Installation Superior Moisture Superior Structural Speed .

2y ago
2 Views
1 Downloads
2.64 MB
12 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Roy Essex
Transcription

Zip it tight. The Fastest Way To A Perfect Tight House. InstallationSpeed and EaseSuperior MoistureProtectionSuperiorAir ProtectionStructuralDurabilitySHEATHING & TAPEZIPsystem.com1.800.933.92201

Zip it tight. Committed to helping you build Faster and Smarter.We are dedicated to providing you with building knowledge that will help you achieve an even higher quality build. Our online educationcenter includes in-depth educational resources that help you ensure the optimal levels of comfort, performance and integrity for your builds.Visit our online education center at learn.huberwood.com.ProductsZIP System roof & wall sheathing. PAGE 4-5ZIP System R-Sheathing. PAGE 6-7ZIP System long length sheathing and wind zone panels . PAGE 8ZIP System radiant barrier. PAGE 9ZIP System flashing tape. PAGE 10ZIP System liquid flash. PAGE 11More information at ZIPsystem.com

SHEATHING & TAPEDiscover ZIP System sheathing & tape. It’s a one-of-a-kind structural roof and wallsystem with a built-in energy-efficient barrier that keeps moisture out and reduces airleakage while still allowing panels to properly dry. Plus, it goes up in just two easy steps:1. Install the panels2. Tape the seamsFewer steps result in 40% faster installation when compared to traditional housewrap and felt.The fastest way to achieve:Installation Speed and EaseZIP System sheathing is easier to install than traditional housewrap and felt, helpingsave money on labor costs and improve project cycle times.Superior Moisture ProtectionBy achieving optimal levels of permeability, ZIP System sheathing & tape protectsagainst water intrusion while still allowing the panels to properly dry.Superior Air ProtectionZIP System sheathing & tape forms a tight barrier against unwanted air leakage, for adurable building envelope that promotes energy efficiency and increases interior comfort.Structural DurabilityAll ZIP System panels are available as Structural 1* rated, so you always get the ultimatestrength that helps meet seismic and high wind zone code requirements.Plus Options that Provide:Enhanced Thermal ResistanceThe all-in-one ZIP System R-Sheathing and tape adds an insulated layer that enhancesthe building envelope and increases its total R-Value.Radiant Barrier EfficiencyOur ZIP System radiant barrier panels are the fastest way to add superior radiantprotection from extreme sun and heat to your roofs.*7/16" ZIP System sheathing panels are Struct 1 rated from the Brokenbow, OK mill only.3

SHEATHING & TAPEThree thicknesses. Two colors.It’s one panel that can do it all.ZIP System sheathing & tape is designed to streamline work on the jobsite. It’s aone-of-a-kind structural roof and wall system with a built-in energy-efficient barrier that keepsmoisture out and reduces air leakage, while still allowing panels to properly dry. Three panelthicknesses let you choose the strength and protection you need for your build. Each one isengineered for use on both roof and wall applications, meaning one panel is all you need.123Simply install ZIP System panels and tape the seams formoisture and air protection.1High quality structural sheathing panel madeof engineered wood delivers strength and durability.2Built-in vapor permeable, water-resistivebarrier enhances drainage and eliminates thehassles of house wrap and felt.3A continuous, rigid air barrier decreases unwantedair leakage for greater energy efficiency.444ZIP System tape with a specially engineered, highperformance acrylic adhesive bonds with ZIPSystem panels for a permanent protective seal.

