DEMOLITION REFLECTED CEILING PLAN NOTE: SEE 2/G200 .

2y ago
20 Views
2 Downloads
1.78 MB
8 Pages
Last View : 3m ago
Last Download : 3m ago
Upload by : Karl Gosselin
Transcription

SHEET NOTES - DEMOLITIONSHEET NOTES - DEMOLITION1. CONTRACTOR SHALL VISIT THE SITE AND BECOME GENERALLY FAMILIAR WITH THE EXISTINGCONDITIONS PRIOR TO COMMENCING THE WORK.2. CONTRACTOR SHALL NOTIFY THE OWNER OF ANY AND ALL DISCREPANCIES BETWEEN THEDEMOLITION DRAWINGS AND SPECIFICATIONS AND ACTUAL CONDITIONS PRIOR TO PROCEEDINGWITH THE WORK.3. REFER TO M/E/P AND FP DEMOLITION AND NEW WORK DRAWINGS FOR ADDITIONAL REQUIREMENTS.4 PROVIDE PROTECTION AGAINST MOISTURE, IMPACT AND OTHER TYPES OF DAMAGE AT ALLOPENINGS CREATED BY SELECTIVE DEMOLITION AND NEW CONSTRUCTION WORK. REPAIR ANDREPLACE DEMAGED AREAS AT NO ADDITIONAL COST TO THE OWNER.5 ALL PENETRATIONS OF EXISTING FLOORS AND FIRE RATED WALL OR SMOKE PARTITIONS SHALL BEPATCHED & REPAIRED AS REQUIRED TO MAINTAIN THE EXISTING FIRE RATING OR SMOKEINFILTRATION INTEGRITY OF THE WALL. ALL SLEEVES, WIREWAYS, CABLE TRAYS, PIPES, DUCTWORK,ETC. SHALL BE FIRE SEALED TIGHT TO THE WALL OR FLOOR PENETRATIONS TO MAINTAIN THEREQUIRED CODE COMPLIANT FIRE RATING.6 EXISTING FLOOR PENETRATIONS, WHERE PIPING, DUCTWORK, CONDUIT OR OTHER ITEMS HAVEBEEN REMOVED DURING DEMOLITION ARE TO BE FILLED WITH CONCRETE TO MATCH THE EXISTINGSURROUNDING FLOOR AND REQUIRED FIRE RATINGS.SHEET KEYNOTESSHEET NOTES - DEMOLITION7 PROTECT EXISTING INTERIOR WALLS DURING REMOVAL AND CONSTRUCTION. PROVIDETEMPORARY PROTECTION FROM DUST, NOISE, DAMAGE, ETC. AND CONSTRUCTION BARRIERS ANDOTHER SITE PROTECTION REQUIREMENTS CONSISTENT WITH THE SPECIFICATIONS SECTION, ANDDIVISION 1, GENERAL REQUIREMENTS.8 PLANS ARE DIAGRAMMATIC AND PROVIDED TO SHOW INTENT ONLY. UNLESS SPECIFICALLY NOTEDOTHERWISE ALL PARTITION ASSEMBLIES INDICATED TO BE DEMOLISHED SHALL BE DEMOLISHEDCOMPLETELY, INCLUDING PLASTER, MASONRY, GWB, STUDS, TRACKS FASTENING DEVICES, AND ALLRELATED PARTS.9 SALVAGED MATERIALS INDICATED ARE PROPERTY OF THE OWNER. TEMPORARILY STOREMATERIALS ON SITE AS DIRECTED BY THE OWNER. PROVIDE ALL NECESSARY PROTECTION AGAINSTMOISTURE, IMPACT, AND AN6Y OTHER TYPE OF POTENTIAL DAMAGE.310 CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS DAILY. DEMOLITION WORK SHALL REMAINSAFE & CLEAN FOR THE BUILDING’S OCCUPANTS & CONSTRUCTION WORKERS. OCCUPIED AREASADJACENT TO THE PROJECT WORK AREAS SHALL BE KEPT CLEAN AT ALL TIMES DURING THE WORK.11 REMOVE CEILINGS & ASSOCIATED HANGERS AND SUPPORTS IN LOCATIONS TO RECEIVE NEWCEILINGS. SEE THE FINISH SCHEDULE & THE REFLECTED CEILING PLANS.12 THE CONTRACTOR SHALL PROVIDE TEMPORARY PROTECTION, SUPPORT, BRACING SEALING ANDCAPPING OF EXISTING PARTITIONS, CEILINGS, PIPES, DUCTS, CONDUITS, ETC., SHOWN TO BEPARTIALLY DEMOLISHED. THE TEMPORARY WORK SHALL KEEP THE PARTIALLY DEMOLISHED WORKSTABILIZED. WHERE EXISTING CONSTRUCTION IS SHOWN TO BE PARTIALLY DEMOLISHED, EXTENDDEMOLITION A MINIMAL DISTANCE AS REQUIRED TO INSTALL NEW WORK 2220231HPSYCHMARINE LABPSYCHMARINE LABBIO ANIMALLABS327333335H0246REMOVE EXISTING CIRCADIAN BOX BY NEIUREMOVE EXISTING FAUCETEXISTING FLOOR DRAIN TO REMAINREMOVE RAISED FLOOR PLATFORM. SCAN THE PLATFORM FOR PIPES AND CONDUITS BEFOREDEMOLITIONREMOVE EXISTING SINK - SEE PLUMBING DRAWINGS.REMOVE EXISTING LAB DRYING BOARDREMOVE AND SALVAGE EXISTING STORAGE UNIT BY NEIUSAWCUT AND REMOVE EXISTING STRUCTURAL GLAZED FACING TILE WALL FOR NEW DOOROPENING.REMOVE AND RE-INSTALL EXISTING MOBILE METAL TABLE BY NEIUREMOVE AND RELOCATE EXISTING 6' X 2' METAL RACK BY NEIUREMOVE AND SALVAGE EXISTING COMPUTER BOX BY NEIUEXISTING GREEN HOUSE ENCLOSURE. TO REMAIN.REMOVE AND SALVAGE EXISTING TABLE BY NEIUREMOVE, SALVAGE AND REINSTALL EXISTING WALL-MOUNTED EYEWASHREMOVE AND RE-INSTALL EXISTING CABINET BY NEIUREMOVE EXISTING RACK BY NEIUREMOVE AND RE-INSTALL EXISTING FISH TANK & RACK BY NEIUREMOVE