Molded Case Circuit BreakersExternal AccessoriesSelectionHandle TiesProvide simultaneous switching of 2 adjacent handles. Do not provide common trip.For Use WithBreaker Frame(s)CatalogNumberBQ, BQH, HBQ, BLH, HBLQTH3BQXD, BL, BQ, BQH,HBQ, BLH, HBLListPrice StandardPackageWt Lb/Std Pkg3.40 501QLD37.90/10 101One pole BL, BLF, BE, BAFPLD18.10101Two-pole BL, BLF and BEPLD28.30101All QJHL941913.50101All BQD, CQDBQDPLD16.40011NGGHPLG16.00011EGHPLE14.00011All EDED2HPL14.30011All FDFD6PL113.40011All JD, LD, LMDJD6HPL21.50011All MD, ND, PD, RDMN6PLD55.00011STDSTDPLD 117.000112.30011 4Padlocking DevicesFor locking breaker in “OFF” position. 4 4 4 8 4 4 4 4 4 4Filler PlatesBQ, BQH, HBQQF3QTH3 4FD PadlockingDeviceFD6PLIPadlockingDeviceQLD3 4Handle Blocking DevicesFor holding breaker in “ON” or “OFF” position. Not a lockout/tagout device.BL, BLH, HBL, BQXD,BQ, BQH, HBQQL17.80 25 12.002519.500111 4QJ2, QJH2, QJ2H, HQJ2HQJHS1All BQD, CQD, NGGBQDHBDEGHBDE14.00011All EDE2HBL14.30011All FDFD6HB116.40011All JD, LD, LMDJD6HBL19.60011All MD, ND, PD, RDMN6BL55.0001198.00012 4Filler PlateQF3 4 4 2 2 2Handle ExtensionsFor replacement. One extension shipped with breaker.All MD, ND, PD, RDEX11STDEXSTD 122.00Replacement Terminal CoverNGGRTCG3CSO 0101 4FD HandleBlocking DeviceFD6HB1HandleBlocking DeviceQL1Terminal ShieldsBreaker TypePolesCatalogNumberListPrice StandardPackageNGG (Line Side)3TSSG3A25.001NGG (Load 32.0010All EGHandleExtensionEX11 Built to order. Allow 2–3 weeks for delivery.Note: CSO Consult Sales Office Sold only in standard package quantities.17/72Discount Code: FSiemens Energy & Automation, Inc.Industrial Controls Catalog

Molded Case Circuit BreakersExternal AccessoriesSelectionMounting ClipsFor Use WithBreaker Frame(s)Number ofPolesCatalogNumberListPrice StandardPackageWt LbStd PkgBQ, BQH1MB1207.6020 1 4MB120Face Mounting Plates123FP9508FP9555FP955612.0015.2016.4010 10 10 1BQ, BQH, BQXD123CQDFMB1CQDFMB2 CQDFMB3 25.0028.0031.501111CQD, CQD6BQ-GFCI1FP9558 12.7010 1111130 11 2NGG123FMPG1FMPG2FMPG324.0026.5030.00SMB64.70 2111 2 4 41 41Face Mounting PlatesFP9558 FP9508 FP9555 FP9556 4 4 411Shallow Mounting BracketsBQ, BQH1–6Back Mounting PlatesAll QP 1 and 2 pole1, 2SMT70024.5011All QP 3-pole3SMT70339.0011234BR2BR3BR415.2015.2015.2010 10 10 11E2BMB12.7011CQD, CQD6CQDSMK 15.90111 4NGGMSKG4 3.5011All QJMSQJ 3.9011MSE6 MSE6100 3.900.901100 1All ED (CED6 requires 2 kits)MSF6 MSF650 3.900.90150 1All FD (CFD6 requires 2 kits)All EG 2 poleMSKE24.50——All EG 3 or 4 poleMSKE45.50——All JD, LDMSJ6 12.7011All LMDMSLMD21.5011All MD, ND,MSMN21.5011All PD, RDMSPR651.0012BQ, BQH, BQXDED2, ED4, ED6, HED4, HED6 4 4SMB6 (6 shown)QML12Back MountingPlate BR2SMT700 41 41 4 4Mounting Screw Kits 4 41 41 4 4 4Mounting Screw KitMSE6“MI” Mechanical InterlocksFor Use WithBreaker Type(s)Panel MountedBQ—QML1224.5010 All EG (sliding bar)HSBE—495.001—All EGWBMEFM—540.001—All QJCSO——All FDMI5444MI5444540.001—All JD, LDMI5413 —540.0011All LMDMI5406 —540.0011All MDMI5404 —540.0013 Plug-inMountedListPrice StandardPackageComplete with0two breakersWt LbStd Pkg1 41All NDMI5404 —540.0013All PD, RDMI5405 —621.00——STDSTDMIF32 —3609.00—— Built to order. Allow 2–3 weeks for delivery. Built to order. Allow 6–8 weeks for delivery.Note: CSO Consult Sales Office Kit consists of 4 screws and washers. Consists of 1 screw and washers (order 100). Consists of 1 screw and washers (order 50).Siemens Energy & Automation, Inc.Industrial Controls CatalogMechanical InterlockMI5444 With Each Addition Mechanicalmechanical interlock in place, no accessory can beinstalled into circuit breaker right pole.of the mechanical interlock will preventaccessory installation in the left pole. Sold only in standard package quantities. Multiply ListPrice Each times package quantity for full price.Discount Code: Fpackage contains 5 strips of 6 each. Each strip canbe broken at perforations for 1, 2 or 3-pole use.interlock is not designed for use withinSiemens panelboards.17/73

