FEATURES - Hubbellcdn

2y ago
12 Views
2 Downloads
1.28 MB
6 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Brady Himes
Transcription

KM4DATE:LOCATION:TYPE:PROJECT:CATALOG #:KICK ARCHITECTURAL AREA LIGHTINGFEATURES DELIVERED LUMENS Integral Motion Sensor Staggered twin mounting ANSI C136.31-2010 4G Rated IES Type II, III and IV distributions 3000K , 4000K, 5000K CCT Integral thermal protection3000K and warmer CCTs onlyRELATED PRODUCTS K5 KM5 KB6SPECIFICATIONSCONSTRUCTION Housing shroud is made of fabricated 5052H32 aluminum alloy with a rear mountinginterface that is made of fabricated 304stainless steel Housing mounting interface is a stampedsilicone gasket Luminaire housing is free of any visible heatfins, hardware or fasteners Bracketry and hardware is made of stainlesssteel B ase is made of cast aluminum #356 alloyand heat treated to a T-6 condition Shaft is extruded aluminum 6061 alloy andheat treated to a T-6 condition Anchor bolts are hot dip galvanizedsteel. Eight galvanized hex nuts and flatwashers,and a bolt circle template areprovided. Anchor bolt for poles are 3/4” x24” x 3” Luminaire finish consist of a five stagepretreatment regimen with a polymer primersealer, oven dry off, and top coated with athermoset super TGIC polyester powdercoat finish Luminaire finish meets the AAMA 605.2performance specification which includespassing a 3000 hour salt spray test forcorrosion resistanceLED/OPTICS LEDs are mounted to a metal printed circuitboard assembly (MCPCB) with a uniformconformal coating over the panel surface andelectrical features Optical lenses is made of clear injectionmolded PMMA acrylic Each MCPCB and optic are sealed to anextruded 6063-T6 aluminum alloy heatspreader and sealed with a continuousone piece injection molded silicone rubbergasket. IP66Page 1/6 Rev. 10/06/21KM4LED/OPTICS (CONTINUED) Patent Pending design of optical array isindependently shielding each LED optic acrossthe length of the apertureELECTRICAL Drivers are in direct contact with the aluminumhousing across the entire surface area of thewidest face for maximum thermal transfer Optical surfaces are painted white unless theoptional fixture finish (FO) or matte black finish(MO) is selected Luminaires have integral surge protection thatis U.L. recognized and have a surge currentrating of 10,000 Amps using the industrystandard 8/20uSec wave and surge rating of372J. Surge protection device is wired in series Optional matte black finish optics (MO) arerequired to meet UO classification with zeropercent uplight Drivers are U.L recognized Optional fixture finish optical surfaces (FO) donot exceed BUG ratings of the standard whitefinish and will be greater than or equal to thedelivered lumens of the optional matte blackoptical surface finish (MO) Drivers are not compatible with currentsourcing dimmers, consult factory for currentlist of known compatible dimming systemsapproved dimmers include Lutron Diva AVTV,Lutron Nova NFTV and NTFTVINSTALLATION Integral pole mount luminaires requireassembly of fixture(s) to the pole, mountinghardware, anchor bolts and anchor bolttemplate is included. See page 6 for additionalconsiderations specific to the integral pole Luminaire are capable of operating at 100%brightness in a 40 C environment. Bothdriver and optical array have integral thermalprotection that will dim the luminaire upondetection of temperatures in excess of 85 C Tenon mount luminaires require assemblyof fixture(s) to the tenon adapter, mountinghardware is included. Tenon adapter securesto the tenon with eight 5/16-18 stainless steelset screws Side mount luminaires are supplied withhardware compatible with AAL mountings. Twin mounted staggered height fixtures areconfigured separately Luminaires not configured with a control systemor ANSI C136 receptacle option are providedwith 0-10 purple and gray dimming leadsStandard Input Black ( )White (-)Green (GND)Gray Dimming Lead (-)FixtureHousing Service access to the optical array and driverassembly is via a tool-less internal latch andhave an audible click. Optical array has to hang freely in an openservice position for inspection of internal wireconnections. Once in service position, theoptical array is able to be removed for serviceby lifting the assembly up off the rear hinge anddisconnecting the wiring plugs.Purple Dimming Lead ( )1 mA Maxcontinued on page 3KEY DATALUMEN RANGE1,9090–3,576WATTAGE RANGE24–33EFFICACY RANGE (LPW)77–115WEIGHT8.95 lbs 4.05 kgEPA0.56 Driver assembly is mounted to a prewiredinternal tray with quick disconnects for removal 2021 Architectural Area Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.17760 Rowland St, Rowland Heights, CA 91748 / Tel 626.968.5666 / Website www.aal.net DIMENSIONAL DRAWINGSMini Small