AND RE-INSTALL EXISTING FRIDGE BY NEIUREMOVE PORTION OF WALL FOR NEW DUCT WORK. SEE MECHANICAL DRAWINGS.CUT ROOF TO ACCOMODATE NEW ROOF THROUGH PLUMBING VENT, SEE PLUMBING.SAW CUT STRUCTURAL GLAZED FACING TILE WALL, TO ACCOMODATE COLD WATER FEEDER FORFISH TANKS, SEE PLUMBING.REMOVE EXISTING FINISH CEILING, CEILING SOFFITS, CEILING DEVICES AND FIXTURESREMOVE EXISTING CASEWORK. REMOVE AND SALVAGE EXISTING STAINLESS STEELCOUNTERTOP FOR NEW WORK.REMOVE AND RE-INSTALL EXISTING FARADAY BOX BY NEIUREMOVE AND RE-INSTALL EXISTING TABLE BY NEIUREMOVE AND RE-INSTALL EXISTING TOOLBOX BY NEIUREMOVE AND RE-INSTALL EXISTING CRYO BY NEIUREMOVE AND RE-INSTALL EXISTING COMPUTER BY NEIUEXISTING GREEN HOUSEREMOVE COVER ONLY OF EXISTING ROOF HATCH. HATCH FRAME OPENING AND CAP FLASHINGTO REMAIN.EXISTING VENTS TO REMAINREMOVE EXISTING ROOF EXHAUST, SEE MECHANICALREMOVE EXISTING WALL-MOUNTED HW, CW, A & S TO MAIN AND CAP, SEE PLUMBING DRAWINGS.EXISTING ROOF TO REMAIN, TYPICALREMOVE EXISTING DOOR, EXISTING FRAME TO REMAINREMOVE EXISTING FLOOR FINISH AND PREP IT TO TAKE NEW FLOOR FINISH, TYPICAL.TEMPORARILY REMOVE AND SALVAGE EXISTING CEILING GRID AND TILES TO ACCOMODATEMECHANICAL WORK. INSTALL NEW MECHANICAL WORK. PROTECT EXISTING FIXTURES, FINISHES,EQUIPMENT, FURNISHING DURING REMOVAL. RE-INSTALL EXISTING CEILING TILES. PATCH, CLEANAND REPAIR ANY DAMAGE TO THE EXISTING SPACE. SEE MECHANICAL DRAWINGS.REMOVE EXISTING WALL MOUNTED FIXTURES, EXISTING WIREMOLD AND EXISTING OUTLETS,TYPICAL - SEE ELECTRICAL, AND MECHANICAL DRAWINGS.t 312.440.2300f 312.440.2303www.baileyedward.com35 East Wacker DrSuite 2800Chicago, IL60601-2308 2013 Bailey Edward DesignDesign Firm License No. 184-0019621100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563630.527.2320 FAX: 630.527.2321www.kjww.comExperience you can build on. TM PROJECT # 13.0146.00Illinois Design Firm Registration #184-000973ENGINEERINGCONSULTANTSKJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/ORDATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOTBE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. 2013 KJWW, P.C.REFERENCE SCALE IN INCHES1203PROJECT NOTESACORRIDOR383DEMOLITION RCP LEGEND0245EXISTING LIGHT FIXTURE TO BE REMOVED; REF. TOELECTRICAL PLANSB2DEMOLITION REFLECTED CEILING PLAN1/4" 1'-0"02'4'EXISTING MECH. SUPPLY DIFFUSER TO BE REMOVED;REF. MECHANICAL PLANSNOTE: SEE 2/G200 CONSTRUCTIONCOORDINATION PLAN FOR SECONDFLOOR CEILING DEMOLITION PLANEXISTING MECH. RETURN DIFFUSER TO BE REMOVED; REF.MECHANICAL PLANS8'INDICATES EXTENT OF DEMOLITION WORKREQUIRED BY KEYNOTE THROUGHOUT ROOMOR ate4/24/20135/2/2013ISSUED FOR BIDISSUED AS ADDENDUM #1EXISTING HEAT DETECTOR TO BE REMOVED.AREA OUTSIDE THE EXTENT OF INTERIOR FINISHWORKGREENHOUSE202305No.Revision ScheduleDescription0203SITE PLAN\\be-fs\user documents\pgongal\My Documents\1302-13-01 NEIU DoorRemain CENTRAL PGongal.rvt4/26/2013 4:25:08 PMDEMOLITION PLAN LEGEND022602120211EXISTING WALL TO BE DEMOLISHED0201020802250225PSYCHMARINE LAB02040217EXISTING WALL TO REMAINBERNARD J. BROMMEL HALL(PROJECT BUILDING)020133302270242EXISTING DOOR AND FRAME TO REMAIN0205382 SF023102280246023302460213EXISTING DOOR AND FRAME TO BEDEMOLISHED02460217BIO ANIMALLABS021002440203020302060244335EXISTING TO BE DEMOLISHEDINDICATES EXTENT OF DEMOLITION WORKREQUIRED BY KEYNOTE THROUGHOUT ROOMOR SPACE389 SF02210220N02440205PSYCHMARINE 3270210KEY PLAN - THIRD FLOOR0207021802150242AREA OUTSIDE THE EXTENT OF INTERIOR FINISHWORKPROJECT AREA02095500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280PROJECTAVIVARIUM & MARINEORGANISMS RENOVATION0234024302240215024302190243BE # 1302-13-01NEIU # 11-0333-0213CORRIDOR383BUILDING ID/NAME: BERNARD J. BROMMEL HALLARCHITECTURAL DEMOLITIONPLANSB3DEMOLITION ROOF PLAN1/4" 1'-0"02'4'18'DATEDEMOLITION PLAN1/4" 1'-0"02'4'8'4/24/2013DRAWN BYPGCHECKED BYMPSCALEAs indicatedSHEET No.D1005 of 23 SHEETS

