Transcription

CABLE INLET. SUPPORT STRUCTURE OPERATING MECHANISM SF6 GAS TOTAL MASS 2 TERMINAL OF ALUMINIUM. 105 194 200 7 1322 APPROX. 3 1250 N DYNAMIC IN ANY DIRECTION. 4 HOLES FOR EARTHING CLAMP. 5 DYNAMIC FORCE DURING OPERATION. 6 SUPPORT STRUCTURE. 7 ARC CHAMBER INSULATOR 8 SUPPORT INSULATOR 9 OPEN/CLOSE INDICATOR. 255 4174 267 15 735 1750 16 2,3 186 7 1 1220 D Spring charging handle 3833 40 D 14(4x) Foundation plan 15 CLEAR SPACING FOR REVISION 12 36 750 Detail - B GENERAL ARRANGEMENT FOR 145kV SF6 CIRCUIT BREAKER TYPE LTB145D1/B WITH FSA1 NS ABB India Limited. 44 282 258 150 Thread Length P.L. 13 SQ,150 Pocket for foundation bolt Foundation bolt UP 12 10 10 D 57.5 60 D 14(5x) Detail - A 150 60 101.5 4 57 1910 SPRING CHARGING POINT. Detail D ) (7x 4 1 33.5 350 14 Detail C (HORIZONTAL) 12000N (VERTICAL) 250 Holes D 32 for bolt M24 495 400 1310 FOUNDATION DETAIL FOR STRUCTURE. 10 161.5 61.5 Revision Details: A New document prepared. 5 12000N 250 13 SF6 gas pipe. A 1000N FOUNDATION BOLT FOR STRUCTURE. M24 1560 1000N 12 Density Monitor with pressure indicator. SF6 gas filling point 5 OPERATING MECHANISM. ALL DIMENSION ARE IN MM. MAKE OF INSULATOR:- MODERN/JSI/IEC/WSI/SARVANA/ABIL/ FUSHUN HI-TECH.PPC/LILING HUAXIN/PRATHMESH OR EQUI. 6 1 11 - BREAKER STANDARD : IEC-62271-100. 2 2507 692 180 DENSITY MONITOR WITH PRESSURE INDICATOR. 700 180 11 2205 4 C 9 10 B 5196 5173 14 180 918 185 4 SF6 gas filling point 40 8 10 28 40 1750 133.5 80 272X3 A 20160531 1 POLEBEAM 1324 BREAKER POLES 1164 COMPUTERORIGINAL MASS IN KG KD 1HYB905395-1 1 1

2 3 4 5 6 7 8 COMPUTERORIGINAL 1 A A B B 220 VDC CONTROL VOLTAGE. : 230 VAC MOTOR VOLTAGE. C C HEATER VOLTAGE. : 230 VAC ITEM ABREVIATIONS :- D D DM:- DENSITY MONITOR OM:- OPERATING MECHANISM. DIAGRAM BASED ON IEC 617. LOCAL REMOTE SWITCH IN REMOTE POSITION. CIRCUIT BREAKER IN "OFF" POSITION. SPRING DISCHARGED. UPDATED. B SCHEMATIC E Revision Details AUXILIARY CIRCUIT "OFF" . DRAWN WITHOUT GAS PRESSURE. E NOTE :WIRING TO BE DONE WITH CU.WIRE (GREY FOR DC CKT. BLACK FOR AC CKT. , GREEN YELLOW FOR EARTHING. ) F We reserve all rights in this document and in the information contained there in reproduction, use or disclousure to third porties without express outhority is strictly forbidden ABB. 1:- 2.5 SQ. MM. FOR CONTROL CKT. 2:- 2.5 SQ. MM. FOR MOTOR CKT. 3:- 4.0 SQ. MM. FOR DOOR & PANEL EARTHING . TERMINAL FOR CUSTOMER CONNECTION. - S FOR :- SPARE TERMINAL. F - A.C Circuit Terminal block in Red colour. Revision SCHEMATIC DIAGRAM FOR 145kV SF6 CIRCUIT BREAKER TYPE LTB145D1/B WITH FSA1. B 20160915 1 2 3 4 DRAWN. UP CHECKED. APPRD. KD ABB India Limited 5 6 NS TOT AL SH REF. DRG.NO.: 1HYB904379-3 SH. NO. 1HYB905395-3 7 1 8