KM4DATE:LOCATION:TYPE:PROJECT:CATALOG #:ARCHITECTURAL AREA/SITEORDERING GUIDEExample: LOG #Model (4" wide luminaire)Optics (Distribution) Optics FinishLight Engine 1KM41Single FixtureT2IES Type IIWO Standard White Finish20303000K CCT, CRI 70, 24 Watts MCPCRControlMulti-Channel 7-Pin Photocell ReceptacleKM42Two Fixtures 180 ApartT3IES Type IIIFOOptics in Fixture Finish20404000K CCT, CRI 70, 24 Watts SCPMotion Sensor Photocell 2KM43Three Fixtures 90 ApartT4IES Type IVMOOptics in Matte Black Finish20505000K CCT, CRI 70, 24 Watts SWPMKM44Four Fixtures 90 Apart30303000K CCT, CRI 70, 33 WattsSiteSync Pre-commissioned MotionSensor 3304024000K CCT, CRI 70, 33 Watts SCPREMOTE Handheld Commissioning Tool30505000K CCT, CRI 70, 33 WattsFuse (may choose one)VoltageMountingMounting OptionsFixture FinishSF120, 277, 347 Volt Input120–277V 120–277VIntegral PoleTwin mount at staggered heightsStandard ColorDF208, 240, 480 Volt Input347347VBlack Gloss Smooth480VMounting holes for a fixture at 180 ,KM41- PS4 only, may choose oneBLS480Square Straight Aluminum, 10.5"0 Bolt CirclePS410-125 10' Luminaire HeightTS88' from bottomBLTBlack Matte TexturedPS412-125 12' Luminaire HeightTS1010' from bottomDBSDark Bronze Gloss SmoothPS414-125 14' Luminaire HeightTS1212' from bottomDBTDark Bronze Matte TexturedPS416-125 16' Luminaire HeightTS1414' from bottomGTTGraphite Matte TexturePS418-125 18' Luminaire HeightTS1616' from bottomLGSLight Grey Gloss SmoothPS420-125 20' Luminaire Height TS1818' from bottomLGTLight Grey Matte TexturedPSSPlatinum Silver Gloss SmoothVGTVerde Green Matte TexturedTenon MountBase OptionsTA23Slips over a 2 3/8"/ 60mm 0 x 4" /102mm tall tenonSBCGFIMounts to the sideof a square pole,KM41 onlyGFCI receptacle, 24" from topof poleRBCDuplex receptacle box withclear cover, wiring device(s)not includedPole Accessories(may choose one)Side MountSMKWall MountWMKStandard Base CoverWHS White Gloss SmoothWHT White Matte TexturedCCCustom Color 4KM41 onlyNotes:1595nm monochromatic amber and or custom lumen package available by request2Handheld commissioning tool is required to separately configure or adjust any number of SCP sensors3Specify group and zone at time of order. See www.hubbelllighting.com/sitesync for more details. Orderat least one SiteSync interface accessory SWUSB or SWTAB. Each option contains SiteSync License,GUI, and Bridge NodeConsult factory for custom color, marine and corrosive finish4Page 2/6 Rev. 10/06/21KM4 2021 Architectural Area Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.17760 Rowland St, Rowland Heights, CA 91748 / Tel 626.968.5666 / Website www.aal.net

KM4DATE:LOCATION:TYPE:PROJECT:CATALOG #:ARCHITECTURAL AREA/SITESPECIFICATIONS 0MAXIMUM ALLOWABLE EPA (MPH)100110120130140150KM4X-PS410-12510’ 7.5” / 3.24m10’4” SQ x .125”28 lbs15.413.510.48.16.45.04.03.1KM4X-PS412-12512’ 7.5” / 3.85m12’4” SQ x .125”4532 lbs11.810.27.65.74.33.22.31.6KM4X-PS414-12514’ 7.5” / 4.46m14’4” SQ x .125”37 lbs9.17.75.53.92.61.70.95KM4X-PS416-12516’ 7.5” / 5.07m16’4” SQ x .125”42 lbs6.95.73.82.31.30.46--KM4X-PS418-12518’ 7.5” / 5.68m18’4” SQ x .125”48 lbs4.93.92.20.950.01---KM4X-PS420-12520’ 7.5” / 6.29m20’4” SQ x .125”53 lbs3.22.20.75-----* - Consult factory for thicker shaft profiles and or custom heights not shown above.CONTROLS Wireless enabled fixtures shall supportbi-directional radio frequency (RF)communications utilizing IEEE 802.15.4operating in the 2.4GHZ ISM band. Up to 1000’ wireless range may be reduced byphysical obstructions between lighting fixtures. Motion Sensor shall use passive infrared (PIR)sensing technology that reacts to changes ininfrared energy (moving body heat) within thecoverage area. Careful consideration mustbe given to obstructions that may block thesensor’s line of sight. Factory default settings for SCP option shall be: High mode: 10V Low mode: 1V Ramp-up rate: disabled Fade-down rate: disabled Photocell: Off Sensitivity: Full Time Delay: Fade to low: 5 minutes Time Delay: Fade to off: 1 hourCERTIFICATIONS Luminaire is listed with UL for outdoor, wetlocation use, UL1598, UL 8750 and CanadianCSA Std. C22.2 no.250 ANSI C136.31-2010 4G Vibration tested andcompliant IEC 66262 Mechanical Impact Code IK10 IDA approved, 3000K and warmerCCTs only This product qualifies as a “designated countryconstruction material” per FAR 52.225-11 BuyAmerican-Construction Materials under TradeAgreements effective 6/06/2020. See BuyAmerican SolutionsWARRANTY See HLI Standard Warranty foradditional informationPage 3/6 Rev. 10/06/21KM4 2021 Architectural Area Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.17760 Rowland St, Rowland Heights, CA 91748 / Tel 626.968.5666 / Website www.aal.net0.33

