YORK AMICHI SERIESAIR-COOLED DC INVERTER SCROLLCHILLERS AND HEAT PUMPSEfficiency-optimized Heating and Cooling for Best-in-class Performance

EC FansBrazed PlateHeat ExchangerCondenser CoilsSuctionAccumulatorOptiview LTController(Verasys Compatible)DC Inverter ScrollFixed-speed Scrolls

YORK AMICHI SERIES AIR-COOLED DC INVERTERSCROLL CHILLERS AND HEAT PUMPS44-254kWExceeding Efficiency StandardsThe YORK Amichi Series Air-cooled DC Inverter Scroll Chiller and Heat Pump have been designed to meet tomorrow’s efficiencystandards today. Delivering performance beyond typical chiller and heat pump efficiency levels, the YORK Amichi Seriesmeets or exceeds stringent regulatory requirements (see chart, below) through an optimized combination of YORK efficiencyenhancing technologies. Direct current (DC) inverter technology provides variable High efficiency brazed plate heat exchanger uses lesscapacity control and allows Amichi Series chiller compressorsto operate more efficiently across all cooling-load and ambienttemperature conditions versus constant-speed chillers that usea step unloading design.refrigerant and transfers heat from the liquid to refrigerantmore efficiently, providing excellent heat transfer performancein a compact size. This also results in a lower water sidepressure drop, allowing the use of smaller pumps and furtherminimizing building power consumption. Electronically commutated (EC) fans use more efficientmotors and better aerodynamics to improve overall systemefficiency and sound performance, particularly at part-load.At reduced ambient temperatures, the head pressure controlvaries fan speeds to optimize the system efficiency andensure reliable operation. This combination of variable speedcompressor and fans provides a displacement power factor ashigh as 0.93, lowering electricity costs.ECODESIGN REGULATIONS CATEGORY: Tandem compressor design uses several circuits, whichEFFICIENCY METRIC:improves off-design and part-load efficiency by using theentire surface area of the heat exchanger at all conditionswhile also providing partial redundancy.TOMORROW’S STANDARDS MET TODAY:Comfort HeatingSCOP/ƞshAmichi Heat Pump: Sept. 2017 Compliant (Tier 2)Comfort CoolingSEER/ƞscAmichi Chiller: Jan. 2021 Compliant (Tier 2)Process Cooling (Med. Temp.)SEPRAmichi Chiller: July 2018 Compliant (Tier 2)Process Cooling (High Temp.)SEPRAmichi Chiller: Jan. 2021 Compliant (Tier 2)

Performance Without CompromiseThe YORK Amichi Series is a no-compromise solution fora variety of climates and locations. Built specifically to deliverbetter performance through a wider operating envelope, theAmichi chiller and heat pump can maintain efficiency in avariety of conditions without kits or add-ons – down to animpressive -18 C ambient in cooling mode and -15 C ambientin heating mode.With the smallest footprint across the widest capacity rangeon the market, the YORK Amichi Series is also the perfectsolution for high performance in smaller spaces. Installation issimplified with a compact size that permits forklift loading, anda modular configuration allows units to be arranged in varyingfootprints to fit different space requirements. This uniquemodularity means capacity can be increased incrementallyas buildings are being constructed or spaces are becomingoccupied. And if maintenance is required, other modules in thesystem will continue to operate, helping to reduce downtimeand loss of capacity.We want to ensure our neighbors are comfortable too, evenin retrofits. That’s why our systems offer two levels of soundperformance. If requirements call for sound attenuation beyondour standard low-noise levels, an optional Ultra Quiet Kit canfurther reduce sound power by an impressive 6 dBA, providingone of the quietest units available.

