Professional TETRA Data ModemTMO-100 and TETRA Test SetFunk-Electronic Piciorgros GmbHStephanie Piciorgros (MBA)Claudiastrasse 551149 Cologne * Germany

Funk-Electronic Piciorgros GmbH1TETRA System Structure for Data ApplicationsData applications for utilities, water/ wastewater, gas and oil and similar applicationscan be operated in different ways. Polling protocols, polling protocols (also) usingunsolicited messaging, protocols based on serial communication and protocols based onIP communication.The TETRA infrastructure can also be used in different ways to communicate the datamessages from one or more SCADA server(s) to the data outstations: SDScommunication, Packet Switched Data and Multi Slot Packet Data.1.1Serial Protocols on TETRASerial protocols can be sent as SDS or with PD.When sending as SDS messages care should be taken, as the lengths of SDS messagesdiffer from infrastructure to infrastructure, so it may take more time to transmit withSDS when the SDS length is not using the full TETRA specification of 254 bytes perSDS message.When sending data messages with PD (that will be the user’s choice if the TETRAinfrastructure does not support SSCH and he wants to avoid too much SDS traffic onthe MCCH), the serial data will be framed into an UDP/IP data frame and sent on trafficchannels.1.2IP protocols on TETRA1.2.1TETRA Packet Data FeatureWhen using IP communication over the TETRA network from end to end (SCADAserver to data outstation), the TETRA PD feature is the best choice. In this case one ormore TETRA time slots can be used simultaneously for the data transport (three timeslots on the first carrier, four on each of the additional RF carriers on the same BS).It is important to know that on each PD traffic channel more than one MS (outstation)can operate in “semi” parallel when Packet Data Channel Sharing is enabled on theinfrastructure. Even if simultaneous operation on a single time slot is not essentiallyneeded it is important to enable the packet data channel sharing, because once the datacommunication between the SCADA server and the outstation is completed, the MSwill stay on the PDCH until the Ready Timer (MS and Infra) has been elapsed – whichusually takes 3-5 seconds. And without packet data channel sharing this timeslot will beblocked and the SwMi will report on a new data transmission request from the SCADAServer with “No Resources”.End-to-End IP communication is easy to install on TETRA infrastructures, because nospecial data gateway needs to be installed on the SCADA server side and a simple IPconnection from SCADA Server to the SwMi (please contact your Infrastructuremanufacturer for more details) without any special API can be used.1.2.2TCP and UDP ProtocolsWith Packet Switched Data or Multi Slot Packet Data, IP communication can be usedon TETRA infrastructures. But when using standard PC applications like SCADAservers and TCP/IP (Protocols like: DNP3/IP, Modbus/IP, IEC60870-5-104), thetimeouts of the TCP/IP link are often too short to guarantee a smooth and effective dataTETRA Data Modem and TETRA Test Set - Page 2 of 12

Funk-Electronic Piciorgros GmbHcommunication over the TETRA network. Therefore the TCP/IP timing has to beadjusted on the SCADA server (mostly changes in the Windows registry are needed) toensure a proper operation over TETRA.In comparison to the TCP-Protocols, UDP is more efficient for TETRA because it doesnot use any additional “logical handshaking” and it can be seen similar as serial dataprotocols, where the SCADA Server and its data timeouts control the communicationlink.1.3TETRA Data Gateway for Serial ProtocolsTo avoid a “data bottle neck” on the TETRA network air interface on the SCADAservers side (here all data to and from all outstations has to pass from the SCADAserver to the TETRA infrastructure) a TETRA Data Gateway should be used betweenSCADA server and TETRA SwMi.The TETRA Data Gateway will receive all serial data frames from the SCADA Serverand will send it using a special API (in TETRA this interface is not specified, so eachTETRA infrastructure manufacture will have its own interface) to the data outstations.1.3.1Gateway Routing TableSerial protocols will always contain (there may be some exceptions on proprietary userprotocols) a destination address. Care has to be taken to NOT USE TETRA groupcommunication but send the serial data to an individual ISSI for each single dataoutstation. Therefore the TETRA Data Server needs to convert the serial data protocolreceived from the SCADA server into a TETRA message to be sent to an individualMS.1.3.2Gateway Data CompressionIn many cases protocols for utilities, water, wastewater, gas and oil, (more) are not veryefficient and can contain a lot of “00” or “FF” or similar data. In this case datacompression is useful to minimize the load and to use the TETRA network in the mostefficient way.TETRA Data Modem and TETRA Test Set - Page 3 of 12

