Technical Data SheetDuPont Tyvek 500 Xpert , ModelCHF5Technical Data SheetCATIIIT5T6ENENEN1073-2 1149-5 14126DuPont Tyvek 500 Xpert/DuPont Tyvek 500 Xpert (EcoPack). Hoodedcoverall. Ergonomic-protective design. Stitched external seams. Elasticatedwrists, ankles and face. Elasticated waist (glued-in). Tyvek zipper and flap. EcoPack available. White.CertificationsCertified according to Regulation (EU) 2016/425Chemical protective clothing, Category III, Type 5-B and 6-BEN 14126 (barrier to infective agents), EN 1073-2 (protection againstradioactive contamination)Antistatic treatment (EN 1149-5) - on both sidesStitched external seamsVery low inward leakage thanks to optimised designTyvek auto-lock zipper and zipper flap for increased protectionNEW! TYVEK Classic Xpert - ECO PACK: A new packaging concept fromDuPontPackaging(Quantity/Box)100 per box, individually packed/100 per box, 4 units of 25 (Eco Pack)Article NumberProduct SizeD14663953/D15359234 (Eco Pack)SMD14663967/D15359243 (Eco Pack)MDD14663977/D15359254 (Eco Pack)LGD14663986/D15359261 (Eco Pack)XLD14663997/D15359276 (Eco Pack)2XD14664003/D15359284 (Eco Pack)3XFull Part Number: TYCHF5SWHXP/TYCHF5SWHXBTechnical Description tyvek-500-xpert-model-chf5.pdf printed on page 1 of 7

PHYSICAL PROPERTIESPropertyTest MethodTypical ResultENEN 530 Method 2 100 cycles2 of 6 1Basis WeightDIN EN ISO 53641.5 g/m2N/AColourN/AWhiteN/AExposure to high TemperatureN/AMelting point 135 CN/AExposure to low TemperatureN/AFlexibility retained down to -73 CN/AEN ISO 7854 Method B 100000 cycles6 of 6 1Flex Cracking Resistance at -30 CEN ISO 7854 Method B 4000 cyclesN/APuncture ResistanceEN 86312.5 N2 of 6 1Resistance to Ignition 7EN 13274-4 Method 3PassN/AResistance to Water PenetrationDIN EN 2081112 kPaN/ASurface Resistance at RH 25%, inside 7EN 1149-1PassN/ASurface Resistance at RH 25%, outside 7EN 1149-1PassN/ATensile Strength (MD)DIN EN ISO 13934-182 N2 of 6 1Tensile Strength (XD)DIN EN ISO 13934-168 N2 of 6 1ThicknessDIN EN ISO 534140 µmN/ATrapezoidal Tear Resistance (MD)EN ISO 9073-427 N1 of 6 1Trapezoidal Tear Resistance (XD)EN ISO 9073-420 N1 of 6 1Abrasion Resistance7Flex Cracking Resistance71 According to EN 143252 According to EN 141263 According to EN 1073-2Instructions for Use for further information, limitations and warnings Larger than4 According to EN 1411612 According to EN 116125 Front Tyvek / Back Smaller thanN/A Not ApplicableSTD DEV Standard Deviation6 Based on test according to ASTM D-5727 SeeGARMENT PERFORMANCEPropertyTest MethodTypical ResultENNominal protection factor 7EN 1073-2Nominal protection factor: 502 of 3 3Seam StrengthEN ISO 13935-2 75 N3 of 6 1Type 5: Inward Leakage 11EN ISO 13982-2 1%N/AType 5: Inward Leakage of Airborne Solid ParticulatesEN ISO 13982-2PassN/AType 6: Resistance to Penetration by Liquids (Low Level Spray Test)EN ISO 17491-4, Method APassN/A1 According to EN 143253 According to EN 1073-212 According to EN 1161213 According to EN 116115 Front Tyvek / Back6 Based on test according to ASTM D-5727 See Instructions for Use forfurther information, limitations and warnings11 Based on the average of 10 suits, 3 activities, 3 probes Larger than Smaller thanN/A Not Applicable* Based on lowest single valueTechnical Description tyvek-500-xpert-model-chf5.pdf printed on page 2 of 7

