IBM TotalStorage LTO Ultrium Tape Drive SCSI Reference GA32-0450-10

IBM TotalStorage LTO Ultrium Tape Drive SCSI Reference GA32-0450-10

Note Before using this manual and the product it supports, read the information under Appendix B, “Notices,” on page 313. Eleventh Edition (April 2009) This edition applies to the IBM TotalStorage LTO Ultrium Tape Drive SCSI Reference and to all subsequent releases and modifications unless otherwise indicated in new editions. Copyright International Business Machines Corporation 2002, 2009. US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.

Read This First This is the eleventh edition of the IBM TotalStorage LTO Ultrium Tape Drive SCSI Reference (April 2009). Summary of Changes Second Edition, April 2004 The following changes were made in this edition: v Added features of the 3580 Tape Drive Models L23 and H23. v Modified to show that the generation 2 drive code ignores the Page Control (PC) field. v Modified parameters and descriptions in Table 53 on page 59. v Modified Table 70 on page 76 to show added support for TapeAlerts 51, 52, and 53 and to show removed claim support for flags 19, 35, and 38. v Modified the Medium Type field definition in section “Mode Parameter Header” on page 113. v Modified sections“Mode Page 0Fh: Data Compression Mode Page” on page 121 and “Mode Page 10h: Sequential Access Device Configuration Page” on page 123 to reflect that now the Emerald drive’s behavior matches that of the Sapphire drive. v Modified the Text Generation value in Table 151 on page 167. v Modified section Table 152 on page 168 to show that Medium Auxiliary Memory parameters 1400h-17FFh of Application Specific Data can be written to Cartridge Memory as long as space is available. v Modified section“READ POSITION” on page 183 to correctly state the behavior of the READ POSITION command after a READ type command. v Modified section “SET CAPACITY (not Ultrium 1)” on page 254 to show that Check Condition status is returned with Illegal Field in CDB (5/2400h) if the Capacity Proportion Value of a new cartridge becomes smaller than 17.2 GB. Third Edition, December 2004 The following changes were made in this edition: v Added Generation 3 (Ultrium 3 Support). v Added LTO Gen 3 log pages, as appropriate. v Added support for IBM TotalStorage 3580 Tape Drive Models L33/L3H. v Added support for IBM TotalStorage Ultrium 3 Tape Drive. v Added support for IBM TotalStorage 400 GB Data Cartridge. v Added new required items to Inquiry pages in the section entitled “INQUIRY” on page 21. v Changed values of BQue field and CmdQ field in the section entitled “Standard Inquiry Data” on page 22. v Added new log sense data and additional supported log pages (see “LOG SENSE” on page 51). v Replaced TapeAlert Log Parameters in Table 70 on page 76. Copyright IBM Corp. 2002, 2009 iii

v Created a mode page that can be saved and used to configure behavior changes to a drive (see “Mode Page 2Fh: Behavior Configuration Mode Page” on page 137). v Added speed matching and defined a byte field to be used to distinguish between a full performance drive and a non-performance limited drive (see “Sense Data Format” on page 199). Fourth Edition, March 2005 The following changes were made in this edition: v Added Fibre Channel support. Fifth Edition, May 2006 The following changes were made in this edition: v Added Space (16) command to Chapter 3. v Added Chapter 8 Firmware Download. Sixth Edition, December 2006 The following changes were made in this edition: v Added additional sense values to Chapter 7, “Sense Keys and Additional Sense,” on page 275 v Added support for the Tape Data Encryption Security Protocol of the Security Protocol In and Security Protocol Out commands Seventh Edition, June 2007 Information to update this edition was obtained from the following Functional Change Request documents (FCRs): v FCR 3056 - LTO Emulate WORM Additions v FCR 3048 - LTO WORM Read Attribute Behavior v FCR 3059r1 - Add support for Load Unload Hold bit v v v v v v v FCR FCR FCR FCR FCR FCR FCR 3078 3080 3089 3096 3097 3099 3103 - SPC-4 Set Timestamp and Report Timestamp Encryption Counters Component Revision Level Inquiry Page LTO TapeAlert 22 Clearing Behavior Change LTO Limit ERP LTO HH Changes New Thread Unthread Additional Sense Code v v v v v v v FCR FCR FCR FCR FCR FCR FCR 3104 - Log Pages 14h & 16h 3105 - LTO Set Capacity - Return to LP4 3106 - Log Page 11h on LUN 0 3107 - Allow Read Attribute when CM Accessible 3108 - LTO Read dump with strictly increasing offsets 3109r1 - Send Diagnostic (Read Thermal Sensor) 3112 - LTO4 (J2E Encryption Method) v FCR 3121r2 - License Keys (LTO) (Internal with Inquiry Data) v FCR 3122 - LTO Log Page 30h - Tape Usage Log Updates v FCR 3123 - Component Revision Level Inquiry Page v FCR 3124 - LTO Dead Media reporting (page 2F) iv IBM TotalStorage LTO Ultrium Tape Drive: SCSI Reference

