GE ZONELINEParts & Accessories Guide

Our genuine parts& accessories deliverRELIABLECOMFORTOnly genuine parts and accessoriesfrom GE Appliances keep your Zoneline units running in peak condition. Ourparts and accessories are constructedfrom high-quality materials for aguaranteed fit, convenient replacementand constant comfort.CONTENTS4-14 Z ONELINE PARTSAND ACCESSORIES15 ZONELINE.COM INFO16 VERTICAL ZONELINE18 ORDER INFORMATION2

geappliances.com / zoneline.com3

ZONELINE RAB71A(ALL ZONELINE SERIES*)RAB71B(AZ45/65 SERIES*)WALL CASEWALL CASE Universal design Universal design Galvanized steel Galvanized steel Expanded polystyrene foam insulation Expanded polystyrene foam insulation Baked-on enamel Baked-on enamel Protected with a sealing compound to prevent rust Protected with a sealing compound to prevent rust Sealing compound Color matched for AZ45/65 seriesAlso available with extended depthsRAB7116: 16" deep RAB7128: 28" deepRAB7124: 24" deep RAB7131: 31" deepAlso available with extended depthsRAB7116B: 16" deepRAB7124B: 24" deepRAB77A4(ALL ZONELINE SERIES*)RAB77B(AZ45/65 SERIES*)SMC WALL CASESMC WALL CASE Universal design Universal design Non-corrosive Non-corrosive Constructed with fiberglass-reinforced polyester compound Constructed with fiberglass-reinforced polyester compound Color matched for AZ45/65 series4

RAD10(ALL ZONELINE SERIES)RAG61/62/63(AZ SERIES) INTERNAL/EXTERNAL DRAIN KITARCHITECTURAL REAR GRILLE Provides positive control of condensate water Improves appearance and protection R outes condensate to exterior or interior of the building Molded of high-impact polycarbonate Suitable provision (field applied) required for connectionto drain system Slightly textured, colorfast surface blends with most walls 1/2" OD copper assembliesRAG61: Beige RAG62: Maple RAG63: Dark Brown Includes short right-angle tube and 6"-long straight tubeRAG60(AZ SERIES)RAG67(AZ SERIES)STAMPED ALUMINUM EXTERIOR REAR GRILLEALUMINUM ARCHITECTURAL OUTDOOR GRILLE Standard size Extruded aluminum outdoor grille Protects chassis components Grilles are paintable to match building décor Optimizes air flow Made of durable aluminumA–B series: Zoneline units built before 1987 – Zoneline I, II, III,and IV; AZC series: Zoneline units built from 1987 to 1992 –Zoneline 1000, 2000, 2500, 2700, 3000, 4000, 5000; AZ series:Zoneline units built after 1992 – Zoneline 21, 31, 26, 51 /Zoneline 22, 32, 52 / Zoneline 25, 35, 55 / Zoneline 28, 29, 38,39, 41, 45, 58, 61, 65, 75, 85.*Available while quantities lastgeappliances.com / zoneline.com5

ZONELINE PARTS & ACCESSORIESRAF452A while quantities last(AZ SERIES—25, 35 & 55 ONLY)WP71X20960(AZ SERIES—45 & 65 ONLY)REPLACEMENT ROOM CABINETREPLACEMENT ROOM CABINET Wraparound design with textured finish Wraparound design with textured finish Injection-molded of high-impact polystyrene Injection-molded with high-impact polystyrene Fastens to chassis without tools or hardware Fastens to chassis without tools or hardware Contains slide-out filters and 2-position reversibledischarge louvers Contains slide-out filters Color matched for AZ45/65 series Available through geappliancesparts.comRAF452 while quantities last(AZ SERIES—22, 32 & 52 ONLY)REPLACEMENT ROOM CABINET Wraparound design with textured finish Injection-molded of high-impact polystyrene Fastens to chassis without tools or hardware Contains slide-out filters and 2-position reversibledischarge louversRAK40(AZ SERIES)AIR DEFLECTOR KIT Adapts AZ chassis for use with older GE architectural grilles A luminum deflector installed to condenser end sheet flanges toprevent condenser airflow recirculation Also fits custom rear grilles7-3/32"6-1/2"RAF453A while quantities lastWP71X10029 Also available through geappliancesparts.com(AZ SERIES—28, 29, 38, 39, 41, 58 & 61 ONLY)RAK6052(AZ SERIES—22, 25, 28, 29, 32, 35, 38, 39, 41 & 61 ONLY)REPLACEMENT ROOM CABINETDUCT ADAPTER (Not for 45, 52, 55, 58 or 65 Series) Allows Zoneline unit to heat or cool an adjacent room Wraparound design with textured finish Attaches to top of wall case Injection-molded with high-impact polystyrene Can be applied to right or left of adapter Fastens to chassis without tools or hardware Zoneline 26 and 51 series not approved for ducted application Contains slide-out filters and 2-position reversibledischarge louvers6

