IMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONSEUROPEAN USERS400V 50Hz SUPPLY DETAILS AREINCLUDED WITH ELECTRICALCONTROL BOX. DISREGARD SUPPLYWIRING DETAILS IN THIS MANUALPLEASE READ THE ENTIRE CONTENTS OF THIS MANUAL PRIORTO INSTALLATION AND OPERATION. BY PROCEEDING WITH LIFTINSTALLATION AND OPERATION YOU AGREE THAT YOU FULLYUNDERSTAND AND COMPREHEND THE FULL CONTENTS OF THISMANUAL. FORWARD THIS MANUAL TO ALL OPERATORS. FAILURE TOOPERATE THIS EQUIPMENT AS DIRECTED MAY CAUSE INJURY OR DEATH.Rev. D – February 2021P/N 5900370INSTALLATION AND OPERATION MANUAL12,000/15,000/18,000 LB / 5,443/6,804/8,165 KG CAPACITYTWO-POST Keep this operation manual near themachine at all times. Make sure thatALL USERS read this manual.ORIGINAL INSTRUCTIONS INENGLISH LANGUAGERECEIVINGThe shipment should be thoroughly inspected as soon as itis received. The signed Bill of Lading is acknowledgementby the shipping carrier as receipt of this product as listedin your invoice as being in a good condition of shipment. Ifany of these goods listed on this Bill of Lading are missingor damaged, do not accept goods until the shipping carriermakes a notation on the freight bill of the missing or damaged goods. Do this for your own protection.BE SAFEYour new lift was designed and built with safety in mind.However, your overall safety can be increased with propertraining and thoughtful operation on the part of the operator.DO NOT operate or repair this equipment without readingthis manual and the important safety instructions showninside. Keep this operation manual near the lift at all times.Make sure that ALL USERS read and understand thismanual.1645 Lemonwood Dr.Santa Paula, CA. 93060, USAToll Free 1-800-253-2363Tel: 1-805-933-9970www.bendpak.com1

TWO-POST SURFACE MOUNTEDAUTO AND TRUCK LIFTThis instruction manual has been prepared especially for you.Your new lift is the product of over 40 years of continuous research, testing and development;it is the most technically advanced lift on the market today.READ THIS ENTIRE MANUAL BEFORE INSTALLATION & OPERATION BEGINS.Santa Paula, CA USAwww.bendpak.comRECORD HERE THE LIFT ANDPOWER UNIT INFORMATION WHICH ISLOCATED ON THE SERIAL NUMBERDATA PLATES ON THE LIFT ANDON THE POWER UNITPower Unit Model #Power Unit Date Of Mfg.Power Unit Serial #Max Operating Pressure XPR-12: 2060 psi,XPR-15: 2350 psi, XPR-18: 2580 psi.Model NuMberSerial NuMberlift CapaCitydeSCriptioNVoltage110-240VAC, 50-60 Hz, 1 Ph208-240VAC, 50-60 Hz, 1 Ph380-415VAC, 50-60 Hz, 3 Ph208-440VAC, 50-60 Hz, 3 Phdate of Mfg.DANGER!Disconnect PowerBefore ServicingWArrAnty voiD if DAtA PlAte iS removeDPN 5905950This information is required when calling for parts or warranty issues.PRODUCT WARRANTYOur comprehensive product warranty means more than a commitment to you; it’s also a commitment to the value of yournew BendPak lift. For full warranty details and to register your new lift contact your nearest BendPak dealer or visithttp:/ / www.bendpak.com/support/warranty/What is not covered under this warranty:a. Any failure that results from Purchaser’s abuse, neglect or failure to operate, maintain or service product inaccordance with instructions provided in the owner’s manual(s) supplied.b. Any damage caused by overloading lift beyond rated capacity.c. Items or service normally required to maintain the product, i.e. lubricants, oil, etc.d. Items considered general wear parts such as rubber pads, lifting cables, etc. unless wear or failure is a direct resultof manufacturer defect due to material and/or workmanship.e. Any component damaged in shipment or any failure caused by installing or operating lift under conditions not inaccordance with installation and operation guidelines or damaged by contact with tools or surroundings.f. Motor or pump failure caused by rain, excessive humidity, corrosive environments or other contaminants.g. Rusted components due to improper maintenance or corrosive environments.h. Cosmetic defects that do not interfere with product functionality.i. Damage due to incorrect voltage or improper wiring.j. Any incidental, indirect, or consequential loss, damage or expense that may result from any defect, failure ormalfunction of BendPak Inc. product.k. All electrical components (excluding power unit) are guaranteed for one year against defects in workmanship and/ormaterials when the lift is installed and used according to specifications.NOTE:Every effort has been taken to ensure complete and accurate instructions have been included in this manual, however, possible productupdates, revisions and or changes may have occurred since this printing. BendPak Ranger reserves the right to change specificationswithout incurring any obligation for equipment previously or subsequently sold. Not responsible for typographical errors.2

