2300-d Dims

3y ago
80 Views
9 Downloads
238.27 KB
5 Pages
Last View : 5d ago
Last Download : 3m ago
Upload by : Sabrina Baez
Transcription

Series 2300DIRECT DRIVE TURBO BLOWERSDimensions 2300-DMarch 2010EK–Rad.No. 2S–Inlet Nominal Pipe SizeNo. 3R–dia.3 holes 6 holesIFT‡Base planfor housingsHCL InletG KBase planfor housingsHL /16111 through 38Q 1/1641, 44, 47L 1/16HC 1/16L 1/16L 1/16SWV PBThreadedG*ZC 1/16DU‡C 1/16No. 1JFF KP No. 4Discharge P109/16for No. 11 HousingA– Discharge Nominal Pipe Size-female pipe thread for 6" and smaller,unthreaded pipe (SW) for 8" and larger.DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC.IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL.All dimensions are in inches. Dimensions shown apply only to blowers with T-frame motors. Consult Fives North American for dimensions ofblowers with other motors.BlowerDesignation 2304-11/1- .3D2304-44/1- 10DABCD2§ 15/16 105/8 137/1618† 115/8 51/2 321/16EFGHJKLPQR S T‡U‡VZ* F KG K73/16 99/16§ 83/4 59/16 81/2 723/8 — 3/4 3 4 1611/16 3/4 — 169/16§ 153/428425/16† 311/2 187/8 34 277/16 233/4 93/4 177/8 1 16 33/4 321/8 311/16 — 693/4† 5815/162308-11/3-T.5D2308-14/1- .5D2308-14/1- .75D2308-14/1- 1D2308-17/1- 1D2308-17/1- 1.5D2308-24/1- 4121/4121/4121/4133/42308-24/1- 3D2308-31/1- 5D2308-31/1- 7.5dD2308-31/1- 7.5tD2308-21/1- 10D2308-44/1- /82308-44/1- 15D2308-44/1- 20D2308-44/1- 25D2308-44/1- 30D2308-47/1- 40D2308-47/1- 16 81/283/8 111/283/8 111/283/8 111/281/4 111/281/4 /8 51/2 35/851/2 35/851/2 35/851/2 451/2 7/8147/8147/8193/4277/16663/863/8771/4233/451/4 —67/8 —67/8 —67/8 —89/16 —93/4 313177/8177/8177/8177/8223/4223/444444441813/16 1/2/161813/16 /43333346/4/43/43/43/411111113333 Explanation of designation: 2304-11/1- .3D means Series 2300, 4 osi pressure, inner housing no. 11, 1 stage, 1/3 hp motor, direct drive.dWith drip-proof motor, if dimensions are different from TEFC.tWith TEFC motor, if dimensions are different from drip-proof.* Z Motor overhang for TEFC motors. There is no overhang for drip-proof motors, except 2320-33/1- 40D and 2324-33/1- 40D which overhang 1/2".‡ Listed T and U dimensions are for SW inlet. For threaded inlet where S 3", T 13/4"; S 4", T 17/8"; S 6", T 5". If S is greater than 6", threadedinlet is not available.† SW discharge (unthreaded pipe) is included in F. Discharge CL is 109 16" from farthest base hole, for inner housing no. 11.§ Female pipe thread. If SW discharge (unthreaded pipe) is specified, add 31/4" to F.5 holes when No. 4 discharge is furnished. When #4 discharge position is specified, all blowers except those in discharge position group A, B, or C, require a modification of blower base(reference Bulletin 2300).