8-3/8"7-3/32"6-1/2"6-1/2"RAK6053(AZ SERIES—45 & 65 ONLY)RAK7012(AZ SERIES—22, 25, 32, 35, 28, 29, 38, 39, 41 & 61)DUCT ADAPTERDUCT ADAPTER FOR REPLACEMENT OF A–BWITH ROUNDED-FRONT AZ CHASSIS Allows Zoneline unit to heat or cool an adjacent room Attaches to top of wall case Can be applied to right or left of adapter Color matched for AZ45/65 series Lines up with duct extension where original chassis wasa flat-top discharge A-B series A llows existing duct extension to be used without requiringrelocation of wall hole Must use discharge grille, end plate and extension mountinghardware from old duct adapterRAK601/602(AZC & AZ SERIES—21, 22, 25, 28, 29, 31, 32, 35, 38,39, 41 & 61 ONLY)DUCT EXTENSION, REGISTER & TRIM FLANGE 44" long Includes air register and trim flange for secondary space Additional air register and trim flange (RAK602) can be orderedseparately if two extensions are made For use with RAK6052RAK7013(AZ SERIES—45 & 65 ONLY)DUCT ADAPTER FOR REPLACEMENT OF A–BWITH SLANTED-FRONT AZ CHASSIS Lines up with duct extension where original chassis wasa flat-top discharge A-B Series A llows existing duct extension to be used without requiringrelocation of wall hole Must use discharge grille, end plate and extension mountinghardware from old duct adapter Color matched for AZ45/65 seriesRAK601B/602B(AZ SERIES—45 & 65 ONLY)DUCT EXTENSION, REGISTER & TRIM FLANGE 44" long Includes air register and trim flange for secondary space Additional air register and trim flange can be orderedseparately if two extensions are made For use with RAK6053 Color matched for AZ45/65 series –B series: Zoneline units built before 1987 – Zoneline I, II, III,Aand IV; AZC series: Zoneline units built from 1987 to 1992 –Zoneline 1000, 2000, 2500, 2700, 3000, 4000, 5000; AZ series:Zoneline units built after 1992 – Zoneline 21, 31, 26, 51 /Zoneline 22, 32, 52 / Zoneline 25, 35, 55 / Zoneline 28, 29, 38,39, 41, 45, 58, 61, 65, 75, 85.geappliances.com / zoneline.com7

ZONELINE PARTS & ACCESSORIESChasewayPower cord and junction boxnot included with sub-base.RAK7022(AZ SERIES—22, 25, 28, 29, 32, 35, 38, 39, 41& 61 ONLY)DUCT TRANSITION FOR REPLACEMENTOF AZC WITH ROUNDED-FRONT AZ CHASSIS A llows duct installation where original chassis was a slope-frontdischarge chassis (AZC/AZR/AZ21/AZ31) A llows existing duct extension to be used without requiringrelocation of wall holeRAK204(AZ SERIES)SUB-BASES Made of heavy-gauge steel Full base enclosure with breakaway side channels 4-point leveling legs Sub-base adapts to service conduit, circuit breakers and receptaclesup to 30 amps May also be used as a non-electrical sub-base to support the unitKIT otIncludedRAK7023(AZ SERIES—45 & 65 ONLY)ChasewayDUCT TRANSITION FOR REPLACEMENTOF AZC WITH SLANTED-FRONT AZ CHASSIS A llows duct installation where original chassis was a slope-frontdischarge chassis (AZC/AZR/AZ21/AZ31) A llows existing duct extension to be used without requiringrelocation of wall hole Color matched for AZ45/65 seriesRAK204D(AZ SERIES —EXCLUDES 45 & 65)SUB-BASES WITH POWER CORD INCLUDED Made of heavy-gauge steel Full base enclosure with breakaway side channels 4-point leveling legs Sub-base adapts to service conduit, circuit breakers andreceptacles up to 30 amps May also be used as a non-electrical sub-base to support the unit 9-pin cludedIncludedKIT NO.SUB-BASERAK204D15P

