Phantom-X 399C/500C/600C/700C/800CResidential High EfficiencyGas BoilersPHNTM399C, 500C, 600C, 700C, 800C Submittal SheetPHNTM Floor Standing Heating BoilersWholesalerJob NameMechanical ContractorModel NumberGas TypeBTU/hr INPUTBTU/hr OUTPUTVenting ApplicationQuantity:VELOCITY LOGO CMYK COLORSStandard FeaturesOptional Equipment ASME Constructed Stainless Steel Water Tube Heat Exchanger Sage Zone Panel 50 psi Relief Valve Condensate Neutralizer 210F Maximum Operating Supply Temperature Header Sensor Kit - Required for multiple boiler systems Thermal Efficiency up to 97.0% RJ45 Cable Splitter Fully Modulating Burner System with 5:1 Turndown Ratio LWCO Kit Vent Adapter Allows For 4” CPVC/PVC or Single Wall Polypropylene Manual Reset High Limitor Stainless Venting CSD-1 kit for 399C includes manual reset high limit and immersionwell.Note: See Installation Manual for a List of Approved Vent Systems, CSD-1 kit for 500C thru 800C includes high and low gas pressureswitches (manual reset).Vent Length Limitations, and Other Installation Requirements Polypropylene Condensate Trap Boiler, System and Domestic Hot Water Pump Output Terminals Tight Clearances to Combustible Material Field Convertible to LP Gas Stackable for Floor Space Savings Microprocessor Based Honeywell Sola Control System with Touch ScreenSpecial Job Notes:User Interface Consisting of:o Direct Spark Ignition Systemo Supply, Return, Flue, Outdoor Sensors and Flow Switcho Lead/Lag and Selectable DHW Priorityo Warm Weather Shutdowno Pump Exerciseo Central Heating System Freeze Protectiono Energy Management System (EMS) 4-20mA Interfaceo Plug & Play Multiple Boiler Peer-Peer Communication NetworkConnections For Up to 8 Multiple Boiler Installationso Remote Firing Rate and External Limit Terminal Contactso Terminal Contacts for Optional Header Sensor 9 Year Limited Heat Exchanger Warranty, 1 Year Warranty On Parts05-2019 Rev D1 of 7

2 of 7112 2 "158"152"4" PVC COMBUSTIONAIR CONNECTOR4" CPVC/PP/SSVENT CONNECTOR92 16 "ACCESS PANEL'A''K'CONDENSATE DRAIN'H' 1-1/2" FPTRETURN TAPPINGACCESS PANELVelocity Boiler Works - 3633 I Street - Philadelphia, PA 19134 - 215-535-8900v - 215-535-9736fx'E'ACCESS PANEL3/4" FPTRELIEF/DRAINTAPPING'D'137 16 "'C''B'LOW VOLTAGEKNOCKOUTS(24 VOLTS)'J' 1-1/2" FPTSUPPLY TAPPINGACCESS PANEL'G'GAS VALVE INLETLINE VOLTAGEKNOCKOUTS(120 VOLTS)ACCESS PANEL55 16 "517 16 "114"1116 "132 2 "143 2 "716 8 "PHNTM399Cwww.velocityboilerworks.com05-2019 Rev D

115 2 "188"152"4" PVC COMBUSTIONAIR CONNECTOR4" CPVC/PP/SSVENT CONNECTOR92 16 "ACCESS PANEL3 of 758 16 "ACCESS PANEL'A'ACCESS PANEL'K'CONDENSATE DRAIN'J' 2" MPTSUPPLY TAPPING'H' 2" MPTRETURN TAPPINGACCESS PANEL'D''E''C''G'GAS VALVE INLETLINE VOLTAGEKNOCKOUTS(120 VOLTS)LOW VOLTAGEKNOCKOUTS(24 VOLTS)358"ACCESS PANEL135 16 "312 8 "520 16 "114"1116 "716 8 "PHNTM500CVelocity Boiler Works - 3633 I Street - Philadelphia, PA 19134 - 215-535-8900v - 215-535-9736fxwww.velocityboilerworks.com05-2019 Rev D

