Fire Alarm Systems (Conventional & Addressable)

1y ago
34 Views
3 Downloads
1.09 MB
15 Pages
Last View : 1d ago
Last Download : 3m ago
Upload by : Gia Hauser
Transcription

Fire Detection andSecurity SystemsFire Alarm Systems(Conventional & Addressable)42

Fire Detection andSecurity SystemsFire Detection and Security SystemsADDRESSABLEFire Detection and Security Systems43

Fire Detection and Security SystemsADDRESSABLE FIRE ALARM CONTROL PANELQty PerPackageFire Detection andSecurity Systems 1Mains input voltageOperating voltageBatteryBattery charging currentSMPS power supply outputSiren outputsError relay outputFire alarm relay outputSystem fuseNumber of loopsNumber of loop devicesNumber of devicesNumber of addressable sirensNumber of conventional siren outputsNumber of conventional sirenEnd of line resistorNumber of zonesFire and error event memory capacityNumber of network devicesDimensionsOperating temperatureHumidityType of mountingCable entryLength of loop cableMembrane panelExpandable structure up to 8 loopsSimple installation and usageDeactivation of the loop during fire alarmAlarm and error relay outputsDeactivatable devices, loops, outputs and zonesAbility to set delay to devices, loops and zonesCan be connected to conventional sirensFire and error memory1 LOOP ADDRESSABLE FIRE ALARM CONTROL PANELPRODUCT CODE: M.U.YAN.00015Battery Included3 LOOP ADDRESSABLE FIRE ALARM CONTROL PANELPRODUCT CODE: M.U.YAN.00017Battery Included5 LOOP ADDRESSABLE FIRE ALARM CONTROL PANELPRODUCT CODE: M.U.YAN.00019Battery Included7 LOOP ADDRESSABLE FIRE ALARM CONTROL PANELPRODUCT CODE: M.U.YAN.00021Battery Included44TECHNICAL DETAILS230V AC 50 Hz24VDC2 units 12V DC 7 Ah0.5A4.5 A2 units 24V 1A capacity, glass fuse protectedDRY CONTACT 1A 120VAC/2A 24VDCDRY CONTACT 1A 120VAC/2A 24VDC5A glass fuseFrom 1 to 8Max. 128 devicesMax. 1024 devicesMax. 10 units/loop2Max. 20 siren for each output47K 1/4W for siren line321000 events per deviceMax. 16 control panels or repeaters40x47x13 cm-10 C / 55 CUp to % 95Surface TypeTopMax. 1500m or 50 Ω 4x20 LCD displayAlarm, error and zone LEDsQuery buttons for fire and error eventsAddressing devices through the control panelDetection of location via PC connection or via control panelCan establish a network with control panels and repeaterpanels Produced with surface mounting technology2 LOOP ADDRESSABLE FIRE ALARM CONTROL PANELPRODUCT CODE: M.U.YAN.00016Battery Included4 LOOP ADDRESSABLE FIRE ALARM CONTROL PANELPRODUCT CODE: M.U.YAN.00018Battery Included6 LOOP ADDRESSABLE FIRE ALARM CONTROL PANELPRODUCT CODE: M.U.YAN.00020Battery Included8 LOOP ADDRESSABLE FIRE ALARM CONTROL PANELPRODUCT CODE: M.U.YAN.00022Battery Included

