Cooper B-Line - Cable Tray Systems - Series 2, 3, 4, & 5 .

2y ago
7 Views
3 Downloads
554.85 KB
9 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Jayda Dunning
Transcription

Series 2, 3, 4, & 5 Aluminum - AccessoriesWedge Lock Splice PlatesCatalog or heavy dutyexpansion splice platessee page 381.Catalog No.TraySeries9A-10149A-10159A-10169A-1017Catalog No.H46A9A-6006H47A, 57A9A-6007Heightin.mm4567101127152178Universal Splice PlatesStep Down Splice PlatesVertical Adjustable Splice Plates Used to splice to existing cable traysystems. Furnished in pairs with hardware. These splice plates areoffered for connecting cabletray sections having side railsof different heights. Furnished in pairs withhardware. These plates provide for changes inelevation that do not conform to standardvertical fittings. Furnished in pairs with hardware. Bonding Jumper not required.Catalog No.Catalog mm4567101127152178Horizontal AdjustableSplice Plates Offered to adjust a cable trayrun for changes in directionin a horizontal plane that donot conform to standardhorizontal fittings. Furnished in pairs with hardware. New design bonding jumpersnot required. (X) Insert 4, 5, 6 or 7 forside rail -103(X)-12 or 9A-103(X)-36One pair splice plates with extensions.LLRequiressupports within24” on bothsides, perNEMA VE 2.Heightin.Series 2, 3, 4, & 5 Aluminum Expansion plates allow for one inch expansionor contraction of the cable tray, or whereexpansion joints occur in the supporting structure. Furnished in pairs with hardware. Bonding Jumpers are requiredon each siderail.Order Separately. Standard for H46A, H47A and 57Astraight sections. Six bolt design 1/2" Stainless SteelType 316 hardware standard. Available on ladder bottomsonly. 09 and 12" rungspacing. Furnished in pairswith hardware.Heightin.Expansion Splice PlatesH46A, H47A and 57A Mid-SpanSplice Standard 4-hole pattern. Furnished in pairs, with hardware. One pair including hardwareprovided with each section. Boxed in pairswith hardware. For field installationdrill 13/32" hole.mm5 to 46 to 46 to 57 to 47 to 57 to atalog 27152178Branch Pivot Connectors Branch from existing cable tray runs at any point. Pivot to any required angle. UL Classified for grounding(bonding jumper not required). Furnished in pairs with hardware.9A-103(X)Splice onlyCable TrayEnd CutTrayWidth'L'MiteredNot miteredNot miteredThru 36"Thru 12"Thru 36"N/A16"41"Green Fastest shipped itemsRequiressupportswithin 24”on bothsides, perNEMA VE 2.Catalog No.9A-20449A-20459A-20469A-2047Black Normal lead-time itemsHeightin.mm4567101127152178Red Normally long lead-time items238Cable Tray Systems