Molded Case Circuit BreakersExternal AccessoriesSelectionRotary Door Mounted Operating HandlesTypes 1, 3, 3R , 12, 4 4XComplete MechanismFor UseCatalog NumberWithBreaker StandardVariableFrames DepthDepthHandle OnlyBreaker Operator Shaft OnlyListCatalog ListCatalogPrice Number Price NumberListLength CatalogPrice (inches) NumberEGRHVE64XRHVE124XCSO——ED 2190.50RHOFBO 117.00CRHOH 45.5012JD, LD CRHOJSD CRHOJVD 263.50RHOJBO 190.0016LMDCRHOLMSD CRHOLMVD 263.50RHOLMBO 190.00MD, ND RHONSDPD, RDRHONVD403.00 RHOH——RHOSSD28.00RHOSVD28.00RHOSXD28.00RHONSSD 86.00RHONSVD86.00RHONSXD 114.003214.00 1224103.00 RHONBOListPrice CRHOHRHOHFor 3 or 3R, order shaft and breaker operator as shown, and handle RHOH. For 4 & 4X, order handle RHOH4. List Price 134.00Rotary Door Mounted Operating HandlesTypes 1 & 12Standard DepthVariable DepthHandle and ShaftListCatalogPrice NumberListPrice CatalogNumberListPrice CatalogNumberCQD, NGG—EDD11CEU1—RHOCQVD ��FDD11CFU1 177.00D11CFU2214.00————JD, ker OperatorFor Use WithCatalogBreaker Frames NumberListPrice For CQD and NGG red emergency handle, order assembly RHOCQVDE (includes handle and operator).For CQD and NGG in a NEMA 3R enclosure, order CQDOP34 operator ( 81.00), RHOH handle and RHOSVD shaft.For CQD and NGG in a NEMA 4 or 4X enclosure, order CQDOP34 operator, RHOH4 handle and RHOSVD shaft.Rotary Door MountedOperating HandlesThrough Door Mounted Operating Handles Types 1 & 12Standard DepthFor Use WithBreaker FramesCatalogNumberCQD, NGGFMHOSQJOH9498 EGEDFDVariable DepthListPrice CatalogNumber90.00ListPrice RH1Door Latch KitsTypeCatalog NumberRight HandListPrice Catalog NumberLeft HandListPrice 2 point latchDKR2302.00DKL2 302.003 point latchDKR3337.00DKL3 337.00Variable DepthRotary HandleRHOCQVD Built to order. Allow 2–3 weeks for delivery. Built to order. Allow 6–8 weeks for delivery. For use on 3-pole ED frame only.17/74F6RHV9 Meets the requirements of NFPA 79, section 5.3.3.1for locking external operator disconnecting devices.Discount Code: FSiemens Energy & Automation, Inc.Industrial Controls Catalog