SHEET NOTES - PLANSHEET NOTES - PLAN1 CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH THE EXISTING CONDITIONSPRIOR TO COMMENCING THE WORK. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS,ELEVATION HEIGHTS, CONSTRUCTION AND BUILDING SYSTEMS IN THE FIELD AND PRIOR TOPROCEEDING WITH THE WORK.2 CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY AND ALL DISCREPANCIES BETWEEN THECONTRACT DOCUMENTS AND EXISTING CONDITIONS PRIOR TO PROCEEDING WITH THE WORK.3 ROOM LAYOUTS AND CONFIGURATIONS AND FOR AREAS OUTSIDE OF THE CURRENT WORK ARESHOWN FOR REFERENCE ONLY. EXISTING CONSTRUCTION IS BASED UPON LIMITED SURVEYS BYTHE ARCHITECT AND INFORMATION PROVIDED BY THE OWNER. FIELD VERIFICATION PRIOR TOCOMMENCEMENT OF CONSTRUCTION IS REQUIRED.4 IN AREAS OF REMOVAL AND WHERE NEW WORK AND/OR FINISHES ARE NOT SCHEDULED,CONTRACTOR SHALL REPAIR, PATCH AND CLEAN WALLS, FLOORS, WALL BASES, AND CEILING ASREQUIRED TO MATCH EXISTING FINISHES TO BE FLUSH, SMOOTH, AND MATCH ADJACENTMATERIALS IN ALL RESPECTS. RELOCATE LIGHT FIXTURES AND OTHER CEILING AND WALLMOUNTED DEVICES WHERE NEW PARTITIONS ARE SHOWN ADJACENT TO AREAS NOTSCHEDULED FOR NEW FINISHES.5 PREPARE ALL EXISTING SURFACES TO REMAIN PROVIDING CLEAN SMOOTH SURFACES TORECEIVE SCHEDULED FINISHES. LEVEL FLOOR SLAB SURFACES AS REQUIRED TO PROVIDE AFLAT, LEVEL SURFACE FOR FLOORING INSTALLATIONS. REFERENCE THE FINISH SCHEDULESHEET AND THE FINISH PLANS SHEETS FOR RELATED REQUIREMENTS.SHEET KEYNOTESSHEET NOTES - PLAN6 WHERE EXISTING MASONRY PARTITIONS ARE REMOVED FOR NEW OPENINGS & WHEREEXISTING OPENINGS ARE ENLARGED, PATCH AND FINISH NEW OPENINGS AS REQUIRED BYTOOTHING NEW OPENING TO MATCH EXISTING PARTITIONS. MAINTAIN EXISTING ACOUSTICPERFORMANCE AND REQUIRED FIRE AND SMOKE RATINGS.7 CLEAN AND PREPARE FOR NEW FINISHES EXISTING SURFACES INDICATED TO REMAIN.COORDINATE WITH THE VA REMOVAL AND DISPOSAL OF UNWANTED SIGNAGE, FIXTURES,HARDWARE, ETC. ON EXISTING SURFACES TO MATCH EXISTING SUBSTRATES AND PROVIDE ANADDITIONAL PRIME PAINTED COATING ON ALL REPAIRS PRIOR TO REFINISHING AS SCHEDULED.COORDINATE WITH THE REQUIREMENTS OF THE FINISH SCHEDULE.8 LEVEL EXISTING FLOOR SURFACES SCHEDULED WITH NEW FLOOR FINISHES AS REQUIRED TOPROVIDE LEVEL AND FLAT FLOOR SURFACES.9 FURNISH AND INSTALL REINFORCEMENT REQUIRED FOR WALL, FLOOR, OR CEILING MOUNTEDITEMS, INCLUDING OWNER & VENDOR MOUNTED ITEMS.10 ALL PENETRATIONS OF FLOORS AND FIRE RATED WALL OR SMOKE PARTITIONS SHALL BEPATCHED & REPAIRED AS REQUIRED TO MAINTAIN THE EXISTING FIRE RATING OR SMOKEINFILTRATION INTEGRITY OF THE FLOOR AND WALL ALL SLEEVES, WIREWAYS, CABLE TRAYS,PIPES, DUCTWORK, ARE TO BE FIRE SEALED TIGHT TO THE WALL OR FLOOR PENETRATIONS TOMAINTAIN THE REQUIRED CODE COMPLIANT FIRE RATING.11 DO NOT APPLY NEW FINISHES TO EXISTING WALL AND CEILING MOUNTED DEVICES, FIXTURES,COVER PLATES, SIGNAGE, HARDWARE, ITEMS, ETC, LOCATED ON EXISTING SURFACESSCHEDULED TO BE REFINISHED. EXISTING ITEMS THAT ARE NOT REMOVABLE SHALL BECAREFULLY TAPED, OR OTHERWISE COVERED DURING REFINISHING. WHERE NEW FINISHES AREAPPLIED EXISTING FINISHES NO LONGER VISIBLE SURROUNDING EXISTING ITEMS.12 PROVIDE HEAVY GAUGE METAL STRAPPING OR FIRE RATED BLOCKING WITHIN THE WALL CAVITYFOR ALL WALL MOUNTED EQUIPMENT, GRAB BARS, AND CABINETS.13 INSTALL SEALANT AND BACKER ROD AT ALL HORIZONTAL EDGES WHERE NEW AND/OR EXISTINGWALLS MEET THE STRUCTURE ABOVE. ALSO ADD SEALANT AND BACKER ROD TO VERTICALEDGES WHERE NEW AND/OR EXISTING WALLS MEET AND AT EXISTING DOOR LINTELS.14 PATCH AND REPAIR EXISTING WALLS. THE TOTAL AMOUNT OF PATCHING IS ASSUMED TO BEAPPROXIMATELY 21 LINEAL FEET.3ANIMALHOUSING 071211121222012202220322046335 AEQ8' - 0"EQ220522062207220922102' - 0"HOLDEQ090512' - STICLABEXISTING FLOOR DRAIN TO REMAINEXISTING