Series 2, 3, 4, & 5 Aluminum - AccessoriesCross Connector BracketTray Hardware For field connecting crossing section. Furnished in pairs with 3/8"hardware.For field installation drill 13/32" hole.Standard Tray HardwareCatalog No.SNCB 3/8" x 3/4" Znplt SquareNeck Carriage Bolt ASTM A307 Grade ACatalog No.Catalog No.SFHN 3/8"-16 ZnpltSerrated Flange Hex Nut ASTM A563Grade A9A-1240Finish: Zinc Plated ASTM B633, SC1Offset Reducing Splice PlateOptional Tray Hardware This plate is used for joining cable trays havingdifferent widths. When used in pairs they forma straight reduction; whenCatalog No.used singly with a standardsplice plate, they form an9A-1064-(‡)offset reduction. Furnished as one plate9A-1065-(‡)with hardware.9A-1066-(‡) (‡) Insert reduction9A-1067-(‡)Catalog No.SNCB 3/8" x 3/4" SS6 SquareNeck Carriage Bolt AISI 316 Stainless SteelHeightin.mm4567101127152178Catalog No.SFHN 3/8"-16 SS6 SerratedFlange Hex Nut AISI 316 Stainless SteelTo order optional 316 Stainless Steelhardware add SS6 suffix to part numberExample: 9A-1004SS6Tray to Box Splice PlatesFrame Type Box ConnectorBlind End Used to attach theend of a cable trayrun to a distributionbox or controlpanel. Furnished in pairswith hardware. Designed to attach the end of a cabletray run to a distribution cabinet orcontrol center to help reinforce the boxat the point of entry. Furnished with trayconnection hardware. (‡) Insert tray width This plate forms aclosure for a deadend cable tray. Furnished as oneplate with hardware. (‡) Insert tray widthCatalog No.Catalog No.Catalog Conduit to Cable Tray AdaptorsCatalog No.9ZN-1150-(‡)mm4567101127152178Conduit to Cable Tray Adaptor Assembly required. Conduit clamp included. (‡) Conduit size(1/2" thru 4"). Assembly required. Mounting hardwareincluded. Conduit clampsprovided. (‡) Conduit size(1/2" thru -(‡)Heightin.Catalog No. For easy attachment of conduit terminating at a cable tray. Use on aluminum or steel cable trays.9ZN-1155-(‡)Cable Tie (Ladder Tray)Nylon ties provide easy attachment ofcable to ladder rungs; maximum cableO.D. is 3" (76mm).9G-1158-1/2, 3/49G-1158-1, 11/49G-1158-11/2, 29G-1158-21/2, 39G-1158-31/2, 4Overall Length 15"Catalog No.99-2125-15Green Fastest shipped itemsBlack Normal lead-time items239Cable Tray SystemsCatalog No.Conduit Sizein.mm1/2, 3/415, 2025, 3240, 5065, 8090, 1001, 11/411/2, 221/2, 331/2, 4Red Normally long lead-time itemsAluminum I-BeamSeries 2, 3, 4, & 5 Aluminum9A-10549A-10559A-10569A-1057Heightin.

Series 2, 3, 4, & 5 Aluminum - AccessoriesLadder Drop-OutTrough Drop-Out & Drop-Out Bushing Specially-designed Ladder Drop-Outs provide a rounded surface with4" (101 mm) radius to protect cable as it exits from the cable tray,preventing damage to insulation. The drop-out will attach to anydesired rung. (‡) Insert tray width These devices provide a rounded surface to protect cable as it exitsfrom the trough-type cable tray. Hardware is included for attachment of the trough bottom drop-out. (‡) Insert tray widthCatalog No.Catalog No.9A-1104T-(‡)Catalog No.9A-1104-(‡)Trough-Type Drop-Out99-1124Snap-In Plastic BushingBarriersHorizontal BendStraight Section Horizontal Bend Barriers are flexible in orderto conform to any horizontal fitting radius.Cut to length. Order catalog number based on loadindepth. Furnished with three #10 x 1/2" zinc platedself-drilling screws and a 99-9982 BarrierStrip Splice. Standard length is 72" (6 ft.), sold individual- Standard length: 120" (3 m) 144" (12 ft.). Order catalog number based on loadingdepth. Furnished with four #10 x 1/2" plated selfdrilling screws and a 99-9982 splice.ly.HCatalogNo.Series 2, 3, 4, & 5 de RailHeightHLoadingDepth gNo.Length 144 for 12'or120 for 10'Side LoadingDepth al Bend BarriersBarrier Strip Clip Vertical Bend Barriers are preformed to conform to aspecific vertical fitting. Furnished with three #10 x 1/2" plated self-drillingscrews and a 99-9982 Barrier Strip Splice. (*) Insert 30, 45, 60 or 90 for degrees (†) Insert 12, 24, 36 or 48 for radius Zinc plated steel barrier clip fastens toeither aluminum or steel ladder rung. Furnished with one #10 x 1/2" zincplated self-drilling 76A-(*)VI(†)Outside Bend Side RailCatalog )76A-(*)VO(†)9ZN-9002Catalog No.99-9982Barrier Strip SpliceOutside Bend(VO)Inside BendCatalog No.Catalog No.Inside Bend(VI)in.mm4567101127152178Green Fastest shipped itemsLoadingDepth 'H'in.3456 Plastic splice holds adjoiningbarrier strips in straight alignment. 5” (127mm) long.mm76101127152Black Normal lead-time itemsRed Normally long lead-time items240Cable Tray Systems