ChasewayRAK204D(AZ SERIES—45 & 65 ONLY)SUB-BASES WITH POWER CORD INCLUDED Made of heavy-gauge steel Full base enclosure with breakaway side channels 4-point leveling legs Sub-base adapts to service conduit, circuit breakers andreceptacles up to 30 amps May also be used as a non-electrical sub-base to support the unit 4-pin ludedIncludedKIT NO.SUB-BASERAK204D15CRAK205CW(AZ SERIES)CHASEWAY For wiring containment between junctionbox on chassis and RAK204U sub-baseA–B series: Zoneline units built before 1987 – Zoneline I, II, III,and IV; AZC series: Zoneline units built from 1987 to 1992 –Zoneline 1000, 2000, 2500, 2700, 3000, 4000, 5000; AZ series:Zoneline units built after 1992 – Zoneline 21, 31, 26, 51 /Zoneline 22, 32, 52 / Zoneline 25, 35, 55 / Zoneline 28, 29, 38,39, 41, 45, 58, 61, 65, 75, 85.*RAK204U May be used with AZC and AZ 21, 31, 26 and 51.geappliances.com / zoneline.com9

ZONELINE PARTS & ACCESSORIESRAK4157/4207/4307†(AZ SERIES—28, 29, 38, 39, 41, 55, 58& 61 ONLY)230/208-VOLT UNIVERSALPOWER SUPPLY KIT 9-pin connector with three 7" 12-gaugeconductor wiresRAK5157/5207/5307†(AZ SERIES—28, 29, 38, 39, 41, 55, 58& 61 ONLY)265-VOLT UNIVERSAL POWERSUPPLY KIT 9-pin connector with three 7" 12-gaugeconductor wiresRAK3153A/3203A/3303A†(AZ SERIES—28, 29, 38, 39, 41, 55, 58& 61 ONLY)15 & 20 AMP (230/208 VOLTS)UNIVERSAL POWER SUPPLYWITH LCDIKIT 2.4/2.32 kw15RAK4207230/2083.3/3.2 kw20RAK4307230/2084.7/4.53 kw30KIT NO.VOLTSHEATERWATTAGECIRCUITAMPACITYRAK51572652.4 kw15RAK52072653.4 kw20RAK53072654.8 kw30KIT 82.4/2.32 kw15RAK3203A230/2083.3/3.2 kw20RAK3303A230/2084.7/4.53 kw30KIT NO.VOLTSHEATERWATTAGECIRCUITAMPACITY 9-pin connector with three 7" 12-gaugeconductor wiresRAK5172/5202/5302†(AZ SERIES—28, 29, 38, 39, 41, 55, 58& 61 ONLY)15, 20, & 30 AMP (265 VOLTS)UNIVERSAL POWER SUPPLY Branch circuit plug to be used only inconnection to appropriate sub-baseRAK51722652.4 kw15RAK52022653.4 kw20RAK53022654.8 kw30 9-pin connector with three 7" 12-gaugeconductor wiresA–B series: Zoneline units built before 1987 – Zoneline I, II, III,and IV; AZC series: Zoneline units built from 1987 to 1992 –Zoneline 1000, 2000, 2500, 2700, 3000, 4000, 5000; AZ series:Zoneline units built after 1992 – Zoneline 21, 31, 26, 51 /Zoneline 22, 32, 52 / Zoneline 25, 35, 55 / Zoneline 28, 29, 38,39, 41, 45, 58, 61, 65, 75, 85.† The power connection kit determines the heater wattage and current requirements when it is plugged into the Zoneline unit.NOTE: 7,000 BTU models do not have 5,000-watt heaters. ††Heater wattage may vary slightly among models. 30-amp heater wattage is reduced in low fan operation.10

RAK315D/320D/330D††RAK330D shown(AZ SERIES—45 & 65 ONLY)230/208-VOLT DIRECT CONNECTPOWER SUPPLY KIT 4-pin connector with three 7" 12-gaugeconductor wires and low-voltagepersonality plug on 20 ampand 30 amp kitsKIT 2.4/1.99 kw15RAK320D230/2083.4/2.8 kw20RAK330D230/2084.8/3.99 kw30KIT NO.VOLTSHEATERWATTAGECIRCUITAMPACITY Junction box includedRAK515D/520D/530D††RAK530D shown(AZ SERIES—45 & 65 ONLY)265-VOLT UNIVERSAL DIRECTCONNECT POWER SUPPLY KIT 4-pin connector with three 7" 12-gaugeconductor wires and low-voltagepersonality plug on 20 ampand 30 amp kitsRAK315P/320P/330P††RAK320P shown(AZ SERIES—45 & 65 ONLY)230/208-VOLT UNIVERSALPOWER CORD KIT Six-foot power cord with LCDIRAK515D2652.4 kw15RAK520D2653.4 kw20RAK530D2654.8 kw30KIT 2.4/1.96 kw15RAK320P230/2083.4/2.8 kw20RAK330P230/2084.8/3.99 kw30KIT 82.4/1.96 kw15 4-pin connector Low-voltage personality plugon 20 amp and 30 amp kitsRAK315SP/320SP/330SP††RAK315SP shown(AZ SERIES—45 & 65 ONLY)230/208-VOLT UNIVERSAL SHORTPOWER CORD KIT Three-foot power cord WITHOUT LCDIRAK320SP230/2083.4/2.8 kw20RAK330SP230/2084.8/3.99 kw30KIT NO.VOLTSHEATERWATTAGECIRCUITAMPACITY 4-pin connector Low-voltage personality plugon 20 amp and 30 amp kits Only for use in existing sub-baseswith new AZ45/65 units Junction box includedRAK515P/520P/530P††RAK520P shown(AZ SERIES—45 & 65 ONLY)265 VOLTS UNIVERSAL POWERSUPPLY Three-foot power cord WITHOUT LCDIRAK515P2652.4 kw15RAK520P2653.4 kw20RAK530P2654.8 kw30 4-pin connector Low-voltage personality plugon 20 amp and 30 amp kits Only for use in existing sub-bases andwith new AZ45/65 unitsgeappliances.com / zoneline.com11