COMFORTPropertyTest MethodTypical ResultAir Permeability (Gurley method)ISO 5636-5YesAir Permeability (Gurley method)ISO 5636-527 sN/AN/A-3Thermal Resistance, RctEN 31092/ISO 1109216.3*10Thermal Resistance, clo valueEN 31092/ISO 110920.105 cloWater Vapour Resistance, RetEN 31092/ISO 110922 According to EN 141265 Front Tyvek / Back Larger than Smaller thanEN2N/Am *K/WN/A2N/A11.3 m *Pa/WN/A Not ApplicablePENETRATION AND REPELLENCYPropertyTest MethodTypical ResultENRepellency to Liquids, Sodium Hydroxide (10%)EN ISO 6530 95 %3 of 3 1Repellency to Liquids, Sulphuric Acid (30%)EN ISO 6530 95 %3 of 3 1Resistance to Penetration by Liquids, Sodium Hydroxide (10%)EN ISO 6530 1%3 of 3 1Resistance to Penetration by Liquids, Sulphuric Acid (30%)EN ISO 6530 1%3 of 3 11 According to EN 14325 Larger than Smaller thanBIOLOGICAL BARRIERPropertyTest MethodTypical ResultENResistance to Penetration by Biologically Contaminated AerosolsISO/DIS 22611Pass1 of 3 2Resistance to Penetration by Blood and Body Fluids using Synthetic BloodISO 16603Pass3 of 6 2Resistance to Penetration by Blood-borne Pathogens using Bacteriophage Phi-X174ISO 16604 Procedure DNo classificationNo classification 2Resistance to Penetration by Contaminated LiquidsEN ISO 22610Pass1 of 6 2Resistance to Penetration by Contaminated Solid ParticlesISO 22612Pass1 of 3 22 According to EN 14126 Larger than Smaller thanPARTICLE RELEASEPropertyTest MethodTypical ResultENDry Linting Propensity, insideBS 6909128 Average particle count/17 liters of airN/ADry Linting Propensity, outsideBS 690956 Average particle count/17 liters of airN/A1 According to EN 143252 According to EN 141263 According to EN 1073-2Instructions for Use for further information, limitations and warnings Larger than4 According to EN 1411612 According to EN 116125 Front Tyvek / Back Smaller thanN/A Not ApplicableSTD DEV Standard DeviationTechnical Description tyvek-500-xpert-model-chf5.pdf printed on page 3 of 76 Based on test according to ASTM D-5727 See

Permeation Data for Tyvek 500 XpertHazard / Chemical NamePhysical State CASBT ActBT 0.1BT 1.0ENSSPRMDPRAcetic acid (30%)Liquid64-19-7immimmimm13.50.001Ammonium hydroxide (16%)Liquid1336-21-6immimmimm20.30.005Ammonium hydroxide (28% 30%)Liquid1336-21-6immimmimm16.70.014Carboplatin (10 mg/ml)Liquid41575-94-4 240 240 2405 0.0010.001Carmustine (3.3 mg/ml, 10 %Ethanol)Liquid154-93-8immimm 2405 0.30.001Caustic ammonia (16%)Liquid1336-21-6immimmimm20.30.005Caustic ammonia (28% 30%)Liquid1336-21-6immimmimm16.70.014Caustic soda (10%)Liquid1310-73-2 240 480 4806 0.0050.005Caustic soda (40%)Liquid1310-73-2imm 30 2405 0.0050.005Caustic soda (50%)Liquid1310-73-2imm 30 24060.850.01Caustic soda ( 95%, solid)Solid1310-73-2 480 480 4806 0.010.01Cisplatin (1 mg/ml)Liquid15663-27-1 240 240 2405 0.00020.0002Cyclo phosphamide (20mg/ml)Liquid50-18-0 240 240 2405 0.0020.002Dimethyl sulfateLiquid77-78-1immimmimm 1600.02Doxorubicin HCl (2 mg/ml)Liquid25136-40-9 240 240 240 0.0030.003Ethane 1,2-diolLiquid107-21-1immimmimm6.60.002Ethylene glycolLiquid107-21-1immimmimm6.60.002Etoposide (Toposar , Teva)(20 mg/ml, 33.2 % (v/v)Ethanol)Liquid33419-42-0 240 240 2405 0.01 0.01Fluorouracil, 5- (50 mg/ml)Liquid51-21-8immimm 302na0.001Formic acid (30%)Liquid64-18-6immimmimmnm0.001Ganciclovir (3 mg/ml)Liquid82410-32-0 240 240 2405 0.0050.005Gemcitabine (38 mg/ml)Liquid95058-81-4imm 60 2405 0.40.005GlycerineLiquid56-81-5 240 480 48060.030.01GlycerolLiquid56-81-5 240 480 48060.030.01Glycol alcoholLiquid107-21-1immimmimm6.60.002Hydrochloric acid (16%)Liquid7647-01-0immimmimmna0.05Hydrochloric acid (32%)Liquid7647-01-0immimmimmna0.05Hydrogen peroxide (10%)Liquid7722-84-1 10 10 480 0.010.01Hydrogen peroxide (30%)Liquid7722-84-1immimmimm 0.110.04Ifosfamide (50 mg/ml)Liquid3778-73-2immimm 240 0.50.003565Cum 480 Time 150 ISOBTAct (Actual) Breakthrough time at MDPR [mins]BT0.1 Normalized breakthrough time at 0.1 µg/cm²/min [mins]BT1.0 Normalized breakthrough time at 1.0 µg/cm²/min [mins]EN Classification according to EN 14325SSPR Steady state permeation rate [µg/cm²/min]MDPR Minimum detectable permeation rate [µg/cm²/min]CUM480 Cumulative permeation mass after 480 mins [µg/cm²]Time150 Time to reach cumulative permeationmass of 150 µg/cm² [mins]ISO Classification according to ISO 16602CAS Chemical abstracts service registry numbermin Minute Larger than Smaller thanimm Immediate ( 10 min)nm Not testedsat Saturated solutionN/A Not Applicablena Not attainedGPR grade General purpose reagent grade* Based on lowest single value8 Actual breakthrough time; normalized breakthrough time is not availableDOT5 Degradation after 5 minDOT30 Degradation after 30 minDOT60 Degradation after 60 minDOT240 Degradation after 240 minBT1383 Normalized breakthrough time at 0.1 µg/cm²/min [mins] acc. ASTM F1383Technical Description tyvek-500-xpert-model-chf5.pdf printed on page 4 of 7