1 K1 2 -F11 VE 5 6 K1 OM-X3:134 K1 7 J3 8 1 2 -F12 VE REMOTE CLOSE 3 AUTO RECLOSING PROTECTION TRIP CKT.-I REMOTE TRIP CKT.-I K32 -S12 10 6 K22 K32 -X1 16 K13 12 B K32 20 -X1 3 1 K12 K12 -K2 34 32 /3.A8 /3.A8 12 33 22 4 2 12 -X1 22 -X1 14 21 -X1 15 -X1 23 K34 K26 -K1 22 D K34 K24 -S1 -S1 -S1 02 K25 E K35 F A1 -Y1 J2- 3 4 K2- A2 K2- A1 -Y2 -K1 2 -X1 2 1 1 -VE -K2 2 K2- K2- OM-X3:135 A2 K2- /3.F6 -Y3 -X1 4 J4- 3 4 K4- 1 K2- -VE K2- We reserve all rights in this document and in the information contained there in reproduction, use or disclousure to third porties without express outhority is strictly forbidden ABB. K25 K35 2 K 5 14 92 K25 K25 K19 K19 K17 -S1 04 82 K19 -S1 -S1 08 13 91 03 81 K35 07 K35 K19 K27 K16 01 Revision Details POST CLOSE TRIP CIRCUIT-II SUPERVISION. K36 K24 PRE CLOSE TRIP CIRCUIT -II SUPERVISION. C 21 K34 K24 K15 -K1 14 POST CLOSE TRIP CIRCUIT-I SUPERVISION. PRE CLOSE TRIP CIRCUIT-I SUPERVISION. 11 6 -X1 110/220 V DC SUPPLY -II -X1 17 -S3 32 -XO 33 -XO 23 K12 K14 23 5 24 31 -F2 21 -F2 K12 -K2 14 31 -XO -XO 21 2 1 K 11 110/220 V DC SUPPLY -I K30 K31 K23 K1 -S12 K22 K13 11 31 FOR ISOLATOR -X1 41 K12 INTERLOCK -X1 46 4 9 -S12 8 K13 K13 -X1 13 2 5 -S12 2 4 -X1 42 K13 E A /2.A5 K32 K13 7 -S12 B -X1 45 K21 K11 K10 1 -S12 -S14 -X1 12 K22 -X1 11 -X1 9 3 REMOT E D PROTECTION TRIP CKT.-II 3 -S14 4 LOCAL REMOTE TRIP CKT.-II 1 -S13 C -X1 3 /3.D6 K1 J1 4 K1 COMPUTERORIGINAL A -X1 1 3 K3 2 1 2 -F12 -F11 F CLOSING CKT. TRIP CKT.-I ANTIPUMPING Revision SCHEMATIC DIAGRAM FOR 145kV SF6 CIRCUIT BREAKER TYPE LTB145D1/B WITH FSA1. B 20160915 1 2 3 4 DRAWN. UP SF6 SUPERVISION FOR CLOSE & TRIP CKT-I CHECKED. APPRD. KD NS ABB India Limited 5 6 TRIP CKT-II TOT AL SH REF. DRG.NO.: 1HYB904379-3 SH. NO. 1HYB905395-3 7 2 8

