IS-C4L R - C6L RDownlightingCalculite LED Gen 3Retrofit KitRead and understand these instructionsBefore installing luminaire (fixture).This luminaire is intended for installation in accordance with the National Electrical Code and local regulations. Toassure full compliance with local codes and regulations, check with your local electrical inspector before installation.To prevent electrical shock, turn off electricity at fuse box before proceeding. Allow fixture to cool before handling.Retain these instructions for maintenance referenceInstallation for Calculite Trims:C4R & C4S SeriesC6R & C6S SeriesC6R R SeriesC7R Series Calculite RetrofitLight Engines:C4L R SeriesC4L RH SeriesC6L R SeriesC6L RH SeriesCAUTION: RISK OF FIRE, DO NOT INSTALL TRIM WITHIN 3INCHES OF INSULATION IN SUCH A MANNER SO AS TOENTRAP HEATCAUTION: For Use Only With ROUGH IN SECTIONS C4 LED SeriesC4L N SeriesC6L N SeriesC7L N SeriesC4X4 LED SeriesC4X4L N SeriesC6X6L N SeriesP4 SeriesP6 Series AS400 SeriesS4100 SeriesBS600 SeriesS6100 SeriesS6200 SeriesCS700 SeriesS7100 SeriesS7200 Series B600 Series6100 Series6200 SeriesC700 Series7100 Series7200 SeriesCAUTION: RISK OF FIRE USE ONLY WITH LED LIGHT ENGINES AND REFLECTOR TRIMS BY PHILIPS LIGHTOLIER. USE OF OTHERMANUFACTUERS TRIMS MAY VOID UNDERWRITERS LABORATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.WARNING: RISK OF FIRE OR ELECTRIC SHOCK. LED RETROFIT INSTALLATION REQUIRES KNOWLEDGE OF LUMINAIRES ELECTRICALSYSTEMS. IF NOT QUALIFIED, DO NOT ATTEMPT INSTALLATION. CONTACT A QUALIFIED ELECTRICIAN.WARNING: RISK OF FIRE OF ELECTRIC SHOCK. INSTALL THIS KIT ONLY IN THE LUMINAIRES THAT HAVE THE CONSTRUCTION FEATURESAND DIMENSIONS SHOWN IN THE PHOTOGRAPHS OR DRAWINGS AND WHERE THE INPUT RATING OF THE RETROFIT KIT DOES NOTEXCEED THE INPUT RATING OF THE LUMINAIRE.CAUTION: DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN ENCLOSURE OF WIRING OR ELECTRICAL COMPONENTS DURING KITINSTALLATION.WARNING: TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR OTHER SHARPOBJECTS. 2017 Philips Lighting Holding B.V. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any productat any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Philips.com/luminaires8/30/2017page 1Philips.com/luminaires

IS-C4L R - C6L RCalculite LED Gen 3 Retrofit KitInstructions for all applicationsFig. BFig. AStep 1Disconnect circuit power supply. Remove existing lamp /reflector trim from ceiling and dispose of properly (Fig. A).For existing LED luminaires disconnect & remove entiretrim assembly and dispose of properly (Fig. B).Step 2Disconnect any supply, ballast & thermal protector wiring.Remove existing ballast / LED driver including j-box door anddispose of correctly. For products with socket cups (Fig. C),trim wire leads close to J-box wall running to the socket cuppreventing re-use. For LED products (Fig. C), trim wire leadsclose to J-box wall running to the connector cover preventingre-use. If a thermal protector is used, trim or cap leads as toprevent re-using for this application. If removed from J-box,the hole left needs to be covered. Leave only Supply Wires,Dimming (if used) & Ground Wires in J-Box.Step 3Remove or rotate old trim retaining springs out of aperture holeto prevent interference with new fixture installation (Fig. C).Retrofit Frame ExamplesJ-BoxFig. CJ-BoxRetaining SpringsBallast / DriverRetaining SpringsSocket Cup(Multiple Types)Socket Cup(Multiple Types)J-BoxRetaining SpringsLED Driver / Ballast8/30/2017page 2Philips.com/luminairesLED Driver / BallastThermal ProtectorLocation (Optional)