GREEN HOUSE ENCLOSURE. TO REMAIN.EXISTING GREEN HOUSEEXISTING VENTS TO REMAINEXISTING ROOF TO REMAIN, TYPICALPATCH AND SEAL WALL AT AREA OF MECH DUCT REMOVAL. MAINTAIN THE ASSUMED1-HR FIRE RATING OF WALL. VIF.NEW INSULATED ROOF HATCH COVER.NEW INSULATED FIBERGLASS DOOR, SEE DOOR SCHEDULENEW LAB CASEWORK, UPPER AND BASE CABINETNEW LAB CASEWORK, UPPER AND BASE CABINET. NEW SOLID SURFACE COUNTERTOPSOLID SURFACE SPLASH GUARD.NEW ACOUSTIC CEILING TILENEW DRYWALL CEILINGSCHEDULED FLOOR FINISHREINSTALL EXISTING CEILING SYSTEM AND CEILING MOUNTED DEVICES. REFER TOSHEET D100.2' H X 1'-6" W TACK BOARDUPPER STORAGE CABINET WITH ADJUSTABLE SHELVESEXISTING GARBAGE CONTAINERWALL-HUNG GLASSWARE PEGBOARDS, 18"X24" MODEL NO. 52L80500.FULL-HEIGHT LAB CASEWORK CABINETSNEW PLUMBING VENT THROUGH ROOF, SEE PLUMBING.EYE WASH, COUNTER TOP MOUNTED. SEE PLUMBING.SINK WITH IR SENSOR AND MANUAL SPRAYER, SEE PLUMBING.RE-INSTALL EXISTING STAINLESS STEEL COUNTERTOP AND INTEGRAL SINK. INSTALLNEW FAUCETS AND FOOT PEDAL CONTROL. SEE PLUMBING.NEW FLOOR DRAIN, SEE PLUMBING DRAWING.RECONNECT AND RE-INSTALL EXISTING WALL-MOUNTED EYEWASH, SEE PLUMBING.SINK WITH FOOT PEDAL CONTROL AND MANUAL SPRAYER, SEE PLUMBING DRAWING.WALL MOUNTED WASH-DOWN HOSE, SEE PLUMBING.PATCH AND FILL EXISTING PLUMBING PIPES. CUT CONCRETE. VERIFY NOT INOPERATION AND PLUG PIPING.NEW ROOF EXHAUST OVER PRE MANUFACTURED CURB, SEE MECHANICAL SPEC ANDDRAWING.t 312.440.2300f 312.440.2303www.baileyedward.com35 East Wacker DrSuite 2800Chicago, IL60601-2308 2013 Bailey Edward DesignDesign Firm License No. 184-0019621100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563630.527.2320 FAX: 630.527.2321www.kjww.comExperience you can build on. TM PROJECT # 13.0146.00Illinois Design Firm Registration #184-000973ENGINEERINGCONSULTANTSKJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/ORDATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOTBE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. 2013 KJWW, P.C.0904H8' - 0"OC333PROCEDURELABHPROJECT NOTES3350904OC3HPSYCHMARINEHOUSING327HREFERENCE SCALE IN INCHES12009050904H8' - 6"8' - 6"8' - 0"8' - 0"AANIMALHOUSING 2CORRIDOR335 B3830915REFLECTED CEILING PLAN LEGENDB2x4 LIGHT FIXTURE2THIRD FLOOR REFLECTED CEILING PLAN1/4" 1'-0"02'4'MECH. SUPPLY DIFFUSERNo.12DateRevision ScheduleDescription4/24/20135/2/2013ISSUED FOR BIDISSUED AS ADDENDUM #1MECH. RETURN DIFFUSER8'RECESSED CAN LIGHT FIXTURE343512' - 0"5A400023048"28' - 6"11 1/8"56' - 2 7/8"614' - 0NEW WALLEXISTING DOOR AND FRAME TO REMAIN2202PROCEDURELABNEW DOOR AND rsityKEY PLAN - THIRD FLOORPROJECT AREAXEQ-205333327-AAEXISTING WALL TO REMAIN1211EQ-201XEQ-006A2203W1AW1ABERNARD J. BROMMEL HALL(PROJECT BUILDING)FLOOR PLAN LEGENDXEQ-2074XEQ-209A4005' - 0 7/8"335 A90903XEQ-2065' - 0"2201XEQ-20518' - 3 3/8"22108335-A8' - 2 1/2"XEQ-0052210A2009' - 2 1/8"117EQ-100VIF3SimNEXISTING CEILING TILE TO REMAIN1206EQ-200W2AXEQ-108130203A200ANIMALHOUSING 12' - 6"09028' - 9 1/4"XEQ-1081012XEQ-0042' - 4 1/4"3"09140914VIF0242W2A090209143' - 3"0233327-B18' - 3 3/8"A400EQ-201XEQ-107W2AVIF6' - 3"1W2A5' - 3"\\be-fs\user documents\pgongal\My Documents\1302-13-01 NEIU DoorRemain CENTRAL PGongal.rvt4/26/2013 4:26:29 PMSimSITE PLAN2X2 ACOUSTICAL CEILING TILE0802XEQ-003OCCUPANCY SENSORGYPSUM BOARD CEILING3450212HEAT DETECTOR1203121222062207120322051203ANIMALHOUSING 2335 BCORRIDOR383BTELEPHONE: 773/442-5230FASCIMILE: 773/442-5280PROJECT335VIVARIUM & MARINEORGANISMS RENOVATION230204015500 NORTH ST. LOUIS AVENUECHIAGO, IL 606250401BE # 1302-13-01NEIU # 11-0333-0213BUILDING ID/NAME: BERNARD J. BROMMEL HALLARCHITECTURAL FLOOR PLANSB3ROOF PLAN1/4" 1'-0"012'4'8'DATETHIRD FLOOR PLAN1/4" 1'-0"02'4'8'4/24/2013DRAWN BYAJLCHECKED BYMPSCALEAs indicatedSHEET No.A1006 of 23 SHEETS

