HVAC - Success Mep

3y ago
44 Views
4 Downloads
656.14 KB
6 Pages
Last View : 14d ago
Last Download : 3m ago
Upload by : Carlos Cepeda
Transcription

H eatingV entilationA irC onditioningHVACDESIGN&DRAFTINGClick to whatsapp: 91 7981477790, Mail: info@successmep.com,Website: www.successmep.com

INTRODUCTIONHVACIntroduction to HVACo Introduction to HvacPo Human Comfort ConditionMESSo HVAC Systems ApplicationsCECSUCCESSMEPSUBasic Componentso Basic Refrigeration Cycleo Refrigeration Cycle & its functionso Types of Compressorso Types of Condenserso Types of Expansion Valveso Types of Evaporatorso Properties of RefrigerantsAir-Conditioning Equipment’sPo ClassificationMESo Window A/C SystemsESCo Split A/C Systems UCSo Package A/C Systemso VRF/VRV Systemso Central Air-Conditioning/Chill Water Systemo DX SystemHVACCategories of Air Conditioningo All air systemo All water systemDESIGNo Air – water system&o Direct Refrigerant systemDRAFTINGPsychometrico Psychometric ChartEPo Properties of Air (DBT, WBT,SRH,SM SH etc.)CEo HVAC ProcessesCUo Using PsychometricSChartClick to whatsapp: 91 7981477790, Mail: info@successmep.com,Website: www.successmep.com

HVAC DESIGNHVACSUCCESSMEPHeat Load Calculationso Sources of HeatPo Building SurveyMESSo Heat Load FormulaCECo Finding U value for SWalls,U Roof, Glass etc.o f,andGlassetc.o Ventilation Requirementso Infiltration Concepto Heat Load Estimate (Manually & Software-E20)o Heat Load Estimate (HAP Software)o Tonnage (TR) & Air Flow (L/S) for ProjectSelection of Machineso Selection based on Heat Load Resultso Selection as perApplicationPo Selection as per Project SpecificationsMESo Placing Location ofEquipmentESCCSUAir Distribution Systemo Duct – Definition & Classificationo Aspect Ratioo Duct SizingMethodso Mc Quay DuctSizero Duct Routing &Levelso Single Line Drawingo Double Line DESIGNDrawing as per SMACNAo Selection of Diffusers& & Grilleso Duct Accessories (Sound Attenuators,VAVs, VD, FD,AD, FCetc.)o Selection ofDRAFTINGSupports & Spano Ducting Schematicso Static PressureCalculationsPMEo Selection of FANSSo BOQ for DuctingSystemCCEHVACSUClick to whatsapp: 91 7981477790, Mail: info@successmep.com,Website: www.successmep.com

HVAC DESIGNHVACSUCCESSMEPFresh Air Systemo Concept of FreshAirPo Mixed Air System – Fresh & ReturnMESo 100% Fresh Air HandlingCSystemESCo HeatRecoveryAirHandlingUnitSUo Fresh Air FanSelectionChilled Water/ Hydronic Systemo Concept of Chilled Water Systemo Classification ofPipingo GPM Calculationso Pipe Sizing of Chilled Water Systemo Valves used in Chilled Water Systemo Pipe Routing &Levelso Pump HeadCalculationPo Selection of PumpsMESo Bill of QuantitiesESCUCSVRF – Variable Refrigerant Flow Systemo Introduction to VRFo VRF for Residential & CommercialHVACInternational Standardso ASHRAEo SMACNAo ASMEo NFPAo IAQEPMSSECUCSClick to whatsapp: 91 7981477790, Mail: info@successmep.com,Website: www.successmep.com

HVAC SOFTWARESUCCESSMEPHVACHVAC Softwareo Carrier E-20 Heat Load FormPo HAP – Hourly Analysis ProgrammeMESSo BETA Software – Air OutletsCECo McQuay Duct SizerSUo McQuay Pipe Sizero Static Pressure Calculationo Pump Head Calculationo Kitchen Exhaust Systemo Master Convertero MS-Excelo Auto CAD-Expert LevelVENTILATIONPMEHVACSSECFresh Air SystemUCSo Concept of Fresh Air Systemo Mixed Air System – Fresh & Returno 100% Fresh Air Handling Systemo Heat Recovery System & HR Air Handling Unito FAHU & Fresh Air Fan SelectionHVACExhaust Air Systemo Concept of ExhaustAir System & Implementation MethodsDESIGNo Toilet Exhaust System&o Kitchen Exhaust SystemDRAFTINGo Kitchen HoodTypes and Applicationso Kitchen Hood Calculation – Manual & Softwareo Makeup Air Calculation & Fan SelectionEPMDucto Kitchen Exhaust & Makeup Air–Routing & DesigningSSECUCSClick to whatsapp: 91 7981477790, Mail: info@successmep.com,Website: www.successmep.com