Fire Detection and Security SystemsADDRESSABLE OPTICAL SMOKE DETECTORTECHNICAL DETAILSOPERATING VOLTAGEOPERATING CURRENTDETECTION AREACONNECTION TYPEOPERATING TEMPERATUREMATERIALDIMENSIONSCOLORPROCESSOR DESIGNSURFACE MOUNTING TECHNOLOGY360 DEGREE VISIBLE DUAL LEDLED INDICATOR TO DISPLAY ‘’DETECTOR IS ON’’ADVANCED SMOKE DETECTION BY SPECIALLYDESIGNED SMOKE CELL AND PROCESSORADDRESSABLE DETECTORS OUTPUT FOR CONNECTING TO REMOTE LEDINDICATORADDRESSABLELOOP-POWEREDQty PerPackage36ADDRESSABLE DETECTORS WITH ISOLATORSTANDARDSEN54-7: 2000EN54-7: 2000/A1: 2002EN54-7: 2000/A2: 2006ADDRESSABLE OPTICALSMOKE DETECTOR PRODUCT CODE: M.U.YAN.00023Fire Detection and Security SystemsADDRESSABLE FIXED TEMPERATURE HEAT DETECTORAlarm Temperature : 65 CPRODUCT CODE: M.U.YAN.00029ADDRESSABLE OPTICAL SMOKE DETECTORWITH ISOLATORPRODUCT CODE: M.U.YAN.00035Fire Detection andSecurity Systems 24V-34V DC 250µA50 m² for ceiling height up to 4 meters3 CABLES (FOR ISOLATOR MODEL)2 CABLES (FOR STANDARD MODEL)-10 C / 55 CFIREPROOF PLASTIC122 mm DIAMETER , 52 mm HEIGHTWHITEADDRESSABLE FIXED TEMPERATURE HEAT DETECTORWITH ISOLATORPRODUCT CODE: M.U.YAN.00036ADDRESSABLE RATE OF RISE HEAT DETECTORAlarm Rate of Rise : According toEN54-5 StandardPRODUCT CODE: M.U.YAN.00030ADDRESSABLE RATE OF RISE HEATDETECTOR WITH ISOLATORPRODUCT CODE: M.U.YAN.00037ADDRESSABLE FIXED TEMPERATURE &RATE OF RISE HEAT DETECTORSTANDARDSEN54-5: 2000EN54-5: 2000/A1: 2002Alarm Rate of Rise: According toEN54-5 StandardAlarm Temperature : 65 CPRODUCT CODE: M.U.YAN.00031ADDRESSABLE FIXED TEMPERATURE & RATEOF RISE HEAT DETECTOR WITH ISOLATORPRODUCT CODE: M.U.YAN.00038ADDRESSABLE MULTI DETECTOR(SMOKE FIXEDTEMPERATURE RATE OF RISE)STANDARDSEN54-5: 2000, EN54-5: 2000/A1: 2002,EN54-7: 2000, EN54-7: 2000/A1: 2002EN54-7: 2000/A2: 2006ADDRESSABLE MULTI DETECTORWITH ISOLATORAlarm Rate of Rise: According to EN54-5StandardAlarm Temperature : 65 CPRODUCT CODE: M.U.YAN.00039PRODUCT CODE: M.U.YAN.00024ADDRESSABLE NATURAL GAS DETECTORAlarm Threshold ValueSensor Warm-up Time: 5 % - 15 % LEL: 1 min.PRODUCT CODE: M.U.YAN.0004045

Fire Detection and Security SystemsADDRESSABLE SOCKET BASEBATTERYPRODUCT CODE: H.E.AKU.00005Battery Voltage12VBattery Capacity 7AhQty PerPackage1PRODUCT CODE: MU.YAN.00079DimensionsLength 151 mm X Width 65 mm XHeight 99 mmWeight1,97 kgLiftetime5 yearsFire Detection andSecurity SystemsADDRESSABLE MANUAL CALL POINTADDRESSABLE MANUAL CALL POINTWITH ISOLATORSTANDARDSEN54-11: 2001/A1: 2005PRODUCT CODE: M.U.YAN.00026 PROCESSOR DESIGNSURFACE MOUNTING TECHNOLOGYRESET FEATUREADDRESSABLELOOP-POWEREDMECHANICAL TRIGGER MECHANISMWARNING LEDTECHNICAL DETAILS PROCESSOR DESIGNSURFACE MOUNTING TECHNOLOGYRESET FEATUREBUILT-IN SHORT CIRCUIT ISOLATORADDRESSABLELOOP-POWEREDMECHANICAL TRIGGER MECHANISMWARNING LEDTECHNICAL DETAILSOPERATING VOLTAGE24V-34V DCOPERATING VOLTAGE24V-34V DCOPERATING CURRENT 250µAOPERATING CURRENT 250µAOPERATING TEMPERATURE-10 C / 55 COPERATING TEMPERATURE-10 C / 55 CMATERIALFIREPROOF PLASTICMATERIALFIREPROOF PLASTICDIMENSIONS10x10x4.5 cmDIMENSIONS10x10x4.5 cmRWIDTHKKIRMIZICOLORREDQty PerPackage46PRODUCT CODE: M.U.YAN.0004250Qty PerPackage50

