Product ManualCheetah Xi P/N: 10-068Addressable Fire SuppressionControl SystemManual P/N: 06-356Rev. No: 4, 03/10

FIKEINTRODUCTIONWorld Headquarters704 SW 10th StreetP.O. Box 610Blue Springs, Missouri 64013U.S.A.Phone: 1.800.979.FIKE (3453) 1.816.229.3405Fax: 1.816.229.0314Copyright InformationWarrantiesThis document may not be reproduced, in wholeor in part, by any means without the prior expresswritten permission of the copyright owner. All Fikedocumentation and hardware are copyrighted withall rights reserved.Fike provides a one-year limited manufacturer'swarranty on this product. The standard warranty isprinted in each Marketing Price List. All warrantyreturns must be returned from an authorized FikeDistributor. Contact Fike's Marketing Department forfurther warranty information. Fike maintains a repairdepartment that is available to repair and ase previously repaired inventorycomponent (advance replacement). All returns mustbe approved prior to return. A Material ReturnAuthorization (MRA) number should be indicated onthe box of the item being returned. Contact theappropriate Regional Sales Manager for furtherinformation regarding Return Material Procedures.Fike is a registered trademark of FikeCorporation.DisclaimersThe information contained in this manual is asaccurate as possible. Fike does not guaranteethat this manual is technically correct, complete, orfree from writing problems or that this product isfree from minor flaws.In accordance with our policy of continuing productand system improvement, Fike reserves the rightto change designs or specifications withoutobligation and without further notice.Reader ResponsesFike encourages input from our distributors andend users on how we can improve this manualand even the product itself. Please direct all callsof this nature to Fike’s Systems Sales Departmentat (800)-979-FIKE (3453), option 21.Any communication receivedproperty of Fike Corporation.UL S2203FM 3020297becomestheLimitation of LiabilityFike Corporation cannot be held liable for anydamages resulting from the use or misuse of thisproduct.Quality NoticeFike Corporation has maintained ISO 9001certification since 1996. Prior to shipment, wethoroughly test our products and review ourdocumentation to assure the highest quality in allrespects.Cheetah Xi Product ManualManual P/N: 06-356-iRev. 4, 03/10

INTRODUCTIONFIKEWarnings, Cautions, Notes and TipsThe following cautions and warnings appear in this manual. Be certain to read all ofthe following warning and cautions before attempting to install or use this device.Personal injury or accidental release of the suppression system may result if thesewarnings and cautions are not followed!Warning Symbol – This symbol is used in this manual to warn of possible injury ordeath from improper use or application of the product under noted conditions.Caution Symbol – This symbol warns of possible personaldamage under noted conditions. Follow all safety standards ofand the recommendations in this manual. Using equipmentdescribed in this manual can present serious safety hazardsdamage.injury or equipmentprofessional practicein ways other thanor cause equipmentNotes – This symbol indicates the message is important, but is not of a Warning orCaution category. These notes can be of great benefit to the user and should be read.Tips – Tips provide advice that may save time during a procedure, or help to clarify anissue. Tips may include additional reference.-iiRev. 4, 03/10Cheetah Xi Product ManualManual P/N: 06-356UL S2203FM 3020297

FIKETABLE OF CONTENTSTABLE OF CONTENTSSectionTitlePage1.0PREFACE . 11.1About This Manual . 11.2Product Support . 11.3Revision History . 11.4Terms Used In This Manual. 12.0SYSTEM OVERVIEW . 32.1Product Description. 32.2Listings and Approvals. 32.3Agency Standards and Compliance. 42.4Related Documentation . 52.5Cheetah Xi Features . 63.0EQUIPMENT/PRODUCTS. 73.1System Modules. 73.2Addressable Devices . 83.3Programming/Configuration Equipment. 93.4Notification Appliances. 93.5Factory Mutual Approved Solenoids . 93.6Batteries and Battery Enclosures. 93.7Spare Parts . 103.8Specifications – System Modules . 113.9Specifications – Addressable Devices . 293.10Specifications – Programming/Configuration Equipment . 363.11Specifications – Batteries and Battery Enclosures . 394.0SYSTEM DESIGN. 414.1Basic System Layout. 414.2Configure the System . 424.3Complete Battery Calculations. 424.4Review Installation Requirements. 424.5Complete Installation Drawings . 424.6Complete Documents With As-built Information . 425.0OPERATION . 435.1Display . 435.2Status LEDS. 445.3Keypad . 455.4System Operational Overview . 495.5Passwords. 495.6System Reset/Power up . 505.7Normal State . 505.8Alarm / Waterflow State . 505.9Summing Alarm State . 515.10Alarm Verification State . 515.11Trouble State. 515.12Supervisory State. 515.13Pre-Discharge State. 525.14Abort State . 525.15Release State. 535.16Zone Disable State. 535.17Pre-Alarm State. 535.18Process State. 545.19Walk-test State. 545.20Acclimate. 555.21AC Trouble Delay. 55UL S2203FM 3020297Cheetah Xi Product ManualManual P/N: 06-356-iiiRev. 4, 03/10

