Product Data Sheet Rosemount 3051S April 2007

2y ago
10 Views
3 Downloads
759.26 KB
7 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Francisco Tran
Transcription

Product Data Sheet00813-0100-4801, Rev JAApril 2007Rosemount 3051SRosemount 3051S FOUNDATION fieldbus with Mass Flow Block (H01) Configuration Data SheetComplete this form to define a Custom Flow Configuration for the Rosemount 3051S Foundation fieldbus with Mass Flow Block (H01).Unless specified, the 3051S will ship with the default values identified by the symbol.For technical assistance in filling out this CDS, contact your local Emerson Process Management representative.Note: Any missing information will be processed with the indicated default values.Customer InformationCustomer: Contact Name:Phone No: Fax No./Email:P.O./Reference No.: P.O. Line Item:Quote No. Model No.:Customer Signoff:TaggingTag No.:Software Tag:Transmitter Information (Optional)Descriptor (32 characters maximum) (32 characters)Flow Configuration (required)Select units for each Process Variable, then enter sensor Lower Trim Value (LTV) and sensor Upper Trim Value (UTV).Note: LTV and UTV must be within the range limits.Differential Pressure (DP)DP Units inH2O-68 F inH2O-4 C ftH2O-68 F mmH2O-68 F mPa mmH2O-4 C psi bar mbar inHg 0 C g/SqCm Kg/SqCm Pa kPa mmHg 0 C torr AtmLTV (0 )Trim ValuesUTV (URL in H2O-68 F )Static Pressure (SP)Static Pressure Units inH2O-68 F inH2O-4 C ftH2O-68 F mmH2O-68 F mPa mmH2O-4 C psi bar mbar inHg 0 C g/SqCm Kg/SqCm Pa kPa mmHg 0 C torr AtmTrim Values(1)LTV (0 )UTV (URL psi )Process Temperature (PT)PT Units Trim ValuesLTV (-300 ) F CUTV (1500 F )3051S FOUNDATION fieldbus Configuration Data Sheet - Page 1 of 752

Product Data Sheet00813-0100-4801, Rev JAApril 2007Rosemount 3051SFlow Configuration (cont.)Flow RateFlow Units StdCuft/sStdCum/hlbs./hourgrams/hourNmlCuM/hour hlbs/secgrams/seckg/minmton/hour StdCuft/dlbs/mingrams/minkg/hourmton/daySpecial (other units available on request)Flow RateLow PV (minimum)Fluid Type (Select One) Gas(0.00Liquid)High PV (Full Scale): (100 lbs/sec) SteamFluid Information (Complete one section only) Steam (ASME Saturated and/or Superheated) Natural Gas NOTE: If you selected Natural Gas, complete Compressibility Factor Information on page 54 Gas or Liquid from AlChE database: Select ONE fluid name below: Acetic Acid Cyclopropane Isopropanol n-Heptane Acetone Divinyl Ether Methane n-Hexane Acetonitrile Ethane Methanol n-Octane Acetylene Ethanol Methyl Acrylate n-Pentane Acrylonitrile Ethylamine Methyl Ethyl Keton Oxygen Air Ethylbenzene Methyl Vinyl Ether Pentafluorothan Allyl Alcohol Ethylene m-Chloronitrobenzen Phenol Ammonia Ethylene Glycol m-Dichlorobenzene Propane Argon Ethylene Oxide Neon Propadiene Benzene Fluorene Meopentane Pyrene Benzaldehyde Furan Nitric Acid Propylene Benzyl Alcohol Helium-4 Nitric Oxide Styrene Biphenyl Hydrazine Nitrobenzene Sulfur Dioxide Carbon Dioxide Hydrogen Nitroethane Toluene Carbon Monoxide Hydrogen Chloroide Nitrogen Trichloroethylen Carbon Tetrachlorid Hydrogen Cyanide Nitromethane Vinyl Acetate Chlorine Hydrogen Peroxide Nitrous Oxide Vinyl Chloride Chlorotrifluoroethylen Hydrogen Sulfide n-Butane Vinyl Cyclohexan Chloroprene Isobutane n-Butanol Water Cycloheptane Isobutene n-Butyraldehyde 1-Butene Cyclehexane Isobutylbenzene n-Butyronitrile 1-Decene Cyclopentane Isopentane n-Decane 1-Decanal Cyclopentene Isoprene n-Dodecane 1-Decanol n-Heptadecane 1-Dodecene Custom Gas or Liquid butaneEnter custom fluid nameNOTE: If defining a custom fluid, complete the density and viscosity information on page 553051S FOUNDATION fieldbus Configuration Data Sheet - Page 2 of 753

