User GuidePelican and its Logo are Trademarks of Pelican Wireless SystemsPelican Support: 1-888-512-0490

Table of ContentsCHAPTER 1:Getting Started41.1 Setting Up a Pelican Site Manager1.2 Setting Up a Password1.3 Navigating Your New Pelican Site ManagerAdmin Screen1.4 Navigating an Existing Pelican Site ManagerHome ScreenGroup Screen4556667CHAPTER 2:Setup your Pelican Site Manager72.1 Setup Default Thermostat Configuration2.2 Default Thermostat ConfigurationSystem Operation (Heat Pump)System Operation (Conventional)Thermostat SettingsInput Power ConsumptionNotification SettingsSchedule Settings2.3 Add or Remove Administrators or UsersAdministrator OptionsUser OptionsDelete an Admin or User2.4 Site Configuration OptionsSite ConfigurationAdding Additional GatewaysLocationUsage CostsAutomated Email and/or Text Message ER 3:Pelican Thermostat (TS200, TS200H, TCM)163.1 Name and Configure a New Pelican ThermostatGeneral SettingsAccess an Existing Thermostat’s Setup PageTroubleshooting a Thermostat’s Relay Output Signals3.2 Controlling a Pelican ThermostatThermostat ControlSetting a Temperature3.3 Scheduling a Thermostat3.4 Activating the Vacation ScheduleOne Touch Vacation ButtonUsing the One Touch Vacation ButtonSetup and Use the Vacation Calender161616171718181921212121PELICAN USER GUIDETable of Contents·1

3.5 Setting up Vacation SchedulesSetting up a Default Vacation ScheduleAdd a Vacation Schedule to a ThermostatVacation Settings3.6 Reading a History Graph2222232424CHAPTER 4:Remote Wireless Sensor (RT1-AC, RT1-DC)254.1 Name and Configure a New Remote Wireless ThermostatGeneral SettingsAccess an Existing Remote Thermostat’s Setup Page4.2 Managing a Remote ThermostatNavigate to a Remote ThermostatSetting Weighted Temperature Percentages4.3 Reading a History Graph with Remote TemperaturesNavigate to a Thermostat’s History Graphs2526262626272727CHAPTER 5:Wired Temperature and Alarm Sensor (TA1)285.1 Name and Configure a New Temperature and Alarm SensorAccess a Thermostat Setup Page that is Connected with a TA1 SensorWired SensorTemperatureAlarmTemp Monitor5.2 Managing a Temperature Sensor Set to TemperatureNavigate to the Thermostat a Temperature Sensor is Connected tooSetting Weighted Temperature Percentages282829292929303030CHAPTER 6:Wireless Proximity Sensor (PRX1)316.1 Name and Configure a New Proximity SensorGeneral SettingsAccess an Existing Proximity Sensor’s Setup Page6.2 Managing a Proximity SensorNavigate to a Proximity SensorActivate and Deactivate a Proximity Sensor313131313132CHAPTER 7:Power Control Module (PM5-230)327.1 Name and Configure a New Power Control ModuleRelay SettingsAccess an Existing Power Relay Module’s Setup Page7.2 Managing a Power Control ModuleNavigate to a Power Relay Module’s Control PagePower Relay Module Control7.3 Scheduling a Power Control Module32323333333333PELICAN USER GUIDETable of Contents·2

33333535353536Navigate to a Power Relay Module’s Control PageSchedule a RelayAdd Multiple Schedules for a Single RelayEdit an Existing ScheduleTurn a Schedule On or OffAdd a Vacation ScheduleTurn ON a schedule one day and turn it OFF the next dayCHAPTER 8:Forgot Password378.1 Generate a New Temporary Password37CHAPTER 9:MySites389.1 What is MySites?9.2 Navigate to MySites9.3 Using your MySites383838PELICAN USER GUIDETable of Contents·3