Fire Detection and Security SystemsADDRESSABLE FIRE ALARM SIREN PROCESSOR DESIGNSURFACE MOUNTING TECHNOLOGYADDRESSING BY ADDRESSABLE DEVICE**LOOP-POWEREDTECHNICAL DETAILS24V-34V DCQUIESCENT CURRENT 250µAALARM CURRENT 25mASOUND OUTPUT100 dB AT 1 METEROPERATING TEMPERATURE-10 C / 55 CMATERIALFIREPROOF PLASTICDIMENSIONS11x7x5 cmCOLORREDADDRESSABLE FIRE ALARM SIRENQty PerPackageSTANDARDSEN54-3: 2001EN54-3: 2001/A1: 2002EN54-3: 2001/A2: 200650ADDRESSABLE FIRE ALARM SIREN WITH ISOLATORFire Detection and Security SystemsPRODUCT CODE: M.U.YAN.00027Fire Detection andSecurity SystemsOPERATING VOLTAGEPRODUCT CODE: M.U.YAN.00043ADDRESSABLE FIRE ALARM SIREN WITH STROBEPROCESSOR DESIGNSURFACE MOUNTING TECHNOLOGYBUILT-IN SHORT CIRCUIT ISOLATORADDRESSABLELOOP-POWEREDALARM ACTIVATED STROBE WARNING LEDsTECHNICAL DETAILSOPERATING VOLTAGE24V-34V DCQUIESCENT CURRENT 250µAALARM CURRENT 25mASOUND OUTPUT100 dB AT 1 METEROPERATING TEMPERATURE-10 C / 55 CMATERIALFIREPROOF PLASTICDIMENSIONS11x7x5 cmCOLORREDADDRESSABLE FIRE ALARM SIREN WITHSTROBEPRODUCT CODE: M.U.YAN.00028Qty PerPackage50ADDRESSABLE FIRE ALARM SIREN WITH STROBEWITH ISOLATORPRODUCT CODE: M.U.YAN.0004447

Fire Detection and Security SystemsTECHNICAL DETAILSSHORT CIRCUIT ISOLATOR SURFACE MOUNTINGOPERATING VOLTAGE24V-34V DCTECHNOLOGYQUIESCENT CURRENT 250µARED SHORT CIRCUIT WARNING LEDSHORT CIRCUIT CURRENT 3mAOPERATING TEMPERATURE-10 C / 55 CDIMENSIONS8X8X4 cmPROTECTS LOOP LINE FROMPOSSIBLE SHORT CIRCUIT EVENTS 1 UNIT FOR EVERY 20 ADDRESSABLEDEVICES50Qty PerPackagePRODUCT CODE: M.U.YAN.00032TECHNICAL DETAILSREMOTE LED INDICATOR SURFACE MOUNTINGOPERATING VOLTAGE24V-34V DCTECHNOLOGYOPERATING VOLTAGE 5mAUSED AS THE REMOTE LEDOPERATING TEMPERATURE-10 C / 55 CDIMENSIONS8X8X4 cmINDICATOR OF THE HARD TOSEE DETECTORS DUE TO RAISEDCEILING LAYERS OR SUSPENDEDCEILINGFire Detection andSecurity SystemsQty PerPackage50ADDRESS PROGRAMMER TECHNICAL DETAILSSURFACE MOUNTING TECHNOLOGYUSED FOR ADDRESSING ADDRESSABLEFIRE ALARM DEVICESCAN BE POWERED BY BATTERY ORADAPTORAUTOMATIC POWER-OFF FEATURE FORPOWER-SAVING2X16 LCD SCREENQty PerPackageRELAY MODULE AND CONTACTMONITORING MODULEPRODUCT CODE: M.U.YAN.00033INPUT VOLTAGE9V - 12V DCBATTERY9VEXTERNAL FEEDING12V DCOPERATING CURRENT 50mAOPERATING TEMPERATURE-10 C / 55 CDIMENSIONS190x150x32 mm1PRODUCT CODE: M.U.YAN.00045TECHNICAL DETAILSOPERATING VOLTAGE24V-34V DCOPERATING CURRENT 250µARELAY OUTPUTDRY CONTACT (30V DC 2A)CONTACT TYPESNO or NC optionalOPERATING TEMPERATURE-10 C / 55 CDIMENSIONS175x106x76 mmQty PerPackage SURFACE MOUNTING TECHNOLOGY LOOP LINE-POWERED NO VOLTAGE NORMALLY OPEN OR CLOSE (NO or NC) 48CAN PROGRAM AN EVENT BY COMPUTER SOFTWAREABILITY TO DESIGNATE DIFFERENT ADDRESSES FOR EACHINPUT AND OUTPUT SHORT CIRCUIT, LOOP COMMUNICATION, EVENT LEDsBENEATH THE SIDE FLAPSCONTACTS 24 OPTIONAL BUILT-IN SHORT CIRCUIT ISOLATOR

