LY General Purpose Relay Data Sheet - Engineered Air

2y ago
24 Views
2 Downloads
544.33 KB
15 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Casen Newsome
Transcription

General Purpose RelayLY Arc barrier equipped. High dielectric strength (2,000 VAC). Long dependable service life assured by AgCdO contacts. Choose models with single or bifurcated contacts,LED indicator, diode surge suppression,push-to-test button, or RC circuit. All models meet UL and CSAapprovals; VDE, LR, and SEVapproved versions are available.Ordering InformationTo Order: Select the part number and add the desired coil voltage rating (e.g., LY1-DC6).TypeTerminalContactformModelSingle erPCBLED indicatorPlug-in/solderDiode surgesuppressionUppermountingbracketBifurcated ———4PDTLY4-D—————LED indicatorand diode C �—LY2ZN-CR——LED indicatorand RC circuitNote: 1. Types with specifications other than those listed are available. Contact your Omron Sales representative.2. To order connecting sockets and mounting tracks, see “Accessories” section.1General Purpose RelayLY

TypeTerminalContactformModelSingle ug-in/solderLED indicator andpush-to-test buttonPlug-in/solderUppermountingbracketBifurcated ��—LY2Zl2N——4PDTLY4l4N—————Note: 1. Types with specifications other than those listed are available. Contact your Omron Sales representative.2. To order connecting sockets and mounting tracks, see “Accessories” section. AccessoriesConnecting SocketsTo Order: Select the appropriate part numbers for sockets, clips, and mounting tracks (if required) from the following charts.Track Mounted SocketsRelaySocket*Relay hold-down clipStandardSPDTPTF08A-EMounting trackRC circuitPYC-A1Y92H-3PFP-100N/PFP-50N &DPDTPFP-M or PFP-100N23PDTPTF11A4PDTPTF14A-EPFP-S (Option spacer)* Track mounted socket can be used as a front connecting socket.Back Connecting SocketsRelaySPDTSolderterminalsocketPT08Wire wrapterminalsocketPT08QNRelay hold-down clipStandardPYC-PPush-to-testRC circuitPYC-P2PYC-1Socket Mounting PlateMtg. ��Note: Types PYP-18, PTP-12 and PTP-10 may be cut to any desired length.RelayPC terminal socketRelay hold-down clipStandardSPDTPT08-0PYC-PPush-to-testPYC-P2RC circuitPYC-1DPDT3PDTPT11-04PDTPT14-0General Purpose RelayLY2

Specifications Contact DataLoadSingle contactSPDTResistive load(p.f. 1)Rated loadBifurcated contactDPDT, 3PDT, 4PDTInductive load(p.f. 0.4)(L/R 7 ms)Resistive load(p.f. 1)DPDTInductive load(p.f. 0.4)(L/R 7 ms)Resistive load(p.f. 1)Inductive load(p.f. 0.4)(L/R 7 ms)15 A at 110 VAC10 A at 110 VAC10 A at 110 VAC7.5 A at 110 VAC5 A at 110 VAC4 A at 110 VAC15 A at 24 VDC7 A at 24 VDC10 A at 24 VDC5 A at 24 VDC5 A at 24 VDC4 A at 24 VDCContact materialAgCdOCarry current15 AMax. operatingvoltage250 VAC125 VDCMax. operatingcurrent15 AMax. switchingcapacity1,700 VA1,100 VA1,100 VA830 VA550 VA440 VA360 W170 W240 W120 W120 W100 WMin. permissibleload100 mA, 5 VDC10 A7A10 A7A10 mA, 5 VDC Coil Data1- and 2-pole Types – ACRatedvoltage (V)Rated current (mA)50 Hz60 HzCoilresistance(Ω)Coil inductance(ref. value) imumvoltage(% of rated voltage)80% max.30% min.110%Powerconsumption(VA, W)Approx.1.00 to 1.20(60 Hz)Approx.0.90 to 1.10(60 Hz)1- and 2-pole Types – DCRatedvoltage (V)Rated current (mA)Coilresistance(Ω)Coil inductance(ref. value) ximumvoltagePowerconsumption(VA, W)(% of rated voltage)80% max.10% min.110%Approx.0.90Note: 1. The rated current and coil resistance are measured at a coil temperature of 23 C (73 F) with tolerances of 15%, -20% for AC ratedcurrent, and 15% for DC rated coil resistance.2. The AC coil resistance and inductance are reference values at 60 Hz.3. The performance characteristics are measured at a coil temperature of 23 C (73 F).4. Class B coil insulation is available.3General Purpose Relay LY