Molded Case Circuit BreakersExternal AccessoriesSelectionMax-Flex , Flange Mounted Variable Depth Operators햴Complete KitHandle OnlyListPrice FramesNEMATypeEG1, 3 (R),MFKE3햵12CSO——4 (x)CSO——EDFDJD, LD,SJD, SLDLMDCatalogNumberBreaker OperatorListPrice MFKE4X3CatalogNumber1, 3 (R),FHOE036 햲12563.00 FHOH282.004 (x)—386.00—FHOH41, 3 (R),FHOF03612625.00 FHOH282.004 (x)—386.00—FHOH41, 3 (R),FHOJ03612664.00 FHOH282.004 (x)—386.00—FHOH41, 3 (R),FHOLM036 664.00 FHOH12282.004 (x)FHOH4386.00857.00 FHOHN421.00——1, 3 (R),MD, ND,FHON04812PD, RD,SMD, SND,4 (x)—SPDCatalogNumber——FHOHN4ListPrice CatalogNumber—Handle—Breaker Operator햲FHOEBO144.00 FHOEC036 137.00Max Flex FHOFBO198.00 FHOFC036 144.00FHOJBO223.00 FHOJC036 159.00FHOLMBO 223.00 FHOJC036 159.00FHONBO—Cable36 CableListPrice 햳224.00 FHONC048 212.00563.00Max-Flex handles are available with solid black handles instead of the customary "red for on" flange handle. These arepreferred for use in IECmarkets, where red handles have specific meaning. Order components separately, appending theletter "i" to the catalog number (e.g. FHOHI).Alternate Length Cable OnlyEDFDJD/LD/LMDMD/ND/PD/RDCatalogInches NumberListCatalogPrice NumberListCatalogPrice NumberListCatalogPrice NumberListPrice EC060FHOEC072FHOEC084 FHOEC096FHOEC120 FHOEC144 FHOFC048FHOFC060FHOFC072FHOFC084 FHOFC096FHOFC120FHOFC144 FHOJC048FHOJC060FHOJC072FHOJC084 FHOJC096FHOJC120 FHOJC144 FHONC048FHONC060FHONC072FHONC084 FHONC096FHONC120 FHONC144 Handle Auxiliary SwitchFor use with Max-Flex and Rotary Door operators (FHOH and RHOH). 1 NO and 1 NC contact (Form C).For Use WithCatalog NumberList Price ED, FD, JD, LD, LMD, ND, PD, RD, SD, Max FlexHAS1167.00Fixed Depth Flange t Hand MountNEMATypeRight Hand MountCatalog NumberListPrice Catalog NumberListPrice 1, 3R, 12FDFBEL 246.00FDFBER 246.004, 4XFDFBEL4 329.00FDFBER4 329.001, 3R, 12FDFBFL 263.00FDFBFR 263.004, 4XFDFBFL4 349.00FDFBFR4 349.00Max-Flex handles are available with solid black handles instead of the customary "Red for On" flange handle. These arepreferred for use in IECmarkets, where red handles have specific meaning. Order components separately, appending theletter "i" to the catalog number (e.g. FHOHI). Built to order. Allow 6–8 weeks for delivery.햲 For 1- or 2-pole breaker order FHOED036 complete kit orFHOEDBO breaker operator only.Siemens Energy & Automation, Inc.Industrial Controls Catalog햳 48inch cable is standard length for M through R frameMax-Flex operators.햴 Meets requirements of NFPA 79, section 5.3.3.1 forlocking external operator disconnecting devicesDiscount Code: FFDFBFR햵 Consultsales office for additional cable lengths for EGFlex Shaft Operators.17/75

