Fluke 712B And Fluke 714B Calibration Manual

3y ago
11 Views
2 Downloads
6.48 MB
50 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Giovanna Wyche
Transcription

712B/714BRTD/Thermocouple CalibratorCalibration ManualMarch 2015 2015 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.All product names are trademarks of their respective companies.

LIMITED WARRANTY AND LIMITATION OF LIABILITYEach Fluke product is warranted to be free from defects in material and workmanship under normal use andservice. The warranty period is three years and begins on the date of shipment. Parts, product repairs, andservices are warranted for 90 days. This warranty extends only to the original buyer or end-user customer ofa Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, inFluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormalconditions of operation or handling. Fluke warrants that software will operate substantially in accordancewith its functional specifications for 90 days and that it has been properly recorded on non-defective media.Fluke does not warrant that software will be error free or operate without interruption.Fluke authorized resellers shall extend this warranty on new and unused products to end-user customersonly but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support isavailable only if product is purchased through a Fluke authorized sales outlet or Buyer has paid theapplicable international price. Fluke reserves the right to invoice Buyer for importation costs ofrepair/replacement parts when product purchased in one country is submitted for repair in another country.Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair,or replacement of a defective product which is returned to a Fluke authorized service center within thewarranty period.To obtain warranty service, contact your nearest Fluke authorized service center to obtain returnauthorization information, then send the product to that service center, with a description of the difficulty,postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Followingwarranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Flukedetermines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormalcondition of operation or handling, including overvoltage failures caused by use outside the product’sspecified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repaircosts and obtain authorization before commencing the work. Following repair, the product will be returned tothe Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges(FOB Shipping Point).THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHERWARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLEFOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES,INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY.Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion orlimitation of incidental or consequential damages, the limitations and exclusions of this warranty may notapply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or otherdecision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any otherprovision.Fluke CorporationP.O. Box 9090Everett, WA 98206-9090U.S.A.11/99Fluke Europe B.V.P.O. Box 11865602 BD EindhovenThe Netherlands

Table of ContentsTitleIntroduction .Contact Fluke .Safety Information .Symbols.712B Specifications.DC mA Measurement .Ohms Measurement .Ohms Source.RTD Input and Output .General Specifications.714B Specifications.Thermocouple mV Input .Thermocouple mV Output .Thermocouple mA Input .Thermocouple Input and Output .General Specifications.Maintenance.Replace the Batteries .Clean the Product.Required Equipment.712B Performance Verification.Verify Ohms Source .Verify 4-Wire Ohms Measure .Verify 3-Wire Ohms Measure .Verify mA Measure.714B Performance Verification.Verify mV Source.Verify mV Measure .Verify TC Measure (Type K) .Verify TC K Source .Verify mA Measure .712B Calibration Adjustment .Enter Manual Calibration Mode .Adjust Ohms Source.Adjust 50 Ω Source.Adjust 350 Ω 818192121212222

712B/714BCalibration ManualAdjust 500 Ω Source.Adjust 3500 Ω Source.Adjust Trigger Current for Ohms Measure .Adjust 0.1 mA Trigger Current.Adjust 0.25 mA Trigger Current .Adjust 0.5 mA Trigger Current.Adjust 1 mA Trigger Current.Adjust Ohms Measure .Adjust 50 Ω Input .Adjust 350 Ω Input .Adjust 500 Ω Input .Adjust 3500 Ω Input .Adjust mA Measure .Adjust 0.1 mA Input .Adjust 24 mA Input .Adjust External Trigger for Ohms Source .Adjust 0.1 mA External Trigger .Adjust 1 mA External Trigger.Save Data and Reset the 712B System .714B Calibration Adjustment .Enter Calibration Mode.Use 8508A to Adjust the 5522A Output.Adjust mV Source.Adjust mV Measure .Adjust Internal Cold Junction Temperature .Use the Fluke 9101-256 .Use a Lag Bath.Adjust mA Measure .Save Data and Reset the 714B System .User-Replaceable Parts and Accessories 4353537383940