ZONELINE PARTS & ACCESSORIESRAK4002A(AZ SERIES—25, 28, 29, 35, 38, 39, 41& 61 ONLY)DIRECT-CONNECT JUNCTION BOX(230/208 & 265 VOLTS) K it for permanent connection of 230/208and 265-volt units to building power supply Includes multi-circuit connector harnessfor use on value line units Junction box is included on 265-volt unitsRAK8022 while quantities last(AZ SERIES—22, 25, 32, 35, 52 & 55 ONLY)LOCKING DOOR KIT Prevents access to Zoneline unit controlsRAK4002B while quantities last(AZ SERIES—55 & 58 ONLY)DIRECT-CONNECT JUNCTION BOX(230/208 & 265 VOLTS) Includes key Provides two thumb screws for securing the room cabinetto the chassis on the lower right and left side K it for permanent connection of 230/208and 265-volt units to building power supply Includes multi-circuit connector harnessfor use on value line units Junction box is included on 265-volt unitsRAK4002C(AZ SERIES—45 & 65 ONLY)DIRECT-CONNECT JUNCTION BOX(230/208 AND 265 VOLTS) K it for direct connection of 230/208-voltand 265-volt units to building power supply Junction box is included on 265-volt units Junction box is included with RAK315,RAK320, RAK330, RAK315SP, RAK320SPand RAK330SPRAK8023 while quantities last(AZ SERIES—28, 29, 38, 39, 41, 58 & 61 ONLY)LOCKING DOOR KIT Prevents access to Zoneline unit controls Includes key Provides two thumb screws for securing the room cabinetto the chassis on the lower right and left sideRAK4002CW while quantities last(AZ SERIES—EXCLUDES 45 & 65)DIRECT-CONNECT JUNCTION BOXWIRING (230/208 & 265 VOLTS) In-line 3-pin connector and wiring harness A llows easy disconnect of direct-connectedapplications12

RAA62 while quantities last(AZ SERIES—22, 32 & 52 ONLY)REPLACEMENT FILTERSFOR AZ MODELS 10 pairs per box Sold in pairs Conveniently accessible throughthe front of the unitRAK806(AZ SERIES—EXCLUDES 45 & 65)UNIVERSAL COVER LABEL(10 COVERS PER KIT) Covers control area, referring room occupant to usea remote thermostat Double-sided adhesive providedRAA62A while quantities last(AZ SERIES—25, 35 & 55 ONLY)REPLACEMENT FILTERS 10 pairs per box Sold in pairs Conveniently accessible throughthe front of the unitRAK901L while quantities last(AZ SERIES) WALL CASE INSULATION KIT Five pieces of 13" x 14" x 1/4" adhesive-backed polyethylene Insulates inside of RAB71A or RAB71B wall caseRAA63(AZ SERIES—28, 29, 38, 39, 41,58 & 61 ONLY) Minimizes the formation of moisture on wall case exteriorREPLACEMENT FILTERS 10 pairs per box Sold in pairs Conveniently accessible throughthe front of the unitRAKCDC(AZ SERIES—45 & 65 ONLY) CDC WIRING CONNECTOR 3-wire connector Works with Central Desk Control systemand thru wall fan option External fan optionRAA64(AZ SERIES—45 & 65 ONLY)REPLACEMENT FILTERS One pair per box Sold in pairs Conveniently accessible through the front of the unit –B series: Zoneline units built before 1987 – Zoneline I, II,AIII, and IV; AZC series: Zoneline units built from 1987 to 1992– Zoneline 1000, 2000, 2500, 2700, 3000, 4000, 5000; AZseries: Zoneline units built after 1992 – Zoneline 21, 31, 26, 51 /Zoneline 22, 32, 52 / Zoneline 25, 35, 55 / Zoneline 28, 29, 38,39, 41, 45, 58, 61, 65, 75, 85.geappliances.com / zoneline.com13

