Refrigerant air dryersFX 1-22

Air treatment,a crucial investmentWhy you need quality airCompressed air contains oil, solid particles andwater vapors. Together, they form an abrasive,often acidic, oily sludge. Without air treatment,this murky mix will enter the compressedair system, corroding pipe work, damagingpneumatic tools and potentially compromisingfinal products.The cost of poor air qualityUntreated compressed air can causesubstantial problems and costs: Your air tools have less power, morefailures and, ultimately, a shorter lifetime. Materials and products that come intocontact with untreated air run the risk ofcontamination or damage. Compressed air pipe work will corrode,leading to leaks. For example, a small 3 mmleak causes a 3.7 kW per year loss. Thatmeans a waste of an estimated 1800.2 - Atlas Copco FX refrigerant dryers

Atlas Copco quality air,the smart choiceAtlas Copco FX: dependable dry airTo avoid condensation, compressed air must bedried. The Atlas Copco FX refrigerant dryer is areliable, cost effective and easy to use solution.Available in 23 sizes (7-1484 l/s or 14-3144 cfm),the FX offers a pressure dew point as low as 3 C/ 37.4 F for a wide range of applicationsand industries. The dryer can be used at differentpressures and consumes hardly any processedcompressed air.FX: the benefits add up Strong performance. Pressure dew point display. Straightforward reliability. Easy installation. Minimal maintenance. Significant cost savings.A complete quality air systemAtlas Copco offers complete quality air systemsthat provide the clean, dry air that supports youroperational needs.A name you can trustFor more than 100 years, you have turned toAtlas Copco for the better compressors in thebusiness. Our commitment to your operationalobjectives doesn’t end there. Atlas Copco airtreatment equipment is developed and testedin-house to offer you quality air with accuracy,reliability and efficiency. Why compromiseusing third party add-ons when you can extendthe Atlas Copco peace of mind to your entirecompressed air system?Atlas Copco FX refrigerant dryers - 3

FXRefrigerant dryersQuality air made easyDigital display: providespeace of mind throughprecise monitoring ofpressure dew point.Pressure dew point precisionThe FX comes in a wide range of sizes (7-1484 l/sor 14-3144 cfm) to offer a steady pressure dewpoint as low as 3 C/ 37.4 F. Its easy to use digitaldisplay precision-measures and monitors thepressure dew point and dryer performance.Low-noise rotarycompressor with integratedliquid separator: lasts longerthanks to limited vibrations,minimal moving parts, andreduced risk of leakage.New: digital displayHot environments Pressure dew point: exact measurementand visual monitoring.High ambient temperatures can put yourequipment to the test. The FX range offers severalhigh temperature models that ensure dependableperformance in conditions up to 46 C/115 F. Status: refrigerant compressor and fan. Alarms: high/low pressure dew pointand probe failure. Service warning.ReliableBuilt according to the stringent Atlas Copcostandards, the FX is made of high quality,generously sized components.Significant cost savings Increased reliability and lifetime oftools and equipment. Reduced pipe work leaks and thusa lower energy bill. Less equipment breakdowns andoperational interruptions. Minimal chance of product damageas a result of moisture carryover.4 - Atlas Copco FX refrigerant dryers

Refrigerant separator: no chance ofmoisture entering the compressed airsystem.Single electrical connection:allows for plug-and-play installation.Hot gas bypass: ensures stable pressuredew point and eliminatesthe possibility of condensate freezing.Easy access to key components forstraightforward servicing.Water separator: offers high efficiencyfor better pressure dew point.Your choice: standaloneor integrated?Compact designfor a smallfootprint.Sustainable refrigerantThe FX 8-16 comes with the more sustainableR410A refrigerant: -47% global warming potential (GWP). Zero ozone depletion potential (ODP). No chlorine. Only 0.1 C/0.18 F temperature glide reducesrefrigerant and compression energy use, andallows for a constant pressure dew point.The FX comes as a standalone dryer andas part of the full feature version of manyAtlas Copco compressors. Which oneis best for you? It all depends on yourrequirements and priorities Separate dryer: Plug-and-play installation. Single electrical connection. All units pre-commissioned. Self-regulating. Pressure dew point display with high/low pressure dew point alarm and statusof refrigerant, compressor and fan.Full feature: Saves space when footprint is a priority. Compressor and air treatmentcomponents are designed, built andtested to work together to provideoptimal quality air.Atlas Copco FX refrigerant dryers - 5