Fire Detection and Security SystemsRELAY MODULES WITH ISOLATORADDRESSABLE 1-CH OUTPUT RELAYMODULEPRODUCT CODE: M.U.YAN.00048ADDRESSABLE 2-CH OUTPUT RELAY MODULEPRODUCT CODE: M.U.YAN.00050ADDRESSABLE 4-CH OUTPUT RELAYMODULEPRODUCT CODE: M.U.YAN.00052CONTACT MONITORING MODULEADDRESSABLE 1-CH INPUT CONTACTMONITORING MODULEPRODUCT CODE: M.U.YAN.00054Fire Detection and Security SystemsADDRESSABLE 2-CH INPUT CONTACTMONITORING MODULEPRODUCT CODE: M.U.YAN.00056ADDRESSABLE 4-CH INPUT CONTACTMONITORING MODULEPRODUCT CODE: M.U.YAN.00058RELAY MODULE AND CONTACT MONITORINGMODULEADDRESSABLE 1-CH OUTPUT RELAY MODULE & 1-CHINPUT CONTACT MONITORING MODULEPRODUCT CODE: M.U.YAN.00060ADDRESSABLE 2-CH OUTPUT RELAY MODULE & 2-CHINPUT CONTACT MONITORING MODULEPRODUCT CODE: M.U.YAN.00062ADDRESSABLE 4-CH OUTPUT RELAY MODULE & 4-CHINPUT CONTACT MONITORING MODULEPRODUCT CODE: M.U.YAN.00064ADDRESSABLE 1-CH OUTPUT RELAYMODULE WITH ISOLATORPRODUCT CODE: M.U.YAN.00049ADDRESSABLE 2-CH OUTPUT RELAYMODULE WITH ISOLATORPRODUCT CODE: M.U.YAN.00051ADDRESSABLE 4-CH OUTPUT RELAYMODULE WITH ISOLATORPRODUCT CODE: M.U.YAN.00053CONTACT MONITORING MODULE WITH ISOLATORADDRESSABLE 1-CH INPUT CONTACTMONITORING MODULE WITH ISOLATORPRODUCT CODE: M.U.YAN.00055Fire Detection andSecurity SystemsRELAY MODULESADDRESSABLE 2-CH INPUT CONTACT MONITORINGMODULE WITH ISOLATORPRODUCT CODE: M.U.YAN.00057ADDRESSABLE 4-CH INPUT CONTACT MONITORINGMODULE WITH ISOLATORPRODUCT CODE: M.U.YAN.00059RELAY MODULE AND CONTACT MONITORINGMODULE WITH ISOLATORADDRESSABLE 1-CH OUTPUT RELAY MODULE & 1-CH INPUTCONTACT MONITORING MODULE WITH ISOLATORPRODUCT CODE: M.U.YAN.00061ADDRESSABLE 2-CH OUTPUT RELAY MODULE & 2-CH INPUTCONTACT MONITORING MODULE WITH ISOLATORPRODUCT CODE: M.U.YAN.00063ADDRESSABLE 4-CH OUTPUT RELAY MODULE & 4-CH INPUTCONTACT MONITORING MODULE WITH ISOLATORPRODUCT CODE: M.U.YAN.0006549