ZONELINE PARTS & ACCESSORIESAZ45 SERIESAZ65 SERIESRAK164D2(AZ 25, 28, 29, 41, 45, 75 & 85)RAK148D2(AZ 35, 38, 39, 55, 58, 61, 65, 75 & 85)COOLING WITH ELECTRICHEAT DIGITAL REMOTETHERMOSTATHEAT PUMP DIGITAL REMOTETHERMOSTAT 24V AC digital remote wallthermostat with single-stagecooling and single-stage heatingfor resistance heat models 24V AC digital remote wall thermostatwith single-stage cooling and 2-stageheating for heat pump models R equires 6-wire hookup R equires 5-wire hookupRAK164F2(AZ 25, 28, 29,41,45,75 & 85)RAK148F2(AZ 35, 38, 39, 55, 58, 61, 65, 75 & 85)DIGITAL TWO FAN SPEEDTHERMOSTAT FOR ELECTRICRESISTANCEDIGITAL TWO FAN SPEEDTHERMOSTAT FOR HEAT PUMP Two fan speeds 24V AC digital remote wall thermostatwith single-stage cooling and 2-stageheating for heat pump models 24V AC digital remote wallthermostat with single-stage coolingand single-stage heating forresistance heat models Two fan speeds Requires 6-wire hookup Requires 5-wire hookupRAK164P2(AZ 25, 28, 29, 41, 45, 75 & 85)RAK148P2(AZ 35, 38, 39, 55, 58, 61, 65, 75 & 85)COOLING WITH ELECTRICHEAT PROGRAMMABLEREMOTE THERMOSTATHEAT PUMP PROGRAMMABLEREMOTE THERMOSTAT 24V AC programmable remotewall thermostat with single-stagecooling and single-stage heating forresistance heat models Programmable for 7-day or5 2-day programs 24V AC programmable remote wallthermostat with single-stage cooling and2-stage heating for heat pump models Programmable for 7-day or 5 2-dayprograms R equires 6-wire hookup R equires 5-wire hookupA–B series: Zoneline units built before 1987 – Zoneline I, II,III, and IV; AZC series: Zoneline units built from 1987 to 1992– Zoneline 1000, 2000, 2500, 2700, 3000, 4000, 5000; AZseries: Zoneline units built after 1992 – Zoneline 21, 31, 26, 51 /Zoneline 22, 32, 52 / Zoneline 25, 35, 55 / Zoneline 28, 29, 38,39, 41, 45, 58, 61, 65, 75, 85.14

GE APPLIANCES ZONELINE WARRANTYFOR THE PERIOD OFGE APPLIANCES WILL REPLACEONE YEARAny part of the air conditioner which fails due to a defect in materials or workmanship. Duringthis limited one-year warranty, GE will provide, free of charge, all labor and related service coststo replace the defective part.FIVE YEARSSealed Refrigerating System, if any part of the Sealed Refrigerating System (the compressor,condenser, evaporator, and all connecting tubing) should fail due to a defect in materials orworkmanship. During this limited five-year warranty, GE will provide, free of charge, all laborand related service costs to replace the defective part.SECOND THROUGHFIFTH YEARFan Motors, Switches, Thermostat, Heater, Heater Protectors, Compressor Overload,Solenoids, Circuit Boards, Auxiliary Controls, Thermistors, Freeze Sentinel, Frost Controls,ICR Pump, Capacitors, Varistors and Indoor Blower Bearing, if any of these parts should faildue to a defect in materials or workmanship. During this additional four-year limited warranty,the customer will be responsible for any labor and related service costs.From the date of theoriginal purchaseFrom the date of theoriginal purchaseFrom the date of theoriginal purchaseHOW TO ORDERCall or go online to get the products, parts and accessories you need from GE Appliances.ZONELINE.COM GEAPPLIANCES.COM GEAPPLIANCEPARTS.COM 800.432.2737 – GE FACTORY SERVICEORDER GE APPLIANCES PARTS DIRECTYOUR PRODUCT INFORMATION:When you order GE Appliances Parts direct, you’llbe backed by quality and support you can count on:Locate your Zoneline’s serial number: Original genuine parts Find the base pan, located at the bottom of the unit Limited 1-year warranty Serial number will be printed on the base pan Remove cover Discounts and promotions Access to illustrated parts catalogMY ACCOUNT NUMBER Check status and availabilityApply for credit, speak to a GE Appliances PartsSpecialist or buy genuine GE Appliances Parts at:MY SALES MANAGERGECUSTOMERNET.COM 800.851.6200geappliances.com / zoneline.com15