1. Getting Started1.1 Setting Up a Pelican Site ManagerInstall your Pelican Gateway and write down the serial number found on its front - XXX-XXXX.Access a Web Browser on any Internet enabled device: PC, Tablet, or Smartphone.- Note: On a PC, Pelican works best on Mozilla Firefox, Google Chrome, Apple Safari, or MicrosoftInternet Explorer 9 or newer.In your Web Browser go to URL: www.PelicanWireless.comOnce on Pelican’s website you will see the menu bar:HOMEPRODUCTSLITERATURESUPPORTCASE STUDIESNEW SITE SETUPNEWSSelect NEW SITE SETUPInput the requested information into the Site Wizard:If you receive the error message: Invalid serial number or unreachable Gateway. Re-check that your PelicanGateway is installed correctly and is able to reach the Internet. If you continue to receive this error messagecontact Pelican Support.If able to reach the Gateway: Input the Site Name you want to use for accessing your Pelican Site Manager. Thebeginning of your Site Name is unique, while it will always end in .officeclimatecontrol.net.Administrator Email Address is considered the Super Administrator for the Pelican Site. This administrator iswho will be notified for Subscription payments.PELICAN USER GUIDEChapter 1·4

Site Type is dependent on the building you are installing Pelican’s Solution into.Site Post/Zip Code is used to set the clock and timezone for your Pelican Site Manager.By pressing SUBMIT you will generate an automated email to the Administrator’s email address. This email willprovide the Administrator with a temporary password. This can take up to 15 minutes. If after 15 minutes youdo not receive an email from notice@pelicanwireless.com, check your SPAM folder.1.2 Setting Up a PasswordOn a Web Browser type in the URL you created for your Pelican Site Manager: ‘name’.officeclimatecontrol.netEnter the Administrator Email Address you used when setting up your Pelican Site Manager.Enter the Temporary Password you received via email from Pelican.A new screen will appear requesting a permanent password. Enter in the password you want to permanentlyuse for accessing your Pelican Site Manager.Press SUBMIT and you will be directed to your new Pelican Site Manager.1.3 Navigating your New Pelican Site ManagerBefore you install any Pelican thermostats youwill only have a few options on your PelicanSite Manager:Usage Graphs - Graphs displaying the energyconsumption of your HVAC systems.System Time - Shows the Current time, Dusttime, and Dawn time for your location.Admin - Setup and Configuration options arefound here.PELICAN USER GUIDEChapter 1·5

ADMIN SCREENUser Management - Select to add a newadministrators or users to your Pelican SiteManager.Site Configuration - Where you can findspecific information about your Pelican SiteManager. It is also where you add additionalGateways and setup email or text messagealerts.Default Thermostat Config - For creating adefault configuration that will automaticallyupload into each Pelican thermostats as youinstall them.Default Schedule - For creating a defaultschedule that will automatically upload into aPelican thermostat when you turn ON itsschedule.Network Map - A graphical map showing howyour Pelican products are communicatingthrough-out the building they are installed in.1.4 Navigating an Existing Pelican Site ManagerAfter you have installed your Pelican thermostats and configured them, you will have more options on yourPelican Site Manager.HOME SCREENNotifications - These will appear when Pelicandetects a maintenance issue with one of yourHVAC units.Groups - On your Home Screen the Blue FanIcon indicates Groups of thermostats.Usage Graphs - Graphs displaying the energyconsumption of your HVAC systems.System Time - Shows the Current time, Dusttime, and Dawn time for your location.Admin - Setup and Configuration options arefound here.PELICAN USER GUIDEChapter 1·6

GROUP SCREENThermostat CurrentOperation:Cool On - Calling for AirConditioning.Heat On - Calling for Heat.Thermostat NamesFan On - Calling for Fan.Heat - Showing heatsetting.Cool - Showing coolsetting.System Off - Thermostat isset to OffThermostats Real-Time TemperatureBeing Detected2. Setup your Pelican Site Manager2.1 Setup Default Thermostat ConfigurationThe Default Thermostat Configuration allows you to setup a default configuration for your PelicanThermostats. As you install new Pelican Thermostats, and they connect with the gateway, they willautomatically upload the Default Thermostat Configuration that you have set.For sites that have multiple thermostats with similarities in configuration, by configuring the most commonsetting options, you can reduce your overall setup time. For any individual thermostats that require differentconfiguration options, you can change their configuration independently after you install them.NOTE: The Default Thermostat Configuration must be setup before installing any thermostats to workproperly. Changing the Default Thermostat Config does NOT change already installed thermostat’s settings.1. If you are not on your Home screen press Back or navigate to your Pelican Home screen.2. Select Admin at the bottom of your Home screen.3. Select Default Thermostat Config from your Adminscreen.4. Select the Configuration options that fit the thermostats you are installing.PELICAN USER GUIDEChapter 2·7