OWNER’S RESPONSIBILITYIMPORTANT NOTICETo maintain the lift and user safety, the responsibility ofthe owner is to read and follow these instructions:Do not attempt to install this lift if you have never beentrained on basic automotive lift installation procedures.Never attempt to lift components without proper liftingtools such as forklift or cranes. Stay clear of any movingparts that can fall and cause injury. These instructionsmust be followed to ensure proper installation and operation of your lift. Failure to comply with these instructionscan result in serious bodily harm and void product warranty. Manufacturer will assume no liability for loss ordamage of any kind, expressed or implied resulting fromimproper installation or use of this product.tttttPLEASE READ ENTIRE MANUALPRIOR TO INSTALLATIONttDEFINITIONS OFHAZARD LEVELS ttIdentify the hazard levels used in this manual with thefollowing definitions and signal words:Follow all installation and operation instructions.Make sure installation conforms to all applicable Local,State, and Federal Codes, Rules, and Regulations;such as State and Federal OSHA Regulations andElectrical Codes.Carefully check the lift for correct initial function.Read and follow the safety instructions. Keep themreadily available for machine operators.Make certain all operators are properly trained, knowhow to safely and correctly operate the unit, and areproperly supervised.Allow unit operation only with all parts in place andoperating safely.Carefully inspect the unit on a regular basis andperform all maintenance as required.Service and maintain the unit only with authorized orapproved replacement parts.Keep all instructions permanently with the unit andall decals on the unit clean and visible.BEFORE YOU BEGINReceiving:The shipment should be thoroughly inspected as soon as itis received. The signed bill of lading is acknowledgement bythe carrier of receipt in good condition of shipment coveredby your invoice. If any of the goods called for on this bill oflading are shorted or damaged, do not accept them until thecarrier makes a notation on the freight bill of the shorted ordamaged goods. Do this for your own protection.Watch for this symbol: It Means: Immediate hazardswhich will result in severe personal injury or death.NOTIFY THE CARRIER AT ONCE if any hidden loss ordamage is discovered after receipt and request the carrierto make an inspection. If the carrier will not do so, preparea signed statement to the effect that you have notified thecarrier (on a specific date) and that the carrier has failed tocomply with your request.Watch for this symbol: It Means: Hazards or unsafepractices which could result in severe personalinjury or death.IT IS DIFFICULT TO COLLECT FOR LOSS OR DAMAGEAFTER YOU HAVE GIVEN THE CARRIER A CLEARRECEIPT. File your claim with the carrier promptly. Supportyour claim with copies of the bill of lading, freight bill,invoice, and photographs, if available. Our willingness toassist in helping you process your claim does not makeBendPak responsible for collection of claims or replacement of lost or damaged materials.Watch for this symbol: It Means: Hazards or unsafepractices which may result in minor personal injury,product or property damage.3

