PREPARE SUBSTRATE AS REQUIRED PRIOR TO APPLICATION OF AC PRIMER AND AC FAST FR (1) PLY FIRESTONE PMMA MEMBRANE FLASHING EXTEND 12" (305 mm) MIN. HORIZONTALLY ONTO FIRESTONE MODIFIED BITUMEN ROOF MEMBRANE. NOTE: 1. REFER TO FIRESTONE WEBSITE FOR MOST CURRENT INFORMATION. 2. AC PRIMER AND AC FAST FR ARE FOR USE ON MODIFIED BITUMEN SYSTEMS ONLY. DO NOT USE ON TPO OR EPDM. 3. THE TERM "FIRESTONE PMMA MEMBRANE" REFERS TO THE COMPLETED AND PROPERLY INSTALLED MONOLITHIC MEMBRANE CONSISTING OF FIRESTONE AC FAST FR AND AC FLEECE 120. CONTINUOUS BEAD OF FIRESTONE AP SEALANT REQUIRED IF GAP BETWEEN EDGE OF MODIFIED MEMBRANE & WALL GREATER THAN 1/16" (1.6 mm) (TYP.) 8" (203 mm) MIN. ASSURE FULL CONTACT OF BOTH LAYERS W/ SUBSTRATE & FULL SATURATION OF AC FLEECE 120 CONTINUOUS 4" (102 mm) WIDE STRIP OF FIRESTONE PMMA MEMBRANE @ WALL TO DECK TRANSITION. 2" (51 mm) 6" (152 mm) MIN. 2" (51 mm) FIRESTONE BASE SHEET FIRESTONE CAP SHEET APPROVED SUBSTRATE MAXIMUM WARRANTY: 20 YEARS PMMA BASE FLASHING PMMA Firestone Building Products Sales: (800- 428-4442 ACCEPTABLE SYSTEMS: Technical (800) 428-4511 MODIFIED BITUMEN www.firestonebpco.com ISSUE / REVISION DATE: DETAIL NO. 4/22/2019 PMMA-1 NOT TO SCALE

CUT-IN REGLET 1" (25 mm) MIN. DEEP, APPLY FIRESTONE AP SEALANT AS REQUIRED. 30-45 PREPARE SUBSTRATE AS REQUIRED PRIOR TO APPLICATION OF AC PRIMER & AC FAST FR (1) PLY FIRESTONE PMMA MEMBRANE FLASHING EXTEND 12" (305 mm) MIN. HORIZONTALLY ONTO FIRESTONE MODIFIED BITUMEN ROOF MEMBRANE. NOTE: 1. REFER TO FIRESTONE WEBSITE FOR MOST CURRENT INFORMATION. 2. AC PRIMER AND AC FAST FR ARE FOR USE ON MODIFIED BITUMEN SYSTEMS ONLY. DO NOT USE ON TPO OR EPDM. 3. THE TERM "FIRESTONE PMMA MEMBRANE" REFERS TO THE COMPLETED AND PROPERLY INSTALLED MONOLITHIC MEMBRANE CONSISTING OF AC FAST FR AND AC FIRESTONE FLEECE 120. 8" (203 mm) MIN. CONTINUOUS BEAD OF FIRESTONE AP SEALANT REQUIRED IF GAP BETWEEN EDGE OF MODIFIED MEMBRANE & WALL GREATER THAN 1/16" (1.6 mm) (TYP.) ASSURE FULL CONTACT OF BOTH LAYERS W/ SUBSTRATE & RESIN SATURATION OF FLEECE. 2" (51 mm) CONTINUOUS 4" (102 mm) WIDE STRIP OF FIRESTONE PMMA MEMBRANE @ WALL TO DECK TRANSITION 6" (152 mm) MIN. 2" (51 mm) FIRESTONE BASE SHEET FIRESTONE CAP SHEET APPROVED SUBSTRATE BASE FLASHING WITH REGLET PMMA Firestone Building Products Sales: (800- 428-4442 ACCEPTABLE SYSTEMS: Technical (800) 428-4511 MODIFIED BITUMEN www.firestonebpco.com MAXIMUM WARRANTY: 20 YEARS ISSUE / REVISION DATE: DETAIL NO. 4/22/2019 PMMA-2 NOT TO SCALE

