BDA BroadbandDrop AmplifierFEATURES 1 GHz Gallium Arsenide Technology 2.5 dB Noise Figure Patented Auto‐Seize FFT F‐Connector One, Two, or Four Port Versions Two‐Way Capable LED Power Verification Local or Remote Powering Environmentally Hardened Design 6 kV Surge Resistant Current limited power supplyPRODUCT OVERVIEWThe BDA Broadband Telecommunications Drop Amplifier is a two‐way 1 GHz amplifier designed for customer premise amplification.These amplifiers can be used to compensate for long drops and excessive splitting losses. Each BDA is housed within a robustaluminum die cast housing and utilizes the ARRIS FFT Auto‐Seize F‐Connector for maximum reliability.Gallium Arsenide TechnologyThe BDA amplifier uses advanced Gallium Arsenide technology for improved distortion and noise performance. This technologyprovides improved distortion performance for both CTB and CSO distortions. Compared to silicon based amplifiers, GaAs distortionperformance remains linear at significantly higher output levels.Ask us about the complete Access Technologies Solutions portfolio:Fiber‐DeepDOCSIS 3.1Node SegmentationRF Amps‐BDAHPON /RFoGFTTx

BDA Broadband Drop AmplifierTwo‐Way CapableThe BDA amplifier has built‐in diplex filters for two‐way operation. A passive return path is provided for return path continuity andenables the use of multiple broadband devices such as set‐top terminals and cable modems. An active return path is provided forthe BDA‐**‐*‐AR‐* models to overcome external splitting losses. The BDA is available with return split (42/52 MHz) diplex filters inpassive return models, and traditional K‐split (42/54 MHz) and N‐split (85/104 MHz) diplex filters for the active return models.Please contact your ARRIS Account Representative for specific details.Local or Remote PoweringThe BDA can be powered locally or remotely via a UL‐approved AC to DC power supply. A power inserter (BDP‐100/PI) is availableas an accessory item for remote powering applications. All BDA models include a 110/220 VAC power supply for ready poweringduring installation.Surge TolerantThe BDA amplifier is designed to meet the 6 kV IEEE C62.41‐1991 Category B‐3 Combination Wave at the input port. It is alsodesigned to meet both 6 kV IEEE C62.41‐1991 Category A‐3 Ring Wave and 1 kV Combination Wave surge for all output ports,power supply transformer port, and power inserter ports. This surge tolerance enhances system reliability.Indoor or Outdoor ApplicationsA weather seal and protective coating are provided so that the BDA amplifier may be used for indoor or outdoor applications.RELATED PRODUCTSCHP ChassisOptical Patch CordsPower SuppliesOptical PassivesControl ModuleInstallation ServicesAsk us about the complete Access Technologies Solutions portfolio:Fiber‐DeepDOCSIS 3.1Node SegmentationRF Amps‐BDAHPON /RFoGFTTx

BDA Broadband Drop AmplifierBDA‐42‐*‐PR‐R ‐ SPECIFICATIONSForward SpecificationsPassband: 52‐1000 MHzSpecificationBDA‐42‐1‐PR‐RFreq. (MHz)Gain R‐RMinNomMinNomMinNom13.215.010.111.06.27.0Input Return Loss (dB)52‐1000182018201820Output Return Loss (dB)52‐1000182018201820Output Port to Port Isolation (dB)52‐1000——24272527Flatness, (dB max)52‐1000 0.8Distortions (dB min)Channel Loading Output Levels77 Channels (550 MHz)272319110 Channels (750 MHz)242016CTB (dBc min)70XMOD (dB min)70CSO (dBc min)60Noise Figure (dB max)2.53.03.0RFI Shielding (dB min)100Hum Modulation (dBc)70Return SpecificationsPassband: 5‐42 MHzSpecificationMaxNomMaxNomMaxNomInsertion Loss (dB)5‐421.71.05.04.48.58.0Input Return Loss (dB)5‐42202220222022Output Return Loss (dB)5‐42202220222022Output Port to Port Isolation (dB)5‐42——23272527BDAPS‐12‐US‐E ‐ SPECIFICATIONSParameterSpecificationCommentsInput and Output ConnectorsF‐ConnectorSCTE compliant, FFT P‐series auto‐seizeNominal Impedance75 ΩAC Power Supply Voltage Input110/220 VAC nominalAmplifier DC Input Voltage12 VDC nominalPower Consumption3WSurge WithstandBDA input port: 6 kV ‐ IEEE C62.41‐1991 Cat. B‐3 Combination Wave, 3 kABDA output port(s): IEEE C62.41‐1991 Cat. A‐3 Ring Wave, 6 kV, 200 A and 1 kV Combination Wave (10x)Housing Dimensions20 x 45 x 56 mmWeight1.1 lb (0.5 kg)MaximumHeight x Width x DepthEnvironmental SpecificationsPressure Seal15 psiOperating Temperature‐40 C to 60 C (‐40 F to 140 F)Ask us about the complete Access Technologies Solutions portfolio:Fiber‐DeepDOCSIS 3.1Node SegmentationRF Amps‐BDAHPON /RFoGFTTx

