING HOSESVACUUM LLOW JACKET HVAC/RAccuProbe IR LEAK DETECTORUse the infrared (IR) sensor for ultimate sensitivity,accuracy and reliability. Identifying the smallest leaksis fast and easy. Detects all CFC, HCFC, HFC and HFOrefrigerants, including R-134A, R-404A, R-410A andR-1234YF. The Smart Alarm LED shows the size of theleak on a rising scale. Coupled with two modes forsensitivity gives the AccuProbe IR the ability to locate aleak of any size. Sensor Type: Infrared Senses All CFC, HCFC, HFC and HFO Refrigerants Sensitivity Modes: High and Low (Auto Zero) Manual zero capability Audible and Visual Leak Indication Regulations: CE, EN14624, EN61010, SAE2913 Rechargeable Li-Ion Battery Sensitivity will not degrade over timeSpecifications Minimum Sensitivity: 0.1 oz/ yr. (3 g/yr.) Body Material: ABS Body Length: 8.25" (210 mm) Probe Length: 17” (430 mm) Weight: 0.84 lb. (0.38 kg) Calibration: Automatic Response Time: Instantaneous Battery Life: 8 hours Fast Charge Time: 3 hours Holds Charge When Not In Use: 9 months (app.) Operating Temperature Range:-4 F to 140 F (-20 C to 60 C)SYSTEM TOOLS USB micro charging port (cable included)82 Includes one (1) spare filterUPC#Description Includes carrying case69320 Two year over-the-counter warrantyAccessories and Parts Made in the USA69321AccuProbe IR Leak DetectorReplacement Filters (5 pack)

Use the solid electrolyte sensor or UV technology (or both at the same time) to detect the more current anddifficult HFC refrigerants such as R-134a, R-404A, R-407 and R-410A, in addition to all HCFC (R-22) refrigerantsincluding SNAP approved hydrocarbon and HFO refrigerants, all with minimal chance of false alarms.Our solid electrolyte sensor technology reduces heat andgives the sensor longer life than traditional heated anode orheated diode detectors.The Smart Alarm LED shows how big or small a leak is ona scale of one to nine: 1 to 3 – less than 0.1 oz./yr. Instantaneous response time C lears in 12 seconds or less after exposure to a1.75 oz (50g)/yr. leak Automatic calibration and reset to ambient Low battery indicator 4 to 6 – 0.1 to 0.5 oz./yr. Microcontroller technologyIn addition to the Smart Alarm indicator, the AccuProbe UVfeatures low, normal and high sensitivity levels with visualand audible signals. H igh sensitivity will detect even low levels that could bemissed with other detection systems U se low sensitivity as you move the tip over more definedareas of a systemSensitivity:HFC (R-134a) 0.06 oz. (1.7g)/yr.HCFC (R-22) 0.03 oz. (0.9 g)/yr.HFO (1234yf) 0.15 oz. (4.3 g)/yr.Heated solid electrolyte sensor:Over 300 hours service lifewith minimal cleaning andno adjustmentsMaintenance required: NoneBody length: 10.5" (270 mm)Probe length: 17" (430 mm)Weight: 17 oz. (480 g)Warm up time: 20 seconds or lessCalibration: AutomaticResponse time: InstantaneousPower: 4 AA alkaline batteries,4.5 hours continuous lifeOperating temperature range:24 to 125 F (-4 to 52 C)Storage temperature range:-4 to 122 F (-20 to 50 C)Humidity: 0 to 95% RHnon-condensingApprovals: SAE J2913CE marked, EN 14624UPC#Description693366933769338AccuProbe UVAccuProbe UV with global power supply (US, EU, UK, AU, NZ)AccuProbe UV - JapanAccessories and Parts69375693836938469385693866938769388A/C Adapter - global power supply (US, EU, UK, AU, NZ)CE and GS approvedKit – sensor, filters and bottleReplacement sensor and filterSensor filters (5 pak)Leak sensor bottleCarrying case with insertsBattery cover/screw (AccuProbe UV)LEAK DETECTORSAND MONITORSSpecificationsSensitivity:HFC (R-134a) 0.06 oz. (1.7 g)/yr.HCFC (R-22) 0.03 oz. (0.9 g)/yr.HFO (1234yf) 0.15 oz. (4.3 g)/yr.Sensor life: Over 300 hours servicelife with minimal cleaning andno adjustmentsProbe length: 17" Weight: 15 oz.Warm up time: 20 seconds or lessPower: 4 AA alkaline batteries,4.5 hours continuous lifeApprovals: SAE J2913CE marked, EN 1AccuProbe II leak detectorKit – sensor, filter and bottleReplacement sensor and filterSensor filters (5 pak)Leak sensor bottleCarrying case with insertsZipper pouchSYSTEM TOOLSUPC#HEATINGINSTRUMENTSLow, normal andhigh sensitivitylevels with audiblesignals to quicklyand easily pinpointleaks.SpecificationsWIRELESS ANDELECTRONICINSTRUMENTSAccuProbe II LEAK DETECTOR Made in the USAHOSE ADAPTERS,VALVES & PARTSThe frequencyof flashing fromthe electrolytesensor tipincreases asyou get closerto a leak andrefrigerantconcentrationincreases. Theaudible alert, which can also be muted, increases infrequency and duration as concentration increases. 24-month limited warrantyVACUUM ANDCHARGING HOSES I f there is no response from the flashing tip or beepingsignal at the preset normal sensitivityin the general area of a suspected leak, selecthigh sensitivity SAE J2913 certified, CE marked, EN 14624VACUUM PUMPSYSTEMS 7 to 9 – more than 0.5 oz./yr.69354 Long life, stable sensorRECOVERYMACHINES3 UV lights fluoresce between 395 and 415 nanometers. R obust, ergonomic design is easy to use in close areasand extendable into hard-to-reach areasGAUGESAccuProbe UV LEAK DETECTORCHARGINGSYSTEMSEDITION 70 CATALOG83