2.2 Default Thermostat ConfigurationSYSTEM OPERATION (HEAT PUMP)System Type - Set to Heat Pump.Reversing Valve - Set to Cooling ON to activatewhen calling for Cool (O) or Heating ON to activatewhen calling for Heat (B).Cycles Per Hour - Sets a target number of times ourthermostat will run each hour to maintain a specifictemperature.Anticipation Degrees - STOP calling for heat or coolthis many degrees before reaching the targettemperature. (In anticipation that the spacetemperature will still rise or fall after thethermostat stops calling for Heat or Cool).Calibration Degrees - For calibrating thetemperature being detected by the thermostat.Heat Stages - Sets how many Heat stages thethermostat will be controlling. NOTE: If you set to 0stages it will disable the Heat function of thethermostat.Aux Heat - There are three Aux Heat settings:Disabled - Do not have or do not wantto use Auxiliary Heat.Auxiliary - If the Heat Pump cannotachieve a temperature change of 5 perhour then the thermostat will turn ONthe Aux Heat (makes this decisionwithin 10 minutes of running the HeatPump).Emergency - If at anytime the HeatPump runs for an hour and thetemperature is not trending in thecorrect direction, the thermostat willturn ON the Aux Heat and send anotification that it has been turned ON.Cool Stages - Sets how many Cool stages thethermostat will be controlling. NOTE: If you set to 0stages it will disable the Cool function of thethermostat.Fan Stages - Sets how many Fan stages thethermostat will be controlling.Heat Needs Fan - Seting to YES means thethermostat will turn the fan ON when it calls forHeat.Fan Circulation Minutes - Is an optional input forhaving the thermostat turn ON the fan a certainamount of minutes every hour.PELICAN USER GUIDEChapter 2·8

SYSTEM OPERATION (CONVENTIONAL)System Type - Sets to Conventional.Cycles Per Hour - Set a target cycle rate or thenumber of times the thermostat should run, eachhour, to properly maintain a set temperature.Anticipation Degrees - STOP calling for heat orcool this many degrees before reaching the targettemperature. (In anticipation that the spacetemperature will still rise or fall after thethermostat stops calling for Heat or Cool).Calibration Degrees - Calibrate the temperaturebeing detected by the thermostat.Heat Stages - Set how many Heat stages thethermostat is controlling. NOTE: If you set thevariable to 0 it will fully disable Heat.Cool Stages - Set how many Cool stages thethermostat is controlling. NOTE: If you set to 0 itwill fully disable Cool.Fan Stages - Set how many Fan stages thethermostat is controlling.Heat Needs Fan - Seting to YES means thethermostat will turn the fan ON when it calls forHeat.Fan Circulation Minutes - Is an optional input tohave the thermostat turn ON the fan a certainamount of minutes every hour.THERMOSTAT SETTINGSTemp Display - Display temperature inFahrenheit or Celsius.Heat Range - Set a limitation on the settableHeat temperature range.Cool Range - Set a limitation on the settableCool temperature range.Allow Keypad Control - Set YES to be able tolock the thermostat’s keypad. NOTE: Thisoption does NOT Lock or Unlock thethermostat. Go to Page 18 - ThermostatControl - for directions on locking athermostat.PELICAN USER GUIDEChapter 2·9