v FCR 3128 - LTO Log Page 31 Clarification v FCR 3130 - LTO pSCSI U320 Support v FCR 3132 - Mode Parameter Speed Field Eighth Edition, July 2007 Information to update this edition was obtained from the following Functional Change Request documents (FCRs): v FCR 3133 - LTO Inquiry page C8h v FCR 3136r0 - LTO ITD Pages (Entire Set) v FCR 3112 - LTO 4 (J2E Encryption Method) v FCR 3130 - LTO pSCSI U320 Support v FCR 3131 - Direct Key Labels v FCR 3139 - Mode Page 2F Cleanup for Pubs. Ninth Edition, August/September 2007 Changes and additions to the following Chapters and subsections in the ninth edition are listed as follows: v Related Publications section – The last bulleted item is changed to reference the Ultrium 4 tape drive. v Chapter 1. Introduction: – The second paragraph now includes Serial Attached SCSI (SAS) Interface. – The subsection titled SCSI and Fibre Channel Attachment was changed to Primary Interface Attachment. v Chapter 2. Summary of Drive Generation Differences – Added WORM capability and Fibre Channel information – Updated Ultrium Tape Drive features – Added information to Table 4. Command Timeout Values (Ultrium 1, 2 and 3 Full-Height) - Sorted by Circle v Chapter 3. Command Support – Standard Inquiry Data subsection: modified product revision level information. – Supported Vital Product Data Page subsection: additional information was added to the Bit next to Byte 9 in the Supported Vital Product Data Inquiry Page table. – Firmware Design subsection: corrected the format for cross-references. – Device Identification subsection: removed markers for external document version. – Mode Page 2 Fh, Behavior configuration Mode Page: added information from FCR 3139. – SET CAPACITY (not Ultrium 1) subsection: modified Minimum Capacity Proportion Values. v Chapter 4. Error Sense Information – Fencing Behavior subsection: modified to reflect updated Ultrium version information v Chapter 9. Attachment Features – Features of the Fibre Channel Interface subsection: added updated Ultrium information v FCR 3140 - LTO Crypto Diagnostics. Read This First v

v Updated Chapter 7 - Sense Keys and Additional Sense Tenth Edition, May 2008 Changes and additions to the following Chapters and subsections in the tenth edition are listed as follows: v FCR 3157: eServer information to be externalized v FCR 3142: LTO 4 Seven Speeds v FCR 3143: Read Buffer Main buffer Size Indication Eleventh Edition, April 2009 Information to update this edition was obtained from the following Functional Change Request documents (FCRs): v FCR 3148 - LTO SCSI Reference Corrections (MAM) v FCR 3167 - Persistent Reserve Out SCOPE field changes v FCR 3168 - LTO SCSI Reference corrections - Encryption v FCR 3169 - LTO SCSI Reference Corrections - WORM v FCR 3170 - LTO SCSI Reference Corrections - Sense v FCR 3171 - LTO SCSI Reference Corrections - Cmds vi IBM TotalStorage LTO Ultrium Tape Drive: SCSI Reference