Series 2, 3, 4, & 5 Aluminum - AccessoriesStainless Steel Cable Clamp "P"Bonding Jumper Fits with series 2, 3, & 4 rungs. Attaches to rung at any point. 14 gauge Type 316 stainless steelmaterial to minimize corrosion andinduction heating. Plated steel and aluminumalso available.Use at each expansion splice and where the cable tray is notmechanically/electrically continuous to ground.Sold individually. Hardware included. See table 392.7(B)(2) on page 25 foramperage ratings required to matchthe UL cross-sectional area of the tray. See tray loading chart for ULcross-sectional area. Bonding jumper is 16" long.Catalog No.Cross-Sectional Area99-N10.40 Square inches60099-401.5 Square inches160099-16202.0 Square inches2000Refer to Section CFCable FixingCatalog No.Cable Sizein.mmBP081SS.250 - .8406.4 - 21.3BP110SS.810 - 1.10020.6 - 28.0BP135SS.850 - 1.35021.6 - 34.8BP175SS1.250 - 1.75031.8 - 44.5BP205SS1.550 - 2.05039.4 - 52.1BP250SS2.000 - 2.50050.8 - 63.5BP300SS2.500 - 3.00063.5 - 76.2BP325SS2.750 - 3.25069.9 - 82.6BP375SS3.250 - 3.75082.6 - 95.3BP425SS3.750 - 4.25095.3 - 108.0BP475SS4.250 - 4.750 108.0 - 120.7Grounding ClampCooper B-Line Cable Tray is UL classified as to its suitability as anequipment grounding conductor. If a separate conductor for additionalgrounding capability is desired, Cooper B-Line offers this clamp forbolting the conductor at least once to each cable tray section. Accepts #6 AWG to250 MCM.Catalog No.Material9A-2130Tin Plated AluminumHanger Rod Clamp Mechanically attaches groundingcables to cable tray. Hardware included. (*) Insert ZN or SS4 For 1/2" ATR.Furnished in pairs.Order ATR and hex nuts separately.Two-piece "J"-hanger design.1500 lbs./pair capacity safety factor 3.(*) Insert ZN or GCatalog No. Rail Height9(*)-53249(*)-53259(*)-53269(*)-5327Cable Size9(*)-2351#1 thru 2/09(*)-23523/0 thru 250 MCMin.mm4567101127152178Threaded Rod (ATR) & Rod uplingCat. No.3/8"-16730ATR 3/8" x Length36", 72", 120", 144"B655-3/81/2"-131350ATR 1/2" x Length36", 72", 120", 144"B655-1/2All dimensions in shaded areas are millimeters unless otherwise specified.Loading based on safety factor 5.Standard Finish: Zinc platedSee B-Line Strut Systems Catalog for other sizes and finishes.Green Fastest shipped itemsBlack Normal lead-time items241Cable Tray SystemsRed Normally long lead-time itemsSeries 2, 3, 4, & 5 AluminumGround ClampCatalog No.Ampacity