3-pole Type – ACRatedvoltage (V)Rated current (mA)50 HzCoil inductance(ref. value) (H)Coilresistance(Ω)60 015.90/18.30 13.60/15.60 0.50/11.60 mption(VA, W)(% of rated voltage)80% max.30% min.110%Approx.1.60 to 2.00(60 Hz)3-pole Type – DCRatedvoltage(V)Rated current (mA)Coilresistance(Ω)Coil inductance(ref. value) tageMaximumvoltage(% of rated voltage)80% max.10% min.110%Powerconsumption(VA, W)Approx.1.404-pole Type – ACRatedvoltage (V)Rated current (mA)50 Hz60 HzCoilresistance(Ω)Coil inductance(ref. value) /11022.50/25.50 1.50/13.10 % of rated voltage)80% max.30% min.110%Powerconsumption(VA, W)Approx.1.95 to 2.50(60 Hz)4-pole Type – DCRatedvoltage (V)Rated current (mA)Coilresistance(Ω)Coil inductance(ref. value) oltagePowerconsumption(VA, W)(% of rated voltage)80% max.10% min.110%Approx.1.50Note: 1. The rated current and coil resistance are measured at a coil temperature of 23 C (73 F) with tolerances of 15%, -20% for AC ratedcurrent, and 15% for DC rated coil resistance.2. The AC coil resistance and inductance are reference values at 60 Hz.3. The performance characteristics are measured at a coil temperature of 23 C (73 F).4. Class B coil insulation is available.General Purpose RelayLY4

CharacteristicsContact resistance50 mΩ max.Operate time25 ms max.Release timeOperating frequency25 ms max.Mechanically18,000 operations/hourUnder rated load1,800 operations/hourInsulation resistance100 MΩ min. (at 500 VDC)Dielectric strength2,000 VAC, 50/60 Hz for 1 minute1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarityVibrationShockAmbient temperatureMechanical durability10 to 55 Hz, 1.00 mm (0.04 in) double amplitudeMalfunction durability10 to 55 Hz, 1.00 mm (0.04 in) double amplitudeMechanical durability1,000 m/s2 (approx. 100 G)Malfunction durability200 m/s2 (approx. 20 G)Operating-40 to 70 C (-40 to 158 F)Humidity35 to 85% RHService LifeMechanicallyAC: 50 million operations min. (at operating frequency of 18,000 operations/hour)DC: 100 million operations min. (at operating frequency of 18,000 operations/hour)ElectricallySee “Characteristic Data”WeightSPDT, DPDT: Approx. 40 g (1.41 oz), 3PDT: Approx. 50 g (1.76 oz)4PDT: Approx. 70 g (2.47 oz)Note: Data shown are of initial value. Characteristic DataMaximum switching capacityRated operating current (A)Rated operating voltage (V)Rated operating voltage (V)LY2ZRated operating current (A)LY3, LY4Rated operating current (A)LY2Rated operating current (A)LY1Rated operating voltage (V)Rated operating voltage (V)Electrical service lifeRated operating voltage (V)5Rated operating voltage (V)General Purpose Relay LYLY2ZRated operating current (A)Rated operating current (A)LY3, LY4Rated operating current (A)LY2Rated operating current (A)LY1Rated operating voltage (V)Rated operating voltage (V)