Fire Detection and Security SystemsADDRESSABLE LOOP MONITORING ANDSIREN CONTROL MODULETECHNICAL DETAILSOPERATING VOLTAGESIREN OUTPUTNUMBER OF OUTPUTSSIREN CAPACITYNUMBER OF INPUTSLOOP INPUTSOPERATING TEMPERATUREDIMENSIONS SURFACE MOUNTING TECHNOLOGYEXTERNALLY POWEREDCONNECTS CONVENTIONAL SYSTEM DEVICES TOADDRESSABLE SYSTEMABILITY TO CONNECT CONVENTONAL DETECTORSAND BUTTONS TO MODULE INPUTSCONVENTIONAL SIREN OUTPUTSSIREN CONTROL MODULESADDRESSABLE 1-CH OUTPUT SIREN CONTROL MODULEFire Detection andSecurity SystemsPRODUCT CODE: M.U.YAN.00066ADDRESSABLE 2-CH OUTPUT SIREN CONTROLMODULEPRODUCT CODE: M.U.YAN.00068CONVENTIONAL SYSTEM INPUT MODULESADDRESSABLE 1-CH CONVENTIONAL SYSTEM INPUTMODULEPRODUCT CODE: M.U.YAN.00070ADDRESSABLE 2-CH CONVENTIONAL SYSTEMINPUT MODULEPRODUCT CODE: M.U.YAN.00072SIREN CONTROL – CONVENTIONAL SYSTEM INPUTMODULESADDRESSABLE 1-CH OUTPUT SIREN CONTROL & 1CONVENTIONAL SYSTEM INPUT MODULEPRODUCT CODE: M.U.YAN.00074ADDRESSABLE 2-CH OUTPUT SIREN CONTROL & 2-CHCONVENTIONAL SYSTEM INPUT MODULEPRODUCT CODE: M.U.YAN.0007650 24V DC500 mA FUSED210 UNITS PER ONE OUTPUT216 CONVENTIONAL DETECTORSAND UNLIMITED BUTTONS PERINPUT-10 C / 55 C175x106x76 mmCAN PROGRAM AN EVENT BY COMPUTERSOFTWAREABILITY TO DESIGNATE DIFFERENT ADDRESSES FOREACH INPUT AND OUTPUTOPTIONAL BUILT-IN SHORT CIRCUIT ISOLATORLED INDICATORS FOR ALARM AND ERRORQty PerPackage24SIREN CONTROL MODULES WITH ISOLATORADDRESSABLE 1-CH OUTPUT SIREN CONTROLMODULE WITH ISOLATORPRODUCT CODE: M.U.YAN.00067ADDRESSABLE 2-CH OUTPUT SIREN CONTROL MODULEWITH ISOLATORPRODUCT CODE: M.U.YAN.00069CONVENTIONAL SYSTEM INPUT MODULES WITHISOLATORADDRESSABLE 1-CH CONVENTIONAL SYSTEM INPUTMODULE WITH ISOLATORPRODUCT CODE: M.U.YAN.00071ADDRESSABLE 1-CH CONVENTIONAL SYSTEM INPUTWITH ISOLATORPRODUCT CODE: M.U.YAN.00073SIREN CONTROL – CONVENTIONAL SYSTEM INPUTMODULES WITH ISOLATORADDRESSABLE 1-CH OUTPUT SIREN CONTROL & 1-CHCONVENTIONAL SYSTEM INPUT MODULE WITH ISOLATORPRODUCT CODE: M.U.YAN.00075ADDRESSABLE 2-CH OUTPUT SIREN CONTROL & 2-CHCONVENTIONAL SYSTEM INPUT MODULE WITH ISOLATORPRODUCT CODE: M.U.YAN.00077

