SITRANS F M MAGFLO - CINDTECHS

2y ago
17 Views
2 Downloads
8.77 MB
76 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Fiona Harless
Transcription

sHandbookEdition 08/2005 - Revision 04SITRANS F M MAGFLO Electromagnetic flowmetersSensor types MAG 1100, MAG 3100, MAG 5100 WTransmitter types MAG 5000, MAG 6000[Technical Documentation (handbooks, instructions, manuals etc.) on the complete productrange SITRANS F can be found on the internet/intranet on the following links:English: 00Order no.: FDK-521H0879SFIDK.PS.027.W4.22]

SITRANS F M MAGFLO Siemens Flow Instrumentsrange of electromagneticflowmetersMAG 1100Size [inch]ConnectionPressure [psi]1/12" -MAG 1100FOOD3/4"Flangeless(Wafer)8"- 4"Weld-in adapter,clamp adapter,thread adapter1/2"- 78"FlangeMAG 3100 WMAG 5100 W1" - 48"1" - 48"FlangeFlange60060015006006000 to 400 20 to 300 40 to 350 20 to 200 20 to 160LinerZirconium oxide(Zr02)Ceramic (Al2 O3)PFACeramic (Al2 O3)PFANeoprene, EPDM,Teflon (PTFE),Ebonite,Linatex Neoprene andEPDM1" - 1½" &14" - 48"hard elastomer2" - 12"composite elastomerElectrodesPlatinumHastelloy C276PlatinumHastelloyAISI 316 Ti,Hastelