Migration SolutionsE3/E3 Plus to E300/E200 Electronic Overload RelayWhy Upgrade or MigrateWhile the E3/E3 Plus Overload Relay hasbeen a valuable part of our portfoliofor the past twenty years, this productwill no longer be available for saleafter October 2019.* Now is the timeto migrate to the E300 or E200 Electronic Overload Relay. As the lateststate-of-the-art electronic overloadrelay offering, the E300/E200 ElectronicOverload Relay offers many modularfeatures designed to help improve yourmotor control and protection needs.E3/E3 PlusElectronic Overload RelayE300/E200 BasicProduct Overview Modular design for applicationcustomization with various sensing,control and communicationmodule options Diagnostic information to monitormotor performance– Current, voltage, powerand energy– % Thermal capacity utilization– Time to trip/reset– Trip snapshot– Trip/warning histories Logix integration with add-onprofiles, add-on instructions and preconfigured operator faceplate objects Supports Automatic DeviceConfiguration (ADC-EtherNet/IP)and Automatic Device Replacement(ADR-DeviceNet) DeviceLogix Technology Enabled Optional Dual port EtherNet/IP, Singleport DeviceNet or Universal Serial Bus(USB) communication options*Discontinued date may be subject to change.E300/E200Electronic Overload RelayWhy Upgrade or Migrate?Rockwell Automation understands that your overload relays are acritical asset in your automation system, and we support that byproviding you with the latest technology to maximize your investment.New technologies can improve and extend the operation of existingequipment and provide an immediate boost to productivity. By migratingfrom your legacy E3/E3 Plus Overload to a new E300/E200 ElectronicOverload Relay, you can help to decrease downtime, increase speed tomarket, and optimize operations well into the future.We will help you to meet this demand to innovate by proactivelyplanning and managing your transition every step of the way to helpyou get the highest possible return on your automation investment.ACTIVE*ACTIVE MATURE*END OF LIFE*DISCONTINUED**ACTIVE: Most current offering within a product category.ACTIVE MATURE: Product is fully supported, but a newer product or family exists. Gain value by migrating.END OF LIFE: Discontinued date announced – actively execute migrations and last time buys. Product generally orderable until thediscontinued date.1DISCONTINUED: New product no longer manufactured or procured.2 Repair/exchange services may be available.1 - Outages on specific items may occur prior to the Discontinued date. 2 - Limited stock may be available in run-out mode, regionally.

E3/E3 Plus to E300/E200 Electronic Overload t Range (A)Thermal OverloadAuto or Manual ResetMechanical Jam (Stall)UndercurrentPhase LossZero Sequence Ground FaultPhase ReversalCurrent ImbalancePTC Thermistor MonitoringStarts / HourTime Between StartsSpeed Switch InputUndervoltageOvervoltagePower e PowerResistance Temperature Detection (RTD)Heat TracePhase Current MagnitudesThree-Phase Average CurrentPercent Motor LoadCurrent Imbalance PercentageGround Current MagnitudeSystem FrequencyPhase Voltage MagnitudesAverage VoltageVoltage Imbalance PercentageReal Power (kW)Reactive Power (kVAR)Apparent Power (kVA)Power FactorEnergy (kWhr)kVARhr% Thermal Capacity Used (TCU)Starts AvailableResistance Temperature Detection (RTD)Output RelaysDigital InputsAnalog OutputsAnalog InputEtherNet/IP CommunicationsDeviceNet CommunicationsUniversal Serial Bus (USB) Type BStudio5000/Logix CompatibleDeviceLogix TechnologySupported in Connected ComponentsWorkbench (CCW)ANSI/IEEEDevice /A49N/AEC1EC20.4 5000333330.4 2233EC3EC4EC5E200E3000.4 500033333333333333333330.5 65000333333333333333333330.5 33333332-112-223-121-4330.4 5000 0.4 5000333333333333333333333333333

Migration Options & ApplicationThe E200/E300 Electronic Overload Relay provides a flexible design and advanced intelligence. With real-time motordiagnostic information to proactively indicate when a motor is having a problem allowing you to efficiently troubleshoot.Communication Module193-ECM*Features EtherNet/IP DeviceNet E200/Parameter Configuration Module (PCM)*Ideal Applications*Includes Single USB Type B interface port Control Module193-EIO*Control Voltage110 120V AC50/60 Hz220 240V AC50/60 Hz24V DCI/OI/O and ProtectionInputsRelay OutputsInputsRelay ty Wide current range Advanced performanceand diagnostics Embeddedcommunications Modularity Multiple expansion optionsSensing Module592/193ESM*Sensing Options: Voltage/Current/Ground Fault Current/Ground Fault urrent Range: 0.5 30 A 6 60 A 10 100 A 20 200 ACurrent transformer solutionsavailable for applications above 200 A* Must use a combination of all three modules to create a completeE300/E200 Overload Relay.Dimensional Comparison of E3 Plus to E300The mounting footprint of the E3/E3 Plus as compared to the E200/E300 is relatively the same. In addition, the E200/E300offers a specific sensing module (“E3T” suffix) that provides an identical DIN-RAIL or panel-mount configuration.E3/E3 PlusPROFILE148 mm45 mmE3/E3 PlusE300115 mmE30045 mm126 mmFRONT

Electrical Comparison of E3 Plus to E300The terminal layout of the E200/E300 is similar to that of the E3/E3 Plus Overload. In addition, the E200/E300 offers a robustset of removal terminal blocks for easier installation and/or device replacement.E3 PlusE200/E300DeviceNet Communication ConfigurationThe E3/E3 Plus overload received its 24VDC power from the DeviceNet communication trunk. The E300 overload hasmultiple voltage supply options of 24VDC, 120VAC, and 240VAC. If utilizing the E300 24VDC supply option in conjunctionwith the E300 DeviceNet communication module, the 24VDC can be sourced from the DeviceNet communication trunk orvia other external means. The E300 DeviceNet communication module consumes a maximum current of 50 mA at 24VDC.If multiple voltage supply options are required, E200/E300 expansion I/O can be added.

Programming Comparison of E3 Plus to E300 & Emulation ModeThe E300 Overload Relay used with the Series B Control Module (Note: Series A not supported) supports an E3/E3 Plus overloadrelay “Emulation Mode” when it is attached to a DeviceNet Communication Module. This allows a user to re-use configurationparameters from the E3/E3 Plus overload relay when utilizing configuration tools like ADR, the DeviceNet ConfigurationTerminal (193-DNCT), and RSNetWorx for DeviceNet. The Emulation Mode feature when enabled, replicates exactly the legacyparameter set of the target E3/E3 Plus device it is emulating. As such, the DeviceNet input/output assemblies are identical.Below is a table which provides a list of valid E3/E3 Plus emulated profiles that the E300 on DeviceNet supports. The E300 onDeviceNet supports RSNetWorx for DeviceNet Revision 27.00.00 or later. Proper interface within the software for the E300 andEmulation Mode profiles require separate EDS files which are available for download from the PCDC.E3 (1 5 A)E3 Plus (1 5 A)E3 (3 15 A)E3 Plus (3 15 A)E3 (5 25 A)E3 Plus (5 25 A)E3 (9 45 A)E3 Plus (9 45 A)E3 (18 90 A)E3 Plus (18 90 A)E3 (0.4 2 A)E3 Plus (0.4 2 A)E3 (9 5000 A)E3 EC3 (1 5 A)E3 EC3 (3 15 A)E3 EC3 (5 25 A)E3 EC3 (9 45 A)E3 EC3 (18 90 A)E3 EC3 (0.4 2 A)E3 EC3 (9 5000 A)E3 EC4 (1 5 A)E3 EC4 (3 15 A)E3 EC4 (5 25 A)E3 EC4 (9 45 A)E3 EC4 (18 90 A)E3 EC4 (0.4 2 A)E3 EC4 (9 5000 A)E3 EC5 (1 5 A)E3 EC5 (3 15 A)E3 EC5 (5 25 A)E3 EC5 (9 45 A)E3 EC5 (18 90 A)E3 EC5 (0.4 2 A)E3 EC5 (9 5000 45658606264666870727476DescriptionLowerName StringModelProductCodeValid E300 DeviceNet Emulated E3/E3 Plus ProfilesSchematic EC5EC5E3E3 PlusE3E3 PlusE3E3 PlusE3E3 PlusE3E3 PlusE3E3 PlusE3E3 Plus external GF onlyE3 Plus external GF onlyE3 Plus external GF onlyE3 Plus external GF onlyE3 Plus external GF onlyE3 Plus external GF onlyE3 Plus external GF onlyE3 Plus non-motorE3 Plus non-motorE3 Plus non-motorE3 Plus non-motorE3 Plus non-motorE3 Plus non-motorE3 Plus non-motorE3 Plus w/Voltage, external GF onlyE3 Plus w/Voltage, external GF onlyE3 Plus w/Voltage, external GF onlyE3 Plus w/Voltage, external GF onlyE3 Plus w/Voltage, external GF onlyE3 Plus w/Voltage, external GF onlyE3 Plus w/Voltage, external GF only(1 5 A)(1 5 A)(3 15 A)(3 15 A)(5 25 A)(5 25 A)(9 45 A)(9 45 A)(18 90 A)(18 90 A)(0.4 2 A)(0.4 2 A)(9 5000 A)(1 5 A)(3 15 A)(5 25 A)(9 45 A)(18 90 A)(0.4 2 A)(9 5000 A)(1 5 A)(3 15 A)(5 25 A)(9 45 A)(18 90 A)(0.4 2 A)(9 5000 A)(1 5 A)(3 15 A)(5 25 A)(9 45 A)(18 90 A)(0.4 2 A)(9 5000 00051525459025000Emulation Mode Parameter 300 3 [E3 (1 5 A)]Emulation Mode Parameter 300 4 [E3 Plus (1 5 A)]Emulation Mode Parameter 300 5 [E3 (3 15 A)]Emulation Mode Parameter 300 6 [E3 Plus (3 15 A)]Emulation Mode Parameter 300 7 [E3 (5 25 A)]Emulation Mode Parameter 300 8 [E3 Plus (5 25 A)]Emulation Mode Parameter 300 9 [E3 (9 45 A)]Emulation Mode Parameter 300 10 [E3 Plus (9 45 A)]Emulation Mode Parameter 300 11 [E3 (18 90 A)]Emulation Mode Parameter 300 12 [E3 Plus (18 90 A)]Emulation Mode Parameter 300 29 [E3 (0.4 2 A)]Emulation Mode Parameter 300 30 [E3 Plus (0.4 2 A)]Emulation Mode Parameter 300 31 [E3 EC1 (9 5000 A)]Emulation Mode Parameter 300 36 [E3 EC3 (1 5 A)]Emulation Mode Parameter 300 38 [E3 EC3 (3 15 A)]Emulation Mode Parameter 300 40 [E3 EC3 (5 25 A)]Emulation Mode Parameter 300 42 [E3 EC3 (9 45 A)]Emulation Mode Parameter 300 44 [E3 EC3 (18 90 A)]Emulation Mode Parameter 300 46 [E3 EC3 (0.4 2 A)]Emulation Mode Parameter 300 48 [E3 EC3 (9 5000 A)]Emulation Mode Parameter 300 50 [E3 EC4 (1 5 A)]Emulation Mode Parameter 300 52 [E3 EC4 (3 15 A)]Emulation Mode Parameter 300 54 [E3 EC4 (5 25 A)]Emulation Mode Parameter 300 56 [E3 EC4 (9 45 A)]Emulation Mode Parameter 300 58 [E3 EC4 (18 90 A)]Emulation Mode Parameter 300 60 [E3 EC4 (0.4 2 A)]Emulation Mode Parameter 300 62 [E3 EC4 (9 5000 A)]Emulation Mode Parameter 300 64 [E3 EC5 (1 5 A)]Emulation Mode Parameter 300 66 [E3 EC5 (3 15 A)]Emulation Mode Parameter 300 68 [E3 EC5 (5 25 A)]Emulation Mode Parameter 300 70 [E3 EC5 (9 45 A)]Emulation Mode Parameter 300 72 [E3 EC5 (18 90 A)]Emulation Mode Parameter 300 74 [E3 EC5 (0.4 2 A)]Emulation Mode Parameter 300 76 [E3 EC5 (9 5000 A)]E300 Emulation Mode –I/O MappingE3/E3 Plus I/OOutputsOut A – 13/14Out B – 23/24OL Trip – 95/96InputsIN1IN2IN3IN4E300 on DNet I/Owhile in E3 PlusEmulation ModeRelay 0 – R03/R04Relay 2 – R23/R24*Relay 1 – R13/14IN0IN1IN2IN3* This output is not available for E300 controlmodules that have fewer than 3 outputs.Once the OL is in Emulation Mode, at left are the respective non-configurable I/Omappings for the device.Note: In the event the E300 control module does not have sufficient I/O for theemulated E3/E3 Plus, a single expansion I/O module can be used to supplement for theremaining I/O. However, the number of I/O points cannot exceed that of the device it isemulating (i.e. expansion I/O beyond that which is needed for emulation mode will notbe usable). The expansion operator diagnostic station (SDS) can be used to enable ordisable Emulation Mode, but does not provide any functionality beyond that.The SDS will also indicate when Emulation is enabled. The E300 while in emulationmode will accept E3 Plus DeviceLogix (DLX) code via ADR or through RSNetWorx forDeviceNet. It requires a couple of extra simple steps that the user needs to perform:Step 1: Select the desired E3 Plus emulation mode profile (parameter 300 – E300 Mode)Step 2: Enable E3 Plus Translate DLX Code (parameter 305 – E3 Plus Emulation Mode).This second step will convert E3 Plus DLX code written with v1.0 of the DLX library tov5.0 of the DLX library that runs within the E300 OL.

Component Cross-reference TableDiscontinuedPart NumberE3/E3 Plus ContactorMounting/DescriptionE3/E3 PlusFLA RangeRecommended E300Replacement Part NumbersConversion 193-EC1CB193-EC1CD0.4 - 2.0A1 - 5A1 - 5A3 - 15A3 - 15A5 - 25A5 - 25A193-ECM-DNT 193-ESM-I-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-I-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-I-30A-C55 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-I-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-I-30A-C55 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-I-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-I-30A-C55 193-EIOxx-xx-xxxSensing Module current range is 0.5 - 30ADirect contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E3009 - 45A193-ECM-DNT 193-ESM-I-60A-C55 193-EIOxx-xx-xxxDirect contactor mounting available with 0-C23100-C09.100-C23, 300-AO*100-C30.100-C43100-C09.100-C23, 300-AO*100-C30.100-C43100-C09.100-C23, 300-AO*100-C30.100-C43100-C30.100-C43, 300-BO*,300-CO*100-C60.100-C97100-C60.100-C97, 300-DO*100-D95.100-D180100-D95.100-D180, 300-EO*9 - 45A18 - 90A28 - 140A42 - 210ADirect contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300193-EC1GG100-D210.100-D420, 300-FO*42 - 210A193-EC1HG100-D210.100-D420, 300-FO*60 - 302A193-EC1JG100-D210.100-D42084 - 420A193-EC1KH100-D630.100-D860125 - 630A193-EC1LH100-D630.100-D860172 - 93-EC2BD193-EC2CB193-EC2CD9 - 5000A0.4 - 2.0A1 - 5A1 - 5A3 - 15A3 - 15A5 - 25A5 - 25A9 - 45A193-ECM-DNT 193-ESM-IG-60A-C55 193-EIOxx-xx-xxxDirect contactor mounting available with E300193-EC2DE193-EC2EE193-EC2FF193-EC2GFPanel Mount Only100-C09.100-C23100-C09.100-C23, 300-AO*100-C30.100-C43100-C09.100-C23, 300-AO*100-C30.100-C43100-C09.100-C23, 300-AO*100-C30.100-C43100-C30.100-C43, 300-BO*,300-CO*100-C60.100-C97100-C60.100-C97, 300-DO*100-D95.100-D180100-D95.100-D180, 300-EO*193-ECM-DNT 193-ESM-I-100A-C97 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-I-100A-C97 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-I-200A-D180 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-I-200A-D180 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-I-30A-T 193-EIOxx-xx-xxx 1411-180RL-201(3 required)193-ECM-DNT 193-ESM-I-30A-T 193-EIOxx-xx-xxx 1411-180RL-301(3 required)193-ECM-DNT 193-ESM-I-30A-T 193-EIOxx-xx-xxx 1411-180RL-401(3 required)193-ECM-DNT 193-ESM-I-30A-T 193-EIOxx-xx-xxx 1411-180RL-601(3 required)193-ECM-DNT 193-ESM-I-30A-T 193-EIOxx-xx-xxx 1411-180RL-102(3 required)193-ECM-DNT 193-ESM-I-30A-E3T 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-C55 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-C55 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-C55 193-EIOxx-xx-xxx9 - 45A18 - 90A28 - 140A42 - 210ADirect contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300193-EC2GG100-D210.100-D420, 300-FO*42 - 210A193-EC2HG100-D210.100-D420, 300-FO*60 - 302A193-EC2JG100-D210.100-D42084 - 420A193-EC2KH100-D630.100-D860125 - 630A193-EC2LH100-D630.100-D860172 - .4 - 2.0A1 - 5A3 - 15A5 - 25A5 - 25A9 - 45A193-ECM-DNT 193-ESM-IG-60A-C55 193-EIOxx-xx-xxxDirect contactor mounting available with 0-C23100-C09.100-C23, 300-AO*100-C09.100-C23, 300-AO*100-C09.100-C23, 300-AO*100-C30.100-C43100-C30.100-C43, 300-BO*,300-CO*100-C60.100-C97100-C60.100-C97, 300-DO*100-D95.100-D180100-D95.100-D180, 300-EO*193-ECM-DNT 193-ESM-IG-100A-C97 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-100A-C97 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-200A-D180 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-200A-D180 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-T 193-EIOxx-xx-xxx 1411-180RL-201(3 required)193-ECM-DNT 193-ESM-IG-30A-T 193-EIOxx-xx-xxx 1411-180RL-301(3 required)193-ECM-DNT 193-ESM-IG-30A-T 193-EIOxx-xx-xxx 1411-180RL-401(3 required)193-ECM-DNT 193-ESM-IG-30A-T 193-EIOxx-xx-xxx 1411-180RL-601(3 required)193-ECM-DNT 193-ESM-IG-30A-T 193-EIOxx-xx-xxx 1411-180RL-102(3 required)193-ECM-DNT 193-ESM-IG-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-C55 193-EIOxx-xx-xxx9 - 45A18 - 90A28 - 140A42 - 210ADirect contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300193-EC3GG100-D210.100-D420, 300-FO*42 - 210A193-EC3HG100-D210.100-D420, 300-FO*60 - 302A193-EC3JG100-D210.100-D42084 - 420A193-EC3KH100-D630.100-D860125 - 630A193-EC3LH100-D630.100-D860172 - 860A193-EC3ZZPanel Mount Only9 - 5000A193-ECM-DNT 193-ESM-IG-100A-C97 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-100A-C97 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-200A-D180 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-200A-D180 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-T 193-EIOxx-xx-xxx 1411-180RL-201(3 required)193-ECM-DNT 193-ESM-IG-30A-T 193-EIOxx-xx-xxx 1411-180RL-301(3 required)193-ECM-DNT 193-ESM-IG-30A-T 193-EIOxx-xx-xxx 1411-180RL-401(3 required)193-ECM-DNT 193-ESM-IG-30A-T 193-EIOxx-xx-xxx 1411-180RL-601(3 required)193-ECM-DNT 193-ESM-IG-30A-T 193-EIOxx-xx-xxx 1411-180RL-102(3 required)193-ECM-DNT 193-ESM-IG-30A-E3T 193-EIOxx-xx-xxx193-EC1DD193-EC2DD193-EC3DDNo direct contactor mounting is available in E300 lineNo direct contactor mounting is available in E300 lineNo direct contactor mounting is available in E300 lineNo direct contactor mounting is available in E300 lineNo direct contactor mounting is available in E300 lineDirect contactor mounting available with E300Sensing Module current range is 0.5 - 30ADirect contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300No direct contactor mounting is available in E300 lineNo direct contactor mounting is available in E300 lineNo direct contactor mounting is available in E300 lineNo direct contactor mounting is available in E300 lineNo direct contactor mounting is available in E300 lineSensing Module current range is 0.5 - 30ADirect contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300No direct contactor mounting is available in E300 lineNo direct contactor mounting is available in E300 lineNo direct contactor mounting is available in E300 lineNo direct contactor mounting is available in E300 lineNo direct contactor mounting is available in E300 lineDirect contactor mounting available with E300

Component Cross-reference Table continuedDiscontinuedPart NumberE3/E3 Plus ContactorMounting/DescriptionE3/E3 PlusFLA RangeRecommended E300Replacement Part C5DD193-EC5DE193-EC5EE193-EC5FFPanel Mount 00-C09.100-C23100-C30.100-C43100-C60.100-C97Panel Mount -C97100-D95.100-D1809 - 5000A0.4 - 2.0A1 - 5A3 - 15A5 - 25A9 - 45A18 - 90A9 - 5000A0.4 - 2.0A1 - 5A1 - 5A3 - 15A3 - 15A5 - 25A5 - 25A9 - 45A9 - 45A18 - 90A28 - 140A193-EC5GF100-D95.100-D18042 - 210A193-EC5GG100-D210.100-D42042 - 210A193-EC5HG100-D210.100-D42060 - 302A193-EC5JG100-D210.100-D42084 - 420A193-EC5KH100-D630.100-D860125 - 630A193-EC5LH100-D630.100-D860172 - 2-EC3PC592-EC3AC592-EC3BC592-EC3CCPanel Mount OnlyPanel Mount OnlyPanel Mount OnlyPanel Mount OnlyNEMA Size 0 - 2Panel Mount Only NEMA Size 00NEMA Size 0 - 2Panel Mount Only NEMA Size 00NEMA Size 0 - 2Panel Mount Only NEMA Size 00NEMA Size 0 - 2NEMA Size 0 - 2NEMA Size 3NEMA Size 4NEMA Size 0 - 2NEMA Size 0 - 2Panel Mount Only NEMA Size 00NEMA Size 0 - 2NEMA Size 0 - 2Panel Mount Only NEMA Size 00NEMA Size 0 - 2NEMA Size 0 - 2Panel Mount Only NEMA Size 00NEMA Size 0 - 2NEMA Size 0 - 2NEMA Size 0 - 2NEMA Size 0 - 2NEMA Size 3NEMA Size 3NEMA Size 3NEMA Size 0 - 2NEMA Size 0 - 2NEMA Size 0 - 2NEMA Size 0 - 29 - 5000A9 - 5000A9 - 5000A9 - 5000A0.4 - 2.0A0.4 - 2.0A1 - 5A1 - 5A3 - 15A3 - 15A5 - 25A9 - 45A9 - 45A18 - 90A0.4 - 2.0A0.4 - 2.0A0.4 - 2.0A1 - 5A1 - 5A1 - 5A3 - 15A3 - 15A3 - 15A5 - 25A5 - 25A9 - 45A9 - 45A9 - 45A18 - 90A18 - 90A0.4 - 2.0A1 - 5A3 - 15A5 - 25A193-ECM-DNT 193-ESM-IG-30A-E3T 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-100A-S3 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-100A-C97 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-E3T 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-VIG-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-VIG-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-VIG-30A-C55 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-VIG-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-VIG-30A-C55 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-VIG-30A-C23 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-VIG-30A-C55 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-VIG-60A-C55 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-VIG-100A-C97 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-VIG-100A-C97 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-VIG-200A-D180 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-VIG-30A-E3T 193-EIOxx-xx-xxx 1411-180RL-201(3 required)193-ECM-DNT 193-ESM-VIG-30A-E3T 193-EIOxx-xx-xxx 1411-180RL-201(3 required)193-ECM-DNT 193-ESM-VIG-30A-E3T 193-EIOxx-xx-xxx 1411-180RL-301(3 required)193-ECM-DNT 193-ESM-VIG-30A-E3T 193-EIOxx-xx-xxx 1411-180RL-401(3 required)193-ECM-DNT 193-ESM-VIG-30A-E3T 193-EIOxx-xx-xxx 1411-180RL-601(3 required)193-ECM-DNT 193-ESM-VIG-30A-E3T 193-EIOxx-xx-xxx 1411-180RL-102(3 required)193-ECM-DNT 193-ESM-VIG-30A-E3T 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-I-30A-E3T 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-E3T 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-VIG-30A-E3T 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-I-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-I-30A-E3T 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-I-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-I-30A-E3T 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-I-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-I-30A-E3T 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-I-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-I-60A-S2 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-I-100A-S3 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-I-100A-S3 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-E3T 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-E3T 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-E3T 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-60A-S2 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-60A-S2 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-100A-S3 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-100A-S3 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-100A-S3 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-30A-S2 193-EIOxx-xx-xxxConversion NotesDirect contactor mounting available with E300Sensing Module current range is 0.5 - 30ADirect contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Sensing Module current range is 0.5 - 30ADirect contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300No direct contactor mounting is available in E300 lineNo direct contactor mounting is available in E300 lineNo direct contactor mounting is available in E300 lineNo direct contactor mounting is available in E300 lineNo direct contactor mounting is available in E300 lineNo direct contactor mounting is available in E300 lineDirect contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300