TABLE OF 325.335.345.355.365.375.385.395.40FIKEAlarm Verification.55City Tie/Masterbox.55Class A Operation.56Daylight Savings .56Day/Night/Holiday Schedule .56Device LED Operation .56Diagnostics .56Drift Compensation .56Drill Action.57Flame Enhance.57History Buffer .57Maintenance Menu .59Network Operation.61Positive Alarm Sequence.61Relay Base .61Silence Inhibit .62Silence Reminder .62Sounder Base .62Summing.626.0INSTALLATION.636.1Install Enclosure(s) .636.2Pull Field Wiring – Segregate Power Limited From Non-Power Limited.676.3Install Transformer and Wire AC to Transformer .696.4Install Optional Electronics Onto Main Controller.706.5Install Controller (and DACT if Used) Into Back-box .726.6Connect AC and Batteries to Controller and Power up. Validate Working. Power Down .726.7Connect Field Wiring .736.8Power Up with Devices Connected .846.9Configure System .847.0CONFIGURATION.897.1C-Linx Software .897.2Control Panel Auto-Configure.897.3Device Configurations.907.4Main Board Configurations .937.5Panel Configuration Menu’s .948.0SERVICE .1118.1Checkout.1118.2Maintenance .1118.3Troubleshooting .1118.4Voltages.1198.5Event Description/History .120APPENDIX 1 - BATTERY CALCULATION FORM .139"SYSTEM OPERATION POSTING".141APPENDIX 3 – CHEETAH XI MENU STRUCTURE.143APPENDIX 4 – PRE-DISCHARGE AND ABORT TYPES .145-ivRev. 4, 03/10Cheetah Xi Product ManualManual P/N: 06-356UL S2203FM 3020297

FIKETABLE OF CONTENTSLIST OF EXHIBITSExhibit 2-1 Cheetah Xi Block Diagram.3Exhibit 3-1 Cheetah Xi Control System.11Exhibit 3-2 Cheetah Xi Controller.12Exhibit 3-3 Cheetah Xi Terminal Block Locations.12Exhibit 3-4 Terminal P1.13Exhibit 3-5 Terminal P2.14Exhibit 3-6 Terminal P3-P5 .14Exhibit 3-7 Terminal P6.15Exhibit 3-8 Terminal P7.15Exhibit 3-9 Terminal P8 & P9 .16Exhibit 3-10 Terminal P10 & P11.17Exhibit 3-11 NAC Circuit Field Wiring Resistance .17Exhibit 3-12 DACT .19Exhibit 3-13 DACT Programmer .19Exhibit 3-14 SPS .20Exhibit 3-15 SLM.21Exhibit 3-16 CRM4 .22Exhibit 3-17 CRPM.22Exhibit 3-18 Network Module .23Exhibit 3-19 Fiber Optic Module.23Exhibit 3-20 Remote Display.24Exhibit 3-21 14-Button Remote Display .24Exhibit 3-22 10-Button Remote Display .25Exhibit 3-23 2-Button Remote Display .25Exhibit 3-24 Zone Annunciator.26Exhibit 3-25 Ethernet Module.26Exhibit 3-26 Multi-Interface Module .27Exhibit 3-27 VESDA Open Protocol HLI .27Exhibit 3-28 LED Graphic.28Exhibit 3-29 Twenty Zone Remote Annunciator .28Exhibit 3-30 Photo Sensor .29Exhibit 3-31 Ion Sensor.29Exhibit 3-32 Photo/Heat Sensor.30Exhibit 3-33 Thermal Sensor .30Exhibit 3-34 Sensor Bases, 6” & 4”.31Exhibit 3-35 Sounder Base .31Exhibit 3-36 Relay Base.31Exhibit 3-37 Module Cover, 4” .32Exhibit 3-38 Mini & 4” Input Modules .32Exhibit 3-39 Input Module Functions.32Exhibit 3-40 Addressable Pull Station.33Exhibit 3-41 Supervised Control Module.33Exhibit 3-42 Solenoid Series Impedance .33Exhibit 3-43 MasterBox Interface.33Exhibit 3-44 Relay Module .34Exhibit 3-45 Releasing Control Module.34Exhibit 3-46 DUCT Sensor.35Exhibit 3-47 IR Remote Tool .36Exhibit 3-48 Hand Held Programmer .37Exhibit 3-49 DB9 Communication Cable.38Exhibit 3-50 USB/232 Communication Cable .38Exhibit 3-51 USB Communication Cable .38Exhibit 3-52 Batteries .39Exhibit 3-53 33 AH Battery Enclosure.39Exhibit 3-54 75 AH Battery Enclosure.39Exhibit 5-1 Cheetah Xi Display .43UL S2203FM 3020297Cheetah Xi Product ManualManual P/N: 06-356-vRev. 4, 03/10