Funk-Electronic Piciorgros GmbH1.4Optimizing the Data Throughput on TETRA networks1.4.1Data Throughput with SDS CommunicationWhen polling data (requesting data from the outstation) - using e.g. the Modbus RTUprotocol with an SDS message of about 10-15 bytes for the poll request and 100 bytesof responding data - a complete polling cycle in a live network will need about 1,5seconds (not including the field device (PLC) latency!). During that time period theTETRA network (time slots) will not be used efficient and most of the time being inidle state not carrying any data.When splitting the SCADA Server into several polling nodes and pollingsimultaneously on the same timeslot(s) the data throughput can be increasedsubstantially. De facto up to four (depending on the infrastructure) polling nodes on asingle time slot will (also) increase the data throughput by four times. Care has to betaken in this scenario, because the single response time for a single polling request canbe increased, and a suggested value for the SCADA Server polling timeout is about 3seconds1.4.2Data Throughput with PD communicationAs already mentioned above, it is essential that on Packet Data communication, theTETRA channel sharing for all of the used packet data channels has to be enabled,otherwise each single data communication to a single outstation device will block theused timeslot (logic channel) for the pre-programmed SwMi and MS “Ready Timer”.And as the data packets can be in different sizes and the outstation can respond withdifferent latency, the Ready Timer should be chosen not too short (suggested: 5seconds).TETRA Data Modem and TETRA Test Set - Page 4 of 12

Funk-Electronic Piciorgros GmbH1.5TETRA Network architectures1.5.1SCADA Control Room linked to TETRA via Master Radio and TETRA AirInterface1.5.2SCADA Application using a SDS Gateway (no Air Interface on Control Room site)TETRA Data Modem and TETRA Test Set - Page 5 of 12

Funk-Electronic Piciorgros GmbH1.5.3SCADA Application using a Packet Data Gateway (no Air Interface on ControlRoom site)1.5.4SCADA Application using IP to IP Communication over PD or MSPD (no AirInterface on Control Room site)TETRA Data Modem and TETRA Test Set - Page 6 of 12

Funk-Electronic Piciorgros GmbH1.6TMO-100 Data Modem Features1.6.1TMO-100 Data ModemThe TMO-100 TETRA Data Modem fulfils all Requirements for Data Communicationover TETRA infrastructure.The unit is a full functional and transparent IP Data Modem that does not need anyadditional commands or actions from the connected data concentrator or PLC forestablishing the PPP context and the IP link.1.6.2TMO-100 General and Protocol Features-1.6.3TMO-100 TETRA Features-1.6.4TETRA IP Data Modem with RJ-45 10/100 T-Base connectorAutomatic PPP context set up after power onUDP and TCP/IPEmbedded router function with NAT and Port Forwarding,Port Forwarding pre sets for DBP3/IP, Modbus/IP, IEC60870-5-104Embedded Web-Server for Set up and ConfigurationCopy Configuration to/from PC using TFTP protocolTETRA RF output power class 3 (3 Watt)Automatic PPP context set upSNMP/Trap on TETRA exceptions (Power up, Network lost, Low RSSI)TETRA Black List, White List, Forbidden Cell featureRemote Configuration over the TETRA Network (Register access)TMO-100 Certificates and Approvals-CE Certified (BABT, see attached)IOP Certificates (Several Infrastructures, see www.TetraModem.com Download)Industry Canada CertifiesFCC approvedTETRA Data Modem and TETRA Test Set - Page 7 of 12

