Enclosed DirectOn-Line StartersSpringer Controls carries a complete line of IEC enclosed, direct on-line, AC starters up to 60 HP or 80 amp.Springer Controls is UL certified (508A), to build starters and custom control panels up to 500 HP.(Contact Springer Controls for custom built starters.)Description/Features/Ordering Instructions.2Nomenclature - Part Number.3Single Phase, Full Voltage Starters(9amp - 80amp).4Three Phase, Full Voltage Starters(9amp - 32amp).5Three Phase, Full Voltage Starters(50amp - 80amp).6Wiring Diagrams.7Horsepower Motor Ratings.8Kilowatt Motor Ratings.9

ENCLOSED ON-LINE AC STARTERS; DESCRIPTION & FEATURESDescription and Features Direct On-Line Starters in polycarbonate enclosure.Rated Nema 1, 12, 4 & 4x, IP65 All contactors and overload relays are UL approved. AC3 Inductive Motor rating from 9 amp through 80 amp Fully assembled single and three phase starters. No cover wiring required. Full selection of coil voltages and overload relays. “Start-Stop” or “Reset” external buttons come standard.(Blank cover or no buttons available on request)Part# JC1206P1G-JN 12 amp AC Starter3-phasePoly Enclosure - N4xStart-Stop ButtonsDimensions; 7" x 3½" X 5½"120V AC coilOverload Relay; 8-12 ampsOrdering Information Determine Single or Three Phase application. Determine motor HORSEPOWER or FULL LOAD AMPS (FLA) of the motor. Select complete Part Number from designated table. “Nomenclature” (page B3) to order non-listed or non-standard starters. For AC starters that are NOT direct on-line or custom, see “EngineeredProducts” in Springer’s complete catalog.Part# JC6506P1K-SH 2 / On-Line Starters65 amp AC Starter3-phasePoly Enclosure - N4xStart-Stop ButtonsDimensions; 12" x 10" X 7"240V AC coilOverload Relay; 54-65 ampsSpringer Controls Company 96074 Chester Road, Yulee, FL 32097 (904) 225-0575 Fax: (904) 225-9084 w w w. s p r i n g e rc o n t ro l s . c o m

NOMENCLATURENomenclature; AC StartersExample Part #:#JC0906P1G-JMDescription:9 amp contactor, wired 3 phase, polycarbonate enclosure withstart-stop button, 120volt AC coil, 5.5 - 8.5 current range.J C Ø 96ØP1GJMOverload Relay*(90 amp - 32 amp)Current RangeSuffix2.5 - 4.0K4.0 - 6.3L5.5 - 8.5M8.0 - 12.0NContactor 5050ampJC6565ampJC8080ampButton Configuration10.0 - 16.0P14.5 - 18.0S17.5 - 22.0TPStart-Stop Buttons21.0 - 26.0URReset Button Only25.0 - 32.0VSNo Cover Buttons30.0 - 40.0WOverload Relay*(50 amp - 80 amp)Wiring0Three Phase1Single PhaseCurrent RangeSuffix30 - 43E42 - 55G54 - 65H64 - 82JEnclosure Type6Poly Encl.AC CoilsButton Configuration124VJ120VL208V1Direct-On Line Voltage2Separate Control Power -different VoltageS240V3Terminals for Remote StartN277V4Both #2 and #3U480VEnclosure Size;HxWxDContactors usedG7″ x 3½″ x 5½″JC09, JC12, JC18B7½″ x 4″ x 6″JC25, JC32K12″ x 10″ x 6″JC50, JC65, JC80Springer Controls Company 96074 Chester Road, Yulee, FL 32097 (904) 225-0575 Fax: (904) 225-9084 w w w. s p r i n g e rc o n t ro l s . c o mOn-Line Starters / 3

ENCLOSED AC STARTERS - SINGLE PHASESingle Phase, Full Voltage, Across the Line Starters; 9amp - 80amp9amp Starter; “Reset only” Button9amp Starter; “Start-Stop” ButtonHorsepowerSingle Phase(Full Load JC32JC50JC65JC65JC80CompletePart Number*CompletePart Number*Start-Stop ButtonReset only 4.0 - -SLJC0916R1G-SLOverloadRelay Range(O/L part#)CoilVoltage2.5 - 4.05.5 - -SMJC0916R1G-SM8.0 - G-SNJC0916R1G-SN8.0 - .0 - .0 - .5 1G-SSJC1816R1G-SS17.5 - .0 - .0 - .0 - K-SEJC5016R1K-SE42.0 - 54.0 - .0 - ee “Nomenclature” page 3 for panel size.4 / On-Line StartersPrice 306.00 309.00 309.00 309.00 347.00 347.00 372.00 372.00 416.00 416.00 460.00 774.00 803.00 803.00 913.00Discount Schedule SC-70Springer Controls Company 96074 Chester Road, Yulee, FL 32097 (904) 225-0575 Fax: (904) 225-9084 w w w. s p r i n g e rc o n t ro l s . c o m