IS-C4L R - C6L RCalculite LED Gen 3 Retrofit KitFig. DStep 4Place Label Information IL-4128-D on the retrofitted rough in section close to the original ULLabel. This label should come stapled on this Instruction Sheet.Step 5Remove the cardboard that is protecting the lens on the light engine.Step 6Fig. ESnap light engine to trim by aligning the indents on engine heatsink to the heatsinksprings on the trim (Fig. E). If the light engine is not properly aligned with the heatsink,damage will occur to the silicon lens.Heatsink Indents forspringsproper alignmentStep 7Use wire nuts to connect the black retrofit wire to the black source lead, the whiteretrofit wire to the white source lead, & tie the green retrofit wire, bare copper wire,and source ground wires together. Connect the new retrofit dimming wires to existingdimming leads (optional)TrimLight EngineStep 8Feed new driver and junction box door through aperture opening and install on toframe. Before closing new j-box door, be sure to place all leads & connections back intojunctions box with care not to pinch wiring.Fig. FStep 9Squeeze trim springs in order to push the trim into the ceiling (Fig. F). Adjustmentladders can be positioned every ¼” to fit various ceiling heights. To adjust, gentlydisengage shim on trim spring, slide spring to appropriate ladder setting, and allow toclick into place (Fig. G). For early LED frames, springs may need to be adjusted forframe height in addition to ceiling thickness.AdjustmentladderStep 10 (For 6100 Series, 6200 Series, B600 Frames Only)Retrofit Trim Springs are mounted upside down as shown in Fig H. Do not adjust trimspring heights as doing so may cause the trim to become unremovable without causingReflector damage from the die cast frame pan. For Install, follow steps 1 through 7. Foldsprings down and push trim through aperture until secure. 2017 Philips Lighting Holding B.V. All rights reserved. Philipsreserves the right to make changes in specifications and/or todiscontinue any product at any time without notice or obligationand will not be liable for any consequences resulting from the useof this publication. Philips.com/luminaires8/30/2017page 3Philips.com/luminairesTrim springsFig. GFig. H

IS-C4L R - C6L RÉclairage directKit de conversion DELCalculite 3e génVeuillez lire et bien comprendre cesinstructions avant d’installer ce luminaire.Ce luminaire est prévu pour une installation en conformité avec le National Electrical Code et aux réglementationslocales. Pour assurer une entière conformité aux codes et réglementations locaux, veuillez contacter un inspecteuren électricité avant de procéder à l’installation. Pour prévenir un choc électrique, couper l’électricité au coffret defusibles ou au disjoncteur avant de procéder. Permettre le refroidissement du luminaire avant de le manipuler.Conserver ces instructions comme référence pour l’entretien.Installation pourGénérateurs de lumièreDEL Calculite :Garnitures Calculite : Séries C4R et C4S Série C4L R Séries C6R et C6S Série C4L RH Série C6R R Série C6L R Série C7R Série C6L RHMISE EN GARDE : RISQUE D’INCENDIE, NE PAS INSTALLER LAGARNITURE À MOINS DE 3 PO DE TOUT MATÉRIAU ISOLANTAFIN D’ÉVITER D’EMPRISONNER LA CHALEURMISE EN GARDE : Pour usage avec les cadres de montageci-dessous exclusivement : Série C4 LEDSérie C4L NSérie C6L NSérie C7L NSérie C4X4 LEDSérie C4X4L NSérie C6X6L NSérie P4Série P6 Série AS400Série S4100Série BS600Série S6100Série S6200Série CS700Série S7100Série S7200 Série B600Série 6100Série 6200Série C700Série 7100Série 7200MISE EN GARDE : RISQUE D’INCENDIE, UTILISER UNIQUEMENT AVEC LES GÉNÉRATEURS DE LUMIÈRE DEL ET LES GARNITURESRÉFLECTEURS PAR PHILIPS LIGHTOLIER. L’UTILISATION DE GARNITURES PAR D’AUTRES FABRICANTS PEUT ANNULER L’HOMOLOGATIONPAR UNDERWRITERS LABORATORIES ET CONSTITUER UN RISQUE D’INCENDIE.AVERTISSEMENT : RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE. L’INSTALLATION DU KIT DE CONVERSION EXIGE LA CONNAISSANCEDES SYSTÈMES D’ÉCLAIRAGE ÉLECTRIQUES. À MOINS D’ÊTRE QUALIFIÉ, NE PAS TENTER L’INSTALLATION, CONTACTER UN ÉLECTRICIEN.AVERTISSEMENT : RISQUE D’INCENDIE OU DE CHOC ÉLECTRIQUE. INSTALLER CE KIT UNIQUEMENT DANS LES LUMINAIRES POSSÉDANTLES CARACTÉRISTIQUES DE CONSTRUCTION ET LES DIMENSIONS CORRESPONDANT AUX PHOTOGRAPHIES OU DESSINS ET LORSQUE LAPUISSANCE NOMINALE DU KIT DE CONVERSION N’EXCÈDE PAS LA PUISSANCE NOMINALE DU LUMINAIRE.MISE EN GARDE : NE PAS PERCER, NI MODIFIER AUCUNE OUVERTURE DANS UN BOÎTIER DE CÂBLAGE OU DE COMPOSANTSÉLECTRIQUES DURANT L’INSTALLATION DU KIT DE CONVERSION.AVERTISSEMENT : POUR EMPÊCHER LES DOMMAGES OU L’USURE DU CÂBLAGE, NE PAS EXPOSER LE CÂBLAGE AUX ARÊTES EN TÔLE OUÀ TOUT AUTRE OBJET COUPANT. 2017 Philips Lighting Holding B.V. Tous droits réservés. Philips se réserve le droit de modifier les spécifications et d’abandonner tout produit en tout temps, sans avispréalable ni obligation et décline toute responsabilité quant aux conséquences découlant de l’utilisation de cette publication. Philips.com/luminaires11/08/2017 page 4Philips.com/luminaires