DimensionsUnit: mm (inch) RelaysLY1Terminalarrangement(Bottom view)LY2LY3Terminalarrangement(Bottom view)LY4LY1-0, LY2-0, LY3-0, LY4-0Terminalarrangement(Bottom view)Mounting holes for LY1-0, LY2-0, LY3-0, LY4-0(Bottom view)Note: The above drawing shows LY2-0. With LY1-0,dimension “*” should read as eight 6.35 (.25).LY1F, LY2FTerminalarrangement(Bottom sNote: The above drawing shows LY1F. With LY2F, dimension “*”should read as eight 3.05 mm (0.12 in) dia. holes.General Purpose RelayLY6

LY4FMounting holesLY1S, LY2SRound holeRectangular holeLY3SRound holeRectangular holeLY4SRound holeRectangular holeNote: The above drawing shows LY2S-US. With LY1S-US, dimension “*”should read as eight 2.03 mm (0.08 in) dia. holes.6General Purpose Relay LY

AccessoriesUnit: mm (inch)Track mounted sockets (UL File No. E87929) (CSA Report No. LR31928)PTF08A-ETerminal arrangement/mounting holes(Top view)PTF11ATerminal arrangement/mounting holes(Top view)Track mounting sockets (UL File No. E87929) (CSA Report No. LR31928)PTF14A-ETerminal arrangement/mounting holes(Top view)Mounting height ofrelay with socket(Applies to all PTF A sockets)Note: 1. UL/CSA does not apply to wire wrap (Q) type sockets.2. Values in brackets for LY CR.Back connecting socket (UL File No. E87929) (CSA Report No. LR31928)PT08Terminal arrangement/(Bottom view)PT11Terminal arrangement/(Bottom view)General Purpose RelayLY7

Back connecting socket (UL File No. E87929) (CSA Report No. LR31928)PT14Terminal arrangement(Bottom view)Mounting height of relay with socket(Applies to all PT sockets)PTNote: Values in brackets for LY CR.Back connecting socket (UL File No. E87929) (CSA Report No. LR31928)PT11QNPanel cut-out and terminalarrangement are the sameas Type PT11.PT08QNPanel cut-out and terminalarrangement are the sameas Type PT08.PT14QNPanel cut-out and terminalarrangement are the sameas Type PT14.Back connecting socket (UL File No. E87929) (CSA Report No. LR31928)PT08-0Terminal arrangement isthe same as Type PT08.Mounting holes(Bottom view)PT11ATerminal arrangement isthe same as Type PT11.Back connecting socket (UL File No. E87929) (CSA Report No. LR31928)PT14-0Terminal arrangement isthe same as Type PT14.8Mounting holes(Bottom view)General Purpose Relay LYMounting holes(Bottom view)

Unit: mm (inch)Relay hold-down clipsPYC-A1For PTF A socketPYC-SFor relay mounting plates(Applicable to Type PYP-1 and PYP-18socket mounting plates only.)PYC-PFor PT socketY92H-3For RC circuit typePYC-1For RC circuit typeRelay hold-down clipsPYC-P2For push-to-test button type withPT socketMounting track/end plate/spacerPFP-100N/PFP-50N mounting trackPFP-M end plateGeneral Purpose RelayLY9

PFP-100N2 mounting track******PFP-S spacerThis dimension is 14.99 mm (0.59 in) on both ends in the case of PFP-100N, but on one end in the case of PFP-50N.L LengthPFP-50N. L 497.84 mm (19.60 in)PFP-100N . L 990.60 mm (39.00 in)PFP-100N2 . L 990.60 mm (39.00 in)A total of twelve 24.89 x 4.57 mm (0.98 x 0.18 in) elliptic holes are provided, with six holes cut from each end of the track at a pitchof 9.91 (0.39) between holes.Socket mounting plates [t 1.52 (.06)]PYP-1PTP-1-3PTP-1010Number of socket specs.Socket needed1101218PT08, PT08QNPYP-1––PYP-18PT11, PT11QNPTP-1-3–PTP-1-2PT14, 12General Purpose Relay LY