Panels are Convenientlycolor-codedSample Combinations:Refer to detailed installation instructions at ZIPsystem.comGreen panels signify a thickness of 7/16" while red panels signify athickness of 1/2" and 5/8". All three thicknesses can be used in bothroof and wall applications, making it the perfect choice for any job.7/16" Combo Panel7/16"Roof & WallCombination1/2" or 5/8" Roof& 7/16" WallCombination1/2" or 5/8" Roofwith 1/2" or 5/8"Wall Combination1/2" and 5/8" Combo Panels7/16" ZIP System roof & wall sheathingPerformanceCategoryPanel SizePanelCountEdgeProfilePS2 SpanRating7/164' x 8'80T&T24/164' x 9'4' x 10'70607/16Extended Lengths*4' x 8' 1-1/8"4' x 9' 1-1/8"4' x 10' 1-1/8"807060T&T24/16Structural 1CodeEvaluationReportESR 1473ESR 1474VaporTransmission ofWRB Layer12-16 permASTME 96-00Procedure BAir Barrier**ASTME 2178 0.02L(s m2)@ 75 PaASTME 2357 0.2 L(s m2)@ 75 Pa* Contact your Huber Sales Professional for availability in your area.** When used with ZIP System tape.Although all projects are unique, experience has shown that 1 roll of 3 3/4" ZIP System tape is needed for approximately 7 sheets of 4' x 8' ZIP System sheathing. This should only beconsidered a general “rule of thumb” when ordering materials with the understanding that some jobs may require more or less depending on the specific project.1/2" & 5/8" ZIP System roof & wall sheathingPerformanceCategoryPanel SizePanelCountEdgeProfilePS2 SpanRating1/24' x 8'70T&T32/16Structural 155T&T,T&G*5/84' x 8'40/20Structural 1CodeEvaluationReportVaporTransmissionof WRB LayerESR 1473ESR 147412-16 permASTME 96-00Procedure BAir Barrier**ASTME 2178 0.02L(s m2)@ 75 PaASTME 2357 0.2 L(s m2)@ 75 Pa* Contact your Huber Sales Professional for availability in your area.** When used with ZIP System tape.Although all projects are unique, experience has shown that 1 roll of 3 3/4" ZIP System tape is needed for approximately 7 sheets of 4' x 8' ZIP System sheathing. This should onlybe considered a general “rule of thumb” when ordering materials with the understanding that some jobs may require more or less depending on the specific project.5

R-SHEATHINGInsulate and protectin one installation.For installation convenience and exceptional, long-term performance, the all-in-one ZIPSystem R-Sheathing panel provides a new approach to sealing and insulating the buildingenvelope. One panel delivers thermal, air and moisture resistance, while providing excellentstrength and durability. This single-piece design lets you avoid the hassles of multi-levelsystems. Just install the panels and tape the seams for a wall system that providesstructure, moisture protection, air tightness and insulation in a single installation.5-in-1 System with Layersof Innovation.1Continuous Foam InsulationProvides Higher R-Value- Increases thermal performance while eliminatingthermal bridging- Designed to meet new energy codes122Engineered Wood Provides Structureand Durability- Nailable wood base for trim and accessories- Provides security against easy home intrusionBuilt-In Water Resistive Barrier EliminatesHousewrap and Felt33- Eliminates costly rework- Instant rough dry-in with 180-day exposure guarantee- Superior drainage efficiency that channels moisturedownward off the panel face- Permeable overlay promotes panel drying4Continuous Air Barrier CreatesGreater Energy Efficiency455- Decreases unwanted air leakage into and outof a building- Helps protect the R-Value of insulation, reducingheating and cooling costsZIP System Tape Permanently SealsAll Panel Seams- Acrylic formulation provides superior adhesion- Rigorously tested for long-lasting performance- Easily applied with tape gun and accessories6

