FTR-K1 SERIESPOWER RELAY1 POLE - 3A/5A Slim Type RelayFTR-F3 Seriesn FEATURESHigh density mountingSlim type with 7mm width and 142mm2 mounting spacel High insulationInsulation distance: minimum 6mm between coil and contact(conforms to IEC 60065)Dielectric strength: 4KVSurge strength: 10KVl Cadmium free contact for eco-programl Safety standardsUL, CSA, VDE, SEMKO, CQCl Plastic sealed relay, RTIIIl RoHS compliantPlease see page 6 for more informationlPARTNUMBER INFORMATIONn[Example](a)FTR-F3(a)A(b)Relay type(b)Contact configuration(c)Coil type (power)A(c)012(d)E - HA(e)(f)FTR-F3 :FTR-F3-SeriesA: 1 form A (SPST-NO)A: 200mW(d)Coil rated voltage012: 5.24 VDCCoil rating table at page 3(e)Contact materialE: AgNi(f)Contact ratingNilHAKS: 3A type: 5A type sealing confirmed: 3A type sealing confirmedActual marking does not carry the type name : "FTR"E.g.: Ordering code: FTR-F3AA012E-HAActual marking: F3AA012E5A 250V 5A 30VDC marked on relay1

FTR-F3SERIESFTR-K1SERIESn SPECIFICATIONItemFTR-F3FTR-F3AA( )EContact DataLifeCoil DataTiming DataInsulationConfiguration1 form A (SPST-NO)ConstructionSingleMaterialAgNiResistance (initial)Max. 100mOhm at 1A, 6VDCContact rating (resistive)3A, 125VAC, 30VDCMax. carrying current5AMax. switching voltage277VAC, 30VDCMax. switching power750VA, 90WMin. switching load *10 mA, 5VDCMechanicalMin. 5 x 106 operationsElectrical (at rated load)Min. 200 x 103 operationsRated power (20 C)200mWOperate power113mWOperating temperature range-40 C to 70 C (no frost)Operate (at nominal voltage)Max. 10ms (without bounce, no diode)Release (at nominal voltage)Max. 10ms (without bounce, no diode)Resistance (initial)Min. 1,000MOhm at 500VDCDielectric strengthSurge strengthOpen contacts750VAC (50/60Hz) 1minContacts to coil4,000VAC (50/60Hz) 1minContacts to coil10,000V / 1.2 x 50µs standard waveClearanceOtherVibration resistanceShock5A, 250VAC, 30VDC1,250VA, 150WMin. 100 x 103 operations6mmCreepageEN61810-1, VDE0435FTR-F3AA( )E-HA6mmVoltage250VPollutiondegree2Material groupIIIMisoperation10 to 55Hz double amplitude 1.5mmEndurance10 to 55Hz double amplitude 1.5mmMisoperationMin. 100m/s2 (11 1ms)EnduranceMin. 1,000m/s2 (6 1ms)WeightApproximately 4gSealingPlastic sealed RTIII* Minimum switching loads mentioned above are reference values. Please perform the confirmation test with actual load before production sincereference values may vary according to switching frequencies, environmental conditions and expected reliability levels.2