Relay OptionsLED IndicatorSpecifications and dimensions same as the Standard Type with the following exception. With the LED indicator type, the rated current is approximately 0 to 5.0 mA higher than the Standard Type.Terminal arrangement/Internal connections (Bottom view)LY2NDC coil rating typeAC coil rating typeNote: 1. The coil terminals 10 and 11 of Type LY3N become (-) and ( ) and terminals 13 and 14 of Type LY4N become (-) and ( ), respectively.2. Pay special attention to the polarities when using the DC type.Diode Surge SuppressionSpecifications and dimensions same as the Standard Type with the following exception. Ambient operating temperature: -25 to 40 C(-13 to 104 F)Without DiodeWith DiodeTerminal arrangement/Internal connections (Bottom view)LY2(N)-D(2)LY2-D6, 12, 24, 48100/110 VDCNote: 1.2.3.4.LY2N-D26, 12, 24, 48 VDCLY2N-D2100/110 VDCPay special attention to the polarities when using the DC type.The release time is somewhat longer, but satisfies the standard specifications of 25 ms.The reverse-breakdown voltage of the diode is 1,000 VDC.Available on DC versions only.General Purpose RelayLY11

Relay OptionsRC CircuitSpecifications and dimensions same as the Standard Type with the following exceptions.Characteristic DataWithout RC circuitWith RC circuitLY1-CR, LY2(Z)-CRTerminal arrangement/Internal connections (Bottom view)LY1-CRLY2(Z)-CRNote: 1. The above drawing shows LY2(Z)-CR. With LY1-CR, “*” should read eight 2.03 mm (0.08 in) dia. holes.2. Available on AC versions only.Push-to-test ButtonSpecifications and dimensions same as the Standard Type with the following exceptions.LY 12LY112, LY212Note: Type LY112 has the same dimensions and appearances as Type LY212 shown except that dimensions “*” is 2.03 mm (0.08 in) dia. holes.LY31212LY412General Purpose Relay LY

ApprovalsUL Recognized Type (File No. E41643)TypeLY Contact formSPDTCoil ratings6 to 240 VAC6 to 120 VDCContact ratings15 A, 240 VAC (Inductive)15 A, 28 VDC (Resistive)TV-5 (ACTV)1/2 HP, 120 VAC (Motor)LY DPDT13 A, 120 VAC (Resistive)12 A, 240 VAC (Inductive)10 A, 28 VDC (Resistive)TV-3 (ACTV)1/2 HP, 120 VAC (Motor)LY 3PDT10 A, 240 VAC (Inductive)4PDT10 A, 28 VDC (Resistive)1/2 HP, 240 VAC (Motor)CSA Certified Type (File No. LR31928)TypeLY Contact formSPDTCoil ratings6 to 240 VAC6 to 120 VDCContact ratings15 A, 120 VAC (Inductive)10 A, 240 VAC (Inductive)15 A, 28 VDC (Resistive)TV-5 (ACTV)LY DPDT13 A, 28 VDC (Resistive)12 A, 120 VAC (Inductive)10 A, 240 VAC (Inductive)1/3 HP, 120 VAC (Motor)TV-3 (ACTV)LY 3PDT10 A, 240 VAC (Inductive)4PDT10 A, 28 VDC (Resistive)VDE Approved Type (File No. 9903 [SPDT, DPDT & 3PDT], File No. 9947 [4PDT])TypeLY -VDContact formSPDTCoil ratings6, 12, 24, 50,110, 220 VAC10 A, 28 VDC (Resistive)and 6, 12, 24,7 A, 220 VAC (Inductive)48, 110 VDCLY -VDContact ratings10 A, 220 VAC (Resistive)DPDT7 A, 28 VDC (Inductive)7 A, 220 VAC (Resistive)3PDT7 A, 28 VDC (Resistive)4PDT4 A, 220 VAC (Inductive)4 A, 28 VDC (Inductive)LR (Lloyd's Register) Approved Type (File No. 562KOB-204523)TypeLY Contact formCoil ratingsContact ratingsDPDT6 to 240 VAC7.5 A, 230 VAC (Inductive)4PDT6 to 110 VDC5 A, 24 VDC (Inductive)SEV Listed Type (File No. D7 91/82 [2- & 4-pole], D 91/204a [1- & 3-pole])TypeContact formCoil ratings6 to 240 VACContact ratingsLY -SVSPDTLY -SVDPDT10 A, 220 VAC (Resistive)3PDT10 A, 24 VDC (Resistive)6 to 110 VDC15 A, 220 VAC (Resistive)15 A, 24 VDC (Resistive)4PDTNote: 1. The rated values approved by each of the safety standards (e.g., UL, CSA, VDE, and SEV) may be different from the performance characteristics individually defined in this catalog.2. In the interest of product improvement, specifications are subject to change.General Purpose RelayLY13