Technical specifications 50 hzFX refrigerant dryer range 50 HzOutlet pressure dew point 5 C/41 FModelInlet capacityPressure dropOutlet pressure dew point 3 C/37 FInlet capacityMaximumworkingpressurePressure ibarpsimminchmminchmminchkglbFX 3.7848419.0619423/4” MFX 013.7848419.0619423/4” MFX 013.7848419.0620443/4” MFX 013.7848419.0625553/4” MFX 013.7848419.0627603/4” MFX 014.5780431.65511121” FFX 37014.5780431.65511121” FFX 46018.1182932.64611351 1/2” FFX 46018.1182932.64681501 1/2” FFX 0546018.1182932.64731611 1/2” FFX .0558022.8393936.97901981 1/2” FFX .0558022.8393936.97901981 1/2” FFX .3573528.94100239.451282822” FFX .3573528.94100239.451463222” FFX .3573528.94100239.451583482” FFX .3573528.94100239.451854082” FFX 2.59102040.15156061.413257173” FFX 242.59102040.15156061.413357393” FFX 242.59102040.15156061.413507723” FFX 12344.2102040.15156061.41380838DN 125FX 982.6102040.15156061.415501213DN 125FX 09982.6102040.15156061.416001323DN 125FX 982.6102040.15156061.416501433DN 125Reference conditionsOptional filter selectionOutlet pressure dew point 5 C/41 FModelInlet capacityFilterl/sOutlet pressure dew point 3 C/37 FInlet capacityFilterAmbient temperature:25 CInlet temperature:35 CWorking pressure:7 bar (g)l/sFX 17UD9 6UD9 FX 212UD15 10UD15 LimitationsFX 316UD15 14UD15 FX 423UD25 20UD25 FX 535UD45 30UD45 Maximum ambient temperature:46 C*FX 645UD45 39UD45 Minimum ambient temperature:5 CFX 758UD60 50UD60 Maximum inlet temperature:55 C**FX 869UD100 60UD60 FX 979UD100 68UD100 FX 10100UD100 87UD100 FX 11125UD140 108UD140 FX 12148UD180 128UD140 FX 13192UD220 167UD180 FX 14230UD310 200UD220 FX 15288UD310 250UD310 FX 16345UD425 300UD310 FX 17424UD425 400UD425 FX 18530UD550 500UD550 FX 19618UD850 583UD850 FX 19.5795UD850 750UD850 FX 20883UD850 833UD850 FX 211236UD1400 1166UD1400 FX 221484UD1400 1800UD1400 6 - Atlas Copco FX refrigerant dryers*45 C for FX 22**60 C for FX 17-21NotesRefrigerant types:R134a for FX 1-5R404A for FX 6-7R410A for FX 8-16R404A for FX 17-22

Technical specifications 60 hzFX refrigerant dryer range 60 HzOutlet pressure dew point 5 C/41 FModelInlet capacityPressure dropOutlet pressure dew point 3 C/37 FInlet capacityPressure bFX 5013.848419.119423/4” NPTFX 735013.848419.119423/4” NPTFX 735013.848419.120443/4” NPTFX 735013.848419.125553/4” NPTFX 735013.848419.127603/4” NPTFX 737014.680431.7511121” NPTFX 9.737014.680431.7511121” NPTFX 2.046018.182932.6611351 1/2” NPTFX 2.046018.182932.6681501 1/2” NPTFX 022.046018.182932.6731611 1/2” NPTFX .058022.893937.0901981 1/2” NPTFX .058022.893937.0901981 1/2” NPTFX .3573528.9100236.41733812” NPTFX .3573528.9100236.41783922” NPTFX .3573528.9100236.41834042” NPTFX .3573528.9100236.41834042” NPTFX 2.59102040.15156061.413257173” NPTFX 242.59102040.15156061.413357393” NPTFX 242.59102040.15156061.413507723” NPTFX 12344.2102040.15156061.41380838DN 125FX 982.6102040.15156061.415501213DN 125FX 09982.6102040.15156061.416001323DN 125FX 982.6102040.15156061.416501433DN 125Optional filter selectionOutlet pressure dew point 5 C/41 FModelInlet capacityFiltercfmReference conditionsOutlet pressure dew point 3 C/37 FInlet capacityFilterAmbient temperature:100 FInlet temperature:100 FWorking pressure:102 psi (g)cfmFX 114UD9 13UD9 FX 224UD15 21UD15 FX 335UD15 30UD15 FX 449UD25 42UD25 FX 574UD45 64UD45 Maximum ambient temperature:115 F*41 F131 F**LimitationsFX 695UD45 83UD45 Minimum ambient temperature:FX 7122UD60 106UD60 Maximum inlet temperature:FX 8146UD100 127UD60 FX 9167UD100 144UD100 FX 10211UD100 184UD100 FX 11264UD140 229UD140 FX 12313UD180 271UD140 FX 13407UD220 354UD180 *113 F for FX 22**140 F for FX 17-21NotesFX 14488UD310 424UD220 FX 15611UD310 530UD310 R404A for FX 6-7FX 16731UD425 636UD310 R410A for FX 8-16FX 17899UD425 848UD425 R404A for FX 17-22FX 181124UD550 1060UD550 UD850 FX 191310UD850 1236FX 19.51685UD850 1527UD850 FX 201872UD850 1766UD850 FX 212516UD1400 2374UD1400 FX 223144UD1400 3814UD1400 Refrigerant types:R134a for FX 1-5Atlas Copco FX refrigerant dryers - 7