FTR-K1SERIESFTR-F3SERIESn COIL RATING200mW typeCoilCodeRated CoilVoltage(VDC)Coil Resistance /- 10%(Ohm)Must OperateVoltage(VDC) *Must ReleaseVoltage(VDC) *Max. Coil 024242,880182.457.6Rated Power(mW)200Note: All values in the tables are valid for 20 C and zero contact current.* Specified operate values are valid for pulse wave voltage.nSAFETY STANDARDSTypeComplianceContact ratingFTR-F3FTR-F3-HAULUL 508Flammability: UL 94-V0 (plastics)CSAC22.2 No. 14LR 403043A, 30 VDC/ 277 VAC (resistive)1/10 HP, 250VAC /125VAC1/8 HP, 277VACPilot duty: D3005A, 30 VDC/ 277 VAC (resistive)1/10 HP, 250VAC /125VAC1/8 HP, 277VACPilot duty: D300VDE0435400150243A, 250 VAC, cosφ 1, 200 x 103,85ºC3A, 30 VDC, Ʈ 0msec, 200 x 103,85ºC4A, 250VAC, cut off 1A, cosφ 0.8,200 x 103, 70ºC5A, 250 VAC, cosφ 1, 100 x 103,85ºC5A, 30 VDC, Ʈ 0msec, 100 x 103,85ºC4A, 250VAC, cut off 1A, cosφ 0.8,100 x 103, 70ºCSEMKOEN 61058-1: 1992 A1:1993EN 61095:1993 A115A, 250 VAC40T703

FTR-K1SERIESFTR-F3SERIESnCHARACTERISTIC DATAn REFERENCE DATA4

FTR-K1SERIESFTR-F3SERIESn DIMENSIONSStandard typel Dimensionsl Schematics(BOTTOM VIEW)l PC board mountinghole layout(BOTTOM VIEW)Unit: mm5

FTR-K1SERIESFTR-F3SERIESRoHS Compliance and Lead Free Information1. General InformationllllAll signal and power relays produced by Fujitsu Components are compliant with RoHS directive 2002/95EC includingamendments.Cadmium as used in electrical contacts is exempted from the RoHS directives on October 21st, 2005.(Amendment to Directive 2002/95/EC)All of our signal and power relays are lead-free. Please refer to Lead-Free Status Info for older date codesat: ays/lead-free-letter.pdfLead free solder plating on relay terminals is Sn-3.0Ag-0.5Cu, unless otherwise specified.This material has been verified to be compatible with PbSn assembly process.2. Recommended Lead Free Solder ProfilelRecommended solder Sn-3.0Ag-0.5Cu.Flow Solder condition:Pre-heating:Soldering:maximum 120 Cdip within 5 sec. at260 C solder bathSolder by Soldering Iron:Soldering IronTemperature:Duration:maximum 360 Cmaximum 3 sec.We highly recommend that you confirm your actual solder conditions3. Moisture SensitivitylMoisture Sensitivity Level standard is not applicable to electromechanical relays, unless otherwise indicated.4. Tin WhiskerslDipped SnAgCu solder is known as presenting a low risk to tin whisker development. No considerable lengthwhisker was found by our in house test.6

FTR-K1SERIESFTR-F3SERIESFujitsu Components International Headquarter OfficesJapanFujitsu Component LimitedGotanda-Chuo Building3-5, Higashigotanda 2-chome, Shinagawa-kuTokyo 141, JapanTel: (81-3) 5449-7010Fax: (81-3) 5449-2626Email: promothq@ft.ed.fujitsu.comWeb: www.fcl.fujitsu.comEuropeFujitsu Components Europe B.V.Diamantlaan 252132 WV HoofddorpNetherlandsTel: (31-23) 5560910Fax: (31-23) 5560950Email: info@fceu.fujitsu.comWeb: emea.fujitsu.com/components/North and South AmericaFujitsu Components America, Inc.250 E. Caribbean DriveSunnyvale, CA 94089 U.S.A.Tel: (1-408) 745-4900Fax: (1-408) 745-4970Email: components@us.fujitsu.comWeb: http://us.fujitsu.com/componentsAsia PacificFujitsu Components Asia Ltd.102E Pasir Panjang Road#01-01 Citilink Warehouse ComplexSingapore 118529Tel: (65) 6375-8560Fax: (65) 6273-3021Email: fcal@fcal.fujitsu.comWeb: s/ 2012 Fujitsu Components Europe B.V. All rights reserved. All trademarks or registered trademarks are the property of their respective owners.The contents, data and information in this datasheet are provided by Fujitsu Component Ltd. as a service only to its user and only for generalinformation purposes.The use of the contents, data and information provided in this datasheet is at the users’ own risk.Fujitsu has assembled this datasheet with care and will endeavor to keep the contents, data and information correct, accurate, comprehensive,complete and up to date.Fujitsu Components Europe B.V. and affiliated companies do however not accept any responsibility or liability on their behalf, nor on behalf of itsemployees, for any loss or damage, direct, indirect or consequential, with respect to this datasheet, its contents, data, and information and relatedgraphics and the correctness, reliability, accuracy, comprehensiveness, usefulness, availability and completeness thereof.Nor do Fujitsu Components Europe B.V. and affiliated companies accept on their behalf, nor on behalf of its employees, any responsibility or liabilityfor any representation or warrant of any kind, express or implied, including warranties of any kind for merchantability or fitness for particular use,with respect to these datasheets, its contents, data, information and related graphics and the correctness, reliability, accuracy, comprehensiveness,usefulness, availability and completeness thereof. Rev. April 26, 20127