ContentsTABLE OF CONTENTSPage No.Warranty / Serial Number Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Definitions of Hazard Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Owner’s Responsibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Installer/Operator Agreement/ Protective Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Safety / Warning Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Tools Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Step 1 / Selecting Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Step 2 / Floor Requirements / Concrete Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Assembly View / Description of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Floor Plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Step 3 / Prepare the Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-13Equalizer Cable Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Hose Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Step 4 / Site Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Step 5 / Installing Power Side Post . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16Step 6 / Installing Off Side Post . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Step 7 / Mounting The Overhead Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Step 8 / Mounting The Hydraulic Power Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17-18Step 9 / Installing the Safeties and Safety Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-19Step 10 / Installing Hydraulic Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Step 11 / Routing the Equalizer Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-21Step 12 / Installing Overhead Microswitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21-22Step 13 / Installing Power Unit Hose Assembly and Power Side Safety Cover . . . . . . . . . . . . . . . . . . . . . . . . 22Step 14 / Installing the Lift Arms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23-24Carriage Stop Bolt Installation Warning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Step 15 / Power Unit Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26-28Step 16 / Lift Start Up Final Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Post Installation Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Step 17 / Lubrication. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Step 18 / Bleeding the Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Optional Equipment Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30-32Step 19 / Operation/ Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33-41Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42-45Torque Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46-48Parts Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49-60CE Certificate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61Certificate of Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62Maintenance Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 634

INSTALLER / OPERATORPLEASE READ AND FULLYUNDERSTAND.BY PROCEEDING YOU AGREE TOTHE FOLLOWING:Please read entire manual prior to installation. Do notoperate this machine until you read and understandall the dangers, warnings and cautions in this manual.For additional copies or further information, contact:t I have visually inspected the site where the lift is tobe installed and verified the concrete to be in good condition and free of cracks or other defects. I understand thatinstalling a lift on cracked or defective concrete couldcause lift failure resulting in personal injury or death.BendPak Inc. / Ranger Products1645 Lemonwood Dr.Santa Paula, CA. 930601-805-933-9970www.bendpak.comt I understand that a level floor is required for properinstallation and level lifting.tI understand that I am responsible if my floor is ofquestionable slope and that I will be responsible for allcharges related to pouring a new level concrete slab ifrequired and any charges.INSTALLER / OPERATORPROTECTIVE EQUIPMENTPersonal protective equipment helps makes installation and operation safer, however, it does not take theplace of safe operating practices. Always wear durablework clothing duringany installation and/orservice activity. Shopaprons or shop coatsmay also be worn, however loose fitting clothing should be avoided.Tight fitting leather gloves are recommended to protecttechnician hands when handling parts. Sturdy leather work shoes with steel toes and oil resistant solesshould be used by all service personnel to help preventinjury during typical installation and operation activities.tI understand that Bendpak lifts are supplied withconcrete fasteners meeting the criteria of the AmericanNational Standard “Automotive Lifts - Safety Requirementsfor Construction, Testing, and Validation” ANSI/ALIALCTV-2011, and that I will be responsible for all chargesrelated to any special regional structural and/or seismicanchoring requirements specified by any other agenciesand/or codes such as the Uniform Building Code (UBC)and/or International Building Code (IBC).t I assume full responsibility for the concrete floor andcondition thereof, now or later, where the above equipment model(s) are to be installed. Failure to follow danger,warning, and caution instructions may lead to serious personal injury or death to operator or bystander or damageto property.tI understand that BendPak lifts are designed to beinstalled in indoor locations only. Failure to follow installation instructions may lead to serious personal injury ordeath to operator or bystander or damage to property orlift.Eye protection is essential during installation and operation activities. Safety glasses with side shields, goggles,or face shields are acceptable. Everyday eyeglasses onlyhave impact resistant lenses, they are not safety glasses.Back belts provide support during lifting activities and arealso helpful in providing worker protection. Considerationshould also be given to the use of hearing protection ifservice activity is performed in an enclosed area, or ifnoise levels are high.Failure to follow danger, warning, and cautioninstructions may lead to serious personal injury or deathto operator or bystander or damage to property.THIS SYMBOL POINTS OUT IMPORTANT SAFETY INSTRUCTIONS WHICH IF NOT FOLLOWEDCOULD ENDANGER THE PERSONAL SAFETY AND/OR PROPERTY OR YOURSELF AND OTHERSAND CAN CAUSE PERSONAL INJURY OR DEATH. READ AND FOLLOW ALL INSTRUCTIONS INTHIS MANUAL BEFORE ATTEMPTING TO OPERATE THIS MACHINE.5