IS-C4L R - C6L RKit de conversion DEL Calculite 3e générationInstructions pour toutes les applicationsÉtape 1Couper l’alimentation du circuit électrique. Retirer la lampeexistante et la garniture-réflecteur du plafond et en disposeradéquatement (Fig. A). Pour un luminaire DEL existant,déconnecter et retirer le groupe garniture au complet et endisposer adéquatement (Fig. B).Fig. BFig. AÉtape 2Déconnecter tout câblage d’alimentation, du ballast ou de laprotection thermique. Retirer le ballast/pilote DEL existant, incluantla porte de la boîte de jonction et en disposer adéquatement. Pourun produit avec boîtier de douille (Fig. C), couper les fils vers leboîtier de douille à la boîte de jonction pour en empêcher laréutilisation. Pour un produit DEL (Fig. C), couper les fils vers lecouvercle du connecteur à la boîte de jonction pour en empêcher laréutilisation. Si une protection thermique est utilisée, couper oucouvrir les fils pour en empêcher la réutilisation dans cetteapplication. Si retirée de la boîte de jonction, le trou laissé doit êtreobturé. Laisser seulement dans la boîte de jonction les filsd’alimentation, de gradation (s’il y a lieu) et les fils de MALT.Étape 3Enlever ou pivoter les ressorts de retenue vers l’extérieur del’ouverture pour empêcher l’interférence avec l’installation dunouvel appareil. (Fig. C).Exemples de cadrede montageBoîte de jonctionFig. CBoîte dejonctionBoîtier de douille(Divers types)Ressorts de retenueRessorts deretenueBallast / PiloteDELBoîtier de douille(Divers types)Boîte de jonctionRessorts deretenuePilote DEL / Ballast11/08/2017 page 5Philips.com/luminairesPilote DEL / BallastProtectionthermique (option)