YORK AMICHI SERIES AIR-COOLED DC INVERTERSCROLL CHILLERS AND HEAT PUMPS44-254kWAdvanced Control Made EasyComfort, productivity and up to half of the energy used inyour building – these are all factors affected by how yourchiller operates and how it interacts with other components inyour HVAC&R system. To help maximize efficiency and keepyou in control, the YORK Amichi Series comes standardwith integrated Smart Equipment. This technology allows theequipment to connect seamlessly to building controls like ourworld-class Verasys system, where smart-enabled equipmentcan self-identify and interoperate.Verasys provides a truly plug-and-play experience, with noprogramming or commissioning tools required. Remote accessover a secure internet connection and alarm notifications viaemail or text are possible through Verasys . The user-friendlygraphical interface provides easy access to critical equipmentand facility information to help minimize the risk of unplanneddowntime and costly repairs. Verasys also provides enhancedenergy efficiency control, allowing a facility owner to potentiallymove from an average Class D efficiency classification to aClass A efficiency classification according to the EN 15232standard. The key to this efficiency is demand control,where Verasys routes the energy requirements of a room orspace to the heating and cooling equipment – matching thedemand-side and the supply-side to provide greater overallenergy efficiency.In addition to Smart Equipment capabilities, the YORK Amichi Series provides added flexibility with standard BACnet MS/TP,Modbus RTU or N2 connectivity for communication with virtuallyany building management system. This advanced, embeddedcontrol capability also allows multiple chillers and/or heat pumpsto be connected and monitored through a single controller. Eachunit comes equipped with a touch-screen display featuring aneasy-to-use, web-style interface and intuitive navigation foreasy access to operational data. Information can be displayed inmultiple languages, and setup is very easy.PLUG & PLAY EXPERIENCERemote Accessvia InternetVerasys SmartBuilding HubSmart Air Handling UnitSmart Chiller/Heat PumpVerasys ZoneControllerSmart Fan Coil UnitRoom Module

A History of ReliabilityWhen your reputation is at stake, count on efficient, reliablecooling and heating solutions from YORK to lower costs andmaximize uptime with dependability you can count-on. Ourlocally based stocking allows quick shipment to Europeanlocations. And with our units shipping as a complete package,everything arrives at the same time. We also offer a varietyof standardized, locally stocked parts to ensure our systemscontinue to provide maximum uptime in every installation.With the YORK Amichi Series Air-cooled Scroll Chiller andHeat Pump, we’re building on our legacy of cooling solutionsand technology leadership. We don’t judge success basedon theoretical findings, but real-world experience. Our firstgeneration modular chiller was built over a decade ago. We useDC inverter technology proven in over three decades of use.Our use of inverter scroll technology dates to 1985. And everynew YORK chiller is subjected to a Highly Accelerated Life Test(HALT) during the design product development stages, allowingus to simulate a variety of extreme conditions and ensuring longterm operational reliability and quality. But our pursuit of qualitydoesn’t stop there. Decades of extensive air-cooled expertise is backed by Intelligent defrost optimizes the sequencing of the defrostproven components used in installations across the globe andin a variety of conditions. Tandem compressor management improves overallreliability by balancing system operation time betweeneach compressor.cycle and allows the remaining modules in the system tocontinue to provide heat, reducing interruptions. Compliance and certifications include EcoDesign2021 regulatory compliance, Eurovent certification andCE/PED certification. Smart logic controller coordinates and optimizes unitsfor off-design and part-load operation.The YORK Amichi Series is a no-compromise solution that delivers industry-leading efficiency,unmatched flexibility, world-class sound performance, extensive control capability and long-lastingreliability. These highly optimized designs use advanced components and innovative thinking to providethe best-in-class performance only the world-leader in chiller solutions could deliver.

YORK AMICHI SERIES AIR-COOLED DC INVERTERSCROLL CHILLERS AND HEAT PUMPS44-254kW

Base ModelAll dimensions in millimeters.All dimensions in millimeters.Amichi Series 0045, 0065Amichi Series 0080, 0100, 0130

YORK AMICHI SERIES AIR-COOLED DC INVERTERSCROLL CHILLERS AND HEAT PUMPS44-254kWBase ModelAll dimensions in millimeters.All dimensions in millimeters.Amichi Series 0160, 0200Amichi Series 0230, 0260

Amichi Series Chiller and Heat PumpModel0045 0065 0080 0100 0130 0160 0200 0230 0260Cooling capacity c/o Cooling capacity h/p unitskW44607899122159188221254Heating capacity h/p d power level STD / 88/8388/83Refrigerant circuits#112223344Refrigerant (R410A) 234Compressor typeCompressorDC scroll inverter scrollCapacity steps%Quantity#2233Stepless (inverter)#1122Fan motor typeAir side heatexchangerFans quantityEC motorWorking ambient temp. cooling mode-15 25 CTypeWater side heatexchangerPlate heat exchangerl9Pump type10111415Fixed / Variable Speed Drive PumpNominal water flowl/s2.12.93.74.7Pressure dropkPa32252730Working range water leaving temp. cooling27Variable Speed Drive Pump5.87.49.110.511.9362532413822352316-8 20 CWorking range water leaving temp. heatingDimensions &weight2-18 48 CWorking ambient temp. heat. modeUnit water volume (w/o pump kit)425 55 CHeight (w/o pump kit)mm24402500Width (w/o pump kit)mm12003050Depth (w/o pump kit)mmOperating weight (w/o pump kit)kg15005752240598875901979Chiller:Cooling only units models.Heat Pump:Air to water heat pump models.Nominal conditions:Cooling capacities in kW given for 7 C water leaving temperature t 5 C and 35 C ambient temperature.Heating capacities in kW given for 45 C water leaving temperature and 7 C ambient temperature.Ratings in accordance with EN14511 and EN14825.19222003