915 16 "Velocity Boiler Works - 3633 I Street - Philadelphia, PA 19134 - 215-535-8900v - 215-535-9736fx4 of 717 16 "188"4" PVC COMBUSTIONAIR CONNECTOR6" CPVC/PP/SSVENT CONNECTOR92 16 "ACCESS PANEL58 16 "ACCESS PANEL'A'ACCESS PANEL'K'CONDENSATE DRAIN'H' 2" MPTRETURN TAPPINGACCESS PANEL'D''E''C''G'GAS VALVE INLET'J' 2" MPTSUPPLY TAPPINGLINE VOLTAGEKNOCKOUTS(120 VOLTS)768"LOW VOLTAGEKNOCKOUTS(24 VOLTS)ACCESS PANEL510 16 "520 16 "135 16 "114"1116 "716 8 "PHNTM600C, PHNTM700C, PHNTM800Cwww.velocityboilerworks.com05-2019 Rev D

Ratings for Phantom X Series Gas-Fired BoilersInput (MBH)ModelNumberGross Output Net Ratings Water 1(MBH)(MBH)ThermalEfficiency (%)CombustionEfficiency 094.0Ratings shown are for installations at sea level and elevations up to 2000 ft. at minimum vent length. For elevations above 2000ft., see Appendix A Instructions in manual for High Altitude Installations above 2000 ft.1Net AHRI Water Ratings based on allowance of 1.15. Consult manufacturer before selecting boiler for installations havingunusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.Boiler ModelPHNTM399CPHNTM500C PHNTM600C PHNTM700C PHNTM800C2Altitude (ft. above sea level) 10-10,1000-10,1000-10,1000-10,10030-6,0004Shipped for Natural Gas, Field Shipped for Natural Gas or Shipped for LP GasFuelConverted for LP Gas(no Field Conversion)Max. Allowable Water Temperature ( F)210210210210210Max. Allowable Working Pressure (psi)160160160160160Factory Supplied Safety Relief Valve (psi)*5050606060Boiler Water Volume (gal.)3.44.35.45.46.2Heat Transfer Area (sq. ft.)41.858.176.276.287.0Approx. Shipping Weight (lb.)3163684584585001Follow Instructions for High Altitude Installations above 2000 ft2PHNTM500C LP cannot be installed above 6,000 ft3PHNTM700C LP cannot be installed above 7,800 ft4PHNTM800C natural gas cannot be installed above 6,000 ft. PHNTM800C LP can be installed up to 10,100 ftSpecificationDimensionA - Inch)mm(B - Inch)mm(C - Inch)mm(D - Inch)mm(E - Inch)mm(Gas Inlet G - InchReturn H - InchSupply J - InchPP Condensate Drain K - InchPVC Combustion Air Connector - InchCPVC/PP/SS Vent Connector - Inch)(mmBoiler /8)719()784()784()FPT( 3/4)FPT( 1FPT 1-1/2MPT 2FPT 1-1/2MPT 2PVC Compression Coupling 0( 6Venting Note: Sizes noted are for two pipe CPVC/PVC & certain specified two pipe polypropylene and certain specified stainlesssteel vent systems. Concentric vent terminals are not permitted. See installation manual for venting option details.Velocity Boiler Works - 3633 I Street - Philadelphia, PA 19134 - 215-535-8900v - 215-535-9736fxwww.velocityboilerworks.com05-2019 Rev D5 of 7

Flow Range Requirement Through BoilerSupplyReturnBoiler Model Connection TM700CPHNTM800C1-1/222221-1/22222DT 35 FΔT 30 FΔT 25 FΔT 20 ossLossLossFlow (GPM)(GPM)(GPM)Flow 50.77.860.810.876.016.1Notes: Required Flow Output*1000/(500*ΔT), where flow rate is in GPM, output is in MBH, and ΔT is in FOutputs for specific boiler models are provided in Ratings Table on page 5. See also tables on page 7 for near boiler piping sizing.Using boiler antifreeze will result in increased fluid density and may require larger circulators.Velocity Boiler Works - 3633 I Street - Philadelphia, PA 19134 - 215-535-8900v - 215-535-9736fxwww.velocityboilerworks.com05-2019 Rev D6 of 7