Contents Read This First . . . . . . . . . . . iii Summary of Changes . . . . . Second Edition, April 2004 . . Third Edition, December 2004 . Fourth Edition, March 2005 . . Fifth Edition, May 2006 . . . Sixth Edition, December 2006 . Seventh Edition, June 2007 . . Eighth Edition, July 2007 . . . Ninth Edition, August/September Tenth Edition, May 2008 . . . Eleventh Edition, April 2009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii iii iii iv iv iv iv . . . . . . v 2007 . . . . v . . . . . . vi . . . . . . vi Tables . . . . . . . . . . . . . . . xi Preface . . . . . . . . . . . . . . xv Organization . . . Related Publications . . . . . . . . . . . . . . . . . . . . . xv . xv Chapter 1. Introduction . . . . . . . . 1 Supported Servers and Operating Primary Interface Attachment. Supported Device Drivers . . . Supported Tape Cartridges . . Systems . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 4 5 Chapter 2. Summary of Drive Generation Differences . . . . . . . . . . . . . 7 Differences in Command Timeout Values . . . Command and Parameter Differences Between Generations . . . . . . . . . . . . Data Changes Between Generations . . . . Standard Inquiry Data . . . . . . . . REPORT DENSITY SUPPORT Command . Mode Pages . . . . . . . . . . . READ POSITION Command . . . . . Request Sense Changes . . . . . . . Behavior Changes Between Generations . . . Cartridge Eject for Errors . . . . . . . Queueing Issues . . . . . . . . . . Microcode Detection of Errors . . . . . . Fencing Behavior . . . . . . . . . . . . . . . . . . . . . . . 8 . . . . . . . . . . . . 15 15 15 15 16 16 16 16 16 16 16 16 Chapter 3. Command Support . . . . . 17 ERASE . . . . . . . . . . . . . . . . INQUIRY . . . . . . . . . . . . . . . Standard Inquiry Data . . . . . . . . . . Supported Vital Product Data Page . . . . . Firmware Designation Page (03h) . . . . . . Mode Page Policy Page (87h) . . . . . . . SCSI Ports Page (88h) . . . . . . . . . . Sequential-Access Device Capabilities Page (B0h) Drive Serial Numbers (C1h) . . . . . . . . Device Unique Configuration Data Page (C7h) . Mode Parameter Default Settings Page (C8h) . . Copyright IBM Corp. 2002, 2009 20 21 22 28 29 30 33 35 36 37 38 Unit Serial Number Page (80h) . . . . . . . 39 Device Identification Page (83h) . . . . . . 40 Drive Component Revision Levels Pages (C0h) 45 LOAD/UNLOAD . . . . . . . . . . . . 46 LOCATE . . . . . . . . . . . . . . . 48 LOG SELECT. . . . . . . . . . . . . . 50 LOG SENSE . . . . . . . . . . . . . . 51 Log Page Format . . . . . . . . . . . 52 Log Page 00h: Supported Log Pages . . . . . 53 Log Page 02h: Write Error Counters . . . . . 56 Log Page 03h: Read Error Counters . . . . . 57 Log Page 06h: Non-Medium Errors (Not Ultrium 1 or Ultrium 2 non-RoHS) . . . . . . . . 58 Log Page 0Ch: Sequential Access Device Log . . 59 Log Page 11h: DT Device Status Log Page (Not Ultrium 1 or 2) . . . . . . . . . . . . 60 Log Page 14h: Device Statistics Log Page (Not Ultrium 1 or 2) . . . . . . . . . . . . 67 Log Page 16h: Tape Diagnostic Data Log Page (Not Ultrium 1 or 2) . . . . . . . . . . 69 Log Page 18h: Protocol-Specific Logical Unit Log Page . . . . . . . . . . . . . . . . 73 Log Page 2Eh: Tape Alert . . . . . . . . . 76 Log Page 30h: Tape Usage Log . . . . . . . 79 Log Page 31h: Tape Capacity Log . . . . . . 81 Log Page 32h: Data Compression Log . . . . 82 Log Page 33h: Write Errors (Not Ultrium 1 or Ultrium 2 non-RoHS) . . . . . . . . . . 83 Log Page 34h: Read Forward Errors (Not Ultrium 1 or Ultrium 2 non-RoHS) . . . . . . . . 85 Log Page 37h: Performance Characteristics (Ultrium 4) . . . . . . . . . . . . . 87 Log Page 38h: Blocks/Bytes Transferred (Not Ultrium 1 or Ultrium 2 non-RoHS) . . . . . 98 Log Page 39h: Host Port 0 Interface Errors (Not Ultrium 1 or Ultrium 2 non-RoHS) . . . . . 100 Log Page 3Ah: Drive Control Verification (Not in Ultrium 1) . . . . . . . . . . . . 101 Log Page 3Bh: Host Port 1 Interface Errors (Not Ultrium 1 or Ultrium 2 non-RoHS) . . . . . 102 Log Page 3Ch: Drive Usage Information . . . 103 Log Page 3Dh: Subsystem Statistics (Not Ultrium 1 or Ultrium 2 non-RoHS) . . . . . 104 Log Page 3Eh: Engineering Use (Not Ultrium 1 or Ultrium 2 non-RoHS) . . . . . . . . . 107 Log Page 3Eh[3Ch]: Drive Control Statistics (Not Ultrium 1 or Ultrium 2 non-RoHS) . . . 108 MODE SELECT . . . . . . . . . . . . 109 MODE SENSE . . . . . . . . . . . . . 110 Mode Data Format . . . . . . . . . . 112 Mode Parameter Header. . . . . . . . . 113 Mode Block Descriptor . . . . . . . . . 115 Mode Page 01h: Read-Write Error Recovery Page . . . . . . . . . . . . . . . 116 Mode Page 02h: Disconnect/Reconnect Page . . 118 Mode Page 0Ah: Control Extension Mode Page 120 vii