YORK AMICHI SERIES AIR-COOLED DC INVERTERSCROLL CHILLERS AND HEAT PUMPS44-254kW

Johnson Controls, the Johnson Controls logo, the Smart Equipment logo, YORK and Verasys are registered trademarks of Johnson Controls, Inc.in the United States of America and other countries. Other trademarks used herein may be trademarks or registered trademarks of other companies. 2017 Johnson Controls, Inc. P.O. Box 423, Milwaukee, WI 53201. All rights reserved worldwide. Printed in USA PUBL-8740-A-1017.FOR MORE INFORMATION VISIT JOHNSONCONTROLS.COM

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS 44-254kW Exceeding Efficiency Standards The YORK Amichi Series Air-cooled DC Inverter Scroll Chiller and Heat Pump have been designed to meet tomorrow's efficiency standards today. Delivering performance beyond typical chiller and heat pump efficiency levels, the YORK Amichi Series

Related Documents:

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS 45-60k W Exceeding Efficiency Standards The YORK Amichi Series Air-cooled DC Inverter Scroll Chiller and Heat Pump have been designed to meet tomorrow’s efficiency standards today. Delivering performance beyond typical chiller and heat pump eff

Air Cooled Chiller Air Air 2 Air Air 6 AIR COOLED CHILLERS Air-cooled chillers are refrigeration machines that remove heat from cooling loads using chilled water and reject this heat into the atmosphere using refrigerant. THEY ALL HAVE fans, condenser coils, and compressors. Air-cooled chillers are used to provide cooling for human comfort and electronic equipment as well as industrial process .

Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 80 F chilled water. MAXIMUM SERIES † Air & Water-Cooled † 1/4 to 40 Tons † 20 F to 80 F † Using Non-Ozone Depleting Refrigerants 10 ton air-cooled model 10 ton water-cooled model 2 ton water-cooled model 1 ton air-cooled model

ACH Air-Cooled, Horizontal Air Flow ACV Air-Cooled, Vertical Air Flow ACR Air-Cooled Remote Condenser WCC Water-Cooled Condenser Digit 6 — Chilled Water System P Recirculating System, Tank and Pump M Single Pass Chiller Unit (no tank and pump) Digit 7 — Cabinet Type H Horizontal Low Profile V Vertical Upright

Vanguard Air-Cooled V-Twin Specifications Performance Curves 14 HP Vanguard Air-Cooled V-Twin 16 HP Vanguard Air-Cooled V-Twin 15.0 5.2 Kilowatt 7.5 8.2 9.0 9.7 10.4 111.2 111.9 14.0 13.0 12.0 11.0 10.0 9.0 8.0 7.0 16.0 6.7 6.0 HP 1800 2000 2200 24002600 2800 3000 3200 3400 3600 17.0 12.7 REVOLUTIONS PER MINUTE RATED GROSS BHP MAXIMUM .

EWY Air-cooled chiller, heat pump EWL Remote condenser chiller ERA Air cooled condensing unit EWW Water-cooled chiller, cooling only EWC Air-cooled chiller, cooling only with centrifugal fan EWT Air-cooled chiller, cooling only with heat recovery Refrigerant D R-134a P R-407c Q R-410a Capacity class in kW (Cooling) Always 3 .

AIR-COOLED Air-Cooled chillers utilize plant ambient air to extract heat from the refrigeration circuit. Fan or blowers move the plant air across generously sized finned condenser coils to permit full rated capacity at design conditions. WATER-COOLED Water-Cooled chillers utilize a secondary plant water source such as cooling tower or city .

Pratiyogita Darpan Extra Issue Series-23 Public Administration - 1967 - - Pratiyogita Darpan Editorial Team 507 pages - Public administration - Public Administration: Concepts And Theories - 2004 - - Rumki Basu Apr 14, 2009. PARDEEP SAHNI, ETAKULA VAYUNANDAN. This book presents a detailed introduction to the