Product Data Sheet00813-0100-4801, Rev JAApril 2007Rosemount 3051SRequired For Natural Gas OnlyCompressibility Factor InformationChoose desired characterization method, and only enter values for that method: Detail Characterization Method (AGA8 1992)MoleValid RangeCH4Methane mole percent%0-100 percentN2Nitrogen mole percent%0-100 percentCO2Carbon Dioxide mole percent%0-100 percentC2H6Ethane mole percent%0-100 percentC3H8Propane mole percent%0-12 percentH2OWater mole percent%0-Dew PointH2SHydrogen Sulfide mole percent%0-100 percentH2Hydrogen mole percent%0-100 percentCOCarbon Monoxide mole percent%0-3.0 percentO2Oxygen mole percent%0-21 percentC4H10i-Butane mole percent%0-6 percent(2)C4H10n-Butane mole percent%0-6 percent(2)C5H12i-Pentane mole percent%0-4 percent(3)C5H12n-Pentane mole percent%0-4 percent(3)C6H14n-Hexane mole percent%0-Dew PointC7H16n-Heptane mole percent%0-Dew PointC8H18n-Octane mole percent%0-Dew PointC9H20n-Nonane mole percent%0-Dew PointC10H22n-Decane mole percent%0-Dew PointHeHelium mole percent%0-3.0 percentArArgon mole percent%0-1.0 percent Gross Characterization Method, Option 1(AGA8 Gr-Hv-Co2)Valid RangeSpecific gravity at 14.73 psia and 60 FVolumetric Gross Heating Value at Base ConditionsBTU/SCF477-1150 BTU/SCF0.554-0.87Carbon Dioxide mole percent%0-30 percentHydrogen mole percent%0-10 percentCarbon Monoxide mole percent%0-3 percent Gross Characterization Method, Option 2(AGA8 Gr-CO2-N2)Valid RangeSpecific gravity at 14.73 psia and 60 FCarbon Dioxide mole percent%0-30 percentNitrogen mole percent%0-50 percentHydrogen mole percent%0-10 percentCarbon Monoxide mole percent%0-3 percent(2)The summation of i-Butane and n-Butane cannot exceed 6 percent.(3)The summation of i-Pentane and n-Pentane cannot exceed 4 percent.0.554-0.873051S FOUNDATION fieldbus Configuration Data Sheet - Page 3 of 754

Product Data Sheet00813-0100-4801, Rev JAApril 2007Rosemount 3051SRequired for Custom Gas OnlyGas Compressibility and Viscosity Information1. Fill in the following operating pressures and operating temperatures.Min and max values must match values entered under Process Operating Conditions.Operating PressuresOperating Temperatures(1) min(8) [1/3(max-min)] min(5) min11(2) [ /3(max-min)] min(6) [ /2(max-min)] min(3) [2/3(max-min)] min(7) max(9) [2/3(max-min)] min(4) max2. Transfer the values from the above section to the numbered lines below.3. Check one Density/Compressibility box, then enter the 12 values for each pressure/temperature range.4. Check one Viscosity box, then enter values for each temperature. (At least one viscosity value is required.)5. Enter values for molecular weight, isentropic exponent, and standard density (or standard compressibility). Density in Kg/CuM Viscosity in Centipoise Density in Lbs/CuFt Viscosity in Lbs/Ft Sec Viscosity in Pascal )(5)(5)(2)(5)(8)(3)(5)(9)(7)Molecular WeightIsentropic Exponent1.4 )(7)Standard density/compressibility (at standard reference conditions specified on page 57)NOTE: All customer gas configuration information must be completed. Order will be delayed if fields are left blank.3051S FOUNDATION fieldbus Configuration Data Sheet - Page 4 of 755