Velocity Boiler Works - 3633 I Street - Philadelphia, PA 19134 - 215-535-8900v - 215-535-9736fx7 of 7www.velocityboilerworks.com05-2019 Rev ler &PipingCirculatorHead LossModel(ft.)DT 35 r &PipingHead Loss(ft.)DT 30 -652400-652400-652400-602400-60Boiler &PipingCirculatorHead LossModel(ft.)DT 25 22PHNTM800C2PHNTM600CPHNTM700C2PHNTM500C2 pplyNear& ReturnBoilerBoiler ModelConnection Pipe 9.6UPS43-44FC,Spd. 345.932.3UPS43-44FC,Spd. 2UPS43-100F,Spd. 225.1CirculatorModelDT 30 F8.59.47.27.58.4Boiler &FlowPiping(GPM) Head Loss(ft.)UP26-64FDT 35 FBoiler &PipingHead Loss(ft.)UPS43-100F,Spd. 3UPS43-100F,Spd. 3UPS43-100F,Spd. 0.211.812.99.910.311.5UP-50-60F,Spd. 3UPS50-60F,Spd. 3UPS50-60F,Spd. d. 2UPS43-100F,Spd. 216.9Flow(GPM)CirculatorModelDT 20 FBoiler &PipingHead Loss(ft.)DT 25 FBoiler &FlowPiping(GPM) Head Loss(ft.)UPS50-80/2,Spd. 3UP50-80/2,Spd. 3UPS40-80/2,Spd.3UP50-60F,Spd. 3UPS43-100F,Spd. r &PipingCirculatorHead LossModel(ft.)DT 20 FRecommended Grundfos Circulators for 50 Equivalent ft. Near Boiler Piping [Approximately 20 ft. Straight Pipe, (4) 90 Elbows,and (2) Full Port Ball Near Boiler& ReturnBoiler ModelPipe SizeConnection(in.)(in.)Recommended Taco Circulators for 50 ft. Equivalent ft. Near Boiler Piping [Approximately 20 ft. Straight Pipe, (4) 90 Elbows,and (2) Full Port Ball Valves]

UPS43-100F, Spd.2 50.7 8.5 UPS43-100F, Spd. 3 60.8 11.8 UP-50-60F, Spd. 3 76.0 17.6 UPS50-80/2, Spd. 3 Recommended Taco Circulators for 50 ft. Equivalent ft. Near Boiler Piping [Approximately 20 ft. Straight Pipe, (4) 90

Related Documents:

Oil/gas boilers and low pressure hot water boilers up to 22 MW Commercial oil and gas _ Wl l a mounted gas boilers up to 150 kW _ Floorstanding oil & gas boilers up to 2000 kW _ Low pressure hot water boilers up to 22 MW Viessmann Limited Hortonwood 30, Telford Shropshire, TF1 7YP Tel: 01952 675000 Fax: 01952 675040 www.viessmann.co.uk 9443 324 .

Indian Boiler Regulation [3] The Indian Boilers Act was enacted to consolidate and amend the law relating to steam boilers. Indian Boilers Regulation (IBR) was created in exercise of the powers con-ferred by section 28 & 29 of the Indian Boilers Act. IBR Steam Boilers means any

Firetube Boilers Model CB Boilers 09-04 Table A2-26 shows regulated gas pressure requirements for Model CB Boilers with standard or FM gas trains. Table A2-27 shows regulated gas pressure requirements for Model CB Boilers with IRI gas trains. Table A2-28 and A2-29 show regulated gas pressure with over and undersized gas trains.

Wall-mounted condensing boilers Installer’s and User’s Instructions UNI EN ISO 9001 CERTIFICAZIONE DEI SISTEMI QUALITA' DELLE AZIENDE HT BAXI S.p.A., one of the leading European enterprises to produce central heating and hot water devices for domestic use (wall-mounted gas-operated boilers, floor-standing boilers and electrical water-heaters) has obtained the CSQ certificate of .

EXCERPTS FROM: ASME BOILER AND PRESSURE VESSEL CODE SECTION I POWER BOILERS 2004 EDITION INTRODUCTION This Code covers rules for construction of power boilers,1 electric boilers,2 miniature boilers,3 and high temperature water boilers4 to be used in stationary service and includes those power boilers used in locomotive, portable, and .

UNIT – 2 Steam Boilers and Draft Classification of steam boilers, Comparison between fire and water tube boilers, Essentials of a good . Stationary boilers are used for power plant-steam, for central station utility power plants, for plant process steam etc. (i.e. on Land)

Boilers under The Boilers Act, 1923” service from the Directorate of Factories & Boilers, Labour & ESI Department, Govt. of Odisha. General Instructions Based on the geographical location of the factory and the no. of employees proposed to be employed, and the application will be routed to the designated Assistant Director of Factories & .

American Revolution Lapbook Cut out as one piece. You will first fold in the When Where side flap and then fold like an accordion. You will attach the back of the Turnaround square to the lapbook and the Valley Forge square will be the cover. Write in when the troops were at Valley Forge and where Valley Forge is located. Write in what hardships the Continental army faced and how things got .