BDA Broadband Drop AmplifierBDA‐42‐*‐AR‐R ‐ SPECIFICATIONSForward SpecificationsPassband: 54‐1000 MHzSpecificationBDA‐42‐1‐AR‐RFreq. (MHz)Gain 15.06.77.5Input Return Loss (dB)54‐100018201820Output Return Loss (dB)54‐100018201820Output Port to Port Isolation (dB)54‐1000——2527Flatness, (dB max)54‐1000 1.0Distortions (dB min)Channel Loading Output Levels77 Channels (550 MHz)2719110 Channels (750 MHz)2416CTB (dBc min)75XMOD (dB min)75CSO (dBc min)62Noise Figure (dB max)3.53.5RFI Shielding (dB min)100Hum Modulation (dBc)75Return SpecificationsPassband: 5‐42 MHzSpecificationMinNomMinNomGain (dB)5‐429.210.01.22.5Input Return Loss (dB)5‐4220221822Output Return Loss (dB)5‐4220221822Output Port to Port Isolation (dB)5‐42——2527BDAPS‐18‐US‐E ‐ SPECIFICATIONSParameterSpecificationCommentsInput and Output ConnectorsF‐ConnectorSCTE Compliant, FFT P‐series auto‐seizeNominal Impedance75 ΩAC Power Supply Voltage Input110/220 VAC nominalAmplifier DC Input Voltage18 VDC NominalPower Consumption9WSurge ProtectionInput port: 6 kV ‐ IEEE C62.41‐1991 Cat. B‐3 Combination Wave, 3 kAOutput port(s): IEEE C62.41‐1991 Cat. A‐3 Ring Wave, 6 kV, 200 A and 1 kV Combination Wave (10x)Dimension20 x 45 x 56 mmWeight1.1 lb (0.5 kg)MaximumEnvironmental SpecificationsPressure Seal15 psiOperating Temperature‐40 C to 60 C (‐40 F to 140 F)Ask us about the complete Access Technologies Solutions portfolio:Fiber‐DeepDOCSIS 3.1Node SegmentationRF Amps‐BDAHPON /RFoGFTTx

BDA Broadband Drop AmplifierBDA‐85‐*‐AR‐R ‐ SPECIFICATIONSForward SpecificationsPassband: 104‐1000 MHzSpecificationBDA‐85‐1‐AR‐RFreq. (MHz)Gain 615.06.77.5Input Return Loss (dB)104‐100018201820Output Return Loss (dB)104‐100018201820Output Port to Port Isolation (dB)104‐1000——2527Flatness, (dB max)104‐1000 1.0Distortions (dB min)Channel Loading Output Levels77 Channels (550 MHz)27110 Channels (750 MHz)241916CTB (dBc min)75XMOD (dB min)75CSO (dBc min)62Noise Figure (dB max)3.53.5RFI Shielding (dB min)100Hum Modulation (dBc)75Return SpecificationsPassband: 5‐85 MHzSpecificationMinNomMinNomGain (dB)5‐859.210.01.02.5Input Return Loss (dB)5‐8520221820Output Return Loss (dB)5‐8520221820Output Port to Port Isolation (dB)5‐85——2527BDAPS‐18‐US‐E ‐ SPECIFICATIONSParameterSpecificationCommentsInput and Output ConnectorsF‐ConnectorSCTE Compliant, FFT P‐series auto‐seizeNominal Impedance75 ΩAC Power Supply Voltage Input110/220 VAC nominalAmplifier DC Input Voltage18 VDC NominalPower Consumption9WSurge ProtectionInput port: 6 kV ‐ IEEE C62.41‐1991 Cat. B‐3 Combination Wave, 3 kAOutput port(s): IEEE C62.41‐1991 Cat. A‐3 Ring Wave, 6 kV, 200 A and 1 kV Combination Wave (10x)Dimension20 x 45 x 56 mmWeight1.1 lb (0.5 kg)MaximumEnvironmental SpecificationsPressure Seal15 psiOperating Temperature‐40 C to 60 C (‐40 F to 140 F)Ask us about the complete Access Technologies Solutions portfolio:Fiber‐DeepDOCSIS 3.1Node SegmentationRF Amps‐BDAHPON /RFoGFTTx