INTRODUCTION1. Carefully remove the crating and packing materials.CAUTION! Be careful when cutting steel banding materialas items may become loose and fall, causing injury.2. Check the voltage, phase, and proper amperagerequirements for the motor shown on the motor plate.Wiring should be performed by a certified electrician only.IMPORTANT SAFETY INSTRUCTIONSRead these safety instructions entirely.IMPORTANT NOTICEDo not attempt to install this lift if you have never been trained on basic automotive lift installation procedures.Never attempt to lift components without proper lifting tools such as forklift or cranes.Stay clear of any moving parts that can fall and cause injury. Read and understand all instructions and all safety warnings before operating lift.Care must be taken as burns can occur from touchinghot parts.Do not operate equipment with a damaged cord or if theequipment has been dropped or damaged until it hasbeen examined by a qualified service person.Do not let a cord hang over the edge of the table, bench,or counter or come in contact with hot manifolds or moving fan blades.If an extension cord is necessary, a cord with a currentrating equal to or more than that of the equipment shouldbe used. Cords rated for less current than the equipmentmay overheat. Care should be taken to arrange the cordso that it will not be tripped over or pulled.Always unplug equipment from electrical outlet when notin use. Never use the cord to pull the plug from the outlet.Grasp plug and pull to disconnect.Let equipment cool completely before putting away.Loop cord loosely around equipment when storing.To reduce the risk of fire, do not operate equipment nearopen containers of flammable liquids (gasoline).Adequate ventilation should be provided when workingon operating internal combustion engines.Keep hair, loose clothing, fingers, and all parts of bodyaway from moving parts. Keep feet clear of lift when lowering. Avoid pinch points.DANGER! To reduce the risk of electric shock, donot use on wet surfaces or exposeto rain. The power unit used on thislift contains high voltage. Disconnectpower at the receptacle or at the circuitbreaker switch before performing anyelectrical repairs. Secure plug so thatit cannot be accidentally plugged induring service. or mark circuit breaker switch so that it cannot be accidentally switched on during service. with ANSI/ALI ALIS Safety Requirements for Installationand Service of Automotive Lifts.ALWAYS WEAR SAFETY GLASSES. Everyday eyeglasses only have impact resistant lenses, they are notsafety glasses.Consider work environment. Keep work area clean.Cluttered work areas invite injuries. Keep areas well lit.Guard against electric shock. This lift must be groundedwhile in use to protect operator from electric shock.Never connect the green power cord wire to a live terminal. This is for ground only.Only trained operators should operate this lift. All nontrained personnel should be kept away from the workarea. Never let non-trained personnel come in contactwith, or operate lift.DO NOT override self-closing lift controls.Clear area if vehicle is in danger of falling.ALWAYS make sure the safeties areengaged before attempting to work on ornear a vehicle.WARNING! RISK OF EXPLOSION. Thisequipment has internal arcing or sparking parts which should not be exposed toflammable vapors. This machine should not be locatedin a recessed area or below floor level.MAINTAIN WITH CARE. Keep lift clean for better andsafer performance. Follow manual for proper lubricationand maintenance instructions. Keep control handlesand/or buttons dry, clean and free from grease and oil.Check for damaged parts. Check for alignment of moving parts, breakage of parts or any condition that mayaffect operation of lift. Do not use lift if any component isbroken or damaged.NEVER remove safety related components from the lift.Do not use lift if safety related components are missingor damaged.STAY ALERT. Use common sense and watch what youare doing. Remember, SAFETY FIRST.BendPak requires all operators to read and be familiarSAVE THESE INSTRUCTIONS6