List of ymbols.Required Equipment for 712B Verification and Calibration Adjustment .Required Equipment for 714B Verification and Calibration Adjustment .712B Ohms Source Limits.712B 4-Wire Ohms Measure Limits .712B 3-Wire Ohms Measure Limits .712B mA Measure Limits .714B mV Source Limits.714B mV Measure Limits .714B Type K Measure Limits .714B TC K Source Limits .714B mA Measure Limits .User-Replaceable Parts and Accessories for 712B .User-Replaceable Parts and Accessories for 714B .iiiPage210101213141517171819204042

712B/714BCalibration Manualiv

List of .15.16.17.18.19.20.21.Replace the Batteries .Verify 712B Ohms Source .Verify 712B 4-Wire Ohms Measure .Verify 712B 3-Wire Ohms Measure .Verify 712B mA Measure .Verify 714B mV Source .Verify 714B mV Measure .Verify Type K Measure .Verify mA Measure.Adjust 712B Ohms Source .Adjust 712B Trigger Current.Adjust for 712B Ohms Measure .Adjust 712B mA Measure.Adjust External Trigger for Ohms Source .Connect the 714B to the 8508A .Adjust 714B mV Measure.Connect the 714B to the Fluke 9101-256 .Use Lag Bath to Adjust Cold Junction Temperature .714B and 5522A mA Channel Connections.User-Replaceable Parts and Accessories for 712B .User-Replaceable Parts and Accessories for 714B .vPage91112131516171820212426293033343637384143

712B/714BCalibration Manualvi

IntroductionThe Fluke 712B/714B RTD/Thermocouple Calibrator (the Product) is a handheld,battery-operated instrument that measures and sources a variety ofRTDs/thermocouples. It also has an isolated channel to measure 4-20 mA.Contact FlukeTo contact Fluke, call one of the following telephone numbers: Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: 31 402-675-200 Japan: 81-3-6714-3114 Singapore: 65-6799-5566 Anywhere in the world: 1-425-446-5500Or, visit Fluke's website at www.fluke.com.To register your product, visit http://register.fluke.com.To download manuals, or to view, print, or download the latest manualsupplement, visit http://us.fluke.com/usen/support/manuals.Safety InformationA Warning identifies conditions and procedures that are dangerous to the user.A Caution identifies conditions and procedures that can cause damage to theProduct or the equipment under test. WarningTo prevent possible electrical shock, fire, or personal injury: Carefully read all instructions. Read all safety information before you use the Product. Use the Product only as specified, or the protectionsupplied by the Product can be compromised. Do not use the Product around explosive gas, vapor, or indamp or wet environments. Never apply more than 30 V between any two terminals, orbetween any terminal and earth ground. Do not use the Product if it is damaged. The battery door must be closed and locked before youoperate the Product.1

712B/714BCalibration Manual Remove all probes, test leads, and accessories before thebattery door is opened. Remove the input signals before you clean the Product. Have an approved technician repair the Product. Replace the batteries when the low battery indicator showsto prevent incorrect measurements.For safe operation and maintenance of the Product: Repair the Product before use if the batteries leak. Remove the batteries if the Product is not used for anextended period of time, or if stored in temperatures thatexceed the specification of the battery manufacturer. If thebatteries are not removed, battery leakage can damage theProduct.SymbolsSymbols used on the Product or in this manual are shown in Table 1.Table 1. SymbolsSymbol Earth Ground Battery Conforms to relevant Australian Standards. Risk of danger. Important information. See Manual. Inspected and licensed by TÜV Product Services. Conforms to European Union directives.CAT IIMEASUREMENT CATEGORY II is applicable to test and measuring circuitsconnected directly to utilization points (socket outlets and similar points) of the lowvoltage MAINS installation.CAT IIIMEASUREMENT CATEGORY III is applicable to test and measuring circuitsconnected to the distribution part of the building’s low-voltage MAINS installation.CAT IVMEASUREMENT CATEGORY IV is applicable to test and measuring circuitsconnected at the source of the building’s low voltage MAINS installation. 2DescriptionConforms to relevant North American Safety Standards. Conforms to relevant South Korean EMC Standards. This Product complies with the WEEE Directive (2002/96/EC) marking requirements.The affixed label indicates that you must not discard this electrical/electronic productin domestic household waste. Product Category: With reference to the equipmenttypes in the WEEE Directive Annex I, this product is classed as category 9 "Monitoringand Control Instrumentation" product. Do not dispose of this product as unsortedmunicipal waste. Go to Fluke’s website for recycling information.