RECOVERYMACHINESGAUGESCHARGINGSYSTEMSYELLOW JACKET HVAC/RTips for Detecting SystemLeaks with Leak Detector:VACUUM PUMPSYSTEMSVACUUM ANDCHARGING HOSESHOSE ADAPTERS,VALVES & PARTSDetects 5% H2 in 95% Nitrogen Tracer Gas1. I nspect entire A/C system for signs of oil leakage,corrosion cracks or other damage. Follow thesystem in a continuous path so no potential leaksare missed.2. M ake sure there is enough refrigerant in thesystem (about 15% of system capacity or50 psi min.) to generate pressure to detect leaks.3. C heck all service access port fittings. Check sealsin caps.4. M ove detector probe at 1" per second within1/4" of suspected leak area.5. R efrigerant is heavier than air so position probebelow test point.6. M inimize air movement in area to make it easier topinpoint the leak.Many countries are now adopting laws that ban the use of refrigerantsfor system testing. The YELLOW JACKET H2 was developed for theH2 (95% nitrogen and 5% hydrogen) tracer gas mixture.When used with the H2/nitrogen tracer gas mixture, the YELLOWJACKET H2 will detect leak rates less than 5 ppm. Long life, stable sensor Low battery indicator7. V erify an apparent leak by blowing air intosuspected leak to clean the area and see if theleak remains. Does not require rechargeablebatteries CE Certified8. W hen checking for evaporator leaks, check forgas in condensate drain tube. Automatic calibration and resetto ambient True mechanical pump Two-year warranty Made in the USA Three adjustable sensitivity levelsSpecificationsELECTROLYTE SENSORElectrolyte Sensor Leak DetectorsWhen the electrolyte sensing element is exposed to refrigerant,an electrochemical reaction changes the electrical resistancewithin the element, causing an alarm. The sensor is refrigerantspecific with superior sensitivity to all HFCs and HCFCs, andminimal chance of false alarms. When exposed to large amountsof refrigerant, which could poison other systems, the electrolytesensor clears quickly and does not need recalibration beforereuse.LEAK DETECTORSAND MONITORSWIRELESS ANDELECTRONICINSTRUMENTSH2 DETECTORSensitivity: Less than 5 ppmSensor life: Over 300 hoursResponse Time: InstantaneousProbe length: 17" Weight: 1.5 lbs.UPC#693416934269343Warm up time: 20 seconds or lessPower: 4 AA alkaline batteries,8 hours continuous lifeApprovals: EN35422 and EN14624DescriptionH2 leak detectorReplacement sensorCarrying case with inserts (grey)MICRO LED UV LEAK DETECTION KITSAND LAMPS For all A/C systems and lampsIndividual reflectors surround eachof five LEDs recessed for protectionin the stainless steel head. Long life LEDs Constant ON switchSYSTEM TOOLSHEATINGINSTRUMENTS Sealing locks out moisture69782 AA Alkaline battery included(dispose of batteries via disposalpractices in your area) Aluminum bodyUPC# DescriptionHEATED SENSOR6978269788*69789*6979369794395-415 nm wavelength UV LED flashlightMicro UV LED and dye kit for autoMicro UV LED and dye kit for AC/RReplacement pouch for LED (for older style with black casing)Lithium battery (2 pak) (for older style with black casing)*N ot for direct injection into R-410A systems due to high pressure.Bulbs not replaceable.84