Fire Detection and Security SystemsBATTERY SUPPORTED 24VPOWER SUPPLYPRODUCT CODE: M.U.YAN.00046 SURFACE MOUNTING TECHNOLOGYSUPPLIES POWER TO MAX. 40 ADDRESSABLE ANDCONVENTIONAL GAS DETECTORSSMPS and BATTERY INCLUDEDRELAY OUTPUT FOR ERROR EVENTSLED INDICATORS FOR ERROR OR ON/OFFMAINS INPUT VOLTAGE230V AC 50 HzBATTERY2 UNIT 12V 7AhOUTPUT VOLTAGE24V DCOUTPUT CURRENT4.5AOUTPUT RELAY24VDC 2A DRY CONTACTOPERATING TEMPERATURE/ 55 C SystemsFire Detection-10 Cand SecurityDIMENSIONS31.5x32.5x11.5 cmQty PerPackage1Qty PerPackage1Fire Detection andSecurity SystemsTECHNICAL DETAILSADDRESSABLE REPEATERPANELPRODUCT CODE: M.U.YAN.00047 SURFACE MOUNTING TECHNOLOGYABILITY TO MONITOR ALL WARNINGS REMOTELYREMOTE CONTROL FEATURE OF UP TO 16ADDRESSABLE CONTROL PANELS4 X 20 CHARACTER LCD DISPLAYLED INDICATORS for ALARM and FIRE EVENTSSMPS and BATTERY INCLUDEDTECHNICAL DETAILSMAINS INPUT VOLTAGE230V AC 50 HzPOWER CONSUMPTION 10WBATTERY12V 4.5AhOPERATING TEMPERATURE-10 C / 55 CDIMENSIONS31.5x32.5x11.5 cm51

Fire Detection andSecurity SystemsCONVENTIONALFire Detection and Security Systems52

Fire Detection and Security SystemsCONVENTIONAL FIRE ALARM CONTROL PANEL230V AC 50 HzOperating voltage24V DCBattery2 units 12V DC 4AhBattery charging currentMax. 0.5ABattery fuse0.5ASMPS power supply output2.5ASiren outputs2 units 24V 0.5A capacity, glass fuse protectionAuxiliary 24V output24V 0.5A capacity, glass fuse protectionFire alarm relay output1A 120VAC / 2A 24VDCError alarm relay output1A 120VAC / 2A 24VDCSystem fuse4A glass fuseHeat detector capacity perzone16Smoke detector capacityper zone16Manual call point capacityper zoneUnlimitedQty PerPackage1 Membrane panel Alarm and error LEDs for each zone 24V battery voltage Alarm and error relays(NO,NC,COM) Contact output External 24V output can supplypower to 5 gas detectors Alarm and error verification in 5seconds Earthing error detection Mains power status warning LED Battery error LED Siren output monitoring andwarning Deactivatable zones Ability to set delay to alarm output Testable by one person Produced with surface mountingtechnologyFire Detection andSecurity SystemsMains input voltageFire Detection and SecuritySystemsEnd of lineresistanceSTANDARDSEN54-2: 1997EN54-2: 1997/AC: 1999EN54-2: 1997/A1: 2006TECHNICAL DETAILSFor conventional zone : 4K7 1/4W, for siren line 4K7 1/4WNumber of zones4-8-16 zonesDimensions31.5 x 32.5 x 11.5cmOperating temperature-10 C / 55 CHumidityUp to %95Type of mountingSurface TypeCable entryTop4 ZONE CONVENTIONAL FIRE ALARM CONTROL PANELPRODUCT CODE: M.U.YAN.00006Battery Included8 ZONE CONVENTIONAL FIRE ALARM CONTROL PANELPRODUCT CODE: M.U.YAN.00005Battery Included16 ZONE CONVENTIONAL FIRE ALARM CONTROL PANELPRODUCT CODE: M.U.YAN.00004Battery Included53