RTD/Thermocouple Calibrator712B Specifications712B SpecificationsSpecifications are based on a one year calibration cycle and apply from 18 Cto 28 C unless stated otherwise. All specifications assume a 5 minute warmupperiod.DC mA MeasurementAccuracy (% of Reading Floor)Range0-24 mAResolution0.001 mA1 Year2 Year0.01 % 2 μA0.02 % 4 μA Notes: Temperature coefficient: (0.002 % of reading 0.002 % of range) / C ( 18 C or 28 C)Ohms MeasurementRangeAccuracy (% of Reading Floor)Resolution1 Year2 Year0.00 Ω to 400.00 Ω0.01 Ω0.015 % 0.05 Ω0.03 % 0.08 Ω400.0 Ω to 4000.0 Ω0.1 Ω0.015 % 0.5 Ω0.03 % 0.8 Ω Notes:Reading accuracy is based on 4-wire input. For 3-wire ohm measurements, assuming all three leads are matched, add0.05 Ω (0.00 Ω 400.00 Ω), 0.2 Ω (400.0 Ω 4000.0 Ω) to the specifications.Temperature Coefficient: (0.002 % of reading 0.002 % of range) / C ( 18 C or 28 C)Ohms SourceOhms RangeExcitation Current fromMeasurement DeviceAccuracy(% of Output Floor)1 Year2 Year0.1 mA to 0.5 mA0.015 % 0.1 Ω0.03 % 0.2 Ω0.5 mA to 3 mA0.015 % 0.05 Ω0.03 % 0.08 Ω400.0 Ω to 1500.0 Ω0.05 mA to 0.8 mA0.015 % 0.5 Ω0.03 % 0.8 Ω1500.0 Ω to 4000.0 Ω0.05 mA to 0.4 mA0.015 % 0.5 ΩResolution0.03 % 0.8 Ω1.00 Ω to 400.00 Ω1.00 Ω to 400.00 Ω0.01 Ω400.0 Ω to 4000.0 Ω0.1 Ω Notes: Supports pulsed transmitters and PLCs with pulse times as short as 5 ms. Temperature coefficient: (0.002 % of output 0.002 % of range) / C ( 18 C or 28 C)3

712B/714BCalibration ManualRTD Input and OutputMeasure ( C)RTD Type(α)1 Year2 YearSourceCurrent1 Year2 Year10 ΩPt(385)-200 to 1001.531 mA1.53100 to 8001.83.61 mA1.83.650 ΩPt(385)-200 to 1000.40.71 mA0.40.7100 to 8000.50.81 mA0.50.8-200 to 1000.2 C0.4 C0.2 C0.4 C100 to 8000.015 % 0.18 C0.03 % 0.36 C0.015 % 0.18 C0.03 % 0.36 C200 ΩPt(385)-200 to 1000.2 C0.4 C0.2 C0.4 C100 to 6300.015 % 0.18 C0.03 % 0.36 C0.015 % 0.18 C0.03 % 0.36 C500 ΩPt(385)-200 to 1000.3 C0.6 C0.3 C0.6 C100 to 6300.015 % 0.28 C0.03 % 0.56 C0.015 % 0.28 C0.03 % 0.56 C1000 ΩPt(385)-200 to 1000.2 C0.4 C0.2 C0.4 C100 to 6300.015 % 0.18 C0.03 % 0.36 C0.015 % 0.18 C0.03 % 0.36 C100 ΩPt(3916)-200 to 1000.2 C0.4 C0.2 C0.4 C100 to 6300.015 % 0.18 C0.03 % 0.36 C0.015 % 0.18 C0.03 % 0.36 C100 ΩPt(3926)-200 to 1000.2 C0.4 C0.2 C0.4 C0.015 % 0.18 C0.03 % 0.36 C100 ΩPt(385)1 mA500 μA250 μA250 μA1 mA1 mA100 to 6300.015 % 0.18 C0.03 % 0.36 C10 ΩCu(427)-100 to 2601.531 mA1.53120 ΩNi(672)-80 to 2600.150.31 mA0.150.350 ΩCu(427)-180 to 2000.40.71 mA0.40.7100 ΩCu(427)-180 to 2000.20.41 mA0.20.4YSI40015 to 500.20.4250 μA0.20.4100 ΩPt(3902)-200 to 1000.2 C0.4 C0.2 C0.4 C100 to 5000.015 % 0.18 C0.03 % 0.36 C0.015 % 0.18 C0.03 % 0.36 C1 mA Notes:Sensor inaccuracies not included. Resolution: 0.1 C.Read accuracy is based on 4-wire input. For 3-wire RTD measurements, assuming all three RTD leads arematched, add 1.0 C (Pt10 and

Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price.

Related Documents:

FLUKE 86 367 FLUKE 88 423 FLUKE 8062A . FLUKE 8060A . FLUKE 8010A . FLUKE 8012A . FLUKE 8050A . FLUKE 37 FLUKE 45 E SCOPES 329 395 329 359 439 249 579 20 MHz SCOPE 345 Dual Trace 2 Yr Warranty-Parts & Labor SCOPE PROBES 60 MHz, X1 & X10 SPECIAL 700072 18.95 150 MHz, X10 700073 39." Duracell / Eveready 9V Alkaline Battery .

1228556 fluke 1663 / fvf au installation tester fluke 1365408 fluke 64 max ir thermometer 20:1 d:s fluke 1758013 fluke high resolution diagnostic videosc fluke 1758015 8.5mm scope with a 3m probe, dual view c fluke 2524570 c12a soft carrying case fluke 2921230 t5-100

5 Fluke Corporation Tester per batterie Fluke Serie 500 Fluke Italia S.r.l. Viale Lombardia 218 20861 Brugherio (MB) Tel: (39) 02 3600 2000 Fax: (39) 02 3600 2001 E-mail: fluke.it.cs@fluke.com Web: www.fluke.it Fluke (Switzerland) GmbH Industrial Division Hardstrasse 20 CH-8303 Bassersdorf Telefon: 044 580 75 00 Telefax: 044 580 75 01

See your Fluke distributor, or call 1- 800 -87 -FLUKE for a catalog and the name of the distributor nearest you. in the industry. Make the choice that gives you the most choices. Fluke 12 Auto -function Multimeter S95.00 FLUKE 12 FLUKE 77 FLUKE 83 The Fluke

FLUKE-117/323 EUR 4296034 Fluke Electrician’s Multimeter Combo Kit 435 FLUKE-117/PRV240 4636971 Prüfeinheit, Fluke 117 DMM Kit 437 Multimeter Serie 170 . FLK-TRUTEST-ADV 5265319 Fluke TruTest Software-Lizenzcode – Erweitert 429 FLK-TRUTEST-CD 5265337 Fluke Tru

FLUKE-289/FVF/EUR 3947812 Combinatiekit van Fluke 289 en FlukeView Forms-software 845 FLUKE-289/IMSK 3449156 Serviceset industriële multimeter 720 20 Series Multimeters C25 681114 Soepele draagtas geschikt voor Fluke 25/27/8025A 66 FLUKE-27II/EUR 3947770 Industriële Multimeter (IP67) 586 FLUKE

5 Fluke Corporation Série 500 de testeurs de batterie Fluke Fluke France S.A.S. Parc des Nations 383 rue de la belle étoile 95 700 Roissy en France - FRANCE Téléphone: 01 708 00000 Télécopie: 01 708 00001 E-mail: info@fr.fluke.nl Web: www.fluke.fr Fluke Belgium N.V. Kortrijksesteenweg 1095 B9051 Gent Belgium Tel: 32 2402 2100 Fax: 32 .

approaches to the subject of reconstruction in archaeological illustration, and other media i.e. films. Method(s) of teaching: The module comprises: A weekly practical session (2hrs) where tutor will introduce different materials and recorded graphic data to be drawn. 1 x lecture Visit and meet with archaeological illustrators and graphic designers in their workplace Method of assessment: The .