NOTE: 1. REFER TO FIRESTONE WEBSITE FOR MOST CURRENT INFORMATION. 2. AC PRIMER AND AC FAST FR ARE FOR USE ON MODIFIED BITUMEN SYSTEMS ONLY. DO NOT USE ON TPO OR EPDM. 3. THE TERM "FIRESTONE PMMA MEMBRANE" REFERS TO THE COMPLETED AND PROPERLY INSTALLED MONOLITHIC MEMBRANE CONSISTING OF AC FAST FR AND AC FLEECE 120. FIRESTONE AP SEALANT COUNTERFLASHING AS REQUIRED PREPARE SUBSTRATE AS REQUIRED PRIOR TO APPLICATION OF AC PRIMER AND AC FAST FR 8" (203 mm) MIN. FIRESTONE PMMA MEMBRANE FLASHING EXTENDS 12" (305 MM) MIN. HORIZONTALLY ONTO MODIFIED BITUMEN ROOF MEMBRANE CONTINUOUS BEAD OF FIRESTONE AP SEALANT REQUIRED IF GAP BETWEEN EDGE OF MODIFIED MEMBRANE & WALL GREATER THAN 1/16" (1.6 mm) (TYP.) ASSURE FULL CONTACT OF BOTH LAYERS W/ SUBSTRATE & FULL SATURATION OF AC FLEECE 120 2" (51 mm) CONTINUOUS 4" (102 mm) WIDE STRIP OF FIRESTONE PMMA MEMBRANE @ WALL TO DECK TRANSITION 6" (152 mm) MIN. 2" (51 mm) FIRESTONE BASE SHEET FIRESTONE CAP SHEET APPROVED SUBSTRATE MAXIMUM WARRANTY: 20 YEARS BASE FLASHING WITH COUNTERFLASHING PMMA Firestone Building Products Sales: (800- 428-4442 ACCEPTABLE SYSTEMS: Technical (800) 428-4511 MODIFIED BITUMEN www.firestonebpco.com ISSUE / REVISION DATE: DETAIL NO. 4/24/2019 PMMA-3 NOT TO SCALE

APPLY AC PRIMER & EXTEND 1/2" (13 mm) MIN. BEYOND LINE OF PMMA FLASHING POWER TOOL CLEAN PIPE NOTE: 1. REFER TO FIRESTONE WEBSITE FOR CURRENT INFORMATION. 2. AC PRIMER AND AC FAST FR ARE FOR USE ON MODIFIED BITUMEN SYSTEMS ONLY. DO NOT USE ON TPO OR EPDM. 3. THE TERM "FIRESTONE PMMA MEMBRANE" REFERS TO THE COMPLETED AND PROPERLY INSTALLED MONOLITHIC MEMBRANE CONSISTING OF AC FAST FR AND AC FLEECE 120. 8" (203 mm) MIN. FIRESTONE PMMA MEMBRANE SKIRT WRAPPED AROUND PIPE W/ 2" (51 mm) MIN. OVERLAP FIRESTONE PMMA MEMBRANE COLLAR CUT INSIDE DIA. 1/2" (13 mm) SMALLER THAN PIPE DIAMETER FIRESTONE CAP SHEET 6" (152 mm) MIN. RADIAL CUTS TO SKIRT AS REQUIRED FIRESTONE BASE SHEET APPROVED SUBSTRATE MAXIMUM WARRANTY: 20 YEARS PIPE FLASHING PMMA Firestone Building Products Sales: (800- 428-4442 ACCEPTABLE SYSTEMS: Technical (800) 428-4511 MODIFIED BITUMEN www.firestonebpco.com ISSUE / REVISION DATE: DETAIL NO. 3/28/2019 PMMA-4 NOT TO SCALE

2" (51 mm) ONE OR TWO PLY FIRESTONE PMMA MEMBRANE WALL FLASHING BEYOND PRIME SCUPPER FRAME PRIOR TO AC PRIMER AND AC FAST FR MEMBRANE APPLICATION 8" (203 mm) MINIMUM PREPARE SUBSTRATE AS REQUIRED PRIOR TO AC PRIMER AND AC FAST FR MEMBRANE APPLICATION NOTE: 1. REFER TO FIRESTONE WEBSITE FOR CURRENT INFORMATION. 2. AC PRIMER AND AC FAST FR ARE FOR USE ON MODIFIED BITUMEN SYSTEMS ONLY. DO NOT USE ON TPO OR EPDM. 3. THE TERM "FIRESTONE PMMA MEMBRANE" REFERS TO THE COMPLETED AND PROPERLY INSTALLED MONOLITHIC MEMBRANE CONSISTING OF FIRESTONE AC FAST FR AND AC FLEECE 120. STRAINER AND CLAMP RING ASSURE FULL CONTACT OF BOTH LAYERS W/ SUBSTRATE & FULL SATURATION OF AC FLEECE 120 AC FAST FR AND SAND FILL AS REQUIRED TO DEVELOP SMOOTH TRANSITION 6" (152 mm) MIN. OVERLAP FIRESTONE BASE SHEET FIRESTONE CAP SHEET SCUPPER DRAIN ASSEMBLY APPROVED SUBSTRATE SCUPPER DRAIN FLASHING PMMA Firestone Building Products Sales: (800- 428-4442 ACCEPTABLE SYSTEMS: Technical (800) 428-4511 MODIFIED BITUMEN www.firestonebpco.com MAXIMUM WARRANTY: 20 YEARS ISSUE / REVISION DATE: DETAIL NO. 4/24/2019 PMMA-5 NOT TO SCALE