Fire Detection and Security SystemsCONVENTIONAL FIRE ALARM DETECTORSTECHNICAL DETAILSOperating Voltage10V - 24V DCQuiescient Current 200 μAAlarm Current15mADetection area50m² for ceiling height up to 4 metersConnection Type3 cable and 1 monitoring indicator outputsOperating Temperature -10 C / 55 CMaterialFireproof plasticDimensions122mm diameter, 52mm heightColorWhiteProcessor designLed indicator to display that detector is ON/OFFProduced with surface mounting technologyAdvanced smoke detection by specially designed360 degree visible dual ledsmoke cell and processorCONVENTIONAL OPTICALSMOKE DETECTORSTANDARDSEN54-7: 2000EN54-7: 2000/A1: 2002EN54-7: 2000/A2: 2006PRODUCT CODE: M.U.YAN.00001Qty PerPackage36CONVENTIONAL MULTI DETECTOR(SMOKE FIXED TEMPERATURE RATE OFRISE HEAT)Fire Detection andSecurity SystemsAlarm Rate of RiseCONVENTIONAL RATE OF RISE HEAT DETECTOR: According toEN54-5 StandardAlarm Temperature : 65 CAlarm Rate of Rise : According toEN54-5 StandardPRODUCT CODE: M.U.YAN.00010STANDARDSEN54-5: 2000EN54-5: 2000/A1: 2002, EN54-7: 2000EN54-7: 2000/A1: 2002EN54-7: 2000/A2: 2006CONVENTIONAL FIXED-TEMPERATURE HEATDETECTORAlarm Temperature : 65 CPRODUCT CODE: M.U.YAN.00009PRODUCT CODE: M.U.YAN.00008CONVENTIONAL FIXED TEMPERATURE / RATE OFRISE HEAT DETECTORAlarm Rate of Rise: According toEN54-5 StandardAlarm Temperature : 65 CSTANDARDSEN54-5: 2000EN54-5: 2000/A1: 2002PRODUCT CODE: M.U.YAN.00011CONVENTIONAL NATURAL GAS DETECTORAlarm Threshold ValueSensor Warm-up Time: 5 % - 15 % LEL: 1 min.PRODUCT CODE: M.U.YAN.00013CONVENTIONAL SOCKET BASEQty PerPackage1PRODUCT CODE: M.U.YAN.0001254

Fire Detection and Security SystemsCONVENTIONAL FIRE ALARM SIRENSTECHNICAL DETAILSOperating Voltage24V DCOperating Voltage24V DCOperating Current50mA without StrobeOperating Current60mA with StrobeSound Output100 dB at 1 meterSound Output100 dB at 1 meterColorRedColorRedDimensions11 x 7 x 5 cmDimensions11 x 7 x 5 cmOperatingConditions-10 C / 55 C andup to %95 moistureOperatingConditions-10 C / 55 C andup to %95 moistureProduced with surface mounting technologyQty PerPackageCan be mounted surface typeCONVENTIONAL FIRE ALARM SIREN50CONVENTIONAL FIRE ALARM SIRENWITH STROBESTANDARDSEN54-3: 2001EN54-3: 2001/A1: 2002EN54-3: 2001/A2: 2006PRODUCT CODE: M.U.YAN.00007CONVENTIONAL MANUAL CALL POINTTECHNICAL DETAILSFire Detection and Security SystemsOperating VoltageQuiescient CurrentAlarm CurrentProtection ClassColorDimensionsAlarm Resistance24V DC0 mA15mAIP24Red10 x 10 x 4,5 cm2K2 Ω for 5 sec.Produced with surface mounting technologyQty PerPackageReset featureIlluminated warning feature on button pressReset-key includedSTANDARDSEN54-11: 2001/A1: 200550PRODUCT CODE: M.U.YAN.00003CONVENTIONAL FIRE DETECTOR TEST SPRAYTECHNICAL DETAILSTECHNICALDETAILS CAS NoHazardousingredientsWeight ratio %Hazard classificationPropan-2-ol67-63-010 - -710 - 2010 - 2050 - 70Flam. Liq. 2, H225 / Eye Irrit. 2,H319 / STOT SE 3, H336Flam. Gas 1 H220Flam. Gas 1 H220Flam. Gas 1 H220250 mlCleans dirty and dusty detectorsPrevents false alarmsImproves sensitivityProvides a fast and safe way ofcleaning the detectorNon-inflammableEffectiveEasy to useNon-corrosiveVolume : 6.6cm diameter, height :15cm o/aIt can be used on all type of detectorbrandsQty PerPackage1PRODUCT CODE: M.U.YAN.0002555Fire Detection andSecurity SystemsPRODUCT CODE: M.U.YAN.00002