Product Data Sheet00813-0100-4801, Rev JAApril 2007Rosemount 3051SRequired for Custom Liquid OnlyLiquid Density and Viscosity InformationNOTE: Only fill out this page if you have selected a custom liquid.1. Fill in the following operating temperatures. (Min and max values must match values entered under Process Operating Conditions)Operating Temperatures(a) min(b) [1/3(max-min)] min(c) [2/3(max-min)] min(d) max2. Transfer the values from the above section to the lettered lines below.3. Check one Density box, then enter values for each temperature and the standard density.4. Check one Viscosity box, then enter values for each temperature. (At least one viscosity value is required.) Viscosity in Centipoise Density in Lbs/CuFt Temperature Viscosity in Lbs/Ft Sec Viscosity in Pascal Sec Standard density/compressibility (at standard reference conditions specified on page 57)NOTE: All customer gas configuration information must be completed. Order will be delayed if fields are left blank.Primary Element InformationSelect Differential Producer (Select One) 405P Compact Orifice Orifice, Corner Taps, ISO 405C Compact Conditioning Orifice 1595 Conditioning Orifice 1195 Integral Orifice Orifice, Flange Taps, AGA3 485 Annubar/ 3095 MFA Mass ProBar Small Bore Orifice, Flange Taps, ASME 485 Annubar/ 3095 MFA Mass ProBar, Constant K Venturi Nozzle, ISO Calibrated 485 Annubar/ 3095 MFA Mass ProBar Orifice, Flange Taps, ISO Annubar diamond II / Mass ProBar Orifice, 21/2D & 8D Taps Calibrated Annubar Diamond II / Mass ProBar Orifice, Corner Taps, ASME Annubar Diamond II (1999) Orifice, Flange Taps, ASME Nozzle, Long Radious Wall Taps, ASME Orifice d & D/2 Taps, ASME Nozzle, Long Radious Wall Taps, ISO Venturi, Rough Cast/Fabricated Inset, ASME Nozzle, ISA 1932, ISO Venturi, Rough Cast Inlet, ISO Orifice, D & D/2 Taps, ISO Venturi, Machined Inlet, ASME Venturi, Welded Inlet, ISO3051S FOUNDATION fieldbus Configuration Data Sheet - Page 5 of 756

Product Data Sheet00813-0100-4801, Rev JAApril 2007Rosemount 3051SPrimary Element Information (cont.)Selecting Area Averaging Meter, V-Cone , or calibrated primary element requires a constant value for discharge coefficient: . Area Averaging Meter V-ConePrimary Element Minimum Diameter (d)atCalibrated Venturi Calibrated output in. mm F C in. at 68 F orSensor Series No.(Enter series designation)Differential Producer Material (Select One) Carbon Steel SST 304 Hastelloy C Monel SST316Pipe Tube InformationPipe Tube Diameter (Pipe ID) (D) in.at FPipe Tube Material (Select One) Carbon Steel SST 304 SST 316 Hastelloy C Monelmm C in. at 68 F Process Operating ConditionsOperating Differential Pressure RangetoDifferential Pressure Units (DP) inH2O-68 F inH2O-4 C ftH2O-68 F mmH2O-68 F mPa mmH2O-4 C psi bar mbar inHg 0 C g/SqCm Kg/SqCm Pa kPa mmHg 0 C torr AtmOperating Static Pressure RangetoStatic Pressure Units (SP) inH2O-68 F inH2O-4 C ftH2O-68 F mmH2O-68 F mPa mmH2O-4 C psi bar mbar inHg 0 C g/SqCm Kg/SqCm Pa kPa mmHg 0 C torr AtmOperating Temperature Rangeto F CFixed Process Temperature Value:NOTE: For steam applications, temperatures must be equal to or greater than the saturation temperature at the given pressures. AllProcess operating conditions information must be completed.Atmospheric PressureAtmospheric Pressure psia kPa (absolute) Bar14.696 psia Standard Reference ConditionsNOTE: The information is required if any of the following flow units were selected:StdCuft/s, StdCuft/min, StdCuft/h, StdCuft/d, StdCum/h, StdCum/dStandard Reference Conditions:Standard Pressure psia Bar14.696 psia (gas/steam only) kPa (absolute)Standard Temperature F C60 F (For steam, 212 F )3051S FOUNDATION fieldbus Configuration Data Sheet - Page 6 of 757