INPUT POWER CONSUMPTIONPelican uses these power sizes to calculate theconsumption rate of running your HVAC units.Input the most accurate power sizes foraccuracy in calculation. The # of inputschanges based on the # of stages yourthermostat is set to control. Input in KW, TON,BTU, or WATT. If you choose TON it willcalculate consumption based on a 13 SEERrating.Heat 1 Size - The consumption rate of Stage 1HeatHeat 2 Size - The consumption rate of Stage 2HeatCool 1 Size - The consumption rate of Stage 1CoolCool 2 Size - The consumption rate of Stage 2CoolNOTIFICATION SETTINGSNotification Sensitivity - There are three levelsof notification settings: High, Medium, andLow. Setting the sensitivity changes howPelican notifies you on potential maintenanceissues.High - Send an immediate notification ifthe thermostat is calling for Heat orCool and the temperature is NOTreaching the set point.Medium - Send a notification if thetemperature is NOT moving towards oris moving away from the temperatureset-point for greater than 1 hour.Low - Send a notification if thetemperature is NOT moving towards oris moving away from the temperatureset-point and is at least 3 degrees offfrom the temperature set-point.Safe Range - Automatic monitoring option thatwill generate an immediate notification if thetemperature moves beyond these temperatureranges.PELICAN USER GUIDEChapter 2· 10

SCHEDULE SETTINGSNOTE: This is NOT where you schedule yourthermostat, these options effect thescheduling options available to you when youdo schedule your thermostat. Go to Page 19 3.3 Scheduling a Thermostat - for directionson scheduling a thermostat.Repeat - Set the thermostat to have Daily,Weekday/Weekend, or Weekly schedulingoptions.Daily - Same schedule everyday.Weekday/Weekend (5-2) - Differentschedules for Monday–Friday thanSaturday–Sunday.Weekly (7 day)- Different scheduleeveryday of the week.Set Times - Set the number of set times youwant available for each schedule. The defaultoptions are 2, 3, or 4. Selecting Variable allowsup to 12 set times in a single schedule.Multiple System Settings - Set to YES if youwant to change the System Setting (Auto, Heat,Cool, or OFF) using the schedule.Multiple Fan Settings - Set to YES if you wantto change the Fan Setting (Auto or ON) usingthe schedule.2.3 Add or Remove Administrators or UsersThe User Management screen allows you to add or remove Administrators or Users. NOTE: With the BasicSubscription you can only have a single Administrator. With the Standard or Enhanced Subscription you canhave an unlimited amount of Administrators or Users.1. If you are not on your Home screen press Back or navigate to your Pelican Home screen.2. Select Admin at the bottom of your Home screen.3. Select User Management from your Admin screen.4. To ADD a new Administrator or User pressthebutton found in the upper right handcorner of your Pelican Site Manager.PELICAN USER GUIDEChapter 2· 11

ADMINISTRATOR OPTIONSName - Input the name of the Administrator.Email - Input the email address for thisAdministrator. This email address will be used astheir Login Name and is where their temporarypassword will be sent.Type - Select Admin.Log Out* - There are four Log Out options: On Exit,After 1 Day, After 30 Days, Never. These are shownon the next page.USER OPTIONSName - Input the name of the User.Email - Input the email address for this User. Thisemail address will be used as their Login Name and iswhere their temporary password will be sent.Type - Select User.Log Out* - There are four Log Out options: On Exit,After 1 Day, After 30 Days, Never. These options areshown on the next page.View Notifications - Set if this User can see theNotifications for their viewable thermostats.View Usage Graphs - Set if this User can see theUsage Graphs for their viewable thermostats.Thermostat Access** - Set which thermostats thisUser can view, control, and/or manager. The optionsavailable are shown on the next pageDELETE AN ADMIN OR USERTo Delete an Administrator or User you must be anAdministrator for your Pelican Site Manager.1. Select the Administrator or User you want todelete.2. In the upper right hand corner of the UserManagement screen click thebutton.3. A confirmation screen will appear - Cancel to voidthis deletion or OK to accept it.PELICAN USER GUIDEChapter 2· 12