TOOLS REQUIREDttttttt RotaryHammer Drill or Similar3/4” Masonry BitHammer4 Foot LevelOpen-End Wrench Set: SAE/Metric Socket And Ratchet Set: SAE/Metric Hex-Key / Allen Wrench SettttttttLarge Crescent WrenchLarge Pipe WrenchCrow BarChalk Line Medium Flat ScrewdriverTape Measure: 25 Foot MinimumNeedle Nose PliersIMPORTANT NOTICEThese instructions must be followed to ensure proper installation and operation of your lift. Failureto comply with these instructions can result in serious bodily harm and void product warranty.Manufacturer will assume no liability for loss or damage of any kind, expressed or implied resultingfrom improper installation or use of this product.PLEASE READ ENTIRE MANUAL PRIOR TO INSTALLATIONA level floor is suggested for proper use andinstallation and level lifting. If a floor is of questionableslope, consider a survey of the site and/or the possibilityof pouring a new level concrete slab.STEP 1(Selecting Site)Before installing your new lift, check the following.1. LIFT LOCATION: Always use architects plans whenavailable. Check layout dimension against floor planrequirements making sure that adequate space if available.2. OVERHEAD OBSTRUCTIONS: The area where thelift will be located should be free of overhead obstructions such as heaters, building supports, electrical linesetc.3. DEFECTIVE FLOOR: Visually inspect the site wherethe lift is to be installed and check for cracked or defective concrete.t DO NOT install or use this lift on any asphalt surfaceor any surface other than concrete.t DO NOT install or use this lift on expansion seamsor on cracked or defective concrete.t DO NOT install or use this lift on a second / elevatedfloor without first consulting building architect.CONCRETESPECIFICATIONSLIFT MODEL4. OPERATING TEMPERATURE. Operate lift onlybetween temperatures of 41 -104 F.12,000 Lb Models:15,000 Lb Models:18,000 Lb Models:5. Lift is designed for INDOOR INSTALLATION ONLY.Outdoor use is prohibited.CONCRETE REQUIREMENTS6.5” Min. Thickness 3,000 PSI8” Min. Thickness3,000 PSI8” Min. Thickness3,000 PSISTEP 2(Floor Requirements)All models MUST be installed on 3,000 PSI concrete only,conforming to the minimum requirements shown above.New concrete must be adequately cured for at least28 days minimum.This lift must be installed on a solid level concretefloor with no more than 3-degrees of slope. Failureto do so could cause personal injury or death.IMPORTANT NOTE:BendPak lifts are supplied with installation instructions and concrete fasteners meeting the criteria as prescribedby the American National Standard "Automotive Lifts - Safety Requirements for Construction, Testing, andValidation" ANSI/ALI ALCTV-2011. Lift buyers should contact qualified persons regarding any special regional structural and/or seismic anchoring requirements specified by any other agencies and/or codes such as the UniformBuilding Code (UBC) and/or International Building Code (IBC).7

When removing the Lift from shipping angles, pay close attention as the Posts canslide and can cause injury. Prior to removing the Bolts, make sure the Posts are heldsecurely by a Forklift, Shop Crane, or some other heavy lifting device.PARTS INVENTORYBe sure to take a complete inventory of parts prior to beginning installation.DescriptionQtyOverhead AssemblyArm AssembliesFrame Contact PadsFrame Cradle PadsOffside PostPowerside PostPost Extension Weldments (-192 Models ONLY)Hydraulic CylinderParts Box (Packing List Enclosed)Parts Bag (Packed in Part Box)Hydraulic Power Unit14441122111Post ExtensionWeldmentsOverheadAssemblyPowerside PostOffside PostTelescopingScrew PadHydraulicPower UnitStacking PadAdaptersPadsArmAssemblies8

