Section Updated 04/2019Dry Type TransformersSection 10—Find What You Need Faster - Page headings and tableformat make product selection easier.—Easy Cross Reference - Frame size listed with each modelnumber. Use frame size to cross-reference dimensions,enclosure parts, and accessories.General InformationTypes QB, QMS, QL. 10-2General PurposeSingle-Phase DOE 2016 Efficiency, Aluminum.10-4Single-Phase DOE 2016 Efficiency, Copper.10-5Three-Phase DOE 2016 Product Number Nomenclature.10-6Three-Phase DOE 2016 Efficiency, Aluminum. 10-9Three-Phase DOE 2016 Efficiency, Copper.10-11K-FactorThree-Phase DOE 2016 Efficiency, Aluminum.10-12Three-Phase DOE 2016 Efficiency, Copper.10-16K-Factor Low NoiseThree-Phase DOE 2016 Efficiency, Aluminum.10-20Three-Phase DOE 2016 Efficiency, Copper.10-22Low NoiseThree-Phase DOE 2016 Efficiency, Aluminum.10-24Three-Phase DOE 2016 Efficiency, Copper.10-25Noise Isolation – Guard IThree-Phase DOE 2016 Efficiency, Aluminum.10-26Three-Phase DOE 2016 Efficiency, Copper.10-27Noise Isolation – Guard II. 10-28Three-Phase DOE 2016 Efficiency, Aluminum.10-29Three-Phase DOE 2016 Efficiency, Copper.10-30Harmonic Mitigating – Guard IIIThree-Phase DOE 2016 Efficiency, Copper.10-31Rev. 1/19Data subject to changewithout noticego.abb/industrialServicenter Mini-Unit Substations –Integral Transformer and Distribution Center.10-32Single-Phase and Three-Phase DOE 2016 Efficiency. 10-33Outlines, Dimensions, Wiring Diagrams.10-34Totally Enclosed, Nonventilated – TENV. 10-35Aluminum and Copper DOE 2016 Efficiency. 10-36MidtappedAluminum DOE 2016 Efficiency.10-37Copper DOE 2016 Efficiency.10-38Drive IsolationThree-Phase.10-40Accessories and Lugs. 10-42Enclosure Parts.10-44Wiring Diagrams. 10-45Dimensions. 10-46General Purpose Transformers in EnclosuresSingle-Phase.10-48Buck-Boost Encapsulated Transformers. 10-51Selection Tables. 10-54Connection Diagrams. 10-61Open Core and Coil Transformers. 10-62Machine Tool Applications.10-63Control.10-64Options and Fusing Guide. 10-66Wiring Diagrams. 10-67Outlines and Dimensions. 10-68CE-Rated.10-69GE Products BuyLog10-1