Funk-Electronic Piciorgros GmbH2Piciorgros Reference and Experience2.1Piciorgros Experience:Piciorgros (The company was founded in 1995) is a TETRA core manufacturer with itsown TETRA product since 2008 and experience in TETRA software and hardwaretechnology. Our main focus is TETRA for SCADA, Telemetry and Telecontrolapplications in Water Wastewater, Gas and Oil, Utilities, Electricity Companies andmany other applications.Deployed TETRA Projects2012201120132014SONATRACH Algeria1000 JCP Johannesburg City Power (ZA)CLP China Light and Power Hong KongBucharest AirportTETRA Projects 2014 201520142016CREOS (Luxemburg)JCP Johannesburg City Power (ZA)CLP China Light and Power Hong KongMeralco PhilippinesUAE Atlas TelecomAggrekoLogitekRoll OutPOC/OrderProd.SelectedTETRA Data Modem and TETRA Test Set - Page 8 of 122017

Funk-Electronic Piciorgros GmbH2.2Some Piciorgros SCADA Projects:Street LightingJCP – Johannesburg City Power – Johannesburg, South AfricaInfrastructure: RohillNumber of Units Sold: 1000- SCADA Application- Street Lighting Control (with Philips)- Mini SubstationsSmart MeterCLP – China Light and Power – Hong KongInfrastructure: Cassidian, Hytera (Former R&S)Final number of Modems: 700-1000- Smart Meter reading- SCADA- Other applicationsGas and OilAramco – Kingdom of Saudi Arabia (Pilot)Infrastructure: Cassidian- Cathodic ProtectionSonatrach AlgeriaInfrastructure: EtelmNumber of Units Sold: 150- Other applicationsGermany- GVG Rhein Erft, 150 Stations CP-Application- Gas Supply City of HürthTunisia- STEG-Gas, pipeline control of the international Algeria-Italy pipelineEstonia- Gas Supply and Control with Siemens PLC Type S7-315TETRA Data Modem and TETRA Test Set - Page 9 of 12

Funk-Electronic Piciorgros GmbHWater- and Wastewater MonitoringAlgeria- Control of water pumps and lift stationsAfghanistan and Korea- SCADA control of freshwater pumps and wellsSome Projects for Water- and Wastewater in Germany:- Water monitoring in chemical production Bayer-Dormagen,- Others: Wasserversorgung Altusried, Stadt Osnabrück, Kläranlage Krefeld,Stadt Duisburg, Stadt Brilon, Stadt Bielefeld, Stadt Düren, Stadt Papenburg,Stadt Waldsassen, Stadt Böblingen-SchwippeMiningGermany- Open Pit Mining ( Water Level Control ) Tagebau Hambach, GermanyTurkey- Mining Application – DMO ModeTETRA Data Modem and TETRA Test Set - Page 10 of 12

Funk-Electronic Piciorgros GmbHUtilitiesGermany- Surface Mining Hambach,Control of 80 Pump StationsChile- SAESA, sociedad austral de electricidadPower Measurement and ControlKorea- Samsung Electronics Onyang FactoryRadio Controlled Power ManagementAsia-Utility ( Energy Companies ) Pole Mounted SwitchesPresident PalaceTraffic Management Systems and Car Parking RoutingGermany- ICE Warning-System on Interstate A9, A1, A2 (Bremicker)- Car Park Routing in the following cities:Lippstadt, Ulm, Timmendorfer Strand, Düsseldorf, Ingolstadt, Limburg, ArenaHamburg, Soest, Rinteln, Gelsenkirchen,Austria- Car Park Routing Salzburg ( Siemens )- Car Park Routing Bregenz ( Dambach )Luxemburg- Car Park Routing Luxemburg ( Siemens )Switzerland- Car Park Routing Bern ( Siemens )EgyptTETRA Data Modem and TETRA Test Set - Page 11 of 12