KM4DATE:LOCATION:TYPE:PROJECT:CATALOG #:ARCHITECTURAL AREA/SITEDELIVERED lackPage 4/6 Rev. 10/06/21KM4DistributionType 2Type 3Type 4Type 2Type 3Type 4Type 2Type 3Type 4Type 2Type 3Type 4Type 2Type 3Type 4Type 2Type 3Type 2535256328863000K 70CRI4000K 70CRIBug RatingBug K 5103107838394838394 2021 Architectural Area Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.17760 Rowland St, Rowland Heights, CA 91748 / Tel 626.968.5666 / Website 95350034233576267627063047267627063047Bug 06104109818293818293

KM4DATE:LOCATION:TYPE:PROJECT:CATALOG #:21.84.0ARCHITECTURAL AREA/SITE5.02.5DIMENSIONS9.59.64.6SIDE MOUNTED LUMINAIRE (S)MODELOVERALL HEIGHTOVERALL LENGTHOVERALL WIDTHWEIGHTEPAKM4X- -SMK9.6” / 244mm21.8” / 554mm4” / 102mm8.95 lbs.0.56(optional) .64.6"4.610.4KM41- -WMK10.4” / 264mm22.2” / 564mm5.8” / 147mm10 lbs.10.4(optional) SCP1.56.4WALL MOUNTED LUMINAIRE (S)MODELOVERALL HEIGHTOVERALL LENGTHOVERALL WIDTHWEIGHT22.2KM4(optional) 6.4KM4(optional) SCP5.8"KM4 WALL MOUNTINTEGRAL POLE LUMINAIREKM4 WALL MOUNTMODELKM41- -PS4XX-125OVERALL LENGTH25.8" / 655MMOVERALL WIDTH10" / 254MMWEIGHT8.95 LBS.EPA*0.56KM42- -PS4XX-125POLE KM4POLE KM410" / 254MM47.5" / 1206MM8.95 LBS.1.12POLE KM4KM43- -PS4XX-125POLE KM425.8" / 655MM47.5" / 1206MM8.95 LBS.1.44KM44- -PS4XX-12547.5" / 1206MM47.5" / 1206MM8.95 LBS.1.44TENON MOUNT LUMINAIRESlips over a 2 3/8”/60mm diameter by 4”/102mm tall tenonMODELOVERALL HEIGHTOVERALL LENGTHOVERALL WIDTHWEIGHTEPA*Page 5/6 Rev. 10/06/21KM4KM41- -TA2313.5” / 343MM25.8” / 655MM4” / 102MM8.95 LBS.0.87KM42- -TA2313.5” / 343MM10” / 254MM47.5” / 1206MM8.95 LBS.1.44 TENON KM4TENONTENONKM4 KM4KM43- -TA2313.5” / 343MM25.8” / 655MM47.5” / 1206MM8.95 LBS.TENON1.62 KM4 2021 Architectural Area Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.17760 Rowland St, Rowland Heights, CA 91748 / Tel 626.968.5666 / Website www.aal.netKM44- -TA2313.5” / 343MM47.5” / 1206MM47.5” / 1206MM8.95 LBS.1.62