Molded Case Circuit BreakersExternal AccessoriesSelection/DimensionsNEG, HEG Motor OperatorsBreaker FrameVoltageCatalog NumberList Price EG120/240AC, 125VDCSEAERCSOTelemand Motor OperatorBreaker FrameED except CEDACVoltageHinged toOpen DownListPrice 120MOE61203018.00240MOE6240 3284.00ED motor operator opens downward.BreakerFrameDCVoltageHinged toOpen RightListPrice ACVoltageHinged toOpen RightListPrice FD2448125MOF6024DC MOF6048DC MOF6125DC 65.00JD, LD2448125MOJ6024DC MOJ6048DC MOJ6125DC 89.00LMD2448125MOLMD6024DC MOLMD6048DC MOLMD6125DC 003989.00MD, ND,PD, 505.00Telemand Motor OperatorFD, JD, LD, LMD, MD, ND, PD, RDFramesTo order FD through RD motor operators with Left side hinges, add “L” to catalog number (e.g. MOF6120L).List prices are the same. .504.551.606.849.707.58JD, LD, LMD11.007.500.798.349.857.74MD, ND, PD, RD16.009.00—9.8313.1310.13Front ViewOperating 214.713.2621023013.26EBottom ViewFor inches / millimeters conversion,see Application Data section. Built to order. Allow 6–8 weeks for delivery.17/76Discount Code: FSiemens Energy & Automation, Inc.Industrial Controls Catalog

Molded Case Circuit BreakersExternal AccessoriesSelectionPlug-In Mounting Assemblies, Including Base and Tulip Assemblies————2PC2637 PC2638 3PC265798.00158.0098.00PC2658158.002PC2637 3PC2657158.00PC2638 PC2658158.002PC4753 237.00PC4753 237.003PC4754309.00PC4754309.0098.0098.002PC4753 237.00PC4753 237.003PC4754309.00PC4754309.00All JDexcept CJD2PC5777 318.00PC5777 318.003PC5778527.00PC5778527.00Kit CJD, SCJD3PCCJD570.00PCCJD570.00All LDexcept CLD2PC5660 596.00PC5660 DKit CLD, SCLDAll MDAll ND3PCCLD2PC5662 1098.00PC5662 17PL4762PL4763PL5796PL5797 PCBERC3햷 CSOPCBERC4햷 CSO 34 ListPrice 7PL9698햴2PC5664 1516.00PC5664 1516.003PC5666 햴PC5666 햴1748.001748.00PL9699RS4755Tulip Assemblies SeparatelyRS47563 PoleListPrice CatalogNumberListPrice EDTCE2 122.00TCE3 184.00FDTCF2 184.00TCF3 275.00JDTCJ2 213.00TCJ3 309.00LDTCL2 245.00TCL3 366.00MDTCM2 275.00TCM3 408.00NDTCN2 366.00TCN3 428.00 CatalogNumberCircuit BreakerWith Rear-Connecting StudsRear-Connecting StudsFor onBehindBreaker(inches)Line SideCatalogNumberLoad SideListPrice 햵CatalogNumberListPrice 햵All ED100100100100Line Side (Short)Load Side (Short)Line Side (Long)Load Side (Long)2.382.384.884.88RS2643햶 —RS2641햶 —40.50—47.50——RS2644햶 —RS2642햶 —40.50—47.50All FD250250ShortLong3.127.06RS4756햶 RS4755햶 58.0091.00RS4756햶 RS4755햶 58.0091.00All JD400400ShortLong5.8511.20RS5774 RS5773 161.00161.00RS5774 RS5773 161.00161.00All LD600600ShortLong5.8511.20RS5784 RS5783 192.00181.00RS5784 RS5783 192.00181.00CJD, SCJDCLD, SCLDLM(X)D6,HLM(X)D6All MD,NDAdd required shield kit.CLRSJL345.500800ShortLong5.8511.20RS5788 RS5787 297.00280.00RS5788 RS5787 297.00280.0012001200ShortLong5.508.00RS5786 RS5785 231.00291.00RS5786 RS5785 231.00291.00 Built to order. Allow 6–8 weeks for delivery.햲 Furnished at no extra charge when ordered with plug-inmounting assembly.햳 Each piece catalog number consists of (1) mountingblock assembly and required tulip assemblies (2) for2-pole, (3) for 3-poleSiemens Energy & Automation, Inc.Industrial Controls Catalog 2 PoleForFrame All FDexcept CFDCatalogNumber햳 CEDListPrice All EDexcept CEDCatalogNumber햳 EGPolesBaseSteel SwitchboardMounting Plate 햲Catalog Number For Use WithBreaker FramesLoad Side Line Side햴 Forvertical bus mounting — for horizontal, substitutePC5665 for PC5664 and PC5667 for PC5666.includes one current stud, insulating tube, studnuts and terminal shields, when required.햵 PriceDiscount Code: F햶 Forproper electrical clearance, studs must alternatebetween short and long stud lengths on circuit breakerpoles (e.g. SLSLSL or LSLSLS).햷 Plug-in assembly for EG breakers include line and loadside in one assembly.17/77