Dry Type TransformersSection 10General InformationTypes QB, QMS, QL600 Volts and BelowGeneral InformationTemperature ClassThe complete family of transformers from GE provide quiet,reliable transformer operation.Industry standards classify insulation systems in accordance withthe rating system shown below.All of the dry-type transformers through 1,000 kVA are UL listedunder the requirements of Standard 5085 and 1561. In addition,each transformer meets the requirements of NEMA ST-20, 1992.Type IP, QB and QMS models are C-UL listed.General-purpose transformers are rated 600 Volts and below forsupplying appliance, lighting, and power loads from electricaldistribution systems. Standard distribution voltages are 600, 480,and 240 Volts; standard load voltages are 480, 240, 208, and 120Volts. The transformer is used to obtain the load voltage from thedistribution voltage. Since no vaults are required for installation,these transformers can be located right at the load to providethe correct voltage for the application. This eliminates the needfor long, costly, low-voltage feeders.AmbientInsulation System Classification Winding Rise Hot Spot40 C40 C40 C40 C55 C80 C115 C150 C Temp. Class10 C30 C25 C30 C105 C150 C180 C220 CAll standard, general-purpose, GE transformers meet all applicableNEMA, ANSI, UL, and IEEE standards.The design life of transformers having different insulation systemsis the same, since the allowable temperature rise of an insulationmaterial system is predicated on a specified life for all insulation.The lower temperature systems are designed for the same life ashigher temperature systems.Sound LevelsConstructionTypes QB and QMSCore and coils are contained within a NEMA 3R nonventilatedweatherproof enclosure. Type QB and QMS units featureencapsulated core and coils.Type QLUnits are enclosed in a NEMA 2 drip-proof painted metal enclosure with natural draft ventilation. The core-and-coil assembly ismounted on rubber isolation pads to reduce noise. Weathershieldkits are available for conversion to a NEMA 3R enclosure suitablefor outdoor service. NEMA 2 and NEMA 3R stainless steel (Type316) enclosures are available up to 150kVA. To specify a stainlesssteel enclosure for an aluminum-wound transformer, substitutethe letter “S” in the fifth character of the GE product number. Forexample, 9T10A1004 changes to 9T10S1004. For copper-woundtransformers, substitute the letter “Z” in the fifth character of theGE product number. For example, 9T10C1004 changes to9T10Z1004. All QL model product numbers begin with 9T7, 9T8,or 9T1.All general-purpose transformers are as quiet, or quieter thanrequired by NEMA ST-20. Average sound levels are warranted notto exceed the values listed for each load rating shown in theadjacent table. Sound characteristics vary between transformersof identical voltage and kVA rating. The range of variation may be4 to 8 decibels.These values apply only to specified test conditions because thecharacteristic of the installation can cause them to be higherunder operating conditions. Where acoustical noise is deemed tobe of unusual concern, proper steps should be taken duringinstallation to minimize audible noise transmission.Sound Levels (Decibels)1 for 150 C Rise ModelskVA0-910 - 5051 - 150151 - 300301 - 500Sound Levels40455055601Measured per NEMA ST-20.Transformer taps compensate for high or low line voltages. Moststandard QL units rated 15kVA through 300kVA and with a primary voltage of 240V or higher have six available voltage taps –four 2.5% taps below the nominal tap and two 2.5% taps abovethe nominal tap. This arrangement provides a 15% range of tapvoltage adjustment. Transformers rated 500kVA and higher havefour available voltage taps – two 2.5% taps above the nominaltap and two 2.5% taps below the nominal tap.10-2GE Products BuyLoggo.abb/industrialRev. 1/19Data subject to changewithout notice

Dry Type TransformersSection 10General InformationTypes QB, QMS, QL600 Volts and BelowTerminationImproved termination spacing and wiring compartment roomgives greater flexibility in selecting various UL listed connectorsfor either copper or aluminum cable.Product Number Selection Instructions1. Establish phase and frequency2. Determine the primary voltage—the voltage presently available3. Determine the secondary voltage—the voltage needed atthe loadType QB, .050 kVA-3 kVA, Single-Phase4. Determine the kVA load, allowing room for expansion5. Using the facts determined in the four steps, locate thetransformer model in the listings on the following pages.Type QMS, 5 kVA-25 kVA, Single-PhaseType QL, 15 kVA-250 kVA, Single-Phase, DOE 2016 Efficiency,15 kVA-500 kVA, Three-Phase, DOE 2016 EfficiencyRev. 1/19Data subject to changewithout noticego.abb/industrialGE Products BuyLog10-3

Section 10Dry Type TransformersGeneral PurposeAluminumSingle-Phase DOE 2016 Efficiency150 C Rise NEMA 2InputVoltage240 x 480 VoltsOutputVoltage120 x 240 VoltskVATapsWiringDiagram No.1Approx. NetWeight (Lbs)FrameSizeProductNumber152537.55075100167250( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 9T83B2677kVATapsWiringDiagram No.1Approx. NetWeight (Lbs)FrameSizeProductNumber152537.55075100167( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 83B2676G15kVATapsWiringDiagram No.1Approx. NetWeight (Lbs)FrameSizeProductNumber152537.55075100167( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 T83B2676G80115 C Rise NEMA 2InputVoltage240 x 480 VoltsOutputVoltage120 x 240 Volts80 C Rise NEMA 2InputVoltage240 x 480 VoltsOutputVoltage120 x 240 Volts1See page 10-45 for wiring diagrams.10-4GE Products BuyLoggo.abb/industrialRev. 1/19Data subject to changewithout notice

Section 10Dry Type TransformersGeneral PurposeCopperSingle-Phase DOE 2016 Efficiency150 C Rise NEMA 2InputVoltage240 x 480 VoltsOutputVoltage120 x 240 VoltskVATapsWiringDiagram No.1Approx. NetWeight (Lbs)FrameSizeProductNumber152537.55075100167( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 ingDiagram No.1Approx. NetWeight (Lbs)FrameSizeProductNumber152537.55075100167( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 T83C2576G15kVATapsWiringDiagram No.1Approx. NetWeight (Lbs)FrameSizeProductNumber152537.55075100167( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 9T83C2576G80115 C Rise NEMA 2InputVoltage240 x 480 VoltsOutputVoltage120 x 240 Volts80 C Rise NEMA 2InputVoltage240 x 480 VoltsOutputVoltage120 x 240 Volts1See page 10-45 for wiring diagrams.Rev. 1/19Data subject to changewithout noticego.abb/industrialGE Products BuyLog10-5