Permeation Data for Tyvek 500 XpertHazard / Chemical NamePhysical State CASBT ActBT 0.1BT 1.0ENSSPRMDPRIrinotecan (20 mg/ml)Liquid100286-90-6imm 240 2405 0.10.0028Methotrexate (25 mg/ml, 0.1N NaOH)Liquid59-05-2 240 240 2405 0.0010.001Mitomycin (0.5 mg/ml)Liquid50-07-7 240 240 2405 0.00090.0009Nicotine (9 mg/ml)Liquid54-11-5 480 480 4806 0.080.08Nitric acid (10%)Liquid7697-37-2 60 120 4806na0.05Nitric acid (30%)Liquid7697-37-2immimmimm4.60.001Oxaliplatin (5 mg/ml)Liquid63121-00-6immimmimmna0.006Paclitaxel (Hospira) (6 mg/ml,49.7 % (v/v) Ethanol)Liquid33069-62-4 240 240 2405 0.01 0.01Phosphoric acid (50%)Liquid7664-38-2 480 480 4806 0.050.05Potassium chromate (sat)Liquid7789-00-6 480 480 4806 0.0050.005Potassium hydroxide (40%)Liquid1310-58-3immimm 3020.70.001Propane -1,2,3-triolLiquid56-81-5 240 480 48060.030.01Sodium acetate (sat)Liquid127-09-3imm 480 4806 0.10.05Sodium chloride (9 g/l)Liquid7647-14-5 240 240 2405 0.020.02Sodium hydroxide (10%)Liquid1310-73-2 240 480 4806 0.0050.005Sodium hydroxide (40%)Liquid1310-73-2imm 30 2405 0.0050.005Sodium hydroxide (50%)Liquid1310-73-2imm 30 24060.850.01Sodium hydroxide ( 95%,solid)Solid1310-73-2 480 480 4806 0.010.01Sodium hypochlorite (10-15% active chlorine)Liquid7681-52-9 240 240 4806 0.60.05Sodium hypochlorite(5.25-6%)Liquid7681-52-9 480 480 4806 0.0250.025Sulfuric acid (18%)Liquid7664-93-9 240 240 4806 0.050.05Sulfuric acid (30%)Liquid7664-93-9 10 240 2405 0.050.05Sulfuric acid (50%)Liquid7664-93-9imm 30 603380.01Sulfuric acid dimethyl esterLiquid77-78-1immimmimm 1600.02Thiotepa (10 mg/ml)Liquid52-24-4immimmimmna0.001Vincristine sulfate (1 mg/ml)Liquid2068-78-2 240 240 2406 0.0010.001Vinorelbine (0.1 mg/ml)Liquid71486-22-1 240 240 2406 0.02090.00209Cum 480 Time 150 ISOBTAct (Actual) Breakthrough time at MDPR [mins]BT0.1 Normalized breakthrough time at 0.1 µg/cm²/min [mins]BT1.0 Normalized breakthrough time at 1.0 µg/cm²/min [mins]EN Classification according to EN 14325SSPR Steady state permeation rate [µg/cm²/min]MDPR Minimum detectable permeation rate [µg/cm²/min]CUM480 Cumulative permeation mass after 480 mins [µg/cm²]Time150 Time to reach cumulative permeationmass of 150 µg/cm² [mins]ISO Classification according to ISO 16602CAS Chemical abstracts service registry numbermin Minute Larger than Smaller thanimm Immediate ( 10 min)nm Not testedsat Saturated solutionN/A Not Applicablena Not attainedGPR grade General purpose reagent grade* Based on lowest single value8 Actual breakthrough time; normalized breakthrough time is not availableDOT5 Degradation after 5 minDOT30 Degradation after 30 minDOT60 Degradation after 60 minDOT240 Degradation after 240 minBT1383 Normalized breakthrough time at 0.1 µg/cm²/min [mins] acc. ASTM F1383Technical Description tyvek-500-xpert-model-chf5.pdf printed on page 5 of 7