Component Cross-reference Table continuedDiscontinuedPart NumberE3/E3 Plus ContactorMounting/DescriptionE3/E3 PlusFLA RangeRecommended E300Replacement Part Numbers592-EC3DC592-EC3ED592-EC3FENEMA Size 0 - 2NEMA Size 3NEMA Size 49 - 45A18 - 90A28 - 140A592-EC3HFNEMA Size 560 - 302A592-EC3KGNEMA Size 6125 - 92-EC5ED592-EC5FENEMA Size 0 - 2NEMA Size 0 - 2NEMA Size 0 - 2NEMA Size 0 - 2NEMA Size 0 - 2NEMA Size 3NEMA Size 40.4 - 2.0A1 - 5A3 - 15A5 - 25A9 - 45A18 - 90A28 - 140A592-EC5HFNEMA Size 560 - 302A592-EC5KGNEMA Size 6125 - 630A193-ECPM1Panel Mount OnlyPanel Adapter193-ECPM2Panel Mount OnlyPanel Adapter193-ECPM3Panel Mount OnlyPanel Adapter193-ECM-DNT 592-ESM-IG-60A-S2 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-100A-S3 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-IG-200A-S4 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-IG-30A-T 193-EIOxx-xx-xxx 1411-180RL-301(3 required)193-ECM-DNT 193-ESM-IG-30A-T 193-EIOxx-xx-xxx 1411-180RL-601(3 required)193-ECM-DNT 592-ESM-VIG-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-VIG-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-VIG-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-VIG-30A-S2 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-VIG-60A-S2 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-VIG-100A-S3 193-EIOxx-xx-xxx193-ECM-DNT 592-ESM-VIG-200A-S4 193-EIOxx-xx-xxx193-ECM-DNT 193-ESM-VIG-30A-CT 193-EIOxx-xx-xxx 1411-180RL-301(3 required)193-ECM-DNT 193-ESM-VIG-30A-CT 193-EIOxx-xx-xxx 1411-180RL-601(3 required)193-ECM-DNT 193-EIOxx-xx-xxx 193-ESM-I-30A-E3T or193-ESM-I-60A-E3T or 193-ESM-I-100A-E3T193-ECM-DNT 193-EIOxx-xx-xxx 193-ESM-I-30A-E3T or193-ESM-I-60A-E3T or 193-ESM-I-100A-E3T193-ECM-DNT 193-EIOxx-xx-xxx 193-ESM-I-30A-E3T or193-ESM-I-60A-E3T or 193-ESM-I-100A-E3T193-EIMD120V Input Interface Module193-EIMD60120V Input Interface Module(60Hz Only)120V InputInterfaceModule120V InputInterfaceModuleConversion NotesDirect contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300No direct contactor mounting is available in E300 lineNo direct contactor mounting is available in E300 lineDirect contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mounting available with E300Direct contactor mo