VENTILATIONHVACParking Exhaust Systemo Parking Exhaust Concept, Types and Procedureso Tube Axial Concepts & Design MEPSo Central Exhaust Ducting ConceptsES & DesignCo Parking Exhaust FanSCalculationUCHVAC DRAFTINGSUCCESSMEPHVACo Single Line Drawingo Double Line Drawingo Supply air layouto Fresh air layouto Exhaust Air layoutPo Chiller Detail DrawingsMESo FCU & AHU Detail DrawingsESCC Detail Drawingso Primary & SecondaryUPumpSo As-Built Drawingo Scale Setting &Plottingo Sections & Schematic Drawingo Co-Ordination Drawingo Equipment Scheduleso International DrawingsHVACDESIGNQUALITY SURVEY&HVACDRAFTINGo Bill of Quantity – BOQo Material Submittals -MSPMEo Equipment SchedulesSSo Technical Schedules CCEo Estimation &CostingSUClick to whatsapp: 91 7981477790, Mail: info@successmep.com,Website: www.successmep.com

o McQuay Duct Sizer o McQuay Pipe Sizer o Static Pressure Calculation o Pump Head Calculation o Kitchen Exhaust System o Master Converter o MS-Excel o Auto CAD-Expert Level Fresh Air System o Concept of Fresh Air System o Mixed Air System – Fresh & Return o 100% Fresh Air Handling System o Heat Recovery System & HR Air Handling Unit o FAHU & Fresh Air Fan Selection Exhaust Air System o .

Related Documents:

technical manual direct and general support and depot level maintenance manual generator set, diesel engine driven, tactical skid mtd., 15 kw, 3 phase, 4 wire, 120/208 and 240/416 volts mep-004a mep-103a mep-113a dod models mep-005awf mep-005awe mep-004alm mep-005awm mep-015ask dod models class hertz utility 50/60

army technical manual tm 9-6115-464-24p air force technical order to 35c2-3-445-4 navy publication navfac p-8-624-24p technical manual dod model mep-004a mep-103a mep-113a dod model mep-005-awf mep-005-awe mep-004-alm mep-005-awm unit, intermediate (field) (direct support and general support) and depot maintenance repair parts and special tools .

MEP-831 GENERATOR CHARACTERISTICS, CAPABILITIES, COMPONENTS, OPERATIONS AND PMCS CLASS 1. MEP-831A CHARACTERISTICS AND CAPABILITIES. a. The MEP 831A is a 3kW (3000 watt) generator producing 60Hz of electric power. The MEP 831A is skid mounted with fork lift provisions. b. The MEP

MEP-6-6 / MEP-6-6-Ex MEP-8-6 / MEP-8-6-Ex All dimensions in inches. Dimensioned with 13 gallons dust bin without wheels. For 13 gallons dust bin with wheels, add 3.50 inches. * to be included only if a top mounted FM fan is used (transition for fan). . 150521_TD_MEP Envelope Filter_EN Author: Jacqueline Erdmann Created Date:

Revit MEP Worksets and Model Management Martin Schmid, P.E. – Autodesk ME310-1 Utilizing Revit MEP requires having a Revit Architecture model into which MEP elements can be placed. Many MEP consultants work both with architects and i

2KW 60HZ MEP-531A TAMCN B0980. 3KW 60HZ MEP-16B TAMCN B0730. 3KW 60HZ MEP-831A TAMCN B0730. 10KW 60HZ MEP-003A TAMCN B0891. 10KW 60HZ MEP-803A TAMCN B0891. . A full O & I level military TM with cataloged (NSN assigned) parts is under development and is scheduled for completion by the end of April 07. Recent Addition – B1045

MEP-005AWF WINTERIZATION KIT, FUEL BURNING 6115-00-463-9083 MEP-005AWE WINTERIZATION KIT, ELECTRIC 6115-00-463-9085 MEP-005ALM LOAD BANK KIT 6115-00-463-9088 MEP-005AWM WHEEL MOUNTING KIT 6115-00-463-9094 MEP-005MS ACOUSTIC SUPPRESSION KIT (ARMY ONLY)6115-01-234-654

economy, the MEP National Network comprises the National Institute of Standards and Technology's Manufacturing Extension Partnership (NIST MEP), 51 MEP Centers located in all 50 states and Puerto Rico, and its 1,300 trusted advisors and experts at over 400 MEP service locations, providing any U.S. manufacturer with access to