LARGE SYSTEM INJECTORSSystems with up to 32 gallons of lubricantDYE AND OIL INJECTORS Recommended forR-410A Add oil to system Put oil in after changeout Made in the USA Refrigerant sampling Recommended for R-410AUPC#DescriptionLarge system injectorLarge system injector with couplerThis 2 oz. injector is easy to refill and easy to operate.Calibrations are clearly marked on the injector. Connectto A/C lo-side and rotate handle. AC/R and auto models.MADE INMaximum port pressure of 250 psi.69730THE USADescription697296973069731Universal screw injector (no hose)1/4" Calibrated A/C screw injector (with hose)Auto R-134a calibrated A/C screw injectorwith service couplerAuto R-134a calibrated A/C screw injectorwithout service coupler1/4" replacement hoseR-134a replacement hose697326972369724UNIVERSAL A/CDISPOSABLE INJECTORSUniversal disposable 1 oz. applicator for fast economical dispensing.Universal dye for all common refrigerants and oils. Two 1/2 oz.applications for regular split systems or four 1/4 oz. applications forsmall appliances or auto A/C. One dye minimizes inventoryUNIVERSAL A/C DYEINJECTORS AND HOSE No back-up refrigerant to movedye into system Maximum system port pressureof 80 psi Not for direct injection intoR-410A systems due to highpressure M aximum system port pressure of 80 psi Made in the USA N ot for direct injection into R-410A systems dueto high pressure M ade in the USAUPC#US Patent # 6,164,348Description69702Hose plus 2 injectors for AC/R69703Auto R-134a hose, coupling and injectors69705Injector hose with SealRight69706 Auto R-134a injector hose and service couplerUPC#Easy to use: connect to system, push inplunger, then disconnectDescription69700 1 oz. (30 ml) Injector (6 pak) (12 residential applications/case)69721 1 oz. (30 ml) Injector (2 pak) (4 residential applications/package)697271 oz. (30 ml) InjectorSYSTEM TOOLSUS Patent # 6,164,348HEATINGINSTRUMENTSUniversal A/C dye injectors work in AC/R and autoA/C systems. Four 1/4 oz. applications of dye ineach disposable tube make it economical, fastand clean. Hose features back flow check valve.LEAK DETECTORSAND MONITORS Less costly and faster than manyother methodsWIRELESS ANDELECTRONICINSTRUMENTSUPC#Description1/4 oz. Oil injector1/2 oz. Oil injector2 oz. Oil injector4 oz. Oil injector“O” ring 1/4 and 1/2 oz. injector (5 pak)“O” ring 2 and 4 oz. injector (5 pak)Replacement hoseHOSE ADAPTERS,VALVES & PARTSCALIBRATED A/C SCREW CUUM ANDCHARGING HOSES Made in the USAVACUUM PUMPSYSTEMS Add scanner fluorescentsolution Add additives to system6955577950RECOVERYMACHINESSaves time on manyapplications:GAUGESBody and cap are ruggedaluminum with an “O” ringseal. 1/4" Male fitting at oneend with Schrader. A ballvalve for control on otherend with a short length ofhose. Valve depressor in1/4" Female end. 600 psiworking pressure.Self-contained injectionsystem for inducing upto 16 oz. of universalAC/R dye into thelargest systems. Add tothe lo-side. Easily workson all system pressuresto 300 psi, .35 oz. perstroke. Hose includedwith SealRight end.CHARGINGSYSTEMSEDITION 70 CATALOG85