Log Out Options*LOG OUT OPTIONSOn Exit - When the Browser window isclosed.After 1 Day - One day after login.After 30 Days - 30 days after login.Never - Always remain logged in.User Access Options**USER ACCESS OPTIONSNo Access - Cannot see this thermostat.View Only - Can see thermostat’s temperaturebut, cannot control thermostat.Set & View - Can see thermostat’stemperature and control thermostat settings.Full Access - Has complete control overthermostat.2.4 Site Configuration OptionsSite Configuration is where you: view your Pelican Site Manager’s site information, add additional Gateways toyour Pelican Site Manager, input your KW and Therm costs, and input the email addresses or cell phonenumbers for receiving alert notifications. NOTE: Email and/or Text Message notifications are only availablewith the standard or enhanced subscriptions.1. If you are not on your Home screen press Back or navigate to your Pelican Home screen.2. Select Admin at the bottom of your Home screen.3. Select Site Configuration from your Admin screen.SITE CONFIGURATIONThe first box is your Pelican Site Manager’sURL.Type - Set if your building is used for aBusiness, Resident, or Hotel.Subscription - Displays the currentSubscription level for your Pelican Site. Thereare three Subscription Levels: Basic, Standard,and Enhanced.Gateway Serial No - The serial number of thePelican Gateway for this Pelican Site Manager.PELICAN USER GUIDEChapter 2· 13

Adding Additional Gateways:You can connect a total of 16 Pelican Gateways to a single Pelican Site Manager. NOTE: You should always addnew Gateways to your Pelican Site Manager before installing the Pelican Thermostats that will becommunicating through that new Pelican Gateways. Contact Pelican Support for further assistance.1. Install your new Pelican Gateway and check tomake sure it is able to reach the Internet.2. Record your New Pelican Gateway’s uniqueSerial Number. XXX-XXXX.3. Access your Pelican Site Manager selectAdmin select Site Configuration.3. Press theGateways.button next to Additional4. A window will appear - Input your New PelicanGateway’s serial number. If the serial numberyou input is invalid, a new window will appearwith the statement: Unrecognized or InvalidGateway Serial Number - Addition canceled.Press OK and check that the Pelican Gateway isinstalled correctly and is able to reach theInternet. If you continue to receive this errormessage contact Pelican Support.5. If the serial number is accepted - Select OK toaccept or select Cancel to void adding thisGateway.LOCATIONShows the location that your Pelican thermostats are installed in and the Time Zone they are using forscheduling.USAGE COSTSInputting your Kwh and Therm energy rates will allow Pelican to calculate the energy costs associated withrunning your HVAC units.1. Access your Pelican Site Manager and navigateto your Site Configuration page.2. Select either Cost/Kwh or Cost/Therm.PELICAN USER GUIDEChapter 2·14

Cost per Kilowatt HourCost per ThermInput your Cost per Kilowatt Hour and pressSave to add it to your Pelican Site Manager orCancel to discard the input.Input your Cost per Therm and press Save toadd it to your Pelican Site Manager or Cancelto discard the input.AUTOMATED EMAIL AND/OR TEXT MESSAGE NOTIFICATIONSThe Standard and Enhanced subscriptions allow you add an unlimited amount of email addresses or cellphone numbers that Pelican will automatically send alert notification too.1. Access your Pelican Site Manager and navigate toyour Site Configuration page.2. At the bottom of your Site Configuration pageyou will see two options:Email Notifications - Hit theto add anemail address for receiving emailnotifications.Text Message Notifications - Hit thetoadd a cell phone number for receiving textmessage notifications.Add Email AddressEnter the email address you want Pelican tosend email notifications to. Press Save to addthis email address or Cancel to void this input.Add Cell Phone NumberEnter the cell phone number and select itsCarrier you want Pelican to send text messagenotification to. Press Save to add this emailaddress or Cancel to void this input. (Standardtext rates apply).DELETE AN EMAIL ADDRESS OR CELL PHONENUMBERPress thebutton next to the email address orphone number of the person you want to delete.PELICAN USER GUIDEChapter 2·15