Section 10Dry Type TransformersGeneral PurposeThree-PhaseDOE 2016 Product Number Nomenclature9T10A1001G31Group NumberNo Group Number Shown 150 CG02 150 C, -3dBG03 150 C, Electrostatic Shield†G04 150 C, Electrostatic Shield†, -3dBG05 150 C, -5dBG06 150 C, Electrostatic Shield†, -5dBG09 150 C, Non-STD kVAG10 150 C, Non-STD kVAG29 140 C, 40 C ambG30 140 C, 50 C ambG31 115 CG32 115 C, -3dBG33 115 C, Electrostatic Shield†GE StandardkVA Rating1 15kVA2 30kVA3 45kVA4 75kVA5 112.5kVA6 150kVA7 225kVA8 300kVA9 500kVA1 QL DOE 2016 DesignTransformer Type0 Standard, K11 K132 K203 K304 K47 Guard II/Servicenter8 Spare PartsCoil MaterialA AluminumC CopperVoltage RatingSee Voltage Chart belowG34 115 C, Electrostatic Shield†, -3dBG35 115 C, -5dBG36 115 C, Electrostatic Shield†, -5dBG39 115 C, Non-STD kVAG40 115 C, Non-STD kVAG61 80 CG62 80 C, -3dBG63 80 C, Electrostatic Shield†G64 80 C, Electrostatic Shield†, -3dBG65 80 C, -5dBG66 80 C, Electrostatic Shield†, -5dBG69 80 C, Non-STD kVAG70 80 C, Non-STD kVA†An Electrostatic Shield (also called a Guard I transformer) is a grounded, aluminum barrier between the primaryand secondary winding to reduce electrical noise. All K-Factor transformers contain an Electrostatic Shield.3-Phase Common 4915015115215315415510-6Primary 8208240240240Secondary 00460Y/266220230/115415Y/240480Y/277480400Y/231GE Products 205206207209210211Primary 0400400400400Secondary 42243244245246247248249250251252Primary 600690690277315320420490500Secondary 80Y/277480Y/277480Y/277480Y/277Rev. 1/19Data subject to changewithout notice

Section 10Dry Type TransformersGeneral PurposeThree-PhaseDOE 2016 Product Number Nomenclature3P Servicenter Product Numbers – DOE 01522.5301522.530Primary 80600600600Secondary 0Product 9T17C00259T17C0026Primary Voltage480480480480480480480480480480Secondary Y/120208Y/120208Y/120208Y/120208Y/120Product 039T17C1004G039T17C1005G03Guard II Product Numbers – DOE 2016MaterialALCURev. 1/19Data subject to changewithout alGE Products BuyLog10-7

Section 10Dry Type TransformersGeneral PurposeAluminumThree-Phase DOE 2016 EfficiencyAdvantages—Quiet performance—No-weld design – an industry first—Comprehensive factory testing assures quality—Accessible mounting foot design speeds installation—Lug kit and ground bar kit included up through 150kVA—GE’s exclusive wood crate packaging helps reduceshipping damageKey Features—Unique core and coil design makes QL transformers among thequietest available—Core and coil assemblies are mounted on rubber isolation padsto reduce noise—Bolted coil terminations are more reliable than welded terminations, and they eliminate weld failures and problems associatedwith welding and weld splatter—Single-piece front/back is easily removable for service—Accessible mounting flanges with front/back slotted mountingholes make installation easier—100% factory tested for shorts and coil integrity, current andloss, voltage, impedance and noise.—NEMA 2 powder-coat drip-proof enclosure is standard.Weathershield kit is available for conversion to NEMA 3Routdoor.—NEMA 3R stainless steel enclosure is available up to 150kVA.To specify a stainless steel enclosure, substitute an “S” in thefifth character in the GE catalog number.Example: 9T10A1004 changes to 9T10S1004.Type QL Transformer—Seismic qualified to the requirements of ASCE 7.05,IEEE-693-2005 and IBC-2012/CBC-2013—Copper or aluminum windings—Copper ground strap—Robust packaging with top and side protection protects againstshipping ors—Incandescent lighting—Resistance heating—Motor generators (without solid state drives)10-8GE Products BuyLogTENVStainless Steel(type 316) EnclosureXXXXXXXXService CenterK -Factor (K 30)XXXXXXXXDITK -Factor (K 20)K -Factor (K 13)K -Factor (K 4)XXXXGuard IIIXXXXGuard IIGuard IMotorsIncandescent LightingResistance HeatingMotor Generators (without solid state drives)HID LightingInduction HeatersWeldersUPS with optional input filteringPLC & Solid state controlsMultiple receptacle circuits in heath care facilitiesUPS without optional input filteringProduction or assembly line equipmentSchools & Classroom facilitiesSurge SupressionOffice BuildingsSCR Variable Speed DrivesCircuits with exclusive data processing equipmentCritical Care facilitiesHospital Operating RoomsX-ray equipmentComputer InstallationsProgrammable ControllersInstrumentationAC or DC Variable Speed DrivesRectifier outputsTemporary PowerAirborne contamins or dust-laden environments (indoor and outdoor)Corrosive environments including water/wastewater and salt sprayStandardTransformer Selection ndustrialRev. 1/19Data subject to changewithout notice