VERTICAL ZONELINE 16RAVWP6(AZ SERIES—75/85)RAVWP12(AZ SERIES—75/85)WALL PLENUMWALL PLENUM Wall plenum for installation in wallsless than 6" thick Wall plenum for installation in wallsless than 12" thick Wall plenum 19-3/4" x 32" Wall plenum 19-3/4" x 32" Wall cutout dimensions 20" x 32-1/4" Wall cutout dimensions 20" x 32-1/4" Warm gray-beige color Warm gray-beige colorRAVWP8(AZ SERIES—75/85)RAVWP15(AZ SERIES—75/85)WALL PLENUMWALL PLENUM Wall plenum for installation in wallsless than 8" thick Wall plenum for installation in wallsless than 15" thick Wall plenum 19-3/4" x 32" Wall plenum 19-3/4" x 32" Wall cutout dimensions 20" x 32-1/4" Wall cutout dimensions 20" x 32-1/4" Warm gray-beige color Warm gray-beige color

RAVAL1(AZ SERIES—75/85)ALUMINUM OUTDOOR GRILLE Extruded aluminum outdoor grille forinstallation on RAVWP series wall plenums Grille is 19-3/4" x 32" x 1-1/4" M ill finishRAK5157/5207/5307†(AZ SERIES—75/85)265-VOLT UNIVERSALPOWER SUPPLY KIT 9-pin connector with three 7" 12-gaugeconductor wiresKIT NO.RAVRG1(AZ SERIES—75/85)ACCESS PANEL WITH RETURNAIR .71 kw15RAK52072653.55 kw20RAK53072655.03 kw30 Access panel with return air grille forinstallation in closet wall A llows access/removal of VerticalZoneline for cleaning or service Outside dimensions 30" x 50" Wall cutout dimensions 28" x 48" Accepts 20" x 20" x 1" field-supplied filter Warm gray-beige colorRAVRG2(AZ SERIES—75/85)RETURN AIR GRILLERAK4157/4207/4307†(AZ SERIES—75/85)230/208-VOLT UNIVERSALPOWER SUPPLY KIT 9-pin connector with three 7" 12-gaugeconductor wires R eturn air grille for installationin closet wallKIT 2,610/2,19015 Exterior dimensions 22-1/2" x 22-1/2"RAK4207230/2083,420/2,87020 Wall cutout dimension 20-3/8" x 20-3/8"RAK7307230/2084,810/4,07030 Accepts 20" x 20" x 1" field-supplied filter Warm gray-beige colorRAVRMS while quantities last(AZ SERIES—75/85)WALL-MOUNTED ROOMAIR SENSOR Wall-mounted room air sensorprovides Temperature Limiting andFreeze Sentinel capability Includes 3-meter conductor wire forhook-up to Vertical Zoneline R equired for Motion Sensor/DoorSwitch applicationsA–B series: Zoneline units built before 1987 – Zoneline I, II,III, and IV; AZC series: Zoneline units built from 1987 to 1992– Zoneline 1000, 2000, 2500, 2700, 3000, 4000, 5000; AZseries: Zoneline units built after 1992 – Zoneline 21, 31, 26, 51 /Zoneline 22, 32, 52 / Zoneline 25, 35, 55 / Zoneline 28, 29, 38,39, 41, 45, 58, 61, 65, 75, 85.RAK3152/3202/3302†(AZ SERIES—75/85)15, 20, & 30 AMP (230/208 VOLTS)UNIVERSAL POWER SUPPLYKIT /2084,810/4,07030† The power connection kit determines the heater wattage and currentrequirements when it is plugged into the Zoneline unit. NOTE: 7,000 BTUmodels do not have 5,000-watt heaters.geappliances.com / zoneline.com17