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4OMRON ELECTRONICS LLCOMRON CANADA, INC.OMRON ON-LINEOne Commerce DriveSchaumburg, IL 60173885 Milner AvenueToronto, Ontario M1B 5V8847-882-2288416-286-6465Global - http://www.omron.comUSA - http://www.omron.com/oeiCanada - http://www.omron.caCat. No. GC RLY8145/03Specifications subject to change without noticeGeneral Purpose Relay LYPrinted in USA

Relay Socket* Relay hold-down clip Mounting track Standard RC circuit SPDT PTF08A-E PYC-A1 Y92H-3 PFP-100N/PFP-50N & DPDT PFP-M or PFP-100N2 3PDT PTF11A PFP-S (Option spacer) 4PDT PTF14A-E Relay Solder terminal socket Wire wrap terminal socket Relay hold-down clip Socket Mounting Plate Standard Push-to-test RC circuit Mtg. plate 1 10 12 18

Related Documents:

Nissan Micra - OWM 4734 Nissan Micra - OWM 4734 CPU E6 H33750 1 Battery 2 Ignition switch 3 Fusible link holder 4 Fuse box 5 Fuse and relay box a) accessory relay b) blower motor relay 6 Intelligent power distribution module a) starter relay b) cooling fan hi relay c) cooling fan lo relay d) fuel pump relay e) ignition relay f) ECM relay

38 - Check voltage output to fuel pump @ relay set 39 - Check voltage input to relay set from ignition switch 40 - Check voltage input to fuel pump relay of relay set 41 - Check input voltage to control relay of relay set 42 - Check input voltage to control relay of relay set (continued)

Power MOSFET Relay Specifications (G6D Relay) The following specifications apply to G6D Relays mounted in a G70D Relay Terminal and not the G6D Relay itself. Coil Ratings (per G6D Relay) Note: 1. The must-operate voltage is 75% or less of the rated voltage if the relay is mounted upside down. 2. Rated current and coil resistance were measured .

Results are provided for actual relay testing. Part I: Distance Relay Tests (Texas A&M University) Distance relay testing can evaluate relay performance, calibrate relay settings, and identify system conditions that could cause unexpected relay operation. Developing a relay testing methodology requires consideration of how to model the power .

Relay data and relay setting management Management of relay versions and models World‘s largest library with relay setting data models Library expandable by customer & via relay setting model generator Result import from different test device software: Omicron, Doble, Programma, etc.

Relay AE RLY-538 5 v 178 ohm Resistor DPDT 270 ohms ½ watt Control Tortoise with 5 volt Relay-12 volts DC 12 volts DC Relay On Off To Tortoise Relay “stick” contacts “On” Button powers relay, “stick” contact holds it on “Off” button bypasses relay coil so it drops out Can have any no. of

Relay Computer Harry Porter, Ph.D. Portland State University April 24, 2006. 2. 3 V. 4 Double Throw Relay. 5 V Double Throw Relay. 6 Four Pole, Double Throw Relay. 7 V Four Pole, Double Throw Relay. 8. 9 Schematic Diagrams. 10 Schematic Diagrams Assume other terminal is connected to ground. 11 Schematic Diagrams

Install Your Relay Switch Do not use this sensor in hazardous (classified) locations or life safety applications. Step 1: Mount your Relay Switch. Mount your Relay Switch with screws through the flange holes, secure it with Velcro or simply place it on a flat surface. Step 2: Connect your Relay Switch to AVTECH's Light Tower & Relay Adapter .