Section 10Dry Type TransformersGeneral PurposeAluminumThree-Phase DOE 2016 EfficiencyType QL Transformer150 C Rise NEMA 2InputVoltage480 Volts DeltaOutputVoltage208Y/120 VoltskVATapsWiringDiagram No.1Approx. NetWeight 00750( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -2 2.5%)( 2, -2 apsWiringDiagram No.1Approx. NetWeight 00750( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -2 2.5%)( 2, -2 319T10A1009G319T10A1302G31kVATapsWiringDiagram No.1Approx. NetWeight 00( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -4 2.5%)( 2, -2 2.5%)( 2, -2 2.5%)12121212121

Dry Type Transformers General Information Section 10 Types QB, QMS, QL 600 Volts and Below General Information The complete family of transformers from GE provide quiet, reliable transformer operation. All of the dry-type transformers through 1,000 kVA are UL listed under

Related Documents:

applications including generator step-up (GSU) transformers, substation step-down transformers, auto transformers, HVDC converter transformers, rectifier transformers, arc furnace transformers, railway traction transformers, shunt reactors, phase shifting transformers and r

Transformers (Dry-Type). CSA C9-M1981: Dry-Type Transformers. CSA C22.2 No. 66: Specialty Transformers. CSA 802-94: Maximum Losses for Distribution, Power and Dry-Type Transformers. NEMA TP-2: Standard Test Method for Measuring the Energy Consumption of Distribution Transformers. NEMA TP-3 Catalogue Product Name UL Standard 1 UL/cUL File Number .

- IEC 61558 – Dry Power Transformers 1.3. Construction This dry type transformer is normally produced according to standards mentioned above. Upon request transformers can be manufactured according to other standards (e.g. standards on ship transformers, isolation transformers for medical use and protection transformers.

7.8 Distribution transformers 707 7.9 Scott and Le Blanc connected transformers 729 7.10 Rectifier transformers 736 7.11 AC arc furnace transformers 739 7.12 Traction transformers 745 7.13 Generator neutral earthing transformers 750 7.14 Transformers for electrostatic precipitators 756 7.15 Series reactors 758 8 Transformer enquiries and .

2.5 MVA and a voltage up to 36 kV are referred to as distribution transformers; all transformers of higher ratings are classified as power transformers. 0.05-2.5 2.5-3000 .10-20 36 36-1500 36 Rated power Max. operating voltage [MVA] [kV] Oil distribution transformers GEAFOL-cast-resin transformers Power transformers 5/13- 5 .

cation and for the testing of the transformers. – IEC 61378-1 (ed. 2.0): 2011, converter transformers, Part 1, Transformers for industrial applications – IEC 60076 series for power transformers and IEC 60076-11 for dry-type transformers – IEEE Std, C57.18.10-1998, IEEE Standard Practices and Requirements for Semiconductor Power Rectifier

IEC 60076-10 2001 Power transformers -- Part 10: Determination of sound levels EN 60076-10 2001 IEC 60076-11 2004 Power transformers -- Part 11: Dry-type transformers EN 60076-11 2004 IEC 60076-12 2008 Power transformers -- Part 12: Loading guide for dry-type power transformers - - IEC 60076

The Trading and Investment Strategies Interactive Qualifying Project is an in depth examination of the methods and strategies used on investable markets in order to gain long-lasting investing experience.