3. Pelican Thermostat (TS200, TS200H, TCM)3.1 Name and Configure a New Pelican ThermostatA Pelican Thermostat is initially identified by a unique serial number found on the bottom of the thermostat’sfront cover. The serial number will be in the form of XXX-XXXX.NOTE: We always recommend setting up a Default Thermostat Configuration before installing anythermostats, but this is not mandatory. Go to Page 8 - 2.2 Default Thermostat Configuration - for directions onsetting up a Default Thermostat Configuration.1. Log onto your Pelican Site Manager.2. Select Notifications.3. Under Notifications select the new Thermostatalert that has the same Serial Number as thethermostat you installed.4. Select.GENERAL SETTINGSName - Name this thermostat based on the locationit is placed in.Group - You can group multiple thermostatstogether on your Pelican Site Manager. Select thedown arrow and either select an already existinggroup or select “New Group” to create a new group.Description - An optional area for recording specificinformation about this HVAC unit or the thermostat.The first line of the Description area will show up assmall text below a Thermostat’s name (as seen inthe image to the right).Thermostat NameThermostat DescriptionFor all other configuration options refer to page 6 - 2.2 Default Thermostat Configuration.ACCESS AN EXISTING THERMOSTAT’S SETUP PAGE1. If you are not on your Home screen press Back or navigate to your Pelican Home screen.2. Select Admin at the bottom of your Home screen.3. Scroll down until you see the thermostat’s name orserial number you want to change the settings of. Selectits Thermostat Setup and it will direct you to its settingsscreen.PELICAN USER GUIDEChapter 3·16

TROUBLESHOOTING A THERMOSTAT’S RELAY OUTPUT SIGNALSWARNING: This option is used for testing and trouble shooting purposes only. Manually changing a SignalOutput overrides the internal Pelican thermostat’s logic. Always reset the output to its PREVIOUS setting.1. If you are not on your Home screen press Back or navigate to your Pelican Home screen.2. Select Admin at the bottom of your Home screen.3. Scroll down until you see the thermostat’s name orserial number you want to test/troubleshoot. Select itsThermostat Setup and it will direct you to its settingsscreen.4. Scroll down and select Testing: Signal Outputs.SIGNAL OUTPUTSBy pressing thebutton you can manually activateor deactivate that relay on your thermostat.A Black power icon with a Grey indicator bar meansthe relay is inactive.A Blue power icon with a Grey indicator bar meansthe relay is switching from inactive to active.A Black power icon with a Green indicator bar meansthe relay is active.A Blue power icon with a Green indicator bar meansthe relay is switching from active to inactive.WARNING: This option is used for testing and trouble shooting purposes only. Manually changing a SignalOutput overrides the internal Pelican thermostat’s logic. Always reset the output to its PREVIOUS setting.3.2 Controlling a Pelican Thermostat1. If you are not on your Home screen press Back or navigate to your Pelican Home screen.2. Select which Group the thermostat you want tocontrol is in.3. Select the Thermostat you want to control.PELICAN USER GUIDEChapter 3·17

THERMOSTAT CONTROLIn the upper right hand corner is the real-timetemperature being detected by this thermostat.System - Select to change the thermostat’s settingto Heat, Cool, Auto, or Off.Fan - Select to change the Fan to Auto or On.Front Keypad - Set to ON to Unlock thisthermostat’s keypad. Set to OFF to Lock thisthermostat’s keypad. If this setting option is notavailable go to page 9 - Thermostat Settings - AllowKeypad Control for further directions.NOTE: The only way to lock and unlock a thermostatis through the Pelican Site Manager. For safety andto retain control - if the Internet connection is lost,a locked Pelican thermostat will automaticallyunlock and then reset when the Internet is availableagain.Schedule - Select to setup a schedule for thisthermostat.Vacation Set Times - Select to setup a Vacationschedule for this thermostat to revert to whenVacation Mode is active.History - Graphically view the temperature andset-points that this thermostat has recorded.SETTING A TEMPERATURE1. On the thermostat control screen: Select Systemand set the thermostat to either Heat, Cool, orAuto.2. Sliders will appear - move a slider left or right toset the temperature.PELICAN USER GUIDEChapter 3·18