2 4 7 -X1 7 H1 -X1 8 -X1 18 A 1 H2 -F4 -X1 29 H1 1 -X1 31 H2 H1 M1 H1 H1 -F5 1 -XO 11 L3 L1 -F3 H3 2 /2.C6 2 2 7 21 1 2 H2 11 21 31 6.2 bar(abs.) 0.62 MPa(abs) 6.0 bar(abs.) 0.6 MPa(abs) 6.0 bar(abs.) 0.6 MPa(abs) 13 -K2 8 24 12 23 22 33 32 -XO 12 22 6 B H5 -S3 -F2 H4 3 -S3 2 H6 1 0 -S3 H2 -T1 -M H2 M3 1 B 8 230V AC HEATER SUPPLY -X1 6 M2 6 /2.C8 -X1 5 5 5 230V AC MOTOR SUPPLY COMPUTERORIGINAL A 3 H2 1 M M4 -X1 32 -X1 30 -PP -L H2 H5 H2 1 H4 2 H2 L -X3 101 103 SF6 PRESSURE BLOCKING C SPRING CHARGING MOTOR HEATER / ILLUMINATION / SOCKET (OUTLET),THERMOSTAT 105 107 111 109 113 115 117 119 121 123 125 -X1 19 N SPRING CHARGING INDICATION 2 F H2 M5 A L4 -M1 L2 M4 M5 -R3 127 129 131 ALARM -X3 TRIP-II BLOCK 0.6 Mpa (abs.) SF6 GAS REPLENISHEMENT ALARM AT 0.62 Mpa (abs.) 4 CLOSING/TRIP BLOCK 0.6 Mpa ( abs.) 1 2 C F2-SF6 GAS DENSITY MONITOR -X3 134 K1 /2.A6 -X3 137 -X3 139 -X3 141 K1 U31 U29 U27 U25 U23 U21 U19 U17 U15 U13 U11 U9 U7 U5 U3 D U1 D -X3 143-X3 145 -X3 147 -X3 149 -X3 151 63 71 73 93 201 103 301 -S1 -S1 -K3 -S1 22 32 34 42 44 52 54 62 64 72 74 94 202 104 K49 302 110 112 114 116 118 120 122 124 126 128 130 132 32 44 14 42 12 K215 K213 K211 K207 K205 K209 -K4 -K4 41 -K4 24 22 -K4 34 32 44 42 E -X3 144 -X3 146-X3 148 -X3 150 -X3 152 K2K2- 108 22 34 31 K2- K2- U32 U30 U28 U26 U24 U22 U20 U18 U16 U14 U12 U10 U8 U4 U6 106 12 24 -X3 138 -X3 140 -X3 142 A2 K2104 14 -K3 21 11 41 -K4 A2 -X3 102 -K3 A1 -K3 31 12 A1 U2 We reserve all rights in this document and in the information contained there in reproduction, use or disclousure to third porties without express outhority is strictly forbidden ABB. F 24 21 -K3 K49 Revision Details K49 E 11 K216 61 K214 53 K212 51 K210 43 K208 41 K206 33 K204 31 K202 23 K49 21 K203 K201 11 -X3 /2.F6 K2- -X3 135 Auxilliary Switch contacts Multiplied relay contacts for Auxilliary Switch F SPARE AUXILIARY SWITCH CONTACTS (8 NO 8 NC) (4 NO 4 NC) (12 NO 12 NC) CHECKED. DRAWN. UP KD SCHEMATIC DIAGRAM FOR 145kV SF6 CIRCUIT BREAKER ABB India Limited TYPE LTB145D1/B WITH FSA1. Revision B 20160915 1 2 3 4 5 6 APPRD. NS TOT AL SH REF. DRG.NO.: 1HYB904379-3 SH. NO. 1HYB905395-3 7 3 8

F Revision Details E We reserve all rights in this document and in the information contained there in reproduction, use or disclousure to third porties without express outhority is strictly forbidden ABB. 1 X3 :-AUX. SPARE CONTACT TERMINALS. S :- FOR SPARE TERMINAL . B 20160915 2 3 4 Revision SCHEMATIC DIAGRAM FOR 145kV SF6 CIRCUIT BREAKER TYPE LTB145D1/B WITH FSA1. DRAWN. 5 UP CHECKED. KD ABB India Limited 6 APPRD. NS 7 DC SUPPLY-I DC SUPPLY-II VE -VE VE -VE L N L N X1 E I I D E 1HYB905395-3 8 X3 TERMINAL : CLTDM4 MAKE : ELMEX 101 102 103 104 105 106 107 108 109 110 111 112 113 114 TERMINAL : CLTDM4 MAKE : ELMEX 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 X3 X3 7 TERMINAL : CLTDM4 MAKE : ELMEX 1 2 3 4 5 6 7 8 9 10S 11 12 115 116 117 118 119 120 6 MOTOR SUPPLY HEATER SUPPLY REMOTE CLOSE AUTO RECLOSING REMOTE TRIP CKT.-I REMOTE TRIP CKT.-II 13 14 15 16 17 18 121 122 123 124 125 126 127 128 129 130 5 PRE CLOSE TRIP CKT.-I SUPERVISION F2-21 F2-23 F2-11 19 20 21 C PRE CLOSE TRIP CKT.-II SUPERVISION SF6 DENSITY MONITER F2-33 F2-12 F2-31 22 23 29 30 31 32 41 131 132 134 4 PROTECTION TRIP CKT.-I SUPERVISION PROTECTION TRIP CKT.-II SUPERVISION SF6 PRESSURE BLOCKING SPRING CHARGING INDICATION ISOLATOR INTERLOCK 42 45 46 X3 3 POST CLOSE TRIP CKT.-I SUPERVISION POST CLOSE TRIP CKT.-II SUPERVISION X1 :- SUPPLY & CUSTOMER CONNECTION TERMINALS. 35S 135 B 40S X1 B 2 47S 48S A A COMPUTERORIGINAL 1 8 AUXILIARY SPARE CONTACTS TERMINAL ARRANGEMENT FOR OPERATING MECHANISM REF. DRG.NO.: 1HYB904379-3 TOT AL SH SH. NO. 4 A B C D E F