NOTE: 1. REFER TO FIRESTONE WEBSITE FOR CURRENT INFORMATION. 2. AC PRIMER AND AC FAST FR ARE FOR USE ON MODIFIED BITUMEN SYSTEMS ONLY. DO NOT USE ON TPO OR EPDM. 3. THE TERM "FIRESTONE PMMA MEMBRANE" REFERS TO THE COMPLETED AND PROPERLY INSTALLED MONOLITHIC MEMBRANE CONSISTING OF FIRESTONE AC FAST FR AND AC FLEECE 120. FIRESTONE AP SEALANT COUNTERFLASHING AS REQUIRED PREPARE SUBSTRATE AS REQUIRED PRIOR TO APPLICATION OF AC PRIMER AND AC FAST FR PRIME ANY SCUPPER FRAMEWORK PRIOR TO APPLICATION OF AC PRIMER AND AC FAST FR (1) PLY AC FAST FR MEMBRANE FLASHING EXTEND 12" (305 mm) MIN. HORIZONTALLY ONTO FIRESTONE MODIFIED BITUMEN ROOF MEMBRANE CONT. BEAD OF FIRESTONE AP SEALANT REQUIRED IF GAP BETWEEN EDGE OF MODIFIED MEMBRANE & WALL GREATER THAN 1/16" (1.6 mm) (TYP.) ASSURE FULL CONTACT OF BOTH LAYERS W/ SUBSTRATE & FULL SATURATION OF AC FLEECE 120 CONTINUOUS 4" (102 mm) WIDE STRIP OF AC FAST FR MEMBRANE @ WALL TO DECK TRANSITION FIRESTONE CAP SHEET FIRESTONE BASE SHEET 12" (305 mm) MIN. 6" (152 mm) 6" (152 mm) THROUGH-WALL SCUPPER FLASHING PMMA Firestone Building Products Sales: (800- 428-4442 ACCEPTABLE SYSTEMS: Technical (800) 428-4511 MODIFIED BITUMEN www.firestonebpco.com MAXIMUM WARRANTY: 20 YEARS ISSUE / REVISION DATE: DETAIL NO. 4/25/2019 PMMA-6 NOT TO SCALE

NOTE: 1. REFER TO FIRESTONE WEBSITE FOR CURRENT INFORMATION. 2. AC PRIMER AND AC FAST FR ARE FOR USE ON MODIFIED BITUMEN SYSTEMS ONLY. DO NOT USE ON TPO OR EPDM. 3. THE TERM "FIRESTONE PMMA MEMBRANE" REFERS TO THE COMPLETED AND PROPERLY INSTALLED MONOLITHIC MEMBRANE CONSISTING OF FIRESTONE AC FAST FR AND AC FLEECE 120. (2) PLY FIRESTONE PMMA MEMBRANE FLASHING - EXTEND TOP 8" (203 mm) PLY 4" (102 mm) MIN ONTO BOTTOM PLY. EXTENDS 12" (305 mm) MIN ONTO MOD BIT MEMBRANE FASTENERS 4" (102 mm) O.C., STAGGERED 1" (25 mm) FIRESTONE CAP SHEET 1/4" (6 mm) HEM 6" (152 mm) MIN. 4" (102 mm) MIN. APPROVED SUBSTRATE FIRESTONE BASE SHEET SET METAL DRIP EDGE - ROUGH UP FOR MECHANICAL BOND PRIME FLANGE W/ AC PRIMER CONTINUOUS CLEAT, FASTENED 6" (152 mm) O.C. (MAX.) MAXIMUM WARRANTY: 20 YEARS DRIP EDGE FLASHING PMMA Firestone Building Products Sales: (800- 428-4442 ACCEPTABLE SYSTEMS: Technical (800) 428-4511 MODIFIED BITUMEN www.firestonebpco.com ISSUE / REVISION DATE: DETAIL NO. 4/25/2019 PMMA-7 NOT TO SCALE