ACT-1ACT-1GWB, PT-1GWB, ING COLUMNS - PT1EXISTING COLUMNS - PT1EXISTING COLUMNS - PT12ROOM FINISH LEGENDMATERIALTYPE / CODEMATERIALMANUFACTURERMATERIAL DESCRIPTIONROOM NAMEWIDTH327327327PSYCH MARINE DIAGONISTIC LAB 327-APSYCH MARINE DIAGONISTIC LAB 327-BPSYCH MARINE DIAGONISTIC LAB 3454' - 0"3' - 0"4' - 0"7' - 0"7' - 10"7' - 0"1 3/4"1 3/4"2"AAAAWDWDFRP333335335 A335 BPSYCH MARINE HOUSINGPROCEDURE LABANIMAL HOUSING 1ANIMAL HOUSING 23' - 6"4' - 0"3' - 0"3' - 0"7' - 10"7' - 10"7' - 10"7' - 10"1 3/4"1 3/4"1 3/4"1 3/4"AAAAWDWDWDWD333335335-A335-BMATERIAL 1LG-1PB-1SC-1WC-1WC-2WC-3WC-4WC-5MODEL2x2, WHITE115J6320CASEWORK SCHEDULEWIDTHDEPTHFlush Overlay Steel Base J3680806J792L806J892LFO 423L706J523L706J623L706J823LCLEAN ROOM TILE,SCRUBABLESTONEHENGE(ROCKTREAD BASIS OF DESIGN)STONEHENGE(ROCKTREAD BASIS OF DESIGN)EIDER WHITE (SHERWIN WILLIAMS BASIS OF DESIGN)FAWN BRINDLE (SHERWIN WILLIAMS BASIS OF DESIGN)COLLONADE GRAY (SHERWIN WILLIAM BASSIS OF DESGIN)DARK KHAKI (THERMO FISHER BASIS OF DESIGN)SMOKE ICE (FORMICA BASIS OF DESIG)2DESCRIPTIONHEADJAMBFlush Overlay Steel Base CabinetFlush Overlay Steel Base CabinetFlush Overlay Steel Base CabinetFlush Overlay Steel Base DrawersFlush Overlay Steel Base CabinetFlush Overlay Steel End Support PanelFlush Overlay Steel Tall CabinetFlush Overlay Steel Tall CabinetFlush Overlay Steel Kneespace Panel and RailsLeg AssemblyGlassware PegboardFlush Overlay Steel Fillers and ScribesFlush Overlay Steel Wall CabinetFlush Overlay Steel Wall CabinetFlush Overlay Steel Wall CabinetFlush Overlay Steel Wall CabinetFlush Overlay Steel Wall Cabinet123Class C, 45minVIF FRAME SIZE.Class C, 45minVIF FRAME 1.22.12.1Class C, 45minClass C, 45minVIF FRAME SIZE.VIF FRAME GEXISTING223' - 0"5' - 0"3' - 0"2' - 0"4' - 0"2' - 0"7/8"3' - 6"4' - 0"1' - 6"1"2' - 0"2' - 0"2' - 6"3' - 0"4' - 0"1' - 9 1/8"HEIGHT2' - 11 1/4"COUNT2FINISHPT-41' - 9 1/8"1' - 9 1/8"1' - 9 1/8"1' - 9 1/8"1' - 9 1/8"2' - 4 7/8"1' - 10"1' - 10"1' - 9 1/8"2' - 11 1/4"2' - 11 1/4"2' - 11 1/4"2' - 11 1/4"2' - 11 1/4"2' - 11 1/4"7' - 0 5/8"7' - 0 5/8"2' - 11 ' - 9 5/8"1"2"1' - 1"1' - 1"1' - 1"1' - 1"1' - 1"2' - 11 1/4"2' - 0"2' - 11 1/4"2' - 1 1/4"2' - 1 1/4"2' - 1 1/4"2' - 1 1/4"2' - 1 1/4"11611431PT-4PT-4PT-4PT-4PT-4PT-4PT-4PT-4SEE SCHEDULE2"2"SEE SCHEDULEPROVIDED BYFish tank system (Z-Hib Mini)Bedding stationAnimal cage racksMobile Computer StationTool boxCyroFaraday boxFaraday boxTableFull-height cabinetDigital Scale 1Digital scale 2Sonic cleanerPH meterSide warmerFlammable storageAcid storageRefrigeratorRacksTankDigital scaleCircadian box 1Aquatic Habitat, BenchtopTechiplast, 33333333333333333333120V -10.5A115V - 8.6 FCIOFCIOFCIOFCIOFCIOFCIOFCIOFCIOFCIOFCIOFCIFOOT PADELCONTROLLOCKLOCKLOCKDOOR TYPE: A8LOCKDOOR TYPE: AAFRAME TYPE: 1XEQ-202Circadian box 2Existing333120VOFCIDesktop computerMobile metal tableBedding binFood hopperMorris water mazeCage rackSmall lab -OFCIOFCIOFCIOFCIOFCIOFCIOFCIDOOR & FRAME TYPES1/2" 1'-0"06"VARIES, VIF (4 7/8")TURN-UP STUD RUNNER & 1/4"EXPANSION ANCHOR TO EXIST.MASONRY @ MASONRY JAMBS,V.I.F.1'LOCKLOCKREFER TO TYP. FRAMINGELEVATIONS FOR REQUIREDFRAMING OVER OPENING.SAW CUT THE BRICK TOACCOMMODATE METALANGLE FLANGES.1/2"L 3-1/2x3-1/2x5/16 METALANGLE LINTEL, EXTEND4" OR 6" MIN. BOTH SIDEOF THE DOOR.EXISTING GLAZED FACINGTILE WALL, SAW CUTOPENING TYP. DO NOTOVER CUT.SEALANT, BOTHSIDES TYP.LOCKLOCK1/2"SEALANT - TYPICAL BOTH SIDESGROUT FRAME SOLID, TYP.HM FRAMEGROUT HEADLOCKLOCKSCHEDULED DOORHM FRAMENo.12SCHEDULED DOORCOMMENTS5(Owner filter). Future installationExhaust and air filter in the equipmentQuantity 23DOOR HEAD DETAIL - EXISTING WALL3" 1'-0"0With operable lidOpen RHS3"6"ADJ. WALL4"Quantity 2Quantity 10, filter and heater in each tank3" 1'-0"02HM FRAME4" TYP.SITE PLANGROUT FRAME SOLID, TYP.NFRAME ANCHOR - REFER TOSPECIFICATIONS FOR NUMBER ANDSPACINGSCHEDULED DOORBERNARD J. BROMMEL HALL(PROJECT BUILDING)DOOR JAMB DETAIL - STUD WALL3" 1'-0"0DOUBLE METAL STUD JAMBSCHEDULEDDOOR03"EXTEND