UNIVERSAL A/CDYE SOLUTIONSFLUORESCENT SCANNER SOLUTIONSTechnology to match refrigerant and system volumeSYSTEM TOOLSHEATINGINSTRUMENTSLEAK DETECTORSAND MONITORSWIRELESS ANDELECTRONICINSTRUMENTSHOSE ADAPTERS,VALVES & PARTSVACUUM ANDCHARGING HOSESVACUUM LLOW JACKET HVAC/R86Universal dye for A/C systems with mineral,alkyl benzene or polyol ester lubricants.69621 Field proven and sold worldwide Passed thermal stability tests One dye for AC/R systems Raw material QC assures dye uniformity Made in the 8031/4 oz. (7.5 ml) Universal A/C (24 pak)1/2 oz. (15 ml) Universal A/C (12 pak)1 oz. (30 ml) Universal A/C (6 pak)2 oz. (60 ml) Universal A/C (6 pak)8 oz. (240 ml) Universal A/C8 oz. (240 ml) Universal A/C (6 pak)1 gal. (3.78 L) Universal A/COil/fluid and coolant dyes available on page 87.DYE APPLICATION AMOUNTSApplicationSmall applianceA/C or refrigerant systemsLarger systemsSystem size in lbs. of refrigerantUp to 4.9 lbs. (2.22 kg)Up to 25 lbs. (11.34 kg)Above 25 lbs. (11.34 kg)Universal dye amount0.25 oz. (7.5 ml)0.5 oz. (15 ml)0.5 oz. (15 ml) per gallon of oilNot recommended for systems withinternal temperatures below -40ºF.Compatible with mineral, alkylbenzene,ester and PAG oil systems.Different concentrations of fluorescentsolutions are available to match therefrigerant volume in a system. Operating temperature is -40 F for allsolutions01 – Systems with up to 2.9 lbs. gas1 – Systems with 1 to 4.9 lbs. gas2 – Systems with 5 to 9.9 lbs. gas3 – Systems with 10 to 25 lbs. gas When working on split systems, use solution3 even if system has 10 lbs. or less of gas Made in the USASelf-infusing Injector TubesSolutionConcern01 (0.03 oz.)1 (0.5 oz.)2 (0.5 oz.)3 (0.5 oz.)*SystemSizeup to 2.9 lbs.up to 4.9 lbs.up to 9.9 lbs.up to 25 lbs.Ester OilSystem69620696216962269623

FLUORESCENT SOLUTIONSCLEANERSFor non-refrigerant applicationsUPC#Description6973369734697351 oz. (30 ml) Oil and fluid dye (6 pak)1 oz. (30 ml) Oil and fluid dye (24 pak)8 oz. (240 ml) Oil and fluid dyeGAUGESThe oil and fluiddye solution is forfinding leaks in oilbased applications.Use 1 oz. per2 gallons of oil.CHARGINGSYSTEMSEDITION 70 CATALOG Find seal and gasket leaks in engines,compressors and transmissionsYELLOW JACKET solutionsmeet or exceed applicableASHRAE and ANSI testsand SAE standard J2297 forR-134a UV leak detection. Made in the USAScan-off UV CleanerWater-based biodegradable spray cleansscanner solution from system.Hand CleanerCleans solution from hands.Detects all hydrocarbonand other combustible gasesincluding propane, methane,butane, industrial solventsand more.APPLICATIONS: Internal gaslines/pipes Propane fillingstations Gas heaters CombustionappliancesSpecificationsWarm up time: 25 secondsIf no leak is detected in a suspected area, select high sensitivity. This will detect even lowlevels in the area. Move the tip over more defined areas, and you will be alerted when the tipencounters the concentration at the leak source.Power battery: 4 AA alkaline batteries,20 hours continuous life U ltra-sensitive sensor detects less than 15 ppm methane and better than 12 ppm forpropane. Performs equally well on a complete list of detectable gases including acetylene,butane and isobutaneBody length: 10.5" (26.67 cm)Probe length: 17" (43.17 cm)Sensor life: 500 hoursWeight: 16 oz. (0.45kg)Operating temperature range: 32 to 110 F(0 to 43 C)UPC#Description Smart Alarm LED shows how big or small a leak is on a scale of one to 9.6937169372693736938769379Replacement sensorReplacement sensor coverCombustible gas detector with caseCarrying case – blow moldedBattery cover and screw (2003-2011) 24-month limited warranty (12-month warranty on sensor) Made in USASYSTEM TOOLS S ensor replacable after full service lifeHEATINGINSTRUMENTS Automatic calibration and zeroingLEAK DETECTORSAND MONITORS Hydrocarbonrefrigerant Heat exchangers Marine bilges Manholes Air quality Arson residue(accelerants)WIRELESS ANDELECTRONICINSTRUMENTSUnit is preset at normalsensitivity, but you can switchto high or low. Slow beepingindicates that unit is warmedup. Frequency increaseswhen a leak is detecteduntil an alarm soundswhen moving into high gasconcentration. The SmartAlarm LED indicatesleak size.Description19 oz. Natural degreaser #0102016 oz. Hand cleaner8 oz. Scan-off solution8 oz. Scan-off solution (12 pak)HOSE ADAPTERS,VALVES & PARTSCOMBUSTIBLE GAS DETECTORWith ultra-sensitive, long life sensorUPC#69698696996969669697VACUUM ANDCHARGING HOSESNatural DegreaserHeavy duty biodegradable degreaserremoves scanner solution from system.VACUUM PUMPSYSTEMS Locate leaks in gasoline or diesel fuelequipment, offset printing presses,injection-molding machines, locomotiveengine oil coolers and oil-cooled chillersRECOVERYMACHINES Pin point leaks inmilling machinesand hydraulicsystems such ascherry pickers87