NOTE: 1. REFER TO FIRESTONE WEBSITE FOR MOST CURRENT INFORMATION. 2. FIRESTONE AC PRIMER AND AC FAST FR ARE FOR USE ON MODIFIED BITUMEN SYSTEMS ONLY. DO NOT USE ON TPO OR EPDM. 3. THE TERM "FIRESTONE PMMA MEMBRANE" REFERS TO THE COMPLETED AND PROPERLY INSTALLED MONOLITHIC MEMBRANE CONSISTING OF FIRESTONE AC FAST FR AND AC FLEECE 120. MAXIMUM WARRANTY: 20 YEARS OUTSIDE CORNER PMMA Firestone Building Products Sales: (800- 428-4442 ACCEPTABLE SYSTEMS: Technical (800) 428-4511 MODIFIED BITUMEN www.firestonebpco.com ISSUE / REVISION DATE: DETAIL NO. 4/25/2019 PMMA-8 NOT TO SCALE

NOTE: 1. REFER TO FIRESTONE WEBSITE FOR CURRENT INFORMATION. 2. AC PRIMER AND AC FAST FR ARE FOR USE ON MODIFIED BITUMEN SYSTEMS ONLY. DO NOT USE ON TPO OR EPDM. 3. THE TERM "FIRESTONE PMMA MEMBRANE" REFERS TO THE COMPLETED AND PROPERLY INSTALLED MONOLITHIC MEMBRANE CONSISTING OF FIRESTONE AC FAST FR AND AC FLEECE 120. FIRESTONE PMMA MEMBRANE FLASHING INSIDE CORNER HANDCUT FROM AC FLEECE 120 DEFORM TO PROVIDE 1" (25 mm) MINIMUM UP TURN 6" (152 mm) MAXIMUM WARRANTY: 20 YEARS INSIDE CORNER PMMA Firestone Building Products Sales: (800- 428-4442 ACCEPTABLE SYSTEMS: Technical (800) 428-4511 MODIFIED BITUMEN www.firestonebpco.com ISSUE / REVISION DATE: DETAIL NO. 4/25/2019 PMMA-9 NOT TO SCALE

FIRESTONE AP SEALANT UNIT COUNTERFLASHING (EXISTING) 3" (76 mm) COUNTER-FLASHING EXTENDER-FASTEN 12" (305 mm) O.C. WITH FIRESTONE FASTENER & SEALING WASHER PREPARE SUBSTRATE AS REQUIRED PRIOR TO APPLICATION OF AC PRIMER & AC FAST FR NOTE: 1. REFER TO FIRESTONE WEBSITE FOR CURRENT INFORMATION. 2. AC PRIMER AND AC FAST FR ARE FOR USE ON MODIFIED BITUMEN SYSTEMS ONLY. DO NOT USE ON TPO OR EPDM. 3. THE TERM "FIRESTONE PMMA MEMBRANE" REFERS TO THE COMPLETED AND PROPERLY INSTALLED MONOLITHIC MEMBRANE CONSISTING OF FIRESTONE AC FAST FR AND AC FLEECE 120. (1) PLY FIRESTONE PMMA MEMBRANE FLASHING EXTEND 12" (305 MM) MIN. HORIZONTALLY ONTO FIRESTONE MODIFIED BITUMEN ROOF MEMBRANE CONTINUOUS BEAD OF FIRESTONE AP SEALANT REQUIRED IF GAP BETWEEN EDGE OF MODIFIED MEMBRANE & WALL GREATER THAN 1/16" (1.6 mm) (TYP.) 8" (203 mm) MIN. ASSURE FULL CONTACT OF BOTH LAYERS W/ SUBSTRATE & FULL SATURATION OF AC FLEECE 120 CONTINUOUS 4" (102 mm) WIDE STRIP OF FIRESTONE PMMA MEMBRANE AT WALL TO DECK TRANSITION FIRESTONE MODIFIED BITUMEN CAP SHEET 2" (51 mm) FIRESTONE MODIFIED BITUMEN BASE SHEET 6" (152 mm) MIN. 2" (51 mm) APPROVED SUBSTRATE MAXIMUM WARRANTY: 20 YEARS CURB FLASHING PMMA Firestone Building Products Sales: (800- 428-4442 ACCEPTABLE SYSTEMS: Technical (800) 428-4511 MODIFIED BITUMEN www.firestonebpco.com ISSUE / REVISION DATE: DETAIL NO. 4/25/2019 PMMA-10 NOT TO SCALE