RUNNER TRACK FLANGES 1 5/8"MIN EACH SIDE BEYOND FACE OF JAMB.PROVIDE 3/4" LOW PROFILE #10 PANHEAD SHEET METAL SCREWS EACH SIDEOPENING HEAD FRAMING6"HEAD TRACK FRAMING1 1/2" 1'-0"06"NortheasternIllinoisUniversityCONTINUOUS RUNNERTRACK ATTACHED TONESTED STUDPROJECTCONTINUOUS METALSTUD NESTED INTOBOTTOM RUNNERTRACKNEIU # 11-0333-0213TYPICAL HEADJAMB AT HEAD13"CONTINUOUS RUNNERTRACK ATTACHED TONESTED STUDREFER TO WEB CONNECTIONNOTE UNDER JAMB/HEAD TYPE 1,THIS DETAILDOOR JAMB DETAIL - EXISTING WALLCONTRACTOR FURNISHEDCONTRACTOR INSTALLEDOWNER FURNISHEDOWNER INSTALLED6"HOLLOW METAL FRAME2"COUNTERSUNK FLATHEADBOLT WITH CAPEQUIPMENT LEGENDCFCIOFOI3"SEALANT, BOTH SIDESFRAME ANCHOR3" 1'-0"ISSUED FOR BIDISSUED AS ADDENDUM #1ADJ. WALLSEALANT, BOTH SIDES44/24/20135/2/20132"GROUT FRAMESOLID, TYPOn countertop, new locationOn countertop, new locationOn countertop, new locationOn countertop, new locationOn countertop, new locationYellow box, below countertopBlue box, below countertopDateRevision ScheduleDescriptionDOOR HEAD DETAIL - STUD WALL20 GA DOUBLE METAL STUDASSEMBLY. REFER TO TYPICALFRAME ELEVATIONS.STAGGER SCREW GYP BD TOEACH STUD @ 16" O.C.VERTICAL, TYPICALEXISTING STRUCTURALGLAZED FACING TILEStored in closet and used when neededQuantity 2Blue equiment next to scale3FRAME TYPE: 2KNOCKDOWN TYPEVARIES, VIF (7 5/8" ASSUMED)Cabinet has built-in exhaust but needs to have someclearance to accommodate the internal exhaustCabinet has built-in exhaust but needs to have someclearance to accommodate the internal exhaustQuantity 2Quantity 2REFERENCE SCALE IN INCHES1201/2" TYP.POWER REQ1100 WARRENVILLE ROAD, SUITE 400WNAPERVILLE, ILLINOIS 60563630.527.2320 FAX: 630.527.2321www.kjww.comExperience you can build on. TM PROJECT # 13.0146.00Illinois Design Firm Registration #184-000973ENGINEERINGCONSULTANTSKJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/ORDATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOTBE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTENAPPROVAL AND PARTICIPATION OF KJWW ENGINEERING. 2013 KJWW, P.C.VARIES, VIF (4 7/8")ROOM 2013 Bailey Edward DesignDesign Firm License No. 184-001962PROJECT NOTESWELD 5/16" THICK METALPLATE TO THE 209XEQ-21035 East Wacker DrSuite 2800Chicago, IL60601-2308COMMENTSVARIES, VIF (7 5/8" ASSUMED)\\be-fs\user documents\pgongal\My Documents\1302-13-01 NEIU DoorRemain CENTRAL PGongal.rvt5/2/2013 5:34:48 PMMANUFACTURERt 312.440.2300f 312.440.2303www.baileyedward.comWD WOODHM HOLLOW METALFRP FIBERGLASS REINFORCED POLYESTER2"EQUIPMENT SCHEDULE -- SEE ALSO SPECIFICATION SECTION 11 00 00DESCRIPTIONCOMMENTS2LOW VOCLOW VOCLOW VOCNOTE: BASIS OF DESIGN: THERMO FISHER SCIENTIFIC, SEE SPEC SECTION 123553EQUIPMENTNUMBERFIRE RATINGEXISTING EXISTING EXISTINGPT-354EXISTING EXISTING EXISTING2"SEE SPEC 096700SEE SPEC 096700SEE SPEC 099123SEE SPEC 099123SEE SPEC 099123SEE SPEC 123553SEE SPEC 123553FINISH1EXISITNG2HMEXISTING EXISITNGSEE SCHEDULEINTEGRAL COVE BASEEPOXY FLOOR FINISHEPOXY PAINT--MAIN FIELD WALL COLOREPOXY PAOINT-- ACCENT WALL COLOREPOXY PAINT - DOOR FRAME COLORMETAL CASEWORK COLORSOLID SURFACE MATCH EXISTINGMATCH EXISTNGMANUF.STANDARDMATCH EXISTINGMATCH EXISTINGMATCH EXISTINGMATCH EXISTING2"1' - 0"SEE SCHEDULESEE SPEC 0951133' - 0"SEE SCHEDULEACOUSTICAL CEILING TILEFINISHNOTE: SEE SPEC SECTION 08 71 00 FOR HARDWARE SETMANUFACTURER MODEL, SIZE & COLORSEE DWARE SETPT-2FRAME4"EXISTINGCOMMENTSDOORSEE SCHEDULEACT-1WESTBASEFINISH2"333335335 A335 BPSYCH MARINE DIAGONISTICLABPSYCH MARINE HOUSINGPROCEDURE LABANIMAL HOUSING 1ANIMAL HOUSING 2CEILING FINISHFLOORFINISHDOOR NUMBER327ROOM NAMEDOOR SCHEDULEROOM NUMBERROOM NUMBERROOM FINISH SCHEDULEWALL FINISHNORTHSOUTHEAST6"1'5500 NORTH ST. LOUIS AVENUECHIAGO, IL 60625TELEPHONE: 773/442-5230FASCIMILE: 773/442-5280VIVARIUM & MARINEORGANISMS RENOVATIONBE # 1302-13-01BUILDING ID/NAME: BERNARD J. BROMMEL HALLCASEWORK, DOOR, EQUIPMENT &FINISH SCHEDULESDATE4/24/2013DRAWN BYPGCHECKED BYMPSCALEAs indicatedSHEET No.A3008 of 23 SHEETS