ENCLOSED AC STARTERS - THREE PHASEThree Phase, Full Voltage, Across the Line Starters; 9amp - 32ampHorsepowerThree Phase(Full Load )3/4(3.2)ContactorSeriesOverloadRelay Range(O/L part#)JC091.0 - 9JC18JC25JC25JC32JC32*See “Nomenclature” page 3 for panel sizeCoilVoltage115VCompletePart Number*CompletePart Number*Start-StopButtonReset G-UG115V------ 306.001.3 - 1.9(JL1H)230V------460VJC0906P1G-UHJC0906R1G-UG1.8 - P1G-JLJC0906R1G-JL2.5 - 4.0(JL1K)4.0 - 6.3(JL1L) JC0906R1G-UL115VJC0906P1G-JMJC0906R1G-JM5.5 - -UMJC0906R1G-UM8.0 - G-SNJC1206R1G-SN460VJC1206P1G-UNJC1206R1G-UN10.0 - 2506R1B-SU460V------115V------14.5 - 18.0(JL1S)17.5 - 22.0(JL1T)21.0 - 26.0(JL1U)25.0 - 32.0(JL1V)30.0 - 40.0((JL1W)Price 306.00 306.00 309.00 309.00 347.00 372.00 372.00 3206R1B-UW 416.00 460.00 482.00Discount Schedule SC-70Springer Controls Company 96074 Chester Road, Yulee, FL 32097 (904) 225-0575 Fax: (904) 225-9084 w w w. s p r i n g e rc o n t ro l s . c o mOn-Line Starters / 5

Enclosed AC Starter - Three PhaseThree Phase, Full Voltage, Across the Line Starters; 50amp - 80amp*65 amp Starter “Stop-Start”HorsepowerThree Phase(Full Load -40(52.0)CompletePart Number*CompletePart Number*Start-StopButtonReset onlyButtonContactorSeriesOverloadRelay Range(O/L part#)CoilVoltage30 - 0VJC5006P1K-UGJC5006R1K-UG54 - ------64 - JC8006P1K-UJJC8006R1K-UJ64 - 0)JC80JC6542 - 55(JL2G)Price 774.00 774.00 803.00 913.00 913.00*Contact Springer Controls for starters larger than 80amp or for any custom built starters.Discount Schedule SC-706 / On-Line StartersSpringer Controls Company 96074 Chester Road, Yulee, FL 32097 (904) 225-0575 Fax: (904) 225-9084 w w w. s p r i n g e rc o n t ro l s . c o m

WIRE DIAGRAMSTypical Wiring Diagram “JC” SeriesThree Phase StarterSingle Phase StarterReset Only - The Start Holding Circuit isremoved and the motor will start as soonas power is applied.Overload contact 95-96 remains in thecontrol circuit.Note:Wire L1 & L2 control supply voltage only when coil voltage is the same as the line voltage.Functions of Overload RelayManual RESET(Operator must manually reset O/L relay when tripped)*Manual RESET and STOP(Operator must manually reset O/L relay when tripped.STOP can also be initiated by pushing the reset buttonwhich interrupts the holding circuit)Automatic RESET and STOP(After tripping, O/L relay will automatically turn on when propertemperature is met. STOP can also be initiated by pushing thereset button which interrupts the holding circuit.)Automatic RESET no STOP(After tripping, O/L relay will automatically turn on whenproper temperature is met.)* Recommended settingSpringer Controls Company 96074 Chester Road, Yulee, FL 32097 (904) 225-0575 Fax: (904) 225-9084 w w w. s p r i n g e rc o n t ro l s . c o mOn-Line Starters / 7

HORSEPOWER MOTOR RATINGSFull-Load Motor-Running Currents in AmperesCorresponding to Various AC Horsepower Motor RatingsThe table below provides the average full-load currents of squirrel cage motors in accordance with IEC conventions. These are given only as a guide. Refer to theactual motor nameplate for full-load current values.110V - 120V220V - 240V ¹,²380V - 415V440V - 480V550V - 600V2.3 KV4.16 0---590.0---472.0118.65.Notes:1. To obtain F.L.C. for 200 and 208 volt motors multiply 230 volts values by 1.15 and 1.10 respectively.2. To obtain F.L.C. for 265 and 277 volt motors multiply 230 volts values by .87 and .83 respectively.8 / On-Line StartersSpringer Controls Company 96074 Chester Road, Yulee, FL 32097 (904) 225-0575 Fax: (904) 225-9084 w w w. s p r i n g e rc o n t ro l s . c o m