Series 2, 3, 4, & 5 Aluminum - AccessoriesCable Tray Clamp/GuideIsolator Pad Features a no-twist design. Has four times the strengthof the traditional design. Each side is labeled toensure proper installation. Furnished in pairs, with orwithout hardware. Use as a friction reducer and/or asa dissimilar metal isolator barrier. UV resistant HDPE. Temperature range: -100 to 160 F. Designed to use with9(*)-1205 or 9(*)-1208 clamp/guide. Color - White.21/4"(57mm)9ZN-1208 shown.Installed as a clamp.11/2"(39mm)Patent # RE35479Note: For heavy duty or vertical applicationssee 9(*)-1241 or 9(*)-1242 page 245Catalog No.WithoutWithHardwareHardwareSeries 2, 3, 4, & 5 /221/421/421/421/421/43857575757579ZN-1204 shown.Installed as a 0G90Alum.HDGAF316SSG90Isolation pad shown aswhen used with a guide.Catalog No.Cable Tray ClampCable Tray Guide Hold-down clamps for single or double cable tray runs. No drilling of support I-beam or channel is required. Sold in pieces- two clamps are required per tray. Maximum beam flange thickness 11/8" (28.58 mm). Catalog No.9ZN-1249HD9G-1249HDIsolation pad shown with topflange doubled under forclamp application.99-PE34Expansion guide for single or double cable tray runs.Guide allows for longitudinal movement of the cable tray.No field drilling of support I-beam or channel is required.Guides are required on both sides of cabletray to prevent lateral movement - can beplaced on either the inside or outsideflange of cable tray. Guides are sold in pieces - two guides arerequired per tray. Maximum flange thickness 11/8" (28.58 mm).FinishCatalog No.FinishZnpltHDGAF9ZN-1249Znplt9G-1249HDGAFNylon PadNeoprene Roll Use for friction reduction. Hardness: Shore D80. Low friction coefficient. UV resistant.1/8" Excellent weatherability.(3mm) UL - 94HB. Use for material isolation.x 2" x 25' roll.Hardness: Shore A60.Good weatherability.1/8"6"(152mm)3"(76mm)Catalog No.Green Fastest shipped itemsCatalog No.99-PE36Black Normal lead-time items99-NP300Red Normally long lead-time items242Cable Tray Systems

Series 2, 3, 4, & 5 Aluminum - AccessoriesTrapeze Support KitCooper B-Line's trapeze kits provide the componentsrequired for a single trapeze support in onepackage. These kits are available in pregalvanized steel with zinc-plated hardware (2) 1/2" x 7/8" HexHead Cap Screwor hot dip galvanized steel with 316(2) 9ZN-1205stainless steel hardware.The SH channel provides the convenienceof pre-punched slots, which eliminate theneed for field drilling.CatalogNo.TrayWidthChannelLengthin. mmHold-DownGuide Clamp(4) 1/2" Hex Nut(2) N525WOChannel Nut(4) B202Square WasherThe illustrated hardware is sealed in aplastic bag and boxed with the channel,which is pre-cut to the appropriate lengthas shown in the chart.(1) B22 Channelcut to therequired lengthUniformLoadin. mmlbskN9P-5506-22SH(†)615216406 1600 7.119P-5509-22SH(†)922918457 1250 5.569P-5512-22SH(†)1230522559 1125 (†)24610348647003.119P-5530-22SH(†)3076240 1016 5902.629P-5536-22SH(†)3691446 1168 5102.279P-5542-22SH(†)42 1067 52 1321 4502.00 (†) Insert / for / " threaded rod hardware.3 8Designed for use with 1/2" threaded rod.Order rod separately.3 8Safety factor of 3.0 on all loads.Heavy Duty Trapeze Support KitCooper B-Line's trapeze kits provide thecomponents required for a single trapezesupport in one package. These kits areavailable in Dura-Green epoxy coated steelwith zinc-plated hardware or hot dipgalvanized steel with 316 stainless steelhardware.(2) 1/2" x 7/8" HexHead Cap ScrewCatalogNo.(2) 9ZN-1205Hold-DownGuide Clamp(4) 1/2" Hex Nut(2) N525WOChannel Nut(4) B202Square WasherThe SH channel provides the convenienceof pre-punched slots, which eliminates theneed for field drilling.(1) Channelcut to therequiredlengthThe illustrated hardware is sealed in aplastic bag and boxed with the channel,which is pre-cut to the appropriate lengthas shown in the 06-22SHA6152164061350 6.019(*)-5509-22SHA9229184571350 6.019(*)-5512-22SHA12305225591350 6.019(*)-5518-22SHA18457287111350 6.019(*)-5524-22SHA24610348641350 6.019(*)-5530-22SHA30762401016 1350 6.019(*)-5536-22SHA36914461168 1350 6.019(*)-5542-22SHA421067521321 1350 6.01Safety factor of 3.0 on all loads.In plastic bag9ZN-5500-1/212244pr. 9ZN-1205HHC Screw 1/2 x 7/8 ZNN525 WO ZNB202 ZN 1/2" sq washerHN 1/2 ZNRooftop Support Baseswith B22 ChannelCatalog No.DB10-28DB10-36DB10-42DB10-50DB10-60Designed as a superior rooftop supportfor cable tray,UV resistant and approved for mostroofing material or other flat surfaces.Can be used with any of Cooper B-Line’scable tray clamps and guides.Ultimate Load Capacity:1,000 lbs. (uniform load)9G-5500-1/212244pr. 9G-1205HHC Screw 1/2 x 7/8 SS6N525 WO SS6B202 HDG 1/2" sq washerHN 1/2 SS6Height x Width x 0.0”LEEDS credit available, base made from 100% recycled material.General Note: Consult roofing manufacturer or engineer for roof loadcapacity. The weakest point may be the insulation board beneaththe rubber membrane.Black Normal lead-time items243Cable Tray SystemsRed Normally long lead-time itemsSeries 2, 3, 4, & 5 AluminumCatalog No.Green Fastest shipped itemskN (*) Insert GRN or GDesigned for use with 1/2" threaded rod.Order rod separately.TrapezeHardwareKitTrayWidth