1" & 1 1/2" ZIP System untR-ValueEdgeProfileR-31"4' x 8'323.6T&TR-61-1/2"4' x ofBarrierWRB LayerESR 3373ASTM E 2357 0.2 L (s m2)@ 75 PaPhysical Property Data ChartZIP System Properties R-3 (1") R-6 (1-1/2")TECO Rated OSB7/16"7/16"Foam1/2"1"R-Value3.66.6Pieces Per Package32 (4'x8' sheet)31 (4'x8' sheet)Square Feet Per Package1024992PropertyTest MethodTypical ResultsDimensional StabilityASTM D 2126 2%ZIP System R-Sheathing isa code-recognized structuralbracing panel capable of resistingtransverse and lateral loading.These design values are recognizedby the ICC-ES and published inESR-3373. View the full reportonline at www.icc-es.org.Foam PerformanceCompressive StrengthASTM D 162120 psiWater AbsorptionASTM C 209 1%ASTM D 2842 3.5%Water Vapor TransmissionASTM E 96 1.0 permDensityASTM D 1622Nominal 2.0 pcfFlame SpreadASTM E 8440-60Smoke DevelopedASTM E 8450-170Tensile StrengthASTM D 1623 730 psfService Temperature-40 – 200 FZIP System PerformanceWater Resistance of CoatingsASTM D 2247-97Passed 14-dayexposure testDrainage EfficiencyASTM E 2273 90%Water Vapor TransmissionASTM E 96B12-16 perms (overlay)Water PenetrationASTM E 331-00PassedAir Barrier AssemblyASTM E 2357-05at 75Pa0.037 L/(s m2)Wind Driven RainTAS-100Passed 100 mphAccelerated WeatheringASTM G 154PassedLong term thermal resistance values of the foam were determined in accordance with ASTM C 1289-02.The R-Value of 0.55 for 7/16" OSB was obtained from ASHRAE Handbook, Fundamentals.7

SHEATHING & TAPETaller, Tougherand Fewer seams.Get all the benefits of long length wall sheathing along with the superior moistureprotection and air barrier that only ZIP System sheathing provides. Only ZIP System long length sheathing and wind zone panels combine the benefits of a longer panelwith the ability to completely eliminate housewrap.ZIP System wind zone panelsare 1-1/8" taller,accommodating roofuplift in single-storyprojects withoutrequiring additionalpaneling above.ZIP System long lengthsheathing isideal for singleand multi-storyprojects.A perfectfit for everyproject.4' x 9'4' x 10'4' x 9' 1-1/8"4' x 10' 1-1/8"See How ZIP System Long Length sheathing and wind zone panels stack up. OtherZIP System ZIP System long length panelslong length panelswind zone panelsXXXXXXXXXXXXXXXEliminate need for housewrap with built-in vapor permeablewater-resistive barrierXXContinuous rigid air barrier decreases unwanted air leakage for greaterenergy efficiencyXXBacked by 30-year system warrantyXX40% faster installation when compared to other long length systemsusing housewrapXXLong length panel, water-resistive barrier, air barrier and seam sealer are anengineered system from the same manufacturerXXStructural 1 rating for 7/16", 1/2" and 5/8" sizes**XXMore efficient panel installationCan eliminate blocking at horizontal panel seamsFewer horizontal seamsLess panel cutting and wasteCan be designed to resist combined uplift and shear** See the American Wood Council, Special Design Provisions for Wind and Seismic, AWC SDPWS-08** 1/2" and 5/8" panels available by special order.ZIP System long length sheathing and wind zone tLong Length7/164' x 9'4' x 10'7060EdgeProfileT&TWind Zone87/164' x 9' 1-1/8"4' x 10' 1-1/8"7060PS2 SpanRating24/16Structural 1CodeEvaluation ReportESR 1473ESR 1474Vapor Transmission ofWRB Layer12-16 permASTM E 96-00Procedure BAir BarrierASTME 2178-03 0.02L(s m2)@ 75 PaASTME 2357-05 0.2 L(s m2)@ 75 Pa