UNI-STRUT CHANNEL OR SIMILAR FIRESTONE PMMA MEMBRANE COLLAR CUT SNUG FIT AROUND PENETRATION TO PROVIDE 1" (25 mm) MIN. VERTICAL TURN UP NOTE: 1. REFER TO FIRESTONE WEBSITE FOR CURRENT INFORMATION. 2. AC PRIMER AND AC FAST FR ARE FOR USE ON MODIFIED BITUMEN SYSTEMS ONLY. DO NOT USE ON TPO OR EPDM. 3. THE TERM "FIRESTONE PMMA MEMBRANE" REFERS TO THE COMPLETED AND PROPERLY INSTALLED MONOLITHIC MEMBRANE CONSISTING OF AC FAST FR AND AC FLEECE 120. MIXOF DRY SAND AND AC PRIMER - FILL IN CHANNEL TO TOP OF FIRESTONE PMMA MEMBRANE SKIRT - SLOPE TO DRAIN FIRESTONE MODIFIED BITUMEN CAP SHEET ON TOP OF FIRESTONE MODIFIED BITUMEN BASE SHEET 6" (152 mm) (TYP.) FIRESTONE FLEECE 120 FLAP FIRESTONE PMMA MEMBRANE SKIRT WRAPPED AROUND METAL PENETRATION W/2" (51 mm) MIN. OVERLAP @ ALL JOINTS MAXIMUM WARRANTY: 20 YEARS IRREGULAR PENETRATION SUCH AS UNISTRUT PMMA Firestone Building Products Sales: (800- 428-4442 ACCEPTABLE SYSTEMS: Technical (800) 428-4511 MODIFIED BITUMEN www.firestonebpco.com ISSUE / REVISION DATE: DETAIL NO. 4/25/2019 PMMA-11 NOT TO SCALE

NOTE: 1. REFER TO FIRESTONE WEBSITE FOR CURRENT INFORMATION. 2. AC PRIMER AND AC FAST FR ARE FOR USE ON MODIFIED BITUMEN SYSTEMS ONLY. DO NOT USE ON TPO OR EPDM. 3. THE TERM "FIRESTONE PMMA MEMBRANE" REFERS TO THE COMPLETED AND PROPERLY INSTALLED MONOLITHIC MEMBRANE CONSISTING OF AC FAST FR AND AC FLEECE 120. AC PRIMER POWER-TOOL CLEAN METAL SURFACE TO BE FLASHED AC FAST FR RESIN 1" (25 mm) TYP. FIRESTONE PMMA MEMBRANE COLLAR CUT SNUG FIT AROUND PENETRATION TO PROVIDE 1" (25 mm) MIN. VERTICAL TURN UP 6" (152 mm) (MIN.) FIRESTONE PMMA MEMBRANE "SKIRT" WRAPPED AROUND METAL PENETRATION WITH 2" (51 mm) MIN. OVERLAP AT ALL JOINTS FIRESTONE MODIFIED BITUMEN CAP SHEET FIRESTONE MODIFIED BITUMEN BASE SHEET 6" (152 mm) (TYP.) MAXIMUM WARRANTY: 20 YEARS ANGLE FLASHING PMMA Firestone Building Products Sales: (800- 428-4442 ACCEPTABLE SYSTEMS: Technical (800) 428-4511 MODIFIED BITUMEN www.firestonebpco.com ISSUE / REVISION DATE: DETAIL NO. 4/25/2019 PMMA-12 NOT TO SCALE