TABLE OF CONTENTSFIKEExhibit 5-2 System Status Display. 43Exhibit 5-3 System Event Display. 43Exhibit 5-4 Top Level Menu . 43Exhibit 5-5 Top Level Menu Display . 47Exhibit 5-6 Password Menu . 49Exhibit 5-7 Reset Display. 50Exhibit 5-8 System Status Display. 50Exhibit 5-9 Alarm Display. 50Exhibit 5-10 Trouble Display. 51Exhibit 5-11 Supervisory Display . 52Exhibit 5-12 Pre-Discharge Display. 52Exhibit 5-13 Abort Display . 52Exhibit 5-14 Release Display. 53Exhibit 5-15 Zone Disable Display. 53Exhibit 5-16 Pre-Alarm Display. 54Exhibit 5-17 Process Display . 54Exhibit 5-18 Walktest Display . 55Exhibit 5-19 Drill Display. 57Exhibit 5-20 History Menu. 58Exhibit 5-21 Alarm History Menu . 58Exhibit 5-22 Supervisory History Menu . 58Exhibit 5-23 Trouble History Menu . 58Exhibit 5-24 Events History Menu . 58Exhibit 5-25 Zone History Menu . 58Exhibit 5-26 Erase History Menu . 58Exhibit 5-27 Erase History Status . 58Exhibit 5-28 Maintenance Menu .

INTRODUCTION FIKE -ii- Cheetah Xi Product Manual UL S2203 Rev. 4, 03/10 Manual P/N: 06-356 FM 3020297 Warnings, Cautions, Notes and Tips The following cautions and warnings appear in this manual. Be certain to read all of the following warning and

Related Documents:

addressable fire alarm control panel 2 loop addressable fire alarm control panel 4 loop addressable fire alarm control panel 6 loop addressable fire alarm control panel 8 loop addressable fire alarm control panel product code: m.u.yan.00016 product code: m.u.yan.00018 battery included product code: m.u.yan.00020 product code: m.u.yan.00022

Rosta 02.068.0180 24 2 068.019 Anschlag progressiv-konisch 02.068.0190 23 4 - - 6.4x25x1.8 - Material nicht festgelegt 10.050.0223 22 2 Gewindestift mit Messingzapfen Schrauben material 02.068.0370 21 4 - - Sicherungsscheibe Nord-Lock M10 Schrauben material 10.050.0312 20 1 101.724 C Motor

48 4.25 phn-13-48 28 pcx 068/073 10 54 4.25 phn-13-54/57 28 pcx 068/073 10 57 4.25 phn-13-54/57 28 pcx 068/073 10 60 4.75 phn-13-60/64 24 pcx 082/085 10 64 4.75 phn-13-60/64 24 pcx 082/085 10

TrueAlert Non-Addressable A/V and V/O Weatherproof Appliances Setting the Strobe Candela Rating All 4906 Weatherproof Non-Addressable Multi-Ca ndela notification appliances have jumper selectable candela ratings for the strobe. The strobe can be selected to the desired intensity by inserting the jumper in the a ppropriate position (15, 60, 75 or WP75 candela). See Figure 4. Note: The jumper is .

TrueAlert Addressable Notification Appliances S49AV-0001 Rev. 7 3/2018 Features Individually addressed and controlled multi-candela TrueAlert ES A/V (audible/visible) notification appliances provide: Multi-candela xenon strobe with synchronized 1 Hz flash rate and with intensity programmable from the control panel or jumper selected as 15, 30, 75, 110, 135, or 185 cd Advanced addressable .

Non-addressable devices, including smoke and heat detectors that incorporate advanced technology and pull stations are also available. Notification Appliances Our TrueAlert family of notification appliances includes both addressable and non-addressable horns, visuals, speakers, and combination (audible/visible) units. *We also offer products such as door holders and waterflow and tamper .

Addressable Device - A fire alarm system component with discreet identification that can have its status individually identified or that is used to individually control other functions. Analog Addressable Sensor - An initiating device that transmits a signal indicating varying degrees of condition as contrasted with a conventional or addressable initiating device, which can only indicate an .

Extinguishant Control System HP102-4 Extinguishant Control panel 20 HF115/116/119 Components of extinguishant system 21 Schematic diagram of extinguishant control system 22 Addressable Fire Alarm System HD201/202/203 Addressable fire alarm detectors 24 HC202/HM201-R Addressable call poin