Industrial Controls Catalog Discount Code: F Siemens / Industrial Controls Previous folio: 6-81 Speedfax 2005, 17/81 Selection Inc. talog OH ED FD JD/LD/LMD MD/ND/PD/RD Catalog List Catalog List Catalog List Catalog List Inches Number Price Number Price Number Price Number Price 048 FHOEC048 162.00 FHOFC048 172.00 FHOJC048 187.00 .

Related Documents:

molded-case circuit breakers (MCCB), insulated-case circuit breakers (ICCB) and low voltage power circuit breakers LVPCB). Insulated-case circuit breakers are designed to meet the standards for molded-case circuit breakers. Low voltage power circuit breakers comply with the following standards: ANSI Std. C37.16—Preferred Ratings

Molded Case Circuit Breakers M1-M4 Product Overview Features Series M Molded Case Circuit Breakers, 15 - 600A NOARK Electric offers a complete range of Molded Case Circuit Breakers in four frame sizes: 100AF, 225AF, 400AF and 600AF. Each frame offers a choice of interrupting ratings at voltages ranging from 240VAC to 690VAC and 250VDC to 600VDC.

FORMULA Molded case circuit breakers 1 FORMULA Molded case circuit breakers Introduction ABB's FORMULA molded case circuit breaker line offers simplicity and quality in some of the smallest dimensions available. The A1 breaker frame size ranges in amperes from 15 through 100 and the A2 breaker frame size ranges from 125 through 250 amperes .

Siemens Industry, Inc. SPEEDFAX 2017 Product Catalog 7-3 7 MOLDED CASE CIRCUIT BREAKERS Siemens / Speedfax Previous folio: 6-2 What’s new in molded case circuit breakers: The development of VL Circuit Breaker enclosures for the150A and 250A breakers demonstrates a significant

Air Circuit Breakers Fixed Version for Power Distribution Emax 2 Icu 100kA - 200kA 4.14 . Air Circuit Breakers Accessories 4.16. 4 1SWC 010 000 C 0314 7 Circuit Breakers: 2 ABB SA LV Products Prices exclude VAT, subject to change without notice E & O.E. Terms & Conditions Apply Moulded Case Circuit Breakers

II - UL FORMULA Molded Case Circuit Breakers FORMULA. Simplicity and Quality in a Single Product. FORMULA is the cumulation of ABB SACE's long history of developing effective circuit breakers. It was developed to be simple, but amazes with its extreme quality and versatility. The highlights of the new line of molded case circuit breakers include:

Section 1—General Information, provides an overview of electronic trip molded case circuit breakers. Section 2—MICROLOGIC Trip Systems Based On LE, LX, LXI, ME, MX, NE, NX, PE and PX Circuit Breakers, provides information about the electronic trip systems used in LE, LX, LXI, ME, MX, NE, NX, PE and PX circuit breakers only.

FAZ-NA (RT) Molded Case Circuit Breakers are UL Listed for use in the United States in accordance with NFPA 70 (NEC). The devices comply with UL 489 and CSA 22.2 No. 5-02, meeting the requirements for Molded Case Circuit Breakers. These de- vices also comply with IEC 60947-2 and are CE compliant. series FAZ branch circuit breakers