Plastic sealed relay, RTIII. l. RoHS compliant . Please see page 6 for more information. Actual marking does not carry the type name : "FTR" E.g.: Ordering code: FTR-F3AA012E-HA Actual marking: F3AA012E 5A 250V 5A 30VDC marked on relay. POWER RELAY. 1 POLE - 3A/5A. Slim Type Relay. FTR-F3 Series. n . PARTNUMBER INFORMATION

Related Documents:

Nissan Micra - OWM 4734 Nissan Micra - OWM 4734 CPU E6 H33750 1 Battery 2 Ignition switch 3 Fusible link holder 4 Fuse box 5 Fuse and relay box a) accessory relay b) blower motor relay 6 Intelligent power distribution module a) starter relay b) cooling fan hi relay c) cooling fan lo relay d) fuel pump relay e) ignition relay f) ECM relay

38 - Check voltage output to fuel pump @ relay set 39 - Check voltage input to relay set from ignition switch 40 - Check voltage input to fuel pump relay of relay set 41 - Check input voltage to control relay of relay set 42 - Check input voltage to control relay of relay set (continued)

Power MOSFET Relay Specifications (G6D Relay) The following specifications apply to G6D Relays mounted in a G70D Relay Terminal and not the G6D Relay itself. Coil Ratings (per G6D Relay) Note: 1. The must-operate voltage is 75% or less of the rated voltage if the relay is mounted upside down. 2. Rated current and coil resistance were measured .

Results are provided for actual relay testing. Part I: Distance Relay Tests (Texas A&M University) Distance relay testing can evaluate relay performance, calibrate relay settings, and identify system conditions that could cause unexpected relay operation. Developing a relay testing methodology requires consideration of how to model the power .

Cost Transparency Storage Storage Average Cost The cost per storage Cost Transparency Storage Storage Average Cost per GB The cost per GB of storage Cost Transparency Storage Storage Devices Count The quantity of storage devices Cost Transparency Storage Storage Tier Designates the level of the storage, such as for a level of service. Apptio .

Relay data and relay setting management Management of relay versions and models World‘s largest library with relay setting data models Library expandable by customer & via relay setting model generator Result import from different test device software: Omicron, Doble, Programma, etc.

Relay AE RLY-538 5 v 178 ohm Resistor DPDT 270 ohms ½ watt Control Tortoise with 5 volt Relay-12 volts DC 12 volts DC Relay On Off To Tortoise Relay “stick” contacts “On” Button powers relay, “stick” contact holds it on “Off” button bypasses relay coil so it drops out Can have any no. of

used when setting windows hooks . Relies on the user api hook . User Api Hook Special hooking mechanism introduced to support Windows themes RegisterUserApiHook Can only be registered by privileged processes Requires the TCB privilege Caller must be running as SYSTEM Allows Windows to load a theme client module into every GUI application . Smashing the Atom . Theme Subsystem Introduced in .