Series 2, 3, 4, & 5 Aluminum - AccessoriesCenter Hung Tray Support Cooper B-Line's unique Center Hung Cable TraySupport allows cable to be laid-in from bothsides. Eliminates costly cable pulling and fieldcutting of cable tray supports. Laborcosts are dramatically reduced. Required hardware and threaded rodmaterial for trapeze assemblies arereduced by 50%. Designed for use with 1/2" threadedrod. (Order rod separately) Use with all aluminum and steelcable trays through 24" width. Load capacity is 700 lbs. per support.Safety factor of 3.0.Eccentric loading is not to exceed a60% vs. 40% load differential. The maximum recommended unsupportedspan length is 144"/12 ft. (3.66 m). Hardware shown is 6", 9", 12"18"9ZN-522418", 24"30"(2) 1/2" Hex Nut(2) 1/2" x 7/8"Hex Head Cap Screws(1) 9/16" Inside diametersteel tubing welded to strut(2) 9ZN-1205Hold DownGuide ClampZN Zinc Plated(2) N525WO(1) B22 Channel cut tothe required length(1) B202Square WasherCenter Hung Support Hardware KitCatalog No.Series 2, 3, 4, & 5 AluminumIn plastic bag9ZN-520012212pr. 9ZN-1205HHC Screw 1/2 x 7/8 ZNN525 WO ZNB202 ZN 1/2" sq washerHN 1/2 ZNBracketBracketAAFinishes available: ZN GRN or HDGSafety Load Factor 2.5Finishes available: ZN GRN or HDGSafety Load Factor 2.5Catalog No.B494-12B494-18B494-24Uniform LoadCatalog No.Tray 218152 & 229305457121824305457610Green Fastest shipped itemsB494-30B494-36B494-42B494-48Black Normal lead-time itemsUniform LoadTray 22430364261076291410673036424876291410671219Red Normally long lead-time items244Cable Tray Systems