Can take a Scorching.And a Drenching.ZIP System radiant barrier roof panels are the fastest way to beat heat and moisture.These easy-to-install, all-in-one structural panels feature a built-in water resistive layeralong with a new radiant barrier.ZIP up a cooler home.97%Decreases attic temperatures up to 30%Reduces home cooling costs up to 12%Reduces radiant heat transfer as much as*A faster, stronger radiant barrier solution.OtherZIP System radiant barrier panelsradiant barrier panelsReduces heat load on attic mounted A/C systemsXXLess heat transfer to the living spaceXXEnergy usage is reducedXXFaster installation when compared to other radiant barrier systems using roofing feltXEliminates the need for felt with a built-in vapor permeable water-resistive barrierXDurability reduces re-work and long term performanceXBacked by a 30-year system warrantyX7/16", 1/2" & 5/8" ZIP System roof geProfilePS2 SpanRating7/164' x 8'80T&T24/16Structural 11/24' x 8'70T&T32/16Structural 15/84' x 8'55T&T,T&G**40/20Structural 1CodeEvaluationReportESR 1473ESR 1474VaporVaporTransmissionTransmissionofofWRB LayerWRB Layer12-16 permASTME 96-00Procedure BAir***Barrier**BarrierASTME 2178 0.02L(s m 2)@ 75 PaASTME 2357 0.2 L(s m2)@ 75 PaThe Florida Solar Energy Center/University of Central Florida Publication #FSEC EN-15-87 titled “Radiant Barriers: A Question & Answer Primer.” Studies represent cases in theSoutheast and may not be representative of other regions. Savings also depend on the amount of heat the roof and attic contribute to a homes cooling load.** Contact your Huber Sales Professional for availability in your area.*** When used with ZIP System tape.Although all projects are unique, experience has shown that 1 roll of 3 3/4" ZIP System tape is needed for approximately 7 sheets of 4' x 8' ZIP System sheathing. This should only beconsidered a general “rule of thumb” when ordering materials with the understanding that some jobs may require more or less depending on the specific project.9

FLASHING TAPEOutstanding adhesion,resilience and efficiency.ZIP System flashing tape is made of an advanced acrylic adhesive, proven to delivera superior airtight and watertight seal that withstands many years of harsh weather.It installs quickly by hand or by using the ZIP System tape gun, and is ideal for bothseam sealing and flashing applications.Every layer works together fortotal performance and protection.12341Slip ResistantTop layer provides good tack during installation for safety2Weather and UV ProtectionThick inner layer offers dimensional stability- Carbon black – for “sunscreen” that protects other layers- Antioxidants for durability- Warranted for up to 180 days of extreme weather and UV exposure3Long-Term DurabilityBonding layer specially formulated to bond with the adhesive for durability4All Weather Adhesion- Best performing tape in all weather conditions- Advanced acrylic adhesive delivers a lifetime of superior adhesion- Resists heat and UV light and creates permanent bond strengthSuperior adhesion at broad temperature range.Greater temperaturerange than asphalt andbutyl – withstands extremeheat and UV light.HEATUV LIGHTBetter wetting forgreater adhesionto surfaces.Adhesive flowsinto crevicesfor a tighter bond.ZIP System flashing RangeAllowableUVExposureTensile StrengthElongation90'12 milsAcrylicESR 222720 – 120 F180 Days938 psi400%-800%3-3/4"6"10

LIQUID FLASHULTIMATE VERSATILITY FORSEALING EVERY ROUGH OPENING.ZIP System liquid flash is a liquid-applied flashing membrane made of STPE(silyl-terminated-polyether) technology. This high-performance formulation combinesthe durability of silicones with the toughness of urethanes.Engineered for sealing irregular,curved or hard to flash areas.12341Optimal ViscosityFlows easily to seal irregular shapes and surfaces2Quick Cure TimeImmediately weather resistant and tack free in as little as 20–40 minutesdepending on conditions. Target thickness achieved when substrate isno longer visible3Weather and UV ResistantWarranted for up to 180 days of extreme weather and UV exposure4Proper Adhesion to a Wide Range of SurfacesBonds to wood, concrete, masonry, architectural metals, glass, PVC,FRP, EPDM and most other building materialsForms an instant seal, under the most demanding conditions.Flows easily to sealdifficult areas, suchas rough openingsand wall penetrations.Bonds and cures inwet weather and ondamp substrates.Becomes waterproofimmediately afterinstallation, providingfast rough dry-in.ZIP System liquid flashPackaging OptionsTypical Coverage:Window Sill Flashing(2x4 Framing)20 oz. Sausage Pack20 If (approx. six 3'0"window sills)29 oz. Cartridge29 If (approx. nine 3'0"window sills)CuredThicknessCompoundTechnology12 milsSTPEPolymerWater and AirPenetrationASTM E331:PassASTM xposureTack Free TimeCure Time35 –110 F180 Days20-40 Minutes*1/8" Thickness 24 Hours** At 70 F and 50% relative humidity. Low temperatures and low relative humidity slow dry time; high temperatures and high relative humidity accelerate dry time.11