Important NoteThe permeation data published have been generated for DuPont by independent accredited testing laboratories according to the test method applicable at that time (EN ISO 6529 (method A andB), ASTM F739, ASTM F1383, ASTM D6978, EN369, EN 374-3)The data is typically the average of three fabrics samples tested.All chemicals have been tested at an assay of greater than 95 (w/w) % unless otherwise stated.The tests were performed between 20 C and 27 C and at environmental pressure unless otherwise stated.A different temperature may have significant influence on the breakthrough time.Permeation typically increases with temperature.Cumulative permeation data have been measured or have been calculated based on minimum detectable permeation rate.Cytostatic drugs testing has been performed at a test temperature of 27 C according to ASTM D6978 or ISO 6529 with the additional requirement of reporting a normalized breakthrough time at0.01 µg/cm²/min.Chemical warfare agents (Lewisite, Sarin, Soman, Mustard, Tabun and VX Nerve Agent) have been tested according to MIL-STD-282 at 22 C or according to FINABEL 0.7 at 37 C.Permeation data for Tyvek is applicable to white Tyvek 500 and Tyvek 600 only and is not applicable for other Tyvek styles or colours.Permeation data are usually measured for single chemicals. The permeation characteristics of mixtures can often deviate considerably from the behaviour of the individual chemicals.The permeation data for gloves published have been generated according to ASTM F739 and to ASTM F1383.The degradation data for gloves published have been generated based on a gravimetric method.This degradation testing exposes one side of the glove material to the test chemical for four hours. The percent weight change after exposure is measured at four time intervals: 5, 30, 60 and 240minutes.Degradation Ratings: E: EXCELLENT (0-10% Weight Change) G: GOOD (11-20% Weight Change) F: FAIR (21-30% Weight Change) P: POOR (31-50% Weight Change) NR: NOT RECOMMENDED (Above 50% Weight Change) NT: NOT TESTEDDegradation is the physical change in a material after chemical exposure. Typical observable effects may be swelling, wrinkling, deterioration, or delamination. Strength loss may also occur.Please use the permeation data provided as a part of the risk assessment to assist with the selection of a protective fabric, garment, glove or accessory suitable for your application.Breakthrough time is not the same as safe wear time. Breakthrough times are indicative of the barrier performance, but results can vary between the test methods and laboratories. Breakthroughtime alone is insufficient to determine how long a garment may be worn once the garment has been contaminated. Safe user wear time may be longer or shorter than the breakthrough timedepending on the permeation behaviour of the substance, the toxicity of the substance, working conditions and the exposure conditions (e.g. temperature, pressure, concentration, physicalstate).Latest Update Permeation Data: 5/5/2020The information provided herein corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new knowledge and experiencebecomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material used incombination with any other materials or additives or in any process, unless expressly indicated otherwise. The data provided should not be used to establish specification limits or used alone asthe basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particular purposes. SinceDuPont cannot anticipate all variations in actual end-use conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publicationis to be considered as a license to operate under or a recommendation to infringe any patent rights.The garment does not protect against ionizing radiation.This garment and/or fabric are not flame resistant and should not be used around heat, open flame, sparks or in potentially flammable environments.The information provided herein corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new knowledge and experiencebecomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated; these data may not be valid for such material usedin combination with any other materials or additives or in any process, unless expressly indicated otherwise. The data provided should not be used to establish specification limits or usedalone as the basis of design; they are not intended to substitute for any testing you may need to conduct to determine for yourself the suitability of a specific material for your particularpurposes. Since DuPont cannot anticipate all variations in actual end-use conditions DuPont makes no warranties and assumes no liability in connection with any use of this information.Nothing in this publication is to be considered as a license to operate under or a recommendation to infringe any patent rights.Technical Description tyvek-500-xpert-model-chf5.pdf printed on page 6 of 7