EXHAUST FAN SCHEDULEGENERAL VENTILATION NOTESELECTRICALTAGNAMEAREASERVEDEF-1LAB PMDRIVE(NOTE F) TYPE(NOTE LER/STARTERDISCONNECTBYTYPEBYTYPE(NOTE A) (NOTE B) (NOTE A) (NOTE C)MFRNFATC1. CONTRACTOR SHALL COORDINATE DUCTWORK ANDEQUIPMENT LOCATIONS WITH ALL TRADES AND EXISTINGCONDITIONS.2. CONTRACTOR SHALL COORDINATE EXISTING SYSTEM SHUTDOWNS WITH OWNER.MANUFACTURER MODEL REMARKSFVCOOKACEBNOTE 1, 23. CUT AND PATCH WALLS AS REQUIRED FOR INSTALLATION OFDUCTWORK.NOTES:1. PROVIDE WITH CURB ADAPTOR TO OFFSET W/ THROAT OF NEW FAN.2. INTERLOCK FAN OPERATION WITH EXISTING AHU SERVING SPACE.3456GREENHOUSETAGNAME345CD-1EG-1GRILLES REGISTERS & DIFFUSERS N.) REQUIRED FINISH MANUFACTURERMATERIAL CONFIGURATION (NOTE 1)STEELSTEELPANEL FACE35 DEGREEDEFLECTIONLAY-IN1 1/4"SEE DWG.SEE DWG.24x24INLET 2NONOWHITEWHITETITUSTITUS4. DRAWINGS SHOWING LOCATIONS OF EQUIPMENT, DUCTWORK,ETC. ARE DIAGRAMMATIC AND MAY NOT ALWAYS REFLECTACTUAL INSTALLATION CONDITIONS. DRAWINGS SHOW THEGENERAL ARRANGEMENT OF ALL DUCTWORK, EQUIPMENT,ETC., AND MAY NOT INCLUDE ALL OFFSETS AND FITTINGSREQUIRED FOR COMPLETE INSTALLATION. THE DRAWINGSSHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDINGCONSTRUCTION AND THE WORK OF OTHERS WILL PERMIT.MODELNOTES6. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS ANDCLEARANCES FROM ARCHITECTURAL, STRUCTURAL,SUBMITTALS, AND OTHER APPROPRIATE DRAWINGS ORPHYSICALLY AT SITE. READ ALL SPECIFICATIONS. REVIEW ALLDRAWINGS, INCLUDING THOSE OF OTHER TRADES.OMNI350RNOTES:1. CONTRACTOR SHALL DETERMINE PROPER MARGIN STYLE TO MATCH CEILING CONSTRUCTION.2. ALL RUN OUT DUCTWORK TO DIFFUSERS SHALL BE NECK SIZE UNLESS OTHERWISE NOTED.PSYCHMARINE LABDESCRIPTION:333EXISTING TO REMAINEXISTING TO BE REMOVEDEXISTING DUCT TO REMAIN9. ANY CHANGES THAT ARE REQUIRED TO ELIMINATE CONFLICTSAND RESULT FROM A FAILURE TO COORDINATE SHALL BE MADEBY THE CONTRACTOR WITHOUT ADDITIONAL COST OREXPENSE TO THE OWNER.EXISTING DUCT TO BE REMOVEDNEW DUCT16x814x7EXHAUST/RELIEF AIR DUCT 4x7NCNEW CONNECTION14. PROVIDE ACCESS DOORS AT ALL DUCT MOUNTED EQUIPMENT.KEYNOTESBN22. FURNISH AND INSTALL NEW ROOF MOUNTED EXHAUST FAN.CONTRACTOR SHALL PROVIDE CURB ADAPTOR TO EXISTINGROOF CURB TO MATCH THROAT DIMENSIONS OF NEW FAN.VERIFY EXACT SIZE AND OFFSET REQUIREMENTS IN FIELD.COORDINATE SIZES WITH FAN MANUFACTURER.THIRD FLOOR PLAN - VENTILATION DEMOLITION1/4" 1'-0"SCHEDULE GENERAL NOTES:ORT H3456A. DISCONNECT AND CONTROLLER STARTER FURNISHED ANDINSTALLED BY:MFR MANUFACTURERATC AUTOMATIC TEMPERATURE CONTROL CONTRACTORB. DISCONNECT TYPE:F FUSEDNF NON-FUSEDC. CONTROLLER STARTER TYPE:FV FULL TIONISSUED FOR BIDISSUED FOR ADDENDUM #1VENTILATION DEMOLITION NOTES:1.REFER TO 3/V500 FORDIFFUSERCONNECTION DETAIL.(TYP.)CD-16/100CD-16/160CD-18/225THE DRAWINGS ARE INTENDED TO INDICATE THE SCOPE OFDEMOLITION WORK REQUIRED AND DO NOT INDICATE EVERYDUCT, OR PIECE OF EQUIPMENT THAT MUST BE REMOVED.ACCESSIBILITY OF EQUIPMENT AND SYSTEMS IS NOT SHOWNNOR SHOULD IT BE INFERRED. THE CONTRACTOR SHALLVISIT THE SITE PRIOR TO SUBMITTING A BID AND VERIFYEXISTING CONDITIONS.2. CONTRACTOR IS RESPONSIBLE FOR ALL COST ASSOCIATEDWITH CEILING SYSTEM DISASSEMBLY AND REASSEMBLY TOACCOMMODATE THIS WORK. CONTRACTOR TO SALVAGE,STORE, AND REINSTALL ALL CEILING MOUNTED DEVICES.3. CONTRACTOR IS RESPONSIBLE FOR PATCHING ALLPENETRATIONS CREATED BY REMOVAL OF EQUIPMENT,DUCTWORK, ETC. TO MATCH EXISTING. REPAIR ADJACENTCONSTRUCTION AND FINISHES DAMAGED DURINGDEMOLITION AND EXTENSION WORK. PATCH TO MATCHORIGINAL CONSTRUCTION. VERIFY ALTERNATIVE OR SPECIALREPAIR METHODS WITH ARCHITECT/ENGINEER BEFOREPROCEEDING WITH DEMOLITION.4. CONTRACTOR IS RESPONSIBLE FOR ALL MODIFICATIONS TOTHE EXISTING DUCTWORK NECESSARY TO PERMIT THEINSTALLATION OF NEW WORK.5. PROVIDE TEMPORARY CONNECTIONS TO MAINTAIN EXISTINGSYSTEMS IN SERVICE DURING CONSTRUCTION.6. EXTEND EXISTING INSTALLATIONS USING MATERIAL ANDMETHODS COMPATIBLE WITH EXISTING MECHANICALINSTALLATIONS, OR AS SPECIFIED FOR INTENDED SERVICE.7. REMOVE, RELOCATE, AND EXTEND EXISTING INSTALLATIONSTO ACCOMMODATE NEW CONSTRUCTION.8. REMOVE ALL ASSOCIATED CLAMPS, HANGERS, SUPPORTS,ETC., AND DUCT REMOVAL.9. DISCONNECT AND REMOVE MECHANICAL DEVICES ANDEQUIPMENT SERVING EQUIPMENT THAT HAS BEEN REMOVED.10. MAINTAIN ACCESS TO EXISTING MECHANICAL INSTALLATIONSWHICH REMAIN ACTIVE. MODIFY INSTALLATION OR PROVIDEACCESS PANEL AS APPROPRIATE.ANIMAL HOUSING 1335 AREFER TO 4/V500 FORDUCT REINFORCEMENTDETAIL.(TYP.)CD-112/390PSYCH MARINE DIAGONISTIC LABPSYCH MARINE HOUSING327333EG-122x22/125EG-122x22/450PROCEDURE LABEG-122x22/225335ANIMAL HOUSING 233