FLOOR 92Lifting Capacity12,000Lbs. / 5443Kg.12,000Lbs. / 5443Kg.12,000Lbs./ 5443Kg.12,000Lbs. / 5443Kg.Max Capacity/ Front Axle6,000 lbs. / 2722 Kg.6,000 lbs. / 2722 Kg.6,000 lbs. / 2722 Kg.6,000 lbs. / 2722 Kg.Max Capacity/ Rear Axle6,000 lbs. / 2722 Kg.6,000 lbs. / 2722 Kg.6,000 lbs. / 2722 Kg.6,000 lbs./ 2722 Kg.170" / 4318 mm. (*)192.7" / 4895 mm.170” / 4318 mm. (*)192.7” / 4895 mm.155" / 3937 mm.155" / 3937 mm.155" / 3937 mm.155" / 3937 mm.MODELA- Height Overall:B -Width Overall165" / 4191 mm. (*)187.7" / 4768 mm.165" / 4191 mm. (*)187.7” / 4768 mm.F -Reach (Front Arm Min.):32" / 813 mm.32” / 813 mm.35-1/2" / 902 mm.35-1/2" / 902 mm.G -Reach (Front Arm Max.):60" / 1524 mm.60” / 1524 mm.71-1/2" / 1819 mm.71-1/2" / 1819 mm.D- Floor to Overhead Switch:H- Reach (Rear Arm Min.):32" / 813 mm.32” / 813 mm.35-1/2" / 902 mm.35-1/2" / 902 mm.I- Reach (Rear Arm Max.):60" / 1524 mm.60” / 1524 mm.71-1/2" / 1819 mm.71-1/2" / 1819 mm.5" / 127 mm.5” / 127 mm.5” / 127 mm.5” / 127 mm.J- Min. Pad Height:K- Rise:69" / 1753 mm.69" / 1753 mm.69" / 1753 mm.69" / 1753 mm.L -Max Lift Height (Pad Only):74" / 1880 mm.74” / 1880 mm.74” / 1880 mm.74” / 1880 mm.M - Max Lift Height (6" Adapter):80" / 2032 mm.80” / 2032 mm.80” / 2032 mm.80” / 2032 mm.Standard Motor(**)220VAC / 60Hz.1Ph.220VAC / 60Hz.1Ph.220VAC / 60Hz.1Ph.220VAC / 60Hz.1Ph.Time of Full Rise:45 Seconds45 Seconds45 Seconds45 Seconds3,000 Lbs." / 1361 Kg.3,000 Lbs." / 1361 Kg.3,000 Lbs." / 1361 Kg.3,000 Lbs." / 1361 Kg.Max Load Per Arm:Emission sound pressure at Operator Position 70 dB(A)* An optional bolt-on top extension for column raises the overhead bar an additional 24”. Must be ordered from factory at time of order.** For CE compliant countries see errata sheet included with control panel.The design, material, and specifications are subject to change without notice.9

FLOOR Lbs. / 6804Kg.15,000Lbs. / 6804Kg.18,000Lbs. / 8165Kg.18,000Lbs. / 8165Kg.Max Capacity/ Front Axle7,500 lbs. / 3402 Kg.7,500 lbs. / 3402 Kg.9,000 lbs. / 4082 Kg.9,000 lbs. / 4082 Kg.Max Capacity/ Rear Axle7,500 lbs. / 3402 Kg.7,500 lbs. / 3402 Kg.9,000 lbs. / 4082 Kg.9,000 lbs. / 4082 Kg.170" / 4318 mm. (*)192.7" / 4895 mm.170” / 4318 mm. (*)192.7” / 4895 mm.155" / 3937 mm.155" / 3937 mm.155" / 3937 mm.155" / 3937 mm.165" / 4191 mm. (*)187.7” / 4768 mm.165" / 4191 mm. (*)187.7” / 4768 mm.MODELLifting CapacityA- Height Overall:B -Width OverallD- Floor to Overhead Switch:F -Reach (Front Arm Min.):39" / 991 mm.39” / 991 mm.39” / 991 mm.39” / 991 mm.G -Reach (Front Arm Max.):60" / 1524 mm.60” / 1524 mm.60” / 1524 mm.60” / 1524 mm.H- Reach (Rear Arm Min.):39" / 991 mm.39” / 991 mm.39” / 991 mm.39” / 991 mm.I- Reach (Rear Arm Max.):60" / 1524 mm.60” / 1524 mm.60” / 1524 mm.60” / 1524 mm.5" / 127 mm.5” / 127 mm.5” / 127 mm.5” / 127 mm.K- Rise:69" / 1753 mm.69" / 1753 mm.69" / 1753 mm.69" / 1753 mm.L -Max Lift Height (Pad Only):74" / 1880 mm.74” / 1880 mm.74” / 1880 mm.74” / 1880 mm.M - Max Lift Height (6" Adapter):80" / 2032 mm.80” / 2032 mm.80” / 2032 mm.80” / 2032 mm.220VAC / 60Hz.1Ph.220VAC / 60Hz.1Ph.220VAC / 60Hz.1Ph.220VAC / 60Hz.1Ph.J- Min. Pad Height:Standard Motor(**)Time of Full Rise:Max Load Per Arm:45 Seconds45 Seconds45 Seconds45 Seconds3,750 Lbs. / 1701 Kg.3,750 Lbs. / 1701 Kg.4,500 Lbs. / 2041 Kg4,500 Lbs. / 2041 KgEmission sound pressure at Operator Position 70 dB(A)* An optional bolt-on top extension for column raises the overhead bar an additional 24”. Must be ordered from factory at time of order.** For CE compliant countries see errata sheet included with control panel.The design, material and specifications are subject to change without notice.10