For further product information, literature and as well as assistance in locating a localsupplier, please visit:www.safespec.dupont.co.ukThe footnotes can be found on the SafeSPEC™ website.Copyright 2019 DuPont de Nemours Inc. All rights reserved. The DuPont Oval Logo, DuPont , and all productsdenoted with or are trademarks or registered trademarks of DuPont or its affiliates.Technical Description tyvek-500-xpert-model-chf5.pdf printed on page 7 of 7DuPont Personal ProtectionDuPont de Nemours (Luxembourg) S.àr.l.L-2984 LuxembourgTel.: 800 3666 6666 (international toll-free)Fax: 352 3666 5071E-mail: personal.protection@lux.dupont.com

Tensile Strength (XD) DIN EN ISO 13934-1 68 N 2 of 6 1 Thickness DIN EN ISO 534 140 µm N/A Trapezoidal Tear Resistance (MD) EN ISO 9073-4 27 N 1 of 6 1 Trapezoidal Tear Resistance (XD) EN ISO 9073-4 20 N 1 of 6 1 1 According to EN 14325 2 According to EN 14126 3 According to EN 1073-2 4 According to EN 14116 12 According to EN 11612 5 Front .

Related Documents:

DuPont Tyvek proven durability 10 - ageing tests results Achieve optimal airtightness and long-term performance 12 Product Portfolio 14 Application table DuPont membranes 16 DuPont Tyvek roofing underlays DuPont Tyvek Supro / Supro Plus 18 DuPont Tyvek Metal 19 DuPont

HomeWrap, the Tyvek line includes flashing and sealant materials as well as other grades of weather and air barrier sheet products including: DuPont Tyvek CommercialWrap DuPont Tyvek ThermaWrap LE DuPont Tyvek CommercialWrap D DuPont Tyvek DrainVent Rainscreen DuPont

Easy and familiar installation. DuPont Tyvek ThermaWrap R5.0—like other Tyvek weather barriers—can be installed using familiar techniques and materials, including DuPont Flashing Systems products, Tyvek Tape, Tyvek Wrap Caps and DuPont Residential Sealant. Tyvek

Tyvek Fluid Applied products should be applied when air and surface temperatures are between 25 F – 100 F. 5. Skin time of fluid applied product is 1-2 hrs. at 70 F and 50% RH. Wait 24 hrs. between coats of Fluid applied product and before applying facade. 6. Unopened fluid applied product should be stored at temperatures between 50 FFile Size: 2MBPage Count: 12Explore furtherTyvek Fluid Applied WB - Home DuPontwww.dupont.comTyvek Fluid Applied WB - Home DuPontwww.dupont.comDuPont Weather Barrier Commercial Installation Guidelinessweets.construction.comDuPont Tyvek Water-Resistive and Air Barriers Residing .www.dupont.comDuPont Tyvek StuccoWrap Data Sheet - Construction .constructioninstruction.comRecommended to you b

DuPont Tyvek Fluid Applied System Air Barrier Assembly The wall penetrations and window openings can be flashed using DuPont self-adhered flashing products or DuPont Tyvek Fluid Applied Flashing and Joint Compound . DuPont Sealant for Tyvek Fluid Applied System is used for the interior perimeter seal and for face sealing with the wall membrane.

Tyvek Fluid Applied System. ALL THE PRODUCTS YOU NEED, IN ALL THE RIGHT PLACES DUPONT WEATHERIZATION PORTFOLIO FOR . DuPont Tyvek ThermaWrap R5.0 offers the air and water management benefits of all DuPont Tyvek weather ba

Oct 15, 2015 · DuPont Tyvek CommercialWrap DuPont Tyvek CommercialWrap D DuPont Tyvek ThermaWrap DuPont Tyvek Fluid Applied Weather Barrier – nominal 25 wet mil thickness Henry Company – Air-Bloc 32MR Air-Bloc 31MR A

DuPont Froth-Pak Foam Insulation DuPont LiquidArmor Flashing & Sealant DuPont Cavitymate Ultra Wall System Great Stuff Pro Gaps & Cracks DuPont Styrofoam XPS Insulation DuPont Tyvek Fluid Applied WB DuPont Thermax Wall System DuPont Ultra SL Wall System