2 COMPUTERORIGINAL 1 A B C F We reserve all rights in this document and in the information contained there in reproduction, use or disclousure to third porties without express outhority is strictly forbidden ABB. E 4 5 6 7 8 Bill of Material SL. DESCRIPTION ITEM DESIGNATION 1 DM-F2 SF6 GAS DENSITY MONITOR 2 DM-XO(6) TERMINAL BLOCK IN DENSIY MONITOR 3 OM-F3 1 POLE MCB-MOTOR 4 OM-F4 1 POLE MCB-HEATER 5 OM-F5 1 POLE MCB-SUPPLY SOCKET 6 OM-F11 2 POLE MCB-DC SUPPLY-I 7 OM-F12 2 POLE MCB-DC SUPPLY-II 8 OM-K1 ANTI PUMPING RELAY 9 OM-K2 GAS SUPERVISION RELAY 10 OM-K3 MULTIPLYING RELAY 11 OM-K4 MULTIPLYING RELAY 12 OM-L IILUMINATION LAMP 13 OM-M DOOR LIMIT SWITCH 14 OM-M1 SPRING CHARGING MOTOR 15 OM-PP SOCKET(OUTLET) 16 OM-R3 HEATER 17 OM-S1 AUXILIARY CONATCT 18 OM-S3 MOTOR LIMIT SWITCH 19 OM-S12 LOCAL REMOTE SWITCH 20 OM-S13 PUSH BUTTON RED 21 OM-S14 PUSH BUTTON GREEN 22 OM-T1 THERMOSTAT 23 OM-X1(35) TERMINAL BLOCK-CLTDM4 24 OM-X3(50) TERMINAL BLOCK-CLTDM4 25 OM-Y1 CLOSE COIL 26 OM-Y2 TRIP-I COIL 27 OM-Y3 TRIP-II COIL A B C D Revision Details D 3 E F Revision APPARATURS LISTS FOR 145kV SF6 CIRCUIT BREAKER TYPE LTB145D1/B WITH FSA1. B 20160915 1 2 3 4 DRAWN. UP CHECKED. APPRD. KD TOT AL SH NS 1HYB905395-3 5 6 SH. NO. 1HYB905395-3 ABB India Limited 7 5 8