EK–Rad.No. 2S–Inlet Nominal Pipe SizeNo. 3R–dia.3 holes 6 holesIFT‡Base planfor housingsHC 1/16Base planfor housingsHL /16111 through 38CL InletG KQ 1/16L 1/1641, 44, 47L 1/16HL 1/16V PBSWThreadedG*ZC 1/16DU‡C 1/16No. 1JFF KP No. 4Discharge P10 /16for No. 11 Housing9A– Discharge Nominal Pipe Size-female pipe thread for 6" and smaller,unthreaded pipe (SW) for 8" and larger.All dimensions are in inches. Dimensions shown apply only to blowers with T-frame motors.Consult Fives North American for dimensions of blowers with other motor dimensions.BlowerDesignation ABDEFGHJKU‡VZ*F KG K2310-11/4-T.5D2310-19/1- .75D2310-19/1- 1D2310-19/1- 1.5D2310-19/1- 2D2310-26/1- 3D2310-26/1- 5D2310-35/1- 7.5D2310-21/1- 10D2310-47/1- 40D2310-47/1- 3/16313/1623/8 —63/4 45/16 —63/4 45/16 —63/4 45/16 —63/4 45/16 —757/16 —757/16 —81/2 615/16 —71/4 89/16 —267/8 13223/4267/8 12-11/4-T.5D2312-19/1- 1D2312-19/1- 1.5D2312-19/1- 2D2312-26/1- 3D2312-26/1- 5D2312-35/1- 7.5D2312-35/1- 10D2312-21/1- 15dD2312-21/1- 15tD2312-41/1- 20D2312-41/1- 25D2312-41/1- 30D2312-47/1- 40D2312-41/1- 40D2312-47/1- 3/162316-14/2- 1D2316-14/2- 1.5D2316-17/2- 1.5D2316-17/2- 2D2316-19/1- 2D2316-19/1- 3D2316-26/1- 3D2316-17/2- 3D2316-24/2- 3D2316-28/1- 5D2316-24/2- 5D2316-26/1- 5D2316-31/2- 7.5dD2316-31/2- 7.5tD2316-28/1- 7.5D2316-26/1- 7.5dD2316-26/1- 7.5tD2316-31/2- 10D2316-35/1- ensions 2300-DCLPQ —45/16 —45/16 —45/16 —57/16 —57/16 —615/16 —615/16 —89/16 —91/16 —113/8 193/4113/8 193/4113/8 193/413223/4113/8 �———————————————R S T‡3333334131313Page 2

BlowerDesignation CDEFGHJU‡VZ*F KG D10† 37/810† 37/810† 41/1610† 41/1610† 37/812† 232325371/2193/471/4 89/16 —193/481/2 91/16 —1813/16 81/2 615/16 —1813/16 91/2 83/16 —193/481/2 91/16 —3311/16 297/8 113/8 1/4221/2221/2221/2/16/1613/1631 /1631 ��————3/4 8 4/4 8 43/4 8 43/4 8 43/4 10 43/4 10 51/4451/42320-35/1- 15dD2320-35/1- 15tD2320-21/1- 20D2320-41/1- 25D2320-33/1- 25D2320-33/1- 30D8† 41/168† 41/1610† 37/812† 125/1612† 57/1612† 325371/234341813/16 81/2 615/16 —1813/16 91/2 83/16 —193/481/2 91/16 —3311/16 297/8 113/8 193/4251/2 10111/8 —251/2 10111/8 1/1660602320-41/1- 30D2320-33/1- 40dD2320-33/1- 40tD2320-41/1- 40D2320-33/1- 50D2320-41/1- 50D2320-41/1- †7111/1660607111/16607111/167111/162324-14/3- 1.5D2324-14/3- 2D2324-19/2- 3D2324-26/2- 5D2324-26/2- 7.5dD2324-26/2- 7.5tD2324-35/2- 10D2324-35/2- 67/8267/8/16/1613/1631 /1631 - 15tD2324-21/1- 20D2324-33/1- 25D2324-33/1- 30D2324-33/1- 40dD2324-33/1- 40tD2324-33/1- 50D2324-33/1- 893/475 /16 91/257/16 91/257/16 91/257/16 1/431/431/431/431/431/425/1623/1621/433/41/223/414 †451/4451/4451/4451/4451/460602332-19/3- 3D2332-19/3- 5D2332-28/2- 7.5D2332-28/2- 10D2332-28/2- 15dD2332-28/2- 15tD2332-21/2- 20D2332-21/2- 25dD2332-21/2- 25tD2332-21/2- 30D2332-21/2- 40D2332-33/2- 50D2332-33/2- 60DAB125/16 857/16 91/257/16 12125/16 857/16 12125/16 8125/16 881/281/267/877773/873/84§ 1011/164§ 1011/166§ 87/86§ 87/86§ 87/86§ 87/88† 91/88† 91/88† 91/88† 91/88† 91/812† 117/812† ———381/2 91/1681/2 91/16101/2 913/16101/2 913/16101/2 913/16113/4 111/8113/4 111/8S T‡333313131313131351 Explanation of designation: 2304-11/1- .3D means Series 2300, 4 osi pressure, inner housing no. 11, 1 stage, 1/3 hp motor, direct drive.dtWith drip-proof motor, if dimensions are different from TEFC.With TEFC motor, if dimensions are different from drip-proof.* Z Motor overhang for TEFC motors. There is no overhang for drip-proof motors, except 2320-33/1- 40D and 2324-33/1- 40D which overhang 1/2".‡ Listed T and U dimensions are for SW inlet. For threaded inlet where S 3", T 13/4"; S 4", T 17/8"; S 6", T 5". If S is greater than 6", threadedinlet is not available.† SW discharge (unthreaded pipe) is included in F. Discharge CL is 109/16" from farthest base hole, for inner housing no. 11.§ Female pipe thread. If SW discharge (unthreaded pipe) is specified, add 31/4" to F.5 holes when No. 4 discharge is furnished. When #4 discharge position is specified, all blowers except those in discharge position group A, B, or C, require a modification of blower base(reference Bulletin 2300).Dimensions 2300-DPage 3