Series 2, 3, 4, & 5 Aluminum - AccessoriesCantilever BracketCantilever BracketAAFinishes available: ZN GRN HDG or SS4Safety Load Factor 2.5Finishes available: ZN GRN HDGSafety Load Factor 2.5SS4 orCatalog No. Uniform LoadTray WidthB409-12B409-18B409-24Catalog No. Uniform 152 & 229305457121824305457610Underfloor Support (U-Bolts not included)U-Bolt 442.066&91218243036152 & 2293054576107629141218243036423054576107629141067 Design load is 1500 lbs/pair.Safety Factor of 2.5 Furnished in pairs withhardware. Hole size: 9/16” (14mm)for 1/2” threaded rod.1.0501.3151.6601.9002.3752.87571/2"(178mm)AA Order properly sized U-Boltsseparately.Finish available: ZNSafety Load Factor 2.5Catalog No.Catalog No. Uniform LoadTray Width'A'lbskNin.mmin.mm8004503.552.006&912 & 18152 & 229305 & 4571221305533Heavy Duty HoldDown Bracket 12249A-12259A-12269A-1227Design load is 4000 lbs/pair.Four bolt design.Sold in pairs.3/8" cable tray attachmenthardware provided 1/2" support attachmenthardware not provided. (*) Insert ZN SS4 or SS6Catalog No.Black Normal lead-time items245Cable Tray Systemsmm 9(*)-1241Green Fastest shipped items'A'in.Heavy Duty Hold-Down BracketDesign load is 2000 lbs/pair.Two bolt design.Sold in pairs.3/8" cable tray attachment hardware provided.1/2" support attachment hardware not provided.(*) Insert ZN SS4 or SS6Catalog No.OutsideCable Tray Ht.9(*)-1242Red Normally long lead-time itemsSeries 2, 3, 4, & 5 AluminumB409UF-12B409UF-21'A'kNVertical Hanger Splice PlatesFits Pipe -24B297-30B297-36B297-42'A'Tray Widthlbs

Series 2, 3, 4, & 5 Aluminum - AccessoriesBeam ClampBeam Clamp B355 Finishes available: ZN or HDG Sold in pieces. Beam ClampFinishes available: ZN GRN HDG or SS4Sold in pieces.Design load is 1200 lbs. when used in pairs.Safety Load Factor 5.0Order HHCS andChannel Nuts separately. Finishes available: ZN GRN or HDG Sold in pieces.ADesign load when used in pairs.Safety Load Factor 5.0CatalogDesign load when used in pairs.Safety Load Factor 5.0Design Load*'A'Cat. 5127Design Load *B305 Thru B308 & B321 Series Beam ClampsMax. Flange Thick3/4"19 mm1 1/8"28.6 mmMat'l. Thickness1/4"6.3 mm3/8"9.5 mm Finish available: ZN For a maximum beamthickness of 3/4". For thicker beams, step upone flange width size.BCDETFASeries 2, 3, 4, & 5 AluminumB212-3/8B312 Anchor Strap Finishes available: ZN or HDG Setscrew included. Safety Load Factor 5.0Cat.No.B212-1/4600 lbs. 2.67 kN 1000 lbs. 4.45 kNRodSize ABCDEFDesign LoadlbsTB3053/8"-163/8"-162 5/16"7/8"1 1/8"2 1/2"11 Ga.6002.67B3063/8"-161/2"-132 7/16"7/8"1 1/8"2 1/2"7 Ga.11004.90B3071/2"-131/2"-1327/16"7/8"11/8"21/2"7 Ga.11004.90Cat. No.Flange 06.68B312-6Up to 6"B321-1B321-23/8"-161/2"-133 9/16"111/16"1 5/8"3 1/4"1/4"13005.79B312-96" - 9"1/2"-131/2"-133 9/16"111/16"1 5/8"3 1/4"1/4"14006.23B312-129" - 12"kN1/2"-13 Rod & HexNut Sold SeparatelyBeam ClampCatalogNo.B750-J4B750-J6B750-J9B750-J12For Flange Widthin.mm3"- 6"5"- 9"8"- 12"11"- 15"76.2 - 152.4127.0 - 288.6203.2 - 304.8279.4 - 381.0Wt./CFinish available: ZNDesign Load 500 lbs. (2.22 kN)Safety Load Factor 5.0Recommended torque:'J'-Hook Nut 125 In.-Lbs. (14.1 kN/m) Maximum flange thickness of 3/4" lbs kg10912413514749.456.261.266.7J-Hook & HexNut IncludedMaterial:7 Gauge (4.6)1 1/2"1 7/8"(47.6)(38.1)Beam ead Length .44453637819.924.028.635.4Green Fastest shipped itemsThreads‘TL’ Finish available: ZN Hex Nut included.Black Normal lead-time items“A’Red Normally long lead-time items246Cable Tray Systems