IS-C4L R - C6L RKit de conversion DEL Calculite 3e générationFig. DÉtape 4Apposer l’étiquette d’Information IL-4128-D sur le cadre de montage rénové, près del’étiquette UL d’origine. L’étiquette devrait être brochée sur cette feuille d’instructions.Étape 5Enlever le carton qui protège la lentille sur le générateur de lumière DEL.Étape 6Fig. EEncliqueter le générateur de lumière à la garniture en alignant les encoches sur ledissipateur thermique avec les ressorts sur la garniture (Fig. E). Si le générateur de lumièren’est pas bien aligné avec le dissipateur thermique, la lentille en silicone sera endommagée.Ressorts duEncoches pourdiss. thermique l’alignementÉtape 7Utiliser des capuchons de connexion pour connecter le fil noir du kit au fil d’alimentationnoir, le fil blanc du kit au fil d’alimentation blanc et attacher ensemble le fil vert du kit, lefil de cuivre nu et les fils de terre de la source. Connecter les nouveaux fils de gradationaux fils de gradation existants (option).GarnitureGénérateurde lumièreDELÉtape 8Passer le nouveau pilote et la porte de la boîte de jonction par l’ouverture et installer surle cadre de montage. Avant de fermer la porte de la nouvelle boîte de jonction, s’assurerde ranger tous les fils et toutes les connexions dans la boîte, sans coincer aucun fil.Fig. FÉtape 9Pincer les ressorts de la garniture pour pousser la garniture dans le plafond (Fig. F).L’échelle de réglage peut être positionnée en segment de ¼ po pour s’ajuster à touteépaisseur de plafond. Pour ajuster, dégager délicatement la cale sur le ressort de lagarniture, glisser le ressort jusqu’au réglage d’échelle approprié et encliqueter en place(Fig. G). Pour les premiers cadres DEL introduits, il peut être nécessaire d’ajuster lesressorts selon la hauteur du cadre en plus de l’épaisseur du plafond.Échelle deréglageRessorts de lagarnitureÉtape 10 (Pour les cadres séries 6100 , 6200 , ou B600 seulement)Les ressorts de la garniture du kit sont à l’envers, comme à la Fig H. Ne pas ajuster lahauteur des ressorts de la garniture, car ceci peut causer l’impossibilité d’enlever lagarniture sans toutefois endommager le réflecteur par le cadre en aluminium moulé. Pourl’installation, suivre les étapes 1 à 7. Plier les ressorts vers le bas et pousser la garnituredans l’ouverture jusqu’à ce que bien en place. 2017 Philips Lighting Holding B.V. Tous droits réservés. Philips seréserve le droit de modifier les spécifications et d’abandonner toutproduit en tout temps, sans avis préalable ni obligation et déclinetoute responsabilité quant aux conséquences découlant del’utilisation de cette publication. Philips.com/luminaires11/08/2017 page 6Philips.com/luminairesFig. GFig. H

SYSTEMS. IF NOT QUALIFIED, DO NOT ATTEMPT INSTALLATION. CONTACT A QUALIFIED ELECTRICIAN. . CS700 Series . Use wire nuts to connect the black retrofit wire to the black source lead, the white retrofit wire to the white source lead, & tie the green retrofit wire, bare copper wire, and source ground wires together. Connect the new retrofit .

Related Documents:

Philips Lightolier LyteCaster LED Downlights are ideal general purpose downlighting solution, providing comfortable, quality light. Available in new construction and remodeler frame with interchangeable light engine that is offered in two lumen packages. The

DMF LIGHTING 1118 E. 223rd St. Carson, CA 90745 323.934.7779 info@dm ighting.com dmlightingom Project: Type: Product Code: Date: Spec She et V - 06.15.21 DRD2 & Classic Frames Fixed Downlighting System JA TITLE 24 . DRD2 & Classic Frames Fixed Downlighting System

The author uses chronological order to organize the information in “Chalk Mine Is Nebraska Treasure.” Explain how this organizational pattern helps the reader better understand the geological and historic value of Happy Jack Chalk Mine. Write a well-organized response using specific evidence from the passage to support your answer. 2016 C4L

mathematics, science, literacy, and social-emotional development. The curriculum uses an interdisciplinary approach to address growing concerns that the majority of preschool instructional time is devoted to literacy at the expense of other content areas, particularly mathematics and science. The C4L research team is composed

NHBC Buildmark 10 year cover Gas central heating system controlled with Hive Active Heating Intruder Alarm System Mains smoke and carbon monoxide alarms Hardwood front door and multipoint locking system †Double glazed PVCu windows and French casement doors LED downlighting to Hall, Landing, Kitchen, Utility, Bathroom

LED light engine with three snap-on tabs for ease in changing lenses HL6 ALLSLOPE replaces traditional light sources used for slope ceiling downlighting, an

Optional integral emergency controller and battery pack provides 600lm nominal output. Test switch and indicator light mounted on side of chassis on one end. Emergency battery has a 3 month pre-installed shelf life, and must be stored and installed in environments of 20C t

making formal decisions at the final “appeal” stage of our process (see page 75 for more details ) All figures relate to the financial year 2012/2013. 4 annual review 2012/2013 . Financial Ombudsman Service Financial Ombudsman Service . annual review 2012/2013 5. chairman’s foreword. Sir Nicholas Montagu . kcb. we have resolved . more cases. than in any previous year – and each of .