Funk-Electronic Piciorgros GmbH-Car Park Routing Cairo ( Scheid und Bachmann )Industrial ApplicationIndia- Cement Industry: Maihar Cements, Aditya Cements, Vikram Cements,Rajashree Cements, Ultratech – Awarpur, Binani Cements, Ambuja Cements,JK Cements, ACC – Chaibasa, Ambuja Eastern,- Steel Companies: Durgapur Steel Plant, Bhilai Steel Plant,Bokaro Stelle Plant Grasim – Rawan, Tata SteelKorea- Samsung Soowon Factory:Energy Control of Steam EnergyMiddle-East Africa Region:- Cement Industry: Citi Cement Riyath,Saudi Cement Damman, Obajan Cement NigeriaTETRA Data Modem and TETRA Test Set - Page 12 of 12

Funk-Electronic Piciorgros GmbH TETRA Data Modem and TETRA Test Set - Page 3 of 12 communication over the TETRA network. Therefore the TCP/IP timing has to be adjusted on the SCADA server (mostly changes in the Windows regi

Related Documents:

5 Chakan, India Gotemba, Japan Kunshan, China Rayong, Thailand Tetra Pak Homogenizer TA 300 Tetra Pak TBA/19 0100 Tetra Pak Cap Applicator 30/Flex 0400 DreamCap Tetra Pak A3/Speed 0500 Tetra Pak Separators H20 Tetra Pak TP A3/CompactFlex 0300 Tetra Pak Accumulator Helix 30 0500 Tetra Pak PHE M10, C6 Tetra Pak Accumulator Helix 0500 Tetra Pak Straw Applicator 30 0300

4 5 TETRA TETRA TETRA B Advantages and performances Up Stream 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 100 150 200 250 300 350 k g / h A Ø 0,9 mm Ø 1,2 m Ø 1,6 mm Performance TETRA deposition rates TETRA deposition rate is the highest

WOW! Wired Modem Self-Install Guide A. Connect one end of the coax cable into an available cable outlet in your home and the other end into the modem. Your cable outlet may be on the wall or coming from the floor. Hand tighten the connections. B. Plug the power cord into the modem and into a power outlet to allow the modem to power up and begin booting. C. Use your Ethernet cable and plug it .

DB9 Female Pinout (connecting cable must have a DB9 male connector): DB9 Female Pin RS232 RS485 RS422 1 DCD (Output from radio modem) 2 TXD (output) (Serial data exiting radio modem) D (B) RXD (B) 3 RXD (input) (Serial data entering radio modem) D- (A) RXD- (A) 4 DTR (Input to Radio modem) 5 GROUND GROUND GROUND 6 DSR (Output from radio modem .

To Remove the SIM/USIM card from the USB modem i. Take down the modem cap. ii. Pull the plastic socket gently, and you can hear a click when the SIM/USIM card gets unlocked. iii. Take off the SIM/USIM card. 2. Install the microSD card into the USB modem Install microSD card in the USB modem, if you want to use it. i. Open the cover of the .

y Integrated, CableLabs-compliant DOCSIS 1.1/ 2.0 /3.0 cable modem. y Integrated cable modem port for Internet connection to cable modem service. y Four 10/100/1000 Mbps Auto-Sensing LAN ports with Auto-MDI/MDIX. y Internet connection to cable modem service via an integrated cable modem port. y One USB 2.0 port. y Dynamic Host Configur

Installation Guide - 2Wire 2701 modem Getting Your Modem Up and Running Check your modem package contents. It should contain the items shown here: Fig. 1 Familiarize yourself with the back of your modem Power - this is where you plug the power adapter Reset - to reset your modem from time to time and when connection issues ariseFile Size: 462KBPage Count: 11

27 Science Zoology Dr. O. P. Sharma Amrita Mallick Full Time 18/2009 11.06.2009 Evaluation of Genotxic Effects & Changes in Protein Profile in Muscle Tissue of Freshwater Fish Channa Punctatus Exposed to Herbicides Page 3 of 10. Sl. No. Faculty Department Name of the supervisor Name of the Ph.D. Scholar with Aadhar Number/Photo ID Mode of Ph.D. (Full Time/Part-Time) Registration Number Date of .