OPTIONAL METAL COPING CAP TERMINATE FIRESTONE PMMA MEMBRANE AT OUTSIDE EDGE OF WALL PREPARE, LEVEL & PATCH SUBSTRATE AS REQUIRED PRIOR TO APPLICATION OF AC PRIMER AND AC FAST FR. NOTE: 1. REFER TO FIRESTONE WEBSITE FOR CURRENT INFORMATION. 2. AC PRIMER AND AC FAST FR ARE FOR USE ON MODIFIED BITUMEN SYSTEMS ONLY. DO NOT USE ON TPO OR EPDM. 3. THE TERM "FIRESTONE PMMA MEMBRANE" REFERS TO THE COMPLETED AND PROPERLY INSTALLED MONOLITHIC MEMBRANE CONSISTING OF AC FAST FR AND AC FLEECE 120. (1) PLY FIRESTONE PMMA MEMBRANE FLASHING. EXTEND 12" (305 mm) MIN. HORIZONTALLY ONTO FIRESTONE MODIFIED BITUMEN ROOF MEMBRANE CONT. BEAD OF FIRESTONE AP SEALANT REQUIRED IF GAP BETWEEN EDGE OF MODIFIED MEMBRANE & WALL GREATER THAN 1/16" (1.6 mm) (TYP.) ASSURE FULL CONTACT OF BOTH LAYERS W/ SUBSTRATE & FULL SATURATION OF FIRESTONE FLEECE 120 CONTINUOUS 4" (102 MM) WIDE STRIP OF FIRESTONE PMMA MEMBRANE AT WALL TO DECK TRANSITION 2" (51 mm) FIRESTONE MODIFIED BITUMEN CAP SHEET 6" (152 mm) MIN. FIRESTONE MODIFIED BITUMEN BASE SHEET 2" (51 mm) APPROVED SUBSTRATE MAXIMUM WARRANTY: 20 YEARS PARAPET FLASHING WITH COPING CAP PMMA Firestone Building Products Sales: (800- 428-4442 ACCEPTABLE SYSTEMS: Technical (800) 428-4511 MODIFIED BITUMEN www.firestonebpco.com ISSUE / REVISION DATE: DETAIL NO. 4/25/2019 PMMA-13 NOT TO SCALE

firestone cap sheet firestone base sheet approved substrate note: 1.refer to firestone website for most current information. 2.ac primer and ac fast fr are for use on modified bitumen systems only. do not use on tpo or epdm. 3.the term "firestone pmma membrane" refers to the completed and properly installed monolithic membrane consisting of ac .

Related Documents:

for the fabrication of 1,3,5,7-tetranitro-1,3,5,7-tetrazocane (HMX) based microcapsules. The PMMA/HMX-based microcapsules were prepared via a facile in situ polymerization of PMMA on the surface of the HMX crystals. Structural characterization of the PMMA/HMX microcapsules was studied systematically

The stabilized mats were further annealed in a tube furnace under N 2 flow at 800 ºC for 2 h at a heating rate of 5 ºC min-1. The heat treatments converted PAN to carbon fibers and decomposed the PMMA to form porous carbon nanofibers. PAN:PMMA (95:05), PAN:PMMA (90:10), and PAN:PMMA (60:40) were also prepared using the same procedure. .

SAN blend. Based on the knowledge related to the mis-cibility of PMMA with SAN (or PC), commercially avail-able PMMA was also examined as compatibilizer of PC/ ASA blend. Note that PMMA is miscible with SAN con-taining AN from 8 wt% to 33 wt% (Fowler et al ., 1987; Suess et al ., 1987) and PMMA blend with PC appeared to

Structural and Electrochemical Analysis of PMMA Based Gel Electrolyte Membranes ChithraM.Mathew,K.Kesavan,andS.Rajendran . computer controlled X pert PRO PANalytical di ractome- . Structural analysis of the prepared polymer complexes was carried out using X-ray di raction PVdC-AN PMMA R1 R2 R3 10 20 30 40 50 60 70 80 Intensity (a.u.)

E. Alternate Flashing Membrane: Manufacturers proprietary cold fluid applied Polymethyl methacrylate (PMMA) flashing system. 1. Acceptable Product: a. Laurenco PMMA PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates, areas, and conditions un

The bone defect was filled using 5ml of injectable PMMA-based bone cement (Traumacem V , Reference 07.702.040S; DePuy Synthes). Traumacem V is a com-posite of acrylic bone cement in conjunction with cer-amics consisting of 45% PMMA, 40% zirconium dioxide (radi

sample and wets the rims of the PS as evidenced by the halo around PS regions in Fig 2H. Underneath the PS domains, the PS–PMMA interface is still corrugated as a remnant of the PMMA domains that are ‘trapped’ inside the coalescing PS. Figure 3 shows the results of the compositional ma

and Career-Readiness Standards for English Language Arts. The second section includes the MS CCRS for ELA for kindergarten through second grade. The third section includes the MS CCRS for ELA for grades 3-5. The fourth section includes the MS CCRS for ELA, including Literacy in Social Studies, Science, and Technical Subjects. The final section .