Product Data SheetRosemount 3051SFor RMD Internal Use OnlyHouse Order No.:Line Item No.:Transmitter Serial No.:RCC Tech.:3051S FOUNDATION fieldbus Configuration Data Sheet - Page 7 of 75800813-0100-4801, Rev JAApril 2007

Product Data Sheet 00813-0100-4801, Rev JA Rosemount 3051S April 2007 52 Rosemount 3051S FOUNDATION fieldbus with Mass Flow Block (H01) Configuration Data Sheet Complete this form

Related Documents:

Rosemount 3051S Pressure Transmitter High accuracy pressure measurement for tank gauging systems Note For the general 3051S Product Data Sheet, see document number 00813-0100-4801. 2 Rosemount 3051S October 2014 www.rosemount-tg.com Rosemount 3051S pressure transmitter in tank gauging

Rosemount 3051S Coplanar DP and Gage 0 82 274 40 Rosemount 3051S Coplanar Absolute, In-line Gage and Absolute 0 80 260 37 Rosemount 3051S Flow Meter based on 1195, 405, or 485 primaries 0 90 274 51 Rosemount 3051S Level Transmitter (w/o additional seal) 0 82 274 74. Safety Manual 00809-0700-4801 Installation and commissioning March 2021. 7 \(1 .

3 March 2015 Rosemount DP Level www.rosemount.com Rosemount 3051S Electronic Remote Sensor Systems The Rosemount 3051S ERS System is a new digital DP Level architecture that links two 3051S pressure sensors together electronically. Differential pressure, level, and volume is calculate

Rosemount 3051S Series October 2008 4 Rosemount 3051S Scalable Products Rosemount 3051S MultiVariable Transmitter See ordering information on page 39. † Performance up to 0.65% flow accuracy over 14:1 flow turndown † Mass, energy, actual volumetric, and totalized flow outputs † Differential pressure, gage or absolute pressure, and

Rosemount 300ERS Housing Kit Upgrade and convert an existing Rosemount 3051S Transmitter into a Rosemount 3051S ERS Transmitter. Easily order replacement housings and electronics for an existing Rosemount ERS System. Process leaks could result in death or serious injury. Install and tighten all four flange bolts before applying pressure.

Rosemount 3051S/3051/2051/3095 Rosemount 1151 D C D Rosemount 3051S/3051/2051/3095 Rosemount 1151 Februari 2019. 8 Snelstartgids 2.6 Montagerichting inline-druktransmitter De drukpoort aan de lage kant (ref. atmosferische druk) op de inline-verschildruktransmitter bevindt zich in de hals van de transmitter, achter

Rosemount 3051S March 2008 4 Rosemount 3051S Selection Guide Rosemount 3051S_C Coplanar Differential, Gage, and Absolute See ordering information on page 31. † Performance up to 0.025% accuracy and 200:1 rangedown † Available 10-year stability and 12-year limited warranty † Coplanar platform enables integrated manifold, primary element and

engineering materials, tools, equipments, manufacturing processes, basic concepts of electro-mechanical controls of machine tools, production criteria’s, characteristics and uses of various testing instruments and measuring or inspecting devices for checking components or products manufactured in various manufacturing shops in an industrial environment. It also describes and demonstrates the .