KILOWATT MOTOR RATINGSThe table below provides the average full-load currents of squirrel cage motors in accordance with IEC conventions. These are given onlyas a guide. Refer to the actual motor nameplate for full-load current values.Single-Phase MotorThree-Phase Springer Controls Company 96074 Chester Road, Yulee, FL 32097 (904) 225-0575 Fax: (904) 225-9084 w w w. s p r i n g e rc o n t ro l s . c o mOn-Line Starters / 9

Welcome to the Springer Controls Company, Inc. Product Guideto the Enclosed Direct On-Line Starters This section reflectsour continuing commitment to our customers to provide complete,up-to-date product information and technical data. We appreciateyour choosing Springer Controls and we will continue to update thisinformation as well as provide new products to meet today’s demandsfor electrical control products.Control StationsPower SwitchingDevicesRotary Gear LimitSwitchesPendant ControlStationwww.springercontrols.comVisit our site, it includes new product information, complete productdata with downloads, installation instructions, along with other SpringerControl news.96074 Chester Road --- Yulee, Florida, 32097Phone: (904) 225-0575 --- Fax: (904) 225-9084

Springer Controls Compan 96074 Cester oad, ulee, L 32097 (904) 225-0575 a (904) 225-9084 www.springercontrols.com On-Line Starters / 3 NOMENCLATURE J C Ø 9 Ø 6 P 1 G J M Nomenclature; AC Starters

Related Documents:

Individual Branch Circuit Wiring Motor Starters Across the Line Starting of Induction Motors Magnetic Starters Reduced Voltage Starters Primary Resistance Starters Autotransformer Starters Wye-Delta Starting Part Winding Starters Reading a LEESON Model Number Reading a Lincoln Motors Model Number Major Motor Components VI.

Cambridge Young Learners English Tests Starters Page 11 Starters Reading & Writing. Page 12 Starters Starters Reading & Writing Cambridge Young Learners English Tests 3 2 This is a bike. 3 This is a pineapple. 4 This is a television. 5 This is a guitar. Part 1 – 5 questions – 2 Look and read. Put a tick or a cross in the box. There are two examples. Examples This is a flower. This is a .

SPEEDFAX YET Remove IP20 info Added software to pg . Revised on 01/06/20. 7/2 Smart Infrastructure, Industrial Control Catalog 2021 7 SOFT STARTERS Soft Starters Introduction 6/2 Siemens IC 10 · 2020 Switching Devices – Soft Starters and Solid-State Switching Devices Introduction 6 . Industrial Control Catalog 2021 7/3 7 SOFT STARTERS .

Magnetic Line Starters – 3 Pole, 3 Phase, Single Speed Non Reversing 600 VAC Max, 60Hz Square D or Cutler-Hammer motor starters available as standard. For Cutler-Hammer only, heaters not included. See page S9 to order. Line Starter Combination Starter FEATURES-SPECIFICATIONS B7 MAGNETIC LINE STARTERS NEMA

Magnetic Line Starters – 3 Pole, 3 Phase, Single Speed Non Reversing 600 VAC Max, 60Hz Square D or Cutler-Hammer motor starters available as standard. For Cutler-Hammer only, heaters not included. See page S9 to order. Line Starter Combination Starter FEATURES-SPECIFICATIONS B7 MAGNETIC LINE STARTERS NEMA

Selection: Refer Table 1 for recommended selection of DOL Starters and Table 2 for ASD Starters. DOL and ASD Starters are supplied without relays. Relays are to be fitted at site. Select the suitable range of relay as per recommendation given in Table 1 and 2. Select back-up fuse rating for different starters from the selection .

English for Starters is a communicative course in English, which takes into account the most modern methodology. English for Starters Level 8 aims to stimulate the child’s interest in learning English and to develop confidence through a range of enjoyable activities. The focus at this stage of the course is on all four skills – listening,

Advanced Engineering Mathematics Dr. Elisabeth Brown c 2019 1. Mathematics 2of37 Fundamentals of Engineering (FE) Other Disciplines Computer-Based Test (CBT) Exam Specifications. Mathematics 3of37 1. What is the value of x in the equation given by log 3 2x 4 log 3 x2 1? (a) 10 (b) 1(c)3(d)5 E. Brown . Mathematics 4of37 2. Consider the sets X and Y given by X {5, 7,9} and Y { ,} and the .