Mode Page 0Fh: Data Compression Mode Page Mode Page 10h: Sequential Access Device Configuration Page . . . . . . . . . . Mode Page 18h: Protocol-Specific Logical Unit Control Page . . . . . . . . . . . . Mode Page 19h: Protocol Specific Port Control Page . . . . . . . . . . . . . . . Mode Page 19h: Protocol Specific Port Control Page Short Format (Ultra 320 Attached Drives Only) . . . . . . . . . . . . . . . Mode Page 19h[03h]: Negotiated Settings Mode Subpage . . . . . . . . . . . . . . Mode Page 19h[04h]: Report Transfer Capabilities Mode Subpage. . . . . . . . Mode Page 1Ch: Information Exceptions Mode Page . . . . . . . . . . . . . . . Mode Page 1Dh: Medium Configuration Mode Page . . . . . . . . . . . . . . . Mode Page 24h: Vendor-Specific Control Mode Page . . . . . . . . . . . . . . . Mode Page 2Fh: Behavior Configuration Mode Page . . . . . . . . . . . . . . . Mode Page 3Dh: LEOT Mode Page (LTO 1 Only) . . . . . . . . . . . . . . . PERSISTENT RESERVE IN . . . . . . . . . PERSISTENT RESERVE OUT . . . . . . . . PREVENT/ALLOW MEDIUM REMOVAL . . . READ . . . . . . . . . . . . . . . . READ ATTRIBUTE . . . . . . . . . . . Vendor-Specific Medium Type Attributes . . . Format for the Attribute Values Service Action Format for the Attribute List Service Action . . Format for the Volume List Service Action. . . Format for the Partition List Service Action . . Medium Auxiliary Memory . . . . . . . READ BLOCK LIMITS . . . . . . . . . . READ BUFFER . . . . . . . . . . . . . Error Log Buffer (06h) . . . . . . . . . World Wide Name Buffer (08h) . . . . . . SCSI Log Buffer (07h) . . . . . . . . . READ POSITION . . . . . . . . . . . . RECEIVE DIAGNOSTIC RESULTS . . . . . . RELEASE UNIT . . . . . . . . . . . . REPORT DENSITY SUPPORT . . . . . . . . REPORT LUNs . . . . . . . . . . . . . REPORT SUPPORTED TASK MANAGEMENT FUNCTIONS (Not LTO1) . . . . . . . . . REPORT TIMESTAMP (Not LTO 1) . . . . . . REQUEST SENSE . . . . . . . . . . . . Sense Data Format . . . . . . . . . . RESERVE UNIT . . . . . . . . . . . . REWIND . . . . . . . . . . . . . . . SECURITY PROTOCOL IN (SPIN) A2h. . . . . Security Protocol In Pages (00h - Security Protocol Information). . . . . . . . . . SECURITY PROTOCOL OUT (SPOUT) B5h . . . Security Protocol Out Pages (20h - Tape Data Encryption Security Protocol) . . . . . . . SPOUT (20h:0010h) - Set Data Encryption . . . Key-Associated Data (KAD) Descriptors . . . SEND DIAGNOSTIC . . . . . . . . . . . viii 121 123 126 127 129 130 132 133 134 136 137 146 147 152 156 157 159 161 162 163 164 165 166 175 176 180 181 182 183 186 187 188 193 195 197 199 199 205 206 207 208 221 222 222 225 229 IBM TotalStorage LTO Ultrium Tape Drive: SCSI Reference SIM Data Structure . . . . . MIM Data Structure . . . . . Self-Test . . . . . . . . . Post A Self Test Diagnostic . . . Post B Performance Diagnostic . Post C Media Test Diagnostic . . Post D Head Test Diagnostic . . Primary Port Wrap Test Diagnostic Force Dump . . . . . . . . Write Dump To Cartridge . . . Write Dump to Flash (EEPROM) . Clear FLASH Dump (EEPROM) . Set Traps . . . . . . . . . Remove Traps . . . . . . . Reset Drive . . . . . . . . Read Thermal Sensor . . . . . SET CAPACITY (not Ultrium 1) . . SET TIMESTAMP (Not LTO 1). . . SPACE . . . . . . . . . . TEST UNIT READY . . . . . . VERIFY . . . . . . . . . . WRITE . . . . . . . . . . WRITE ATTRIBUTE . . . . . . WRITE BUFFER . . . . . . . WRITE FILE MARKS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 4. Error Sense Information Sense Data . . . . . Sense Data Management Unit Attention Conditions Persistent Errors . . . Fencing Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 233 236 237 238 240 241 242 243 244 246 247 248 249 251 251 254 256 258 260 261 262 263 264 266 267 267 267 267 268 268 Chapter 5. Implementation Considerations. . . . . . . . . . . 271 Device Clocks . . . . . . . . . . . . . 271 Chapter 6. WORM BEHAVIORS . . . . 273 Conditions for Writing . . . . . . . . . Command Behavior When WORM Medium Has Been Tampered With . . . . . . . . . . . 273 . 273 Chapter 7. Sense Keys and Additional Sense. . . . . . . . . . . . . . . 275 Sense Sense Sense Sense Sense Sense Sense Sense Sense Sense Sense Key Key Key Key Key Key Key Key Key Key Key 0 (No Sense) . . . . . . . 1 (Recovered Error). . . . . 2 (Not Ready) . . . . . . 3 (Medium Error) . . . . . 4 (Hardware or Firmware Error) 5 (Illegal Request) . . . . . 6 (Unit Attention) . . . . . 7 (Data Protect) . . . . . . 8 (Blank Check) . . . . . . B (Aborted Command) . . . D (Volume Overflow) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275 276 277 277 279 279 281 281 282 283 283 Chapter 8. Device Hardware Encryption (Ultrium 4) . . . . . . . 285