3.3 Scheduling a Thermostat1. Select Schedule and turn the Schedule from OFF to ON.If you have a Default Schedule setup, it will automaticallyupload into this thermostat’s schedule.Depending on how you configured this thermostat’s scheduling options will determine the options you see onits schedule screen. Go to Page 8 - SCHEDULE SETTINGS - for directions on how to setup scheduling options.OPTION 1 - The options to the right will be availableif this thermostat’s configuration is set to: MultipleSystems Settings and Multiple Fan Settings - NO.In this configuration the System, Fan, and FrontKeypad will always revert to the same settings youset here, when a schedule time starts.Front Keypad - Lock or Unlock the thermostat’skeypad when a scheduled time starts.Repeat - Set your Pelican thermostat to run on oneof the three different types of schedules: Daily,Weekday/Weekend, or Weekly.Daily - Same schedule everyday.Weekday/Weekend (5-2) - Differentschedule for Monday–Friday thanSaturday–Sunday.Weekly (7 day)- Different scheduleeveryday of the week.Settings - By selecting one of the Options underSettings, you will be brought to a new page forsetting up your Schedule Times.Variable Schedule TimesIf you have Variable selected for this thermostat’sconfiguration, on the schedule page, you will needto press thebutton to add additional StartTimes. NOTE: You can have up to 12 set times perday when you have selected Variable.Start Time - Select Start Time to generate a windowfor setting a start time. Slide the slider bars to selecta time.Heat/Cool Settings - Slide the slider bars to thetemperatures you want the heat and cool to be setto at this scheduled time.PELICAN USER GUIDEChapter 3·19

OPTION 2 - The options to the right will be availableif this thermostat’s configuration is set to: MultipleSystems Settings and Multiple Fan Settings - YES.In this configuration the System, Fan, and FrontKeypad can be changed uniquely for each scheduledtime.Repeat - Set your Pelican thermostat to run on oneof the three different types of schedules: Daily,Weekday/Weekend, or Weekly.Daily - Same schedule everyday.Weekday/Weekend (5-2) - Differentschedule for Monday–Friday thanSaturday–Sunday.Weekly (7 day)- Different scheduleeveryday of the week.Settings - By selecting one of the Options underSettings, you will be brought to a new page forsetting up your Schedule Times.Variable Schedule TimesIf you have Variable selected for this thermostat’sconfiguration, on the schedule page, you will needto press thebutton to add additional StartTimes. NOTE: You can have up to 12 set times perday when you have selected Variable.Start Time - Select Start Time to generate a windowfor setting a start time. Slide the slider bars to selecta time.System - Set the schedule to change thethermostat to Heat, Cool, Auto, or Off.Fan - Set the schedule to change the Fan to Auto orOn.Front Keypad - Set the schedule to Lock or Unlockthe thermostat’s keypad.PELICAN USER GUIDEChapter 3·20

3.4 Activating the Vacation SchedulesThere are two different ways to activate the Vacation Schedules. Either by enabling the One Touch VacationButton or by highlighting vacation days on the Vacation Calendar. NOTE: You have to add a vacation scheduleto each individual thermostat you want to run a vacation schedule for. Go to page 22 - 3.5 Setting up VacationSchedules - for further directions on how to add a vacation schedule to a thermostat.ONE TOUCH VACATION BUTTON1. If you are not on your Home screen press Back or navigate to your Pelican Home screen.2. Select Admin at the bottom of your Home screen.3. Select Vacation Settings from your Admin screen.4. Select One Touch Vacation.5. A window will appear: select Enabled to add the OneTouch Vacation Button to your Home Screen or Disableto remove the One Touch Vacation Button.USING THE ONE TOUCH VACATION BUTTONNOTE: You will need to Enable the One Touch Vacation option as shown above.1. If you are note on your Home screen press Back or navigate to your Pelican Home screen.2. You will see a new option that says Occupied:When Occupied the thermostats will operateusing their regular schedules.3. To switch between On Vacation and Occupiedpress the Briefcase Icon on your Home screen.A window will appear: select On Vacation to setyour Pelican Thermostats to Vacation Mode.When On Vacation the words next to the Briefcase Iconon your Home screen will be green.When On Vacation thermostats that HAVE vacationschedules will now revert to using their vacationschedules instead of their regular schedules.SETUP AND USE THE VACATION CALENDER1. If you are not on your Home screen press Back or navigate to your Pelican Home screen.2. Select Admin at the bottom of your Home screen.3. Select Vacation Settings from your Admin screen.4. By selecting days on the Vacation Calendar - Pelican will automatically set thermostats, that HAVE VacationSchedules, to Vacation Mode. Selecting vacation days for one year does NOT carry