KM4DATE:LOCATION:TYPE:PROJECT:CATALOG #:ARCHITECTURAL AREA/SITETM-30 DATATEST SOURCEORDERING CODERfRgCCT(K)80% DuvCIE RaXX30XX4069697199999838525020Relative Power100%31220.001XX500.0004 e PowerVALUEReference IlluminantSPECTRAL POWER DISTRIBUTION COMPARISONReletive PowerCOLOR VECTOR GRAPHIC80%60%40%20%0%40%380Test Source430480530580630680730780Wavelength (nm)Wavelength (nm)20%ELECTRICAL CHARACTERISTICS0%LEDSYSTEMORDERING 20-27730XX70033120-277430HZ50/60INRUSH CURRENTDIMMING530580630680730780PEAKMIN. MAXT@50%MIN.Wavelength (nm) (A)DIMMING SOURCE/AMPS AC POWER THD(ΜS)POWERSINKFACTOR (%)RANGE CURRENT(V)120 277 120 277120 277(MA)INPUT4800.20.10.30.1 0.920651000-101TM-21 LIFETIME CALCULATION (500MA)REPORTEDL70 60Khrs.House Side Street SideSENSOR DETECTION RANGE12'20'25'30'SENSOR MOUNTING HEIGHT14' 16' 18' 20' 25' 30'35'40'45'35'40'50' 62.5' 75' 87.5' 100'RATIO58º (16%)1:2.5FixtureFIXTUREPage 6/6 Rev. 10/06/21KM4 2021 Architectural Area Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.17760 Rowland St, Rowland Heights, CA 91748 / Tel 626.968.5666 / Website www.aal.netSCPSCP10'SSCPHOUSE SIDECOVERAGEDIAMETER8'PolePOLE2540PROJECTED LUMENMAINTENANCE (KHRS)2550 60 (TM-21) 75 10098% 95%94%93% 90%98% 96%95%93% 90%STREET SIDEAMBIENTENVIRONMENT C

17760 Rowland St, Rowland Heights, CA 91748 / Tel 626.968.5666 / Website www.aal.net . Model (4" wide luminaire) Optics (Distribution) Optics Finish Light Engine 1 Control KM41 Single fixture KM42 Two fixtures 180 apart KM43 Three fixtures 90 apart KM44 Four fixtures 90 apart

Related Documents:

Magnetic Line Starters – 3 Pole, 3 Phase, Single Speed Non Reversing 600 VAC Max, 60Hz Square D or Cutler-Hammer motor starters available as standard. For Cutler-Hammer only, heaters not included. See page S9 to order. Line Starter Combination Starter FEATURES-SPECIFICATIONS B7 MAGNETIC LINE STARTERS NEMA

Magnetic Line Starters – 3 Pole, 3 Phase, Single Speed Non Reversing 600 VAC Max, 60Hz Square D or Cutler-Hammer motor starters available as standard. For Cutler-Hammer only, heaters not included. See page S9 to order. Line Starter Combination Starter FEATURES-SPECIFICATIONS B7 MAGNETIC LINE STARTERS NEMA

URBANSERIES-SPEC FEATURES Decorative transitional style lighting fixture series is suitable for walkway lighting and wall mounting Two unique shade and style options LED turtle-friendly option available Integral Surge and Thermal Protection URBAN SERIES URBAN LUMINAIRE DATE: LOCATION: TYPE: PROJECT: CONSTRUCTION

With our up-to-date Time Domain Reflectometry (TDR) method and high voltage capacitive discharge units, precise pinpointing of cable faults is easy. Each product offers easy operating features which minimize user training and reduce excessive damage to the cable under test. See our full range of cable fault locating tools and equipment below.

11 Standard Tools: These four design tools on the Tools Menu will be available in Construction, Light and Calculation mode. Help Lines and Labeling: Draw Reference Lines: These lines can be used to place objects or luminaires along the lines or simply to create a new or missing line inside the DWG file.

Understand basic wiring principles and techniques. If you are replacing an old receptacle, pull it Can interpret wiring diagrams. Have circuit wiring experience. Are prepared to take a few minutes to test your work, making sure that you have wired the GFCI receptacle correctly. 5. Turn the power OFF

Wiley and BURNDY. In 2011, BURNDY was thrilled to combine our history of engineering expertise, superior customer service and long-term reliability with the Wiley product line. Industry-leading companies specify the Wiley family of products more often than any other brand in projects. Wiley is most widely recognized for the invention of the WEEB

NORTH & WEST SUTHERLAND LOCAL HEALTH PARTNERSHIP Minutes of the meeting held on Thursday 7th December 2006 at 12:00 Noon in the Rhiconich Hotel, Rhiconich. PRESENT: Dr Andreas Herfurt Lead Clinician Dr Moray Fraser CHP Medical Director Dr Alan Belbin GP Durness Dr Anne Berrie GP Locum Dr Cameron Stark Public Health Consultant Mrs Sheena Craig CHP General Manager Mrs Georgia Haire CHP Assistant .