EK–Rad.No. 2S–Inlet Nominal Pipe SizeNo. 3R–dia.3 holes 6 holesIFT‡Base planfor housingsHCL InletG KC 1/16Base planfor housingsHL /16111 through 38Q 1/16L 1/1641, 44, 47L 1/16HL 1/16SWV PBDU‡ThreadedG*ZC 1/16No. 1C 1/16JFF KP No. 4Discharge P109/16for No. 11 HousingA– Discharge Nominal Pipe Size-female pipe thread for 6" and smaller,unthreaded pipe (SW) for 8" and larger.All dimensions are in inches. Dimensions shown apply only to blowers with T-frame motors. Consult Fives North American for dimensions of blowerswith other motors.BlowerDesignation LPQRS �20D6§ 143/86§ 143/86§ 143/8AB7297/8103/4 335/8103/4 335/81717172113/16§ 201/4 127/8 20 165/162113/16§ 201/4 127/8 20 165/162113/16§ 201/4 127/8 20 48 4 323/88 4 361/88 4 /43/43/43101010104444U‡381/16381/16381/16381/16F KG K11/211/211/2V— 381/8§15/16 51/4451/4451/4451/4 Explanation of designation: 2304-11/1- .3D means Series 2300, 4 osi pressure, inner housing no. 11, 1 stage, 1/3 hp motor, direct drive.dtWith drip-proof motor, if dimensions are different from TEFC.With TEFC motor, if dimensions are different from drip-proof.* Z Motor overhang for TEFC motors. There is no overhang for drip-proof motors, except 2320-33/1- 40D and 2324-33/1- 40D which overhang 1/2".‡ Listed T and U dimensions are for SW inlet. For threaded inlet where S 3", T 13/4"; S 4", T 17/8"; S 6", T 5". If S is greater than 6", threadedinlet is not available.† SW discharge (unthreaded pipe) is included in F. Discharge CL is 109/16" from farthest base hole, for inner housing no. 11.§ Female pipe thread. If SW discharge (unthreaded pipe) is specified, add 31/4" to F.5 holes when No. 4 discharge is furnished. When #4 discharge position is specified, all blowers except those in discharge position group A, B, or C, require a modification of blower base(reference Bulletin 2300).Inlet or outlet adapters are not included as standard supply and must be specified at an additional cost."SW" means sleeve or weld. A flexiblerubberized sleeve (Bulletin 2947) canbe slipped over an SW connection andclamped to prevent leaks. A flexible connection does not transmit vibrations orstresses as do welded or threaded connections. Blowers are not designed forimposed loads from hard pipe connectionsand should not be "hard" piped exceptunder unusual circumstances.Fig. 1.Fig. 2.Discharge Connections: A threaded (female) flange (Fig.1) is available with blowers of 6" and smaller discharge pipesize. An SW connection (Fig. 2) is available for 8" and larger,or may be specified for smaller sizes (Fig. 3).Dimensions 2300-DFig. 3.Inlet Connections: An SW inlet (un