BDA Broadband Drop AmplifierFigure 2: BDA Remote Powering ConfigurationFigure 1: BDA Local Powering ConfigurationsORDERING INFORMATIONModel NamePart 1BDA‐42‐1‐PS‐PR‐R ‐ 1GHz BDA, 42/54, With 110/220V PS, 1 Output, Passive Return, F‐connector, 2‐4‐PS‐PR‐R ‐ 1GHz BDA, 42/54, With 110/220V PS, 4 Output, Passive Return, F‐connector, 2‐2‐PS‐PR‐R ‐ 1GHz BDA, 42/54, With 110/220V PS, 2 Output, Passive Return, F‐connector, 5‐1‐PS‐AR‐R ‐ 1GHz BDA, 85/104MHz, With 110/220V PS, 1 Output, Active Return, F‐connector, 5‐4‐PS‐AR‐R ‐ 1GHz BDA, 85/104MHz, With 110/220V PS, 4 Output, Active Return, F‐connector, 2‐1‐PS‐AR‐R ‐ 1GHz BDA, 42/54MHz, With 110/220V PS, 1 Output, Active Return, F‐connector, 2‐4‐PS‐AR‐R ‐ 1GHz BDA, 42/54MHz, With 110/220V PS, 4 Output, Active Return, F‐connector, S‐E ‐ 110/220 Volt U.S. Style 18V BDA Power Supply without Cable, 2‐US‐E ‐ 110/220 Volt U.S. Style 12V BDA Power Supply without Cable, EfficientBDP‐100/PI463653‐001‐00Power Inserter, 1 GHzNote: Specifications are subject to change without notice.Customer CareCopyright Statement: ARRIS Enterprises, LLC, 2016. All rights reserved. No part of this publication may bereproduced in any form or by any means or used to make any derivative work (such as translation,transformation, or adaptation) without written permission from ARRIS Enterprises, LLC (“ARRIS”). ARRISContact Customer Care for product information and sales: United States: 866‐36‐ARRIS International: 1‐678‐473‐5656reserves the right to revise this publication and to make changes in content from time to time withoutobligation on the part of ARRIS to provide notification of such revision or change. ARRIS and the ARRIS logoare all registered trademarks of ARRIS Enterprises, LLC. Other trademarks and trade names may be used inthis document to refer to either the entities claiming the marks and the names of their products. ARRISdisclaims proprietary interest in the marks and names of others. The capabilities, system requirementsand/or compatibility with third‐party products described herein are subject to change without notice.(rev 03-2016)BDA DS 03MAR16Ask us about the complete Access Technologies Solutions portfolio:Fiber‐DeepDOCSIS 3.1Node SegmentationRF Amps‐BDAHPON /RFoGFTTx

BDA Broadband Drop Amplifier The BDA Broadband Telecommunications Drop Amplifier is a two‐way 1 GHz amplifier designed for customer premise amplification. These amplifiers can be used to compensate for long drops and excessive splitting losses. Each BDA is housed within a robust

Related Documents:

Home Broadband Touchstone, Surfboard, NVG w/o ECO, Extenders, HAv3, Plume, Assia homebroadbandsupport@commscope.com HomeAssure Support ECO, Edge, Andromeda homeassuresupport@commscope.com Home Media Devices IP STB and QAM STB (except those supported by LTTS) homemediadevicesupport@commscope.com Home Media Software

The Business Data Architecture (BDA) has been updated and released at intervals and this is the seventh BDA release. Each release is considered a “cut” of the continuingly evolving data architecture. Up until BDA version six (the sixth “cut”), a new version was createdwhen significant changes had been made to the Business Data Architecture to warrant a new “cut”. BDA version six .

MODULATORS AND 1-F AMPLIFIERS . Mobile Modulator-25-Watt Modulator-60-MC 1-F Amplifier-25-Watt Modulator-100-Watt Modulator-I2.5-MC 1-F Amplifier -5.5-MC 1-F Amplifier-JO-MC 1-F Amplifier SECTION 5 MISCELLANEOUS CIRCUITS Signaling System-Mobile Public-Address System-5-Watt 150-MC Amplifier-Squelch Amplifier-I60-MC Power Amplifier-Auto

E80 Lecture 4.2: Basic Electrical Measurements Agenda: Operational Amplifier o Recap: Non-inverting amplifier and unity gain buffer o Inverting amplifier (multiplication) o Summing amplifier (add and subtract) o Differentiator and integrator o Difference amplifier o Instrumentation amplifier o Transimpedance amplifier o Active filters 2

BT Broadband Desktop Help (PCs only) is included with your BT Total Broadband service. It's a tool that identifies problems with your broadband, email or wireless connection. Once it's installed on your computer, it continually checks your broadband connection. If there's a problem, BT Broadband Desktop Help automatically pops up to help .

commscope.com 4 Precise production control and rigorous testing ensure a trouble-free cable The superior performance of CommScope fiber-optic cables derives as mu

Remote electrical downtilt systems from CommScope CommScope’s highly precise, yet flexible, remote electrical tilt (RET) solutions enable you to optimize, control and maintain the perfect antenna beam position from anywhere—without costly site visits, tower climbs or network downtime. Respond quickly to changing traffic needs

Army Reserve Psychological Health Program Stacey Feig, Team Leader Army Reserve Staff - Fort Belvoir Office: 703-806-6905 Cell: 703-254-8246 stacey.a.feig.ctr@mail.mil The program offers counseling referrals for soldiers and family members, Command consultation, and Traumatic Event Management.