Cooper B-Line Cable Tray is UL classified as to its suitability as an equipment grounding conductor. If a separate conductor for additional grounding capability is desired, Cooper B-Line offers this clamp for bolting the conductor at least once to each cable tray section. Accepts #6 AWG to 250 MCM. Catalog No. Material 9A-2130 Tin Plated .

Related Documents:

Cooper Tools Master Power Cooper Wiring Devices Cooper-CAMPBELL Cooper-Crescent Cooper-GETA Cooper-H.K. Porter Cooper-LUFKIN Cooper-NICHOLSON Cooper-PLUMB Cooper-UTICA Cooper-WELLER Cooper-WISS Cooper-XCELITE Cordobond Cox Reels CRC Crews Croakies Crown CS Osborne

5. Wire Mesh Cable Tray 6. Single Rail Cable Tray (1) Ladder Cable Tray Generally used in applications with intermediate to long support spans 12 to 30 feet. Ladder cable tray is used for about 75 percent of the cable tray wiring system installations. It is the predominate cable tray

ZaslavlEnergo offers two types of cable tray, ladder cable tray and channel cable tray. Channel cable tray is available in wide range of widths, and ideal for pneumatic tubing and low-voltage or communications cables. ZaslavlEnergo also offers light weight cable tray designed with snap-on cover. zaslavlenergo.by / fiberglass cable tray 7

cable tray must be equal to or less than the allowable cable area for the tray width, as indicated in Table 3. When using solid bottom cable tray, the allowable cable area is reduced by 22%. Allowable Cable Fill Cable Tray Systems Cooper B-Line 23 Cable Tray Selection-Width and Available Loading Depth

CABLE TRAY SYSTEM Type CTP Type CTS Perforated Cable tray Solid Cable tray m m m mm Straight Tray Ordering Way : Note: CTP 50 - 300 - HG Model Side Height (mm) Width (mm) Material/Finish. CTP: Cable Tray Perforated CTS: Cable Tray Solid PG: Pre galvanized Steel HG: Hot Dip Galvanized AL: Aluminum S4: Stainless Steel 304 S6: Stainless Steel 316 .

instrumentation tray cable 10 general purpose cable 12 instrumentation tray exposed run direct burial cable 14 power tray exposed run direct burial cable 16 industrial ethernet cable 18 fieldbus technology cable 20 extremelife cable 22 flexlife cable 24 weldlife cable 26 armorfast instrumentation cable 28 flexible service cable

CABLE TRAY ‘Cable tray’ is a formed metal section for supporting cables. It not only simplifies cable & piping installation, but also enables later additions or modifications without much re-work. CABLE TRAY SYSTEM ‘Cable Tray System’ is an assembly of formed metal sections, coupled together by splice plates to

Use the English phonemic alphabet page, which you find at the beginning of good dictionaries, as a guide to pronouncing new words. Effective English Learning ELTC self-study materials Tony Lynch and Kenneth Anderson, English Language Teaching Centre, University of Edinburgh 2012 9 3. Don't forget to learn the word stress of a new word. Every English word has its own normal stress pattern. For .