Chapter 9. Attachment Features . . . 287 Types of Interface Attachments . . . . . . . Common Tape LUN Behaviors . . . . . . . Power-On . . . . . . . . . . . . . Reset Strategy . . . . . . . . . . . . Abort Handling . . . . . . . . . . . Multi-initiator Support . . . . . . . . . Status Codes . . . . . . . . . . . . Features of the SCSI Interface . . . . . . . . LUN Identification . . . . . . . . . . SPI Information Unit (Ultra 320 Attached Drives Only) . . . . . . . . . . . . . . . Bus Parity Errors (When Using Data Group Transfers). . . . . . . . . . . . . . Bus Parity Errors (When Using Information Unit Transfers). . . . . . . . . . . . . . Disconnect Strategy . . . . . . . . . . Messages . . . . . . . . . . . . . . Features of the Fibre Channel Interface . . . . . Features of the Serial Attached SCSI (SAS) Interface 287 287 287 287 288 290 290 291 291 291 291 292 292 293 297 297 Chapter 10. Firmware Download . . . 299 Identifying Level Hardware of Drive (Not Ultrium 1) . . . . . . . . . . . . . . . . . 299 Identifying the Level Hardware for Which the Firmware Image is Intended (Not Ultrium 1) . . . 301 Download Process . . . . . . . . . . . 301 Appendix A. ASN.1 Information (Used for Encryption). . . . . . . . . . . 303 ASN.1 [DER] Encoding Implementation . . . SEDK ASN.1 Format . . . . . . . . . . ASN.1 Standalone SEDK (SEDK Only, Clear, Signed) - Example . . . . . . . . . . . ASN.1 Standalone SEDK (SEDK Only, dSK Encrypted, Signed) - Example . . . . . . . xAK/xSK ASN.1 Format . . . . . . . . ASN.1 xAK/xSK Structure (Clear, Signed) Example . . . . . . . . . . . . . . Signing ASN.1 Format . . . . . . . . . ASN.1 Signing Information (Clear, Unsigned) Example . . . . . . . . . . . . . . ASN.1 Signing Information (eAK Encrypted, dAK Signed) - Example . . . . . . . . . . . HMAC ASN.1 Format . . . . . . . . . ASN.1 HMAC Structure - Example . . . . . . 303 . 303 . 304 . 305 . 306 . 307 . 308 . 309 . 309 . 310 . 310 Appendix B. Notices . . . . . . . . 313 Trademarks . . . . . . . . . . . . . . 313 Glossary . . . . . . . . . . . . . 315 Index . . . . . . . . . . . . . . . 323 Contents ix