ORDER INFORMATIONZONELINE PARTS & eplacement filters for AZ models (10 pairs per box) for 22, 32 & 52 onlyReplacement filters (10 pairs per box) for 25, 35 & 55 onlyReplacement filters (10 pairs per box) for 28, 38, 41, 45, 58, 61 & 65 onlyReplacement filters (one pair per box) for 45 & 65 RAK204D15PCRAK204D20PCRAK204D30PCWall caseSMC wall caseWall case, 45 & 65 onlyWall case, 16"Wall case, 24"Wall case, 28"Wall case, 31"Wall case, 16", 45 & 65 onlyWall case, 24", 45 & 65 onlySMC wall case, 45 & 65 onlyInternal/external drain kitReplacement room cabinet (2-position louvers) for 22, 32 & 52 onlyReplacement room cabinet (2-position louvers) for 25, 35 & 55 onlyReplacement room cabinet (2-position louvers) for 28, 29, 38, 39, 41, 58 and 61 onlyReplacement room cabinet (2-position louvers) for 45 & 65 onlyStamped aluminum exterior rear grilleArchitectural rear grille, beigeArchitectural rear grille, mapleArchitectural rear grille, dark brownAluminum architectural outdoor grilleAir deflector kitDirect-connect junction box 230/208V for 25, 35, 28, 29, 38, 39, 41, 45, 61 & 65 onlyDirect-connect junction box 230/208V for 55, 58 onlyDirect-connect junction box, 230/208V and 265V for 45 & 65 onlyDirect-connect junction box wiring, 230/208V and 265V excludes 45 & 65Universal power supply, 15 amp for 45 & 65 onlyUniversal power supply, 20 amp for 45 & 65 onlyUniversal power supply, 30 amp for 45 & 65 only230/208V Universal power supply, 15 amp for 45 & 65 only230/208V Universal power supply, 20 amp for 45 & 65 only230/208V Universal power supply, 30 amp for 45 & 65 only265V Universal power supply, 15 amp for 45 & 65 only265V Universal power supply, 20 amp for 45 & 65 only265V Universal power supply, 30 amp for 45 & 65 only230/208V Universal power supply, short, 15 amp for 45 & 65 only230/208V Universal power supply, short, 20 amp for 45 & 65 only230/208V Universal power supply, short, 30 amp for 45 & 65 only265V Universal power supply, 15 amp for 45 & 65 only265V Universal power supply, 20 amp for 45 & 65 only265V Universal power supply, 30 amp for 45 & 65 only230/208V Universal power supply, 15 amp for 28, 29, 38, 39, 41, 55, 58 and 61 only230/208V Universal power supply, 20 amp for 28, 29, 38, 39, 41, 55, 58 and 61 only230/208V Universal power supply, 30 amp for 28, 29, 38, 39, 41, 55, 58 and 61 only265V Universal power supply, 15 amp for 28, 29, 38, 39, 41, 55, 58 and 61 only265V Universal power supply, 20 amp for 28, 29, 38, 39, 41, 55, 58 and 61 only265V Universal power supply, 30 amp for 28, 29, 38, 39, 41, 55, 58 and 61 only230/208V Universal power supply, 15 amp for 28, 29, 38, 39, 41, 55, 58 and 61 only230/208V Universal power supply, 20 amp for 28, 29, 38, 39, 41, 55, 58 and 61 only230/208V Universal power supply, 30 amp for 28, 29, 38, 39, 41, 55, 58 and 61 onlyUniversal power supply, 15 amp, 265V for 28, 29, 38, 39, 41, 55, 58 & 61 onlyUniversal power supply, 20 amp, 265V for 28, 29, 38, 39, 41, 55, 58 & 61 onlyUniversal power supply, 30 amp, 265V for 28, 29, 38, 39, 41, 55, 58 & 61 onlyChaseway for RAK204U sub-base230/208V, 15 amp sub-base with power cord, excludes 45 & 65230/208V, 20 amp sub-base with power cord, excludes 45 & 65230/208V, 30 amp sub-base with power cord, excludes 45 & 65230/208V, 15 amp sub-base with power cord, 45 & 65 only230/208V, 20 amp sub-base with power cord, 45 & 65 only230/208V, 30 amp sub-base with power cord, 45 & 65 only18MODEL TYPEAZAZAZAZPAGE NO.13131313All ZonelineAll AZAll AZAZ

ZONELINE PARTS & DCDESCRIPTION265V, 15 amp sub-base265V, 20 amp sub-base265V, 30 amp sub-baseSub-base without electrical devices or wiringDuct extensionAir register and trim flangeDuct extension for 45 & 65 onlyAir register and trim flange for 45 & 65 onlyDuct adapter for 22, 32, 25, 35, 28, 29, 38, 39, 41 & 61 onlyDuct adapter for 45 & 65 onlyDuct adapter for replacement of A-B with rounded-front AZ chassis for 22, 32, 25, 35, 28, 29, 38, 39,41 & 61 onlyDuct adapter for replacement of A-B with slated-front AZ chassis for 45 & 65 onlyDuct transition for replacement of AZC with rounded-front AZ chassis for 22, 32, 25, 35, 28, 29, 38, 39, 41,45, 61 & 65 onlyDuct transition for replacement of AZC with slanted-front AZ chassis for 45 & 65 onlyLocking door kit for 22, 25, 32, 35, 52 & 55 onlyLocking door kit for 28, 29, 38, 39, 41, 58 & 61 onlyUniversal cover label (10 covers per kit), excludes 45 & 65Wall case insulation kitCDC Wiring Connector for 45 & 65 onlyMODEL TYPEAZAZAZAZAZC, AZAZC, AZAZAZAZAZPAGE F2RAK164P2DESCRIPTIONHeat pump digital remote thermostatHeat Pup digital 2 fan speed remote thermostatHeat pump programmable remote thermostatCooling with electric heat digital remote thermostatCooling with electric heat 2 fan speeds digital remote thermostatCooling with electric heat programmable remote thermostatVERTICAL ZONELINE VWP6RAVWP8RAVWP12RAVWP15DESCRIPTION230/208V power connection kit (15 amp) for line-cord-connected units vertical series230/208V power connection kit (20 amp) for line-cord-connected units vertical series230/208V power connection kit (30 amp) for line-cord-connected units vertical series230/208V power connection kit (15 amp) for permanently connected units230/208V power connection kit (20 amp) for permanently connected units230/208V power connection kit (30 amp) for permanently connected units265V power connection kit (15 amp) for permanently connected units265V power connection kit (20 amp) for permanently connected units265V power connection kit (30 amp) for permanently connected unitsExterior grille—19-3/4" W x 32" HAccess panel—28" W x 48" H cutoutReturn air grille—20-3/8" W x 20-3/8" H cutoutFreeze Sentinel/Temperature-limiting room sensorWall plenum for up to 6" thick wallsWall plenum for up to 8" thick wallsWall plenum for up to 12" thick wallsWall plenum for up to 15" thick wallsPAGE NO.141414141414MODEL TYPEAZAZAZAZAZAZAZAZAZA