March 2010 Series 2300 DIRECT DRIVE TURBO BLOWERS Dimensions 2300-D All dimensions are in inches. Dimensions shown apply only to blowers with T-frame motors.

Related Documents:

EZ1 eldoLED dims to 1% (0-10 volt dimming) GZ1 Dims to 1% (0-10V dimming) GZ10 Dims to 10% (0-10V dimming) SLD Step-level dimming ‡ LP830 82CRI, 3000 K LP835 82CRI, 3500 K LP840 82CRI, 4000 K LP850 82CRI, 5000 K LP930 90CRI, 3000K LP935 90CRI, 3500K LP940 90CRI, 4000K LP950 90CRI, 5000K nLight Interface Control ‡ nLight Wired (blank) no .

Technical Data Model JSON-050 JS RESEARCH INC. Technical Data Page 4 / 6 Technical specifications are subject to change without prior notice SPECIFICATIONS Art. No. JSON-050 Dimension Data Chamber Volume 48 Liters Inner Dims. (W x D x H mm) 400 x 300 x 400 Outer Dims. (W x D x H mm) 560 x 525 x 710 Window Dims.

Technical Data Model JSON-150 JS RESEARCH INC. Technical Data Page 4 / 6 Technical specifications are subject to change without prior notice SPECIFICATIONS Art. No. JSON-150 Dimension Data Chamber Volume 151 Liters Inner Dims. (W x D x H mm) 560 x 450 x 600 Outer Dims. (W x D x H mm) 720 x 675 x 910 Window Dims.

Technical Data Model JSON-100 JS RESEARCH INC. Technical Data Page 4 / 6 Technical specifications are subject to change without prior notice SPECIFICATIONS DESCRIPTIONS MODEL JSON-100 Dimension Data Chamber Volume 100 Liters Inner Dims. (W x D x H mm) 500 x 400 x 500 Outer Dims. (W x D x H mm) 660 x 625 x 810 Window Dims.

Type Turbocharged, four stroke intercooled, Mahindra Common Rail Direct injection diesel Turbocharged, four stroke intercooled, Mahindra Common Rail Direct injection diesel Cylinders 4 4 Engine HP (kW) @ rpm 74.4 (55.4) @ 2300 rpm 83 (61.9) @ 2300 rpm 74.4 (55.4) @ 2300 rpm 83 (61.9) @ 2300 rpm Compression Ratio 17.2:1 17.2:1

the Catalyst 3750-E, the Catalyst 3560-E switches, and the Cisco Redundant Power System 2300 (RPS 2300). For more information about using the power supply modules with a switch or an RPS 2300, see the Catalyst 3750-E and Catalyst 3560-E Switch Hardware Installation Guide and the Cisco RPS 2300 H

Weight 6, dims 20 x 20 x 2, class 100 Note: This is the food shield only. For brackets, see SU-P-317. SU-P-312 Replacement top food shield for buffet table, 2 well (as of 3/1/2015). Includes plastic shield only, no hardware or end panels.’ Weight 20, dims 36 x 32 x 18 ,class 100 SU-P-313 Replacement top food shield for buffet table, 3 well (as of

All material appearing in aliens is the work of individual authors, whose names are listed at the foot of each article. Contributions are not refereed, as this is a newsletter and not an academic journal. Ideas and comments in aliens are not intended in any way to represent the view of IUCN, SSC or the Invasive Species Specialist Group (ISSG) or sponsors, unless specifically stated to the .