Electronic Overload Relay. As the latest state-of-the-art electronic overload relay offering, the E300/E200 Electronic Overload Relay offers many modular features designed to help improve your motor control and protection needs. E300/E200 Basic Product Overview Modular design for application customization with various sensing,

Related Documents:

eSurvey E300 U300351810033 eSurvey E300 E300 Receive Quick Start Guide. Instrument set-up 08 2.1 Base station Tribrach and tripod are not standard configuration accessories, users can purchase separately. 02 A B E C D A. E300 receiver B. Support rod C. Tribrach D. Tripod E. Built-in radio antenna

2 Medmont E300 Corneal Topographer 2. Intended Purpose The Medmont E300 Corneal Topographer is a computerised Video-keratometer using Placido rings to map the surface of the human cornea. The map is captured in three-dimensions and can be

The Medmont E300 Corneal Topographer is a computerised Video-keratometer using Placido rings to map the surface of the human cornea. The map is captured in three-dimensions and can be displayed subsequently using a number of representations. The cornea map can

p:\installation inst\electromagnetic locks\excel\inst-e300.vsd rev b 06-15 page 2 step 2 mount the armature plate to door using (1 ) rubber washer sandwiched between (2) steel washers (the rubber washer and (2) steel washers are installed on the mounting bolt between the armatu

E300 Electronic Overload Relay Bu

The E300 Enterprise Branch Router is 5G ready and can act as a controller for a Cradlepoint 5G wideband adapter. This capability ensures upward compatibility for 5G, while still allowing optimal to operate the adapter in captive mode means that the two separate, Ethernet-connected, appliances can be managed as a single entity. Stateful Firewall

work/products (Beading, Candles, Carving, Food Products, Soap, Weaving, etc.) ⃝I understand that if my work contains Indigenous visual representation that it is a reflection of the Indigenous culture of my native region. ⃝To the best of my knowledge, my work/products fall within Craft Council standards and expectations with respect to

are granted in electrical, electronics, mechanical, or civil engineering. However, engineers trained in one branch may work in related branches. For example, many aerospace engineers have training in mechanical engineering. This flexibility allows employers to meet staffing needs in new technologies and specialties in which engineers may be in short supply. It also allows engineers to shift to .