CLEARANCESXPR-12CL/15CL/18CLAPPROACHLIFT HEIGHT CLEARANCE NOTE: There must be a 1” MIN distance from top of Lift to nearest obstruction.11

STEP 3Fig 3.4(Post Preparation)COMPLETE THE FOLLOWINGPRIOR STANDING UP POSTS.Cable routed upand acrossOver

Mar 22, 2019 · XPR-15CL-192 XPR-18CL XPR-18CL-192. 2 TWO-POST SURFACE MOUNTED AUTO AND TRUCK LIFT This instruction manual has been prepared especially for you. Your new lift is the product of over 40 years of continuous research, testing and development; it i

Related Documents:

1 5245138 xpr-12c lift superstructure 1 w 2 5250045 xpr-12cl/12cl-lwb extended parts box 1 b 3 5215283 xpr-12cl/fdl triple telescoping arm . xpr-12cl-192 production lift ver e 12/15/2015 do not scale drawing scale:1:40 third angle projection 1. see shipping instructions for final packaging 2. all labels to be applied to posts after painting.

This manual is intended for use by experienced technicians fam iliar with similar types of equipment. Specifically, it contains installation information required for the MOTOTRBO XPR 8300/XPR 8380/XPR 8400 Repeater. For information related to the service of the XPR 8300/XPR 8380/XPR 8400 Repeater, refer to the list applicable manuals

1 5600395 xpr-15/18c lift head weldment 1 k 2 5716001 pl-6000/7000, gp/xpr series guide block 8 e 3 5746099 xpr-12c/fd/15/18c Ø25mm long gear shaft 2 d 4 5701052 gp/rtl/xpr arm internal gear stop 2 e 5 5540130 xpr-12c/fd/15/18c lift head spring 2 a 6 5580219 keyring 56mm x 3mm 2 - 7 5505106 spring pin m6 x 50 2 - 8 5540006 snap ring truarc .

1 5600392 xpr-12c lift head weldment 1 k 2 5716001 pl-6000/7000, gp/xpr series guide block 8 e 3 5746099 xpr-12c/fd/15/18c Ø25mm long gear shaft 2 d 4 5701052 gp/rtl/xpr arm internal gear stop 2 e 5 5540130 xpr-12c/fd/15/18c lift head spring 2 a 6 5580219 keyring 56mm x 3mm 2 - 7 5505106 spring pin m6 x 50 2 - 8 5540006 snap ring truarc 5103 .

1 5245044 xpr-10a lift superstructure 1 d 2 5250040 xpr-10as extended parts box 1 d 3 5215286 xpr-10as low profile long arm assembly, r.h. 1 d 4 5215285 xpr-10as low profile long arm assembly, l.h. 1 d 5 5215284 xpr-10as low profile triple telescoping arm assembly 2 d 6 5210269 xpr-10 post

1 5245137 xpr-12fd lift superstructure 1 v 2 5250042 xpr-12fdl/12fdl-lwb parts box 1 b 3 5215376 xpr-12fd top equalizer pulley plate assembly 2 f 4 5215283 xpr-12cl/fdl triple telescoping arm assembly 4 d 5 5905109 warning ali/wl 101 1 - 6 5905131 2 post decal kit, less ali 1 c 7 5905404 max cap danger 12k 1 - 8 5905465 manufacturer label 1 -

dimensions are in mm a 2 1 3 4 6 detail a scale 1 : 12 10 11 9 7 5 8 item no part number description qtyrev 1 5245139 xpr-15/18c lift superstructure 1 w 2 5250046 xpr-15cl extended parts box 1 b

Organizational Behavior 5 Nature of Organization Nature of organization states the motive of the firm. It is the opportunities it provides in the global market. It also defines the employees’ standard; in short, it defines the character of the company by acting as a mirror reflection of the company. We can understand the nature of any firm with its social system, the mutual interest it .