x IBM TotalStorage LTO Ultrium Tape Drive: SCSI Reference

Tables 1. Features of the IBM Ultrium Tape Drives and the IBM 3580 Ultrium Tape Drive . . . . . 2 2. Supported Servers and Operating Systems for Primary Interface Attachment . . . . . . . 3 3. IBM LTO Ultrium Tape Drive Support of LTO Cartridges . . . . . . . . . . . . . 5 4. Command Timeout Values (Ultrium 1, 2, and 3 Full-Height) - Sorted by OpCode . . . . . . 8 5. Command Timeout Values (Ultrium 3 Half-Height and Ultrium 4) - Sorted by OpCode. . . . . . . . . . . . . . 10 6. Command Timeout Values (Ultrium 3 Half-Height and Ultrium 4) - Alphabetical . . 12 7. Command and Parameter differences between generations . . . . . . . . . . . . 15 8. Supported Common SCSI Commands. . . . 17 9. ERASE Command . . . . . . . . . . 20 10. INQUIRY Command . . . . . . . . . 21 11. Standard Inquiry Data Valid LUN . . . . . 22 12. Standard Inquiry Data Valid LUN (Drive configured with eServer attachment feature) . 24 13. Product Identification Table . . . . . . . 26 14. Supported Vital Product Data Inquiry Page 28 15. Firmware Designation Page . . . . . . . 29 16. Mode Page Policy page . . . . . . . . 30 17. Mode Page policy descriptor . . . . . . . 30 18. Mode page policy values . . . . . . . . 31 19. Mode Page Policy for LUN 0 (SSC Device) 31 20. Mode Page Policy LUN 2 (ADC Device) 31 21. SCSI Ports Inquiry Page . . . . . . . . 33 22. SCSI Port Identification Descriptor . . . . . 34 23. Target Port Descriptor Format . . . . . . 34 24. Sequential-Access Device Capabilities Page 35 25. Inquiry Page C1h: Drive Serial Numbers 36 26. Unit Serial Number Inquiry Page . . . . . 39 27. Device Identification Inquiry Page . . . . . 40 28. Device Identification Descriptor Format 40 29. Identifier Format . . . . . . . . . . . 41 30. Protocol Identification descriptor . . . . . 41 31. Logical Unit (NAA) Descriptor Format 42 32. Port Identifier Descriptor Format . . . . . 42 33. Relative Target Port Values . . . . . . . 42 34. Port Name (NAA) Descriptor Format . . . . 43 35. Target Device Name Descriptor . . . . . . 44 36. Drive Component Revision Levels Pages 45 37. LOAD/UNLOAD Command . . . . . . 46 38. LOAD/UNLOAD actions depending on Load and Hold bit settings and medium position . . 47 39. LOCATE (10) command . . . . . . . . 48 40. LOCATE (16) Command (Ultrium 4 and Later) 48 41. Dest Type field definitions . . . . . . . 49 42. LOG SELECT Command . . . . . . . . 50 43. LOG SENSE Command . . . . . . . . 51 44. Log Page Header Format . . . . . . . . 52 45. Log Parameter Format . . . . . . . . . 52 46. Supported Log Pages Log Page Definition 53 Copyright IBM Corp. 2002, 2009 47. Supported Log Pages Log Page Format (Ultrium 1 and Ultrium 2 non-RoHS) . . . . 53 48. Supported Log Pages Log Page Format (Ultrium 2 RoHS and Ultrium 3) . . . . . 53 49. Supported Log Pages Log Page Format (Ultrium 4). . . . . . . . . . . . . 54 50. Write Error Log Parameters . . . . . . . 56 51. Read Error Log Parameters . . . . . . . 57 52. Non-Medium Errors log parameter codes 58 53. Sequential Access Device Log Parameters 59 54. DT Device Status Log Page . . . . . . . 60 55. DT Device Status log page parameter codes 60 56. Very high frequency data log parameter format 60 57. VHF DATA DESCRIPTOR field . . . . . . 61 58. DT DEVICE ACTIVITY field values . . . . 63 59. Very high frequency polling delay log parameter format . . . . . . . . . . 64 60. Primary Port Status descriptor . . . . . . 64 61. Speed Values . . . . . . . . . . . . 66 62. Device Statistics log parameter codes . . . . 67 63. Medium Type Log Parameter format . . . . 67 64. Medium Type log parameter . . . . . . . 68 65. Tape Diagnostic Data log page . . . . . . 69 66. Tape Diagnostic Data log parameter format 70 67. Protocol-Specific log page for SAS . . . . . 73 68. Protocol-Specific log parameter for SAS 74 69. SAS Phy log descriptor. . . . . . . . . 75 70. TapeAlert Log Parameters. . . . . . . . 76 71. Tape Usage Log Parameters . . . . . . . 79 72. Tape Capacity Log Parameters . . . . . . 81 73. Data Compression Log Parameters . . . . . 82 74. Write Errors log parameter codes . . . . . 83 75. Read Forward Error Counters log parameter codes . . . . . . . . . . . . . . 85 76. Log Page 37h: Performance Characteristics: Quality Summary . . . . . . . . . . 89 77. Log Page 37h: Performance Characteristics: Device Usage . . . . . . . . . . . . 89 78. Log Page 37h: Performance Characteristics: Host Commands . . . . . . . . . . . 90 79. Log Page 37h: Performance Characteristics: Host Initiators . . . . . . . . . . . 93 80. Log Page 37h: Performance Characteristics: Host Recovery (by port) . . . . . . . . 93 81. Log Page 37h: Performance Characteristics: Mode Phase Timing Windows . . . . . . 93 82. Log Page 37h: Performance Characteristics: Servo Speed Characteristics . . . . . . . 96 83. Log Page 37h: Performance Characteristics: Static Capacity . . . . . . . . . . . 96 84. Log Page 37h: Performance Characteristics: Active Capacity . . . . . . . . . . . 96 85. Blocks/Bytes Transferred log parameter codes 98 86. Host Port Interface log parameter codes 100 87. Subsystem Statistics log parameter codes 104 88. 6-Byte MODE SELECT Command . . . . 109 xi