Pelican Thermostat (TS200, TS200H, TCM) 3.1 Name and Configure a New Pelican Thermostat General Settings Access an Existing Thermostat’s Setup Page Troubleshooting a Thermostat’s Relay Output Signals 3.2 Controlling a Pelican Thermostat Thermostat Control Setting a Temperature 3.3 Scheduling a

Related Documents:

PELICAN CASE 3-4 Anatomy of a Pelican Case 5-8 Memory Card Cases/Micro Cases 9-10 Small Cases 11-14 Medium Cases 15-20 Digital Protection Cases 21-26 Large Cases 27-28 Long Cases 29-30 Pelican Organization Solutions 31-33 Pelican Case Specifications 34 Pelican Case Accessories PELICAN STORM CASE 35-36 Anatomy of a Pelican Storm Case 37 .

Pelican Wireless Systems * Pelican solution that includes: Pelican TS200 or TS200H (with a plus50 sensor) or a TS250 or TS250H Thermostat Pelican zone controller Z8 or Z24, or PEARL Economizer Pelican Extended Range Wireless

THERMOSTAT TEMPERATURE ONLY PELICAN TS200H THERMOSTAT TEMPERATURE AND HUMIDITY PELICAN TS250 THERMOSTAT . constant speed fan and SIEMENS GQD151 actuator (20 in-lbs.) with position feedback Output, 2 to 10 VDC Siemens GQD151 . Pelican Wireless Systems, 2655 Colli

PELICAN PRODUCTS FZE JAFZA One Building A office 1511/1512 Jebel Ali Free Zone gate 5 P.O.Box 261008 Dubai - United Arab Emirates Tel 971 4 8876550 Fax 971 4 8876549 www.pelican.com www.peli.com PELICAN HARDIGG 147 North Main Street South Deerfield, MA 01373 Tel (800) 542 73 44 Fax (413) 665 8330 www.pelican.com

PELICAN CARGO CASE SADDLE MOUNT, FLANGE, GEN 2 (SDDLMT2A) For Pelican BX55S, BX85S CARGO Cases in Truck Beds using factory bed-rail mounting. PELICAN PRODUCTS, INC. 23215 Early Avenue, Torrance, CA 90505 Pelican.com 310.326.4700 IMPORTANT WARNING! LATCHES AND MOUNTING KIT CARE

Pelican Cargo cases are the perfect solution to keep your valuable gear, clothing, tools, and even dry food organized, secured, and protected. Built with the same legendary performance and quality Pelican is known for, Pelican Cargo cases are extremely durable, weather tested, and feature a limited lifetime guarantee (cases only).

be performed by a qualified technician. This thermostat is designed for use with 24VAC systems only. For additional support contact Pelican Technical Support at 888-512-0490 or email support@pelicanwireless.com ! WARNING NEVER INSTALL THE PELICAN THERMOSTAT ENCLOSED IN METAL. WIRELESS CANNOT COMMUNICATE THROUGH METAL. Installation Guide Internet

Balance billing - When a health care provider bills a patient for a price beyond what is reimbursable from the patient’s health insurance. Base for payment - The base or unit of activity on which prices are set. Common base for payments are fee-for-service, diagnosis related groups, per diem, and capitation, for example. Base rate - The standardized payment amount that a provider receives .