2 1 3 5 6 7 8 POS. DEVICE NO. NO. COMPUTERORIGINAL A 4 HINGE S3 1 M DOOR LIMIT SWITCH 2 M1 SPRING CHARGING MOTOR 3 S3 MOTOR LIMIT SWITCH 4 S12 SELECTOR SWITCH (LOCAL-REMOTE) 2 3 5 Y3 Y1 B -F3 -F12 -F11 1HYB905395-3 1HYB905395-3 OM 1HYB905395-3 OM -F4 1HYB905395-3 OM -F5 1HYB905395-3 OM OM Y2 1HYB905395-3 OM 1HYB905395-3 242214 12 OM 242214 1HYB905395-3 12 OM 1HYB905395-3 242214 12 OM 24221412 2 3 1 7 2 3 1 7 2 3 1 7 2 3 OM1 * 20 30 * 40 * 50 * * 0 ABB ABB 60 ABB 8 6 5 7 8 6 5 7 8 6 5 7 8 6 5 7 A22111A1 A22111A1 A22111A1 A22111A1 M1 CABLE TRAY * 10 ABB L 7 R3 8 PP SOCKET(OUTLET) 9 T1 THERMOSTAT 10 F3 1 POLE MCB- MOTOR 11 F4 1 POLE MCB - HEATER 12 F5 1 POLE MCB - SOCKET 13 F11,F12 2 POLE MCB -DC SUPPLY I & II 14 K1 ANTI-PUMPING RELAY 15 K2 GAS SUPERVISION RELAY X3 HEATER B 16 X1,X3 17 S1 AUXILARY SWITCH 18 Y1 CLOSING COIL 19 Y2,Y3 TRIP-I & II COIL 20 K3, K4 MULTIPLYING RELAY 21 T1 THERMOSTAT TERMINAL BLOCK (EXTERNAL) D OM 1HYB905395-3 C -S12 OM 1HYB905395-3 S1 -PP LOCAL REMOTE NOTE:S13 S14 a).INSTRUMENTS LAYOUT IS FOR INDICATING PURPOSE ILLUMINATION LAMP X3 CABLE TRAY D PUSH BUTTON SWITCH (CLOSE,TRIP) -T1 1HYB905395-3 7 CABLE TRAY R3 -K1 -K2 -K3 -K4 S13, S14 6 CABLE TRAY X1 A L 1 C DESCRIPTION M & MAY CHANGED DURING SUPPLY. b).ALL EMPTY MOUNTING HOLES TO BE BLOCKED LAYOUT ELECTRICAL COMPONENT AS PER SCHEMATIC DIAGRAM 1HYB905395-3. WITH RUBBER GROMMAT. Revision Details E c).COMPONENT MOUNTING ON DRIVE:E Y1,Y2,Y3,S3,S1,M,M1 d). 1 - COUNTER F We reserve all rights in this document and in the information contained there in reproduction, use or disclousure to third porties without express outhority is strictly forbidden ABB. 2 - SPRING CHARGED INDICATION 3 - CB ON - OFF INDICATION e). LOOSE BUNCH TO BE KEPT FOR 150mm. F Revision LAYOUT ELECTICAL COMPONENT FOR 145kV SF6 CIRCUIT BREAKER TYPE LTB145D1/B WITH FSA1. A 20160528 1 2 3 4 DRAWN. NS CHECKED. APPRD. KD ABB India Limited 5 6 UP TOT AL SH REF. DRG.NO.: 1HYB905395-3 1 SH. NO. 1HYB905395-13 7 1 8

MADE in ABB FSA-1(F) Operating mechanism type FSA-1(F) Mass 200 Kg No. (See note 2.) Rated voltage 145 kV 220 VDC 500W Coils 230 VAC 735W Motor 230 VAC 50W Heater Operating device type No. (See note 2.) 4201275663 Order Breaking current 40 kA DC-component 36 % First-pole-to-clear-factor 1.5 Making current 100 kA Short-time current 3s 40 kA (29) MADE in ABB (72) - Letter height 2 & line 0.3 thk. - Blank text is to be engraved at ABB. - Text to be filled with Sun-Proof black ink. - Langauge English. Line charging breaking current 50 A Mass total 1322 kg Mass of gas 7 kg Rules IEC 62271-100 Operating sequence O-0.3s-CO-3min-CO Temperature class -30 C Year of manufacture 2019 6 A 10 (See note 1.) 29 LTB145D1/B Circuit-breaker type No. (See note 1.) 4201275663 Order 145 kV Voltage Insulation level lightning imp.with.voltage 650 kV switching imp.with.voltage - kV power frequency with.voltage 275 kV Frequency 50 Hz Normal current 3150 A abs ( 20 C) Gas pressure SF6 0.9 MPa Max. working pressure Filling 0.7 MPa Signal 0.62 MPa Blocking 0.6 MPa 50 l Volume per pole 2 128 COMPUTERORIGINAL 1 MADE in ABB 48 - MOUNTED ON DRIVE Blank text is to be engraved at ABB. Text to be filled with Sun-Proof black ink. General tolerance as per ISO 2768-c, 89. Language English. ****** As Applicable. 4 29 10 29 A1 B1 NOTE 1. CIRCUIT BREAKER SERIAL NO. NOTED IN THIS SPACE. 2. OPERATING MECHANISM SERIAL NO. NOTED IN THIS SPACE. 5 (See note 1.) C1 MADE in ABB MADE in ABB MADE in ABB 48 48 48 - MOUNTED ON RESPECTIVE POLES. 1 1 1 1 10 (See note 1.) (See note 1.) 29 3 - 10 Revision Details: 192 - Engraved on natural background. - Letter height 3.5 & line 0.3 thk. 1 1 Rating Rating Rating Rating Rating Rating QTY. DES CRI PTION NS plate plate plate plate plate plate 6 5 4 3 2 1 KD ITEM NO. S.S. 07Cr18Ni9 IS:6911-'92 S.S. 07Cr18Ni9 IS:6911-'92 S.S. 07Cr18Ni9 IS:6911-'92 S.S. 07Cr18Ni9 IS:6911-'92 1HYB700001-A S.S. 07Cr18Ni9 IS:6911-'92 S.S. 07Cr18Ni9 IS:6911-'92 MATERIAL / CODE NO. SIZE / IDENTIFICATION NO. NS RATING PLATES FOR 145kV SF6 CIRCUIT BREAKER TYPE LTB145D1/B WITH FSA1 A 20160916 WT. 1HYB905575-9 E 1 1