89. 90. 91. 92. 93. 94. 95. 96. 97. 98. 99. 100. 101. 102. 103. 104. 105. 106. 107. 108. 109. 110. 111. 112. 113. 114. 115. 116. 117. 118. 119. 120. 121. 122. 123. 124. 125. 126. 127. 128. 129. 130. 131. 132. 133. 134. 135. 136. 137. xii 10-Byte MODE SELECT Command . . . . 6-Byte MODE SENSE Command . . . . . 10-Byte MODE SENSE Command . . . . . Mode Data Format . . . . . . . . . . Mode Parameter Header 6-Byte Command Mode Parameter Header 10-Byte Command Media Type Values . . . . . . . . . . Mode Block Descriptor . . . . . . . . Read-Write Error Recovery Page . . . . . Read Retry Limit Definition . . . . . . . Write Retry Limit Definition . . . . . . Disconnect/Reconnect Mode Page . . . . Control Extension Mode Page . . . . . . Data Compression Mode Page . . . . . . Responses to Data Boundaries . . . . . . Sequential Access Device Configuration Page WTRE Definition . . . . . . . . . . Fibre Channel Logical Unit Control Page SAS Logical Unit Control Page. . . . . . Fibre Channel Port Control Page . . . . . SAS Port Control Page . . . . . . . . Protocol Specific Port Control Page short format (U320 only). . . . . . . . . . Negotiated Settings mode subpage (U320 drives only) . . . . . . . . . . . . Transfer Period Factor . . . . . . . . Transfer Width Exponent. . . . . . . . Report Transfer Capabilities mode subpage (U320 drives only) . . . . . . . . . . Information Exceptions Mode Page . . . . Medium Configuration Mode Page . . . . Worm Mode Label Restrictions field values Worm Mode Filemarks Restrictions field values . . . . . . . . . . . . . . Vendor-Specific Control Mode Page . . . . Behavior Configuration Mode Page . . . . Fence Behavior Selection Values . . . . . Periodic Clean Notification Usage Criteria WORM Behavior . . . . . . . . . . Sense Data Behavior . . . . . . . . . Unload On Error Behavior Definition LEOT Mode Page (Ultrium 1 Only) . . . . PERSISTENT RESERVE IN Command PERSISTENT RESERVE IN Parameter Data for Read Capabilities . . . . . . . . . PERSISTENT RESERVE IN Parameter Data for Read Full Status . . . . . . . . . PERSISTENT RESERVE IN Full Status descriptor format . . . . . . . . . . PERSISTENT RESERVE IN Parameter Data for Read Keys . . . . . . . . . . . PERSISTENT RESERVE IN Parameter Data for Read Reservations. . . . . . . . . PERSISTENT RESERVE IN Read Reservations Descriptor . . . . . . . . . . . . PERSISTENT RESERVE OUT Command Values for Service Action Codes in PERSISTENT RESERVE OUT Command . . Persistent Reservation Type Codes . . . . PERSISTENT RESERVE OUT Parameter List 109 110 110 112 113 113 113 115 116 116 117 118 120 121 122 123 124 126 126 127 128 129 130 131 131 132 133 134 134 135 136 137 138 140 141 142 145 146 147 147 148 149 149 150 150 152 152 153 154 IBM TotalStorage LTO Ultrium Tape Drive: SCSI Reference 138. PERSISTENT RESERVE OUT command with REGISTER AND MOVE service action parameter list . . . . . . . . . . . 139. PREVENT/ALLOW MEDIUM REMOVAL Command . . . . . . . . . . . . 140. READ Command . . . . . . . . . . 141. READ ATTRIBUTE Command . . . . . . 142. Supported Service Action Codes . . . . . 143. Vendor-Specific Medium Type Attributes 144. Parameter Data for an Attribute Values Service Action . . . . . . . . . . . 145. Parameter Data for an Attribute List Service Action . . . . . . . . . . . . . . 146. Parameter Data for a Volume List Service Action . . . . . . . . . . . . . . 147. Parameter Data for a Partition List Service Action . . . . . . . . . . . . . . 148. Types of MAM Attributes . . . . . . . 149. States for the Types of MAM Attributes 150. Format of a MAM Attribute. . . . . . . 151. Values and Requirements for the Format Field 152. Range of Values for MAM Attribute Identifiers. . . . . . . . . . . . . 153. Standard Device Type Attributes . . . . . 154. Format for Device Vendor Identification/Product Serial Number Attribute, Device Vendor Identification/Product Serial Number at Load-1 Attribute, Device Vendor Identification/Product Serial Number at Load-2 Attribute, and Device Vendor Identification/Product Serial Number at Load-3 Attribute . . . . . . . . . . 155. Standard Medium Type Attributes . . . . 156. Values for Medium Type and Medium Type Information Attributes . . . . . . . . 157. Standard Host Type Attributes . . . . . . 158. Values for the Text Localization Identifier Attribute . . . . . . . . . . . . . 159. Vendor-Specific Medium Type Attributes 160. READ BLOCK LIMITS Command . . . . 161. READ BLOCK LIMITS Descriptor . . . . 162. READ BUFFER Command . . . . . . . 163. Description of the Mode Field . . . . . . 164. Main Data Buffer Offset Boundary Interpretation . . . . . . . . . . . 165. READ BUFFER Header . . . . . . . . 166. READ BUFFER Descriptor . . . . . . . 167. READ ECHO BUFFER Descriptor. . . . . 168. Drive Buffers . . . . . . . . . . . 169. Error Log Buffer . . . . . . . . . . 170. World Wide Name Buffer . . . . . . . 171. Error Log Buffer Command . . . . . . . 172. READ POSITI