Committed to sustainable productivityWe stand by our responsibilities towards our customers, towards the environment and the people around us.We make performance stand the test of time. This is what we call – Sustainable Productivity.2935 0880 47 2018, Atlas Copco Airpower NV, Belgium. All rights reserved.Designs and specifications are subject to change without notice or obligation.Read all safety instructions in the manual before usage.8 - Atlas Copco FX refrigerant dryers

Atlas Copco FX refrigerant dryers - 3 Atlas Copco quality air, the smart choice Atlas Copco FX: dependable dry air To avoid condensation, compressed air must be dried. The Atlas Copco FX refrigerant dryer is a reliable, cost effective and easy to use solution. Available in 23 sizes (7-1484 l/s or 14-3144 cfm),

Related Documents:

2 - Atlas Copco FX refrigerant dryers Atlas Copco FX refrigerant dryers - 3 AIR TREATMENT , A CRUCIAL INVESTMENT ATLAS COPCO QUALITY AIR, THE SMART CHOICE WHY YOU NEED QUALITY AIR Compressed air contains oil, solid particles and water vapors. Together, they form an abrasive, often acidic, oily sludge. Without air treatment,

FreeZone Benchtop Shell Freezers 31 Carts, Shelves & Gauges 32 Specifications reeze Dryers F 33 Triad Freeze Dryers 34 Stoppering Tray Dryers 35 Bulk & Small Tray Dryers 36 Legacy Freeze Dryers 37 labconco.com 2. The best materials. Our mission is to build your equipment to the highest

KLASIFIKASI MESIN PENGERING MESIN PENGERING Mesin Pengering Langsung Mesin Pengering Tak Langsung Mesin Pengering Infra red,radiant heat,dielectric Continuous Batch Continuous Batch 1. Continuous tray 2. Continuous sheeting 3. Pneumatic conveying dryers 4. Rotary dryers 5. Spray dryers 6. Trough circulation dryers 7. Tunnel dryers 8. Fluid bed .

Refrigerant flow diagram Air and refrigerant flow diagram of QED 1250-2100 dryers Description Refrigerant compressor (209) delivers hot, high-pressure refrigerant gas, which flows through condenser (202), where most of the refrigerant condenses. Instruction book

AirCel VF and AR Series . incoming hot air before leaving the dryer. Air Inlet Air Outlet Air-to-Air Heat Exchanger Stainless Steel Mist Eliminator Separation Cell Air -To-Refrigerant Heat Exchanger Refrigerant Outlet Refrigerant

calculation.pdf for further information. 02 Leak rate (% per year) pounds of refrigerant added pounds of refrigerant in full charge x 365 days / year shorter of #days since refrigerant last added or 365 days x 100% Leak rate (% per year) pounds of refrigerant added over past 365 days pounds of refrigerant in full charge x 100%

Do not touch the refrigerant pipes during and immediately after operation as the refrigerant pipes may be hot or cold, depending on the condition of the refrigerant flowing through the refrigerant piping, compressor, and other refrigerant cycle parts. Your hands may suffer burns or frostbite if you touch the refrigerant pipes.

automotive propulsion since the 1900s, a focussed effort on improved thermal efficiency, systems optimisation, hybridisation and new net-zero carbon fuels is required to meet stricter emissions regulations. Engine efficiency, commonly measured as Brake Thermal Efficiency, has continued to increase since the last TPS roadmap was published in 2017. For light duty vehicles, this is expected .