COMPUTERORIGINAL 918 Electrical appparatus plate 477 636 522 563 NOTE:- Elevation (without door and apparatus mounting plate) Side view 1). DEGREE OF PROTECTION IP 55. 2). COLOUR SHADE 631 IS: 5. 3). CABINET THICKNESS:2 mm STEEL SHEET. OPERATING MECHANISM FOR 145kV SF6 CIRCUIT BREAKER TYPE LTB145D1/B WITH FSA1

145kv sf6 circuit breaker type ltb145d1/b with fsa1. 20160915 1hyb904379-3 control voltage. diagram based on iec 617. local remote switch in remote position. circuit breaker in "off" position. auxiliary circuit "off" . drawn without gas pressure. spring discharged. note :-wiring to be done with cu.wire (grey for dc ckt.

Related Documents:

Pradeep Sharma, Ryan P. Lively, Benjamin A. McCool and Ronald R. Chance. 2 Cyanobacteria-based (“Advanced”) Biofuels Biofuels in general Risks of climate change has made the global energy market very carbon-constrained Biofuels have the potential to be nearly carbon-neutral Advanced biofuels Energy Independence & Security Act (EISA) requires annual US production of 36 .

Playing Guitar: A Beginner’s Guide Page 7 Practicing Here are a few notes about how to approach practicing with the best frame of mind. First, don’t hurt yourself, especially when you’re just starting.

AQA GCE Biology A2 Award 2411 Unit 5 DNA & Gene Expression Unit 5 Control in Cells & Organisms DNA & Gene Expression Practice Exam Questions . AQA GCE Biology A2 Award 2411 Unit 5 DNA & Gene Expression Syllabus reference . AQA GCE Biology A2 Award 2411 Unit 5 DNA & Gene Expression 1 Total 5 marks . AQA GCE Biology A2 Award 2411 Unit 5 DNA & Gene Expression 2 . AQA GCE Biology A2 Award 2411 .

A CAMINO WITH DON BOSCO . Novena in Preparation for the Feast of St John Bosco . Fr Gerry O’Shaughnessy SDB . Recommended reading: Jesus and Young People by Fr Michael Winstanley SDB, Don Bosco Publications, Bolton 2020 . Don Bosco's Dream by M Borgani via sdb.org . 2 . Welcome! One of the great traditions of our Catholic Church is the idea of NOVENA. With a name derived from the Latin for .

An example of Business Architecture Q&A 1. Why? What are the goals of the business? Attract more customers to the hotel. 2. What services will the business provide to those ends? Free valet parking of a car (along with other services) 3. What processes must be performed to deliver those services? 4. What roles will perform activities in processes? Valet (3 actors) 5. What data .

Since the end of the Cold War, events between the newly-founded Russian Federation and a reformist People’s Republic of China have taken a turn in the opposite direction, towards a remarkable renewal and strengthening of Sino-Russian ties. After four decades of seemingly insurmountable suspicion and bilateral crises, which more than once threatened to escalate into all-out armed conflict .

CIPS Level – Diploma in Procurement and Supply . Module 4 – Ethical and Responsible Sourcing . SAMPLE EXAM QUESTIONS . OBJECTIVE RESPONSE QUESTIONS AND ANSWERS . The correct answer will be identified as [key] 2 L4M4 Exam Exemplar Questions Dec 2018 . Q1. Which of the following is the most effective measure for a procurement manager to identify potential risks in relation to a supplier's .

CLASSIC and GypWall ROBUST GypWall CLASSIC and GypWall ROBUST The definative metal stud and partition system GypWall CLASSIC partitions are cost-effective, multi-purpose partitions, which have provided the industry standard for many years. They are suitable for all types of buildings, including residential, healthcare and commercial. GypWall ROBUST is a high impact-resistant partition system .