SHEATHING & TAPEZIP up your next project, and starttaking advantage of the fastest wayto the perfect tight House.Visit ZIPsystem.com or call 1.800.933.9220 for details.Installation Speedand EaseSuperior MoistureProtectionSuperiorAir ProtectionStructuralDurabilityRebates &Incentives:One more way itpays to switch.We make it even easier to switchto ZIP System sheathing onyour next project. Ask aboutreceiving special first-timediscounts on your order.The ZIP System product line isbacked with an industry-leading30-year limited warranty.**Limitations and restrictions apply.Visit ZIPsystem.com for details.ZIP System tape2009 IRC & IBCCode RecognizedESR-2227To locate a dealer call 1.800.933.9220 or visit ZIPsystem.com Huber Engineered Woods LLC. ZIP System, the accompanying ZIP System and AdvanTech flooring logos and design are trademarksof Huber Engineered Woods LLC. Huber is a registered trademark of J. M. Huber Corporation. Huber Engineered Woods products arecovered by various patents. See zipsystem.com/patents for details. HUB 3177 01/14

taller, tougher and Fewer seams. Get all the benefits of long length wall sheathing along with the superior moisture protection and air barrier that only ZIP System sheathing provides. Only ZIP System long length sheathing and wind zone panels combine the benefits of a longer

Related Documents:

Moisture Encounter Plus User Guide TRAMEX MOISTURE/HUMIDITY INSTRUMENTS SURVEY ENCOUNTER The intelligent moisture meter. “State of the art” non-destructive moisture meter for measuring and recording moisture in building materials. MOISTURE ENCOUNTER PLUS. Non-destructive mois

Moisture Encounter Plus User Guide TRAMEX MOISTURE/HUMIDITY INSTRUMENTS SURVEY ENCOUNTER: The intelligent moisture meter. “State of the art” non-destructive moisture meter for measurement and data logging of moisture in building materials. CONCRETE ENCOUNTER CME 4 Non-destruc

TRAMEX MOISTURE/HUMIDITY INSTRUMENTS SURVEY ENCOUNTER: The intelligent moisture meter. "State of the art" non-destructive moisture meter for measurement and data logging of moisture in building materials. MOISTURE ENCOUNTER PLUS General purpose non-destructive moisture meter employing advance

Moisture Testing for Wood Flooring and Wood Subfloors Hand-held electrical tools, called moisture meters, should be part of the toolbox of every flooring contractor, for measuring moisture in subfloors and floors. Moisture meters have many purposes. They can determine if floor boards are dry enough for an installation to proceed.

Soil Moisture Local-scale soil moisture ( 1 km) - Synthetic Aperture Radar (SAR) - Still in an experimental stage, no operational products - All satellite SAR systems are multi-purpose missions, i.e. not well suited for the task of soil moisture monitoring Large-scale soil moisture ( 10 km): 2005-2015 Decade of Soil Moisture Remote Sensing

necessary. As defined by NWFA, moisture readings must not exceed 4.5% with a moisture meter for concrete (Tramex Moisture Encounter). In the presence of moisture, perform a calcium chloride test. The moisture level measured using the calcium c

Moisture readings must not exceed 4.5% with a moisture meter for concrete (Tramex Moisture Encounter) as defined by NWFA (National Wood FlooringAssociation). In the presence of moisture, perform a calcium chloride test. The moisture level measured using the calcium ch

DensShield Tile Backer is an ideal tile backer board for high moisture areas because it has a built-in moisture barrier that stops moisture at the surface. This special coating helps protect the tile installation and wall cavity from moisture intrusion. The built-in moisture barrier also