install new mechanical work. protect existing fixtures, finishes, equipment, furnishing during removal. re-install existing ceiling tiles. patch, clean and repair any damage to the existing space. see mechanical drawings. 0246 remove existing wall mounted fixtures, existing wiremold and existing outlets, typi

Related Documents:

about demolition work of old MARA building on Lot 1767, Lot 1218 and PT4, section 46, Kuala Lumpur, Jalan Tuanku Abdul Raliman had been conducted to be a guideline . 2.2 Techniques for Structure Demolition 6 2.21 Progressive Demolition 6 vii . vi" 2.2.2 Mechanism of Control Demolition 6 2.2.3 Deconstruction or Top Down 7 2.3 Demolition Methods 7

Richmond upon Thames College - Phase 1b Demolition Method Statement Phase 1b Overview Phase 1b demolition will require an estimated 14 weeks to complete. The below diagram shows the proposed programming of the demolition. Blue arrows show the direction of demolition. It is likely that the Music, Science and Z blocks

Structure/Building Open Air . Demolition 1.0 Executive Summary 2.0 Introduction This Technical Support Document (TSD) provides the basis for the Open Air demolition . Ensure open air demolition activities can be conducted using conventional demolition techniques with minimal radiological restrictions or controls (e.g., without area, equipment or

1.1 What is demolition work? Any work that is connected with the demolition of a structure is classified as 'construction work' under the WHS Regulations. When carrying out demolition work, the requirements relating to construction work must be complied with. Demolition work means to demolish or dismantle a structure or part of a structure that

ARMSTRONG Armstrong Ceiling Tile OPTRA - Armstrong Ceiling Tiles Beaty Sky -Armstrong Ceiling Tiles Dune Square Lay-In and Tegular - Armstrong Ceiling Tiles P r o d u c t s & S e r v i c e s. AEROLITE . WOODWORKS Grille Wooden False Ceiling Wood Wool Acoustic Panel P r o d u c t s & S e r v i c e s. TEE GRID SYSTEM

7. Place ceiling panel #8 into position and lock it to ceiling panel #7 first, then to the wall panels, leaving the wall-to-ceiling panel camlocks nearest the exposed ceiling panel seam on either side of ceiling panel #8 unlocked. Lock the two wall-to-ceiling panel camlocks left unlocked in step 4 to panel #7.

Ceiling Cassette Ceiling Convertible Fan Coil Unit Product Catalogue Ducted . Ceiling Convertible Type Ceiling Concealed Type Ducted Blower Type 20 24 Remark: All unit photos in this catalog are solely for illustration purpose, actual outlook may differ slightly. . The unit

4 Installing a Projector with the Ceiling Bracke t INSTALLING A PROJECTOR WITH THE CEILING BRACKET Overview Diagram of completed installation Ceiling Mount Device Installation Procedure Insert the U-PLATE into the CEILING ADAPTER, and tighten two M4 screws (from the bottom) into the screw holes. Then attach the top part to the ceiling.