This is the eleventh edition of the IBM TotalStorage LTO Ultrium Tape Drive SCSI Reference (April 2009). Summary of Changes Second Edition, April 2004 The following changes were made in this edition: v Added features of the 3580 Tape Drive Models L23 and H23. v Modified to show that the generation 2 drive code ignores the Page Control (PC) field.

Related Documents:

The LTFS software for LTO-5/LTO-6 Tandberg stand-alone or internal tape drives may be downloaded from the Tandberg Data Website. This article will cover basic LTFS integration using Tandberg Data LTO-5/LTO-6 tape drives in Windows 2012 Server. Tandberg LTO-5/LTO-6 tape drives also support LTFS with Windows 8/10, MAC and Linux. Prerequisites

Ultrium LTO logo. See Table 3-1 on page 3-2 for more information. v Will interchange tapes with other LTO tape drives that bear the official Ultrium LTO logo v Support for WORM (Write Once Read Many) using WORM media v Data encryption capability using LTO Ultrium 4, 5 and 6 media

Fujitsu Device Drive Model . ETERNUS LT140 LTO-6 / LTO-7 / LTO-8 HH SAS, FC ETERNUS LT260 LTO-5 / LTO-6 / LTO-7 / LTO-8 HH SAS, FC FSC FibreCAT TX08 HP Ultrium 4-SCSI HPE Device Drive Model HPE StoreEver* ESL G3 * former name - StorageWorks . and secure access solutions. Powered by the AnyData Engine and set apart by its image technology .

diagnostics, and performance optimization. Included with the HP E LTO Ultrium tape drives is the option to download Yosemite Server Backup Basic backup and recovery software providing a backup application to p rotect a single server. If data is critical to your business, protect it with an HP E LTO Ultrium tape drive.

DAT 24 DAT 40 SDLT 320 E N T R Y - L E V E L H I G H - E N D M I D - R A N G E DAT 72 Ultrium 232 Ultrium 460 Ultrium 960 DLT VS160 Ultrium 448 SDLT 600 DLT VS80 May 17, 2006 26 HP StorageWorks standalone tape drives Ultrium For those looking for the best performance, reliability, and i

LTO Generations LTO-5 LTO-6 LTO-7 LTO-8 LTO-9 New Format Capacity (Native) 1.5 TB (L5) 2.5 TB (L6) 6 TB (L7) 12.0 TB Up to 25 TB (L9) Other Format Capacities (Native) 800 GB (L4) (400 GB L3 R/O)

IBM System Storage N series IBM DB2 Records Manager IBM TotalStorage DS4000 with SATA disks IBM System Storage DR550 IBM TotalStorage Tape (including WORM) products For details on these products, see Chapter 4, “IBM Tivoli Storage Manager and IBM System Storage Archive Manager” on page 73. 1.4.3 Data lifecycle management At its core, the .