Fire Detection and Security SystemsBATTERYTECHNICAL DETAILSBattery Voltage12VBattery Capacity4.5 AhDimensionsLenght 90mm X Width 70mm XHeight 101 mmWeight1,23 kgLifetime5 yearsQty PerPackage1PRODUCT CODE: M.U.AKU.00001Fire Detection andSecurity SystemsCONVENTIONAL SYSTEM REPEATER PANELTECHNICAL DETAILS SURFACE MOUNTING TECHNOLOGY ABILITY TO MONITOR ALL WARNINGS REMOTELYREMOTE CONTROL FEATURE OF UP TO 16CONVENTIONAL CONTROL PANELS LED INDICATORS for ALARM and FIRE EVENTS SMPS AND BATTERY INCLUDEDMAINS INPUT VOLTAGEPOWER CONSUMPTIONBATTERYOPERATING TEMPERATUREDIMENSIONSQty PerPackage1230V AC 50 Hz 10W12V 4.5Ah-10 C / 55 C31.5x32.5x11.5 cmPRODUCT CODE: M.U.YAN.00078TELEPHONE CALL MODULE (LANDLINE) Has on-board keypad Can register up to 8 telephone numbers to be calledsequentially during an alarm. Can set the number of redials to be made with theregistered numbers. Can customize call duration, type, etc.PRODUCT CODE: M.U.HAS.00009GSM TELEPHONE CALL MODULE Has on-board keypad Can register up to 9 telephone numbers to be calledsequentially during an alarm. Can set the number of redials to be made with theregistered numbers. Can enter the PIN code of the module’s SIM card. Can customize call duration, type, etc.56PRODUCT CODE: M.U.HAS.00013

addressable fire alarm control panel 2 loop addressable fire alarm control panel 4 loop addressable fire alarm control panel 6 loop addressable fire alarm control panel 8 loop addressable fire alarm control panel product code: m.u.yan.00016 product code: m.u.yan.00018 battery included product code: m.u.yan.00020 product code: m.u.yan.00022

Related Documents:

PSI AP Physics 1 Name_ Multiple Choice 1. Two&sound&sources&S 1∧&S p;Hz&and250&Hz.&Whenwe& esult&is:& (A) great&&&&&(C)&The&same&&&&&

Argilla Almond&David Arrivederci&ragazzi Malle&L. Artemis&Fowl ColferD. Ascoltail&mio&cuore Pitzorno&B. ASSASSINATION Sgardoli&G. Auschwitzero&il&numero&220545 AveyD. di&mare Salgari&E. Avventurain&Egitto Pederiali&G. Avventure&di&storie AA.&VV. Baby&sitter&blues Murail&Marie]Aude Bambini&di&farina FineAnna

The program, which was designed to push sales of Goodyear Aquatred tires, was targeted at sales associates and managers at 900 company-owned stores and service centers, which were divided into two equal groups of nearly identical performance. For every 12 tires they sold, one group received cash rewards and the other received

Alarm 1 is a ‘Sound Once’ alarm, and Alarm 2 is an ‘Everyday’ alarm. Alarm 1 Setting/Alarm 2 Setting Press the ‘Alarm 1’ button (Ref.4) or ‘Alarm 2’ button (Ref.5) to activate alarm settings. ‘OFF’ will begin lashing on the screen. Select Alarm 1 or 2 b

Run Card Requirements Continued Structure Fire goes to 7th Alarm and all 7 Alarm and all 7 Alarms are required. Brush Fire goes to 7th Alarm and all 7 Alarm and all 7 alarms are required. All other incident types can go to 4th Alarm Alarm and minimum of 2nd alarm is required.alarm is required. When a Compan

DETECTION ZONE 11 DETECTION ZONE 12 ALARM ZONE 1 ALARM ZONE 2 ALARM ZONE 3 ALARM ZONE 4 Alarm Zones An alarm zone is clearly defined within the standard but generally is an area of the building coinciding with the fire compartment boundaries. There must be a clear break between these alarm zones to ensure alert and evacuation messages are not .

Extinguishant control system 30. MG-104 series fire extinguishant control panel Marine type LOYD certified fire alarm and extinguishant systems 32. Intelligent analogue addressable fire alarm control systems 33. Conventional fire alarm system and extinguishant system Conventional gas alarm

Engineering Graphics & Design (EGD) NOTE: Information as on 15 November 2020. ENGINEERING GRAPHICS AND DESIGN. GRADE 10 . GRADE 11; GRADE 12 . General drawing principles: Use/care/dangers of drawing instruments, line types, line work, lettering, dimensioning etc. The Grade 10 contentremains applicable. The Grade 10 contentremains applicable. Free-hand drawing. Free-hand drawing techniques. The .