units running in peak condition. Our parts and accessories are constructed from high-quality materials for a guaranteed fit, convenient replacement and constant comfort. Our genuine parts & accessories deliver RELIABLE COMFORT CONTENTS 4-14 ZONELINE PARTS AND ACCESSORIES

Related Documents:

6 www.amana-ptac.com Nomenclature 1,2,3 4,5 6 7 8,9 14,15 Basic Model Type Engineering PTC Standard Cooler PTAC Major & Minor Revisions PTH Standard Heat Pump PTHP HEH High- ‐Efficiency Heat Pump Features Code * 32C High-Efficiency R32 Cooler PTAC A Standard Model PMC DigiAIR Cooler PTAC C Corrosion Protection (Seacoast)

6 www.amana-ptac.com Nomenclature. 1,2,3 4,5 6 7 8,9 14,15 Basic Model Type Engineering PTC Standard Cooler PTAC Major & Minor Revisions PTH Standard Heat Pump PTHP HEH High- ‐Efficiency Heat Pump Features Code * A PMC DigiAIR Cooler PTAC C PMH DigiAIR Heat Pump PTAC D Nominal Cooling Capacity* L 07 7,000 BTU/h 60 Hz H

6 www.amana-ptac.com Nomenclature. 1,2,3 4,5 6 7 8,9 14,15 Basic Model Type Engineering PTC Standard Cooler PTAC Major & Minor Revisions PTH Standard Heat Pump PTHP HEH High- ‐Efficiency Heat Pump Features Code * A PMC DigiAIR Cooler PTAC C PMH DigiAIR Heat Pump PTAC D Nominal Cooling Capacity* L 07 7,000 BTU/h 60 Hz H

6 www.amana-ptac.com Nomenclature 1,2,3 4,5 6 7 8,9 14,15 Basic Model Type Engineering PTC Standard Cooler PTAC Major & Minor Revisions PTH Standard Heat Pump PTHP HEH High- ‐Efficiency Heat Pump Features Code * DRY Dehumid Cooler PTAC A Standard Model PMC DigiAIR Cooler PTAC C Corrosion Protection (Seacoast)

hotel’s guestroom PTAC units on cooling energy usage. The test was used to determine whether Fibercare PTAC cleaning service results in lower energy costs. The test was performed on four guestrooms cleaned by the Fibercare cleaning inspector. Fibercare cleaned PTAC units for guestrooms 102, 103, 114, and 121.

2 www.amana-ptac.com MC-DPTAC Energy Efficiencies: With EERs up to 11.7 and COPs up to 3.4, our unit's high efficiencies may qualify you for many of the rebates offered by electrical power companies. Quiet Operation: Our PTAC has been redesigned to be the quietest PTAC we've ever built. The unit's state-of-the-art design and construction provide a quiet environment, allowing .

to the room side of the sleeve to allow for the installation of a 13³ ₄ in. (35 cm) PTAC/ PTHP into an 11¹ ₂ in. (29.2 cm) wall sleeve. 4396600 Lateral duct adapter - attaches to the PTAC/PTHP and provides a transition to direct up to 35% of the total airflow to a secondary room, either left or right of the PTAC/PTHP. Kit

Modern Approaches to Management *Separated Bureaucracy from Classical School. Lawal (2012) 1. Classical School of Management 2. Organic or Neo-Classical School (Human Relations and Behavioural Theories) 3. System and Contingency School 4. Dynamic Engagement Era * Agreed with Stoner et al. (2004) by Identifying New School (No. 4) Robbins and Coulter (2009) 1. Classical Approach 2. Quantitative .