69386 Leak sensor bottle 69387 Carrying case with inserts 69361 Zipper pouch AccuProBe II LEAK DETECTOR 69354 Low, normal and high sensitivity levels with audible signals to quickly and easily pinpoint leaks. The frequency of flashing from the electrolyte sensor tip increases as you get

Related Documents:

8 Leak Detection Techniques Using Vacuum Leak Detectors 8 9 Industrial Leak Test 9. 3 Fundamentals of Leak Detection . by a special apparatus and fed to the leak detector. This procedure can be carried out using either helium, refrigerants, SF6 as the test gas. . Leak test using vacuum gauges which are sensitive to the type of gas. 6

Components of voice alarm systems - strong loudspeakers /strong Components using radio links Carbon monoxide detectors - point detectors Multi sensor fire detectors - point detectors using both smoke and heat detection Multi- sensor fire detectors point detectors using /p div class "b_factrow b_twofr" div class "b_vlist2col" ul li div strong File Size: /strong 2MB /div /li /ul ul li div strong Page Count: /strong 280 /div /li /ul /div /div /div

helium leak detectors are used in a wide range of industries, from heavy industry right up to clean room applications. In this latter case, the dry versions of the leak detector are used. High-performance leak detectors are used where extremely short cycle times and fast reduction of helium background are required.

the tank itself, API standards prescribe provisions for leak prevention, leak detection, and leak containment. It is useful to distinguish between leak prevention, leak detection and leak containment to better understand the changes that have occurred in tank standards over the years. In simple terms, leak prevention is any process that is designed to deter a leak from occurring in the first .

LIST OF FIGURES . Number Page . 1.1 Subsea Development USA Gulf of Mexico 5 1.2(a) Liquid Only Leak 6 1.2(b) Gas Only Leak 6 2.1 Categorization of Leak Detection Technology Used 10 in this Study 2.1.1 Leak Detection by Acoustic Emission Method 12 2.1.2 Leak Detection by Sensor Tubes 14 2.1.3 Leak Detection by Fiber Optical Sensing 17 2.1.4 Leak Detection by Soil Monitoring 19

The wide range of leak rates from Besides the determination of the total several 100 mbar x l/s to below 10-11 mbar x l/s as they occur in practi-ce necessitates the use of different leak detection principles and hence leak detectors (see figure). leak tightness, it is usually important to locate the leak, quickly and precisely,

Material Safety Data Sheets are available from your authorized Swagelok representative or at swagelok.com. Liquid Leak Detectors Snoop and Real Cool Snoop liquid leak detectors detect gas leaks in hard-to-reach areas. Features Sustained bubble act

Emerson Commercial & Residential Solutions - Dixell S.r.l. - Z.I. Via dell'Industria, 27 - 32016 Alpago (BL) ITALY - Climate.Emerson.com - Dixell@Emerson.com. Gas leak detectors . New family MRLDS . PN 07/20 June. Dear Customer, we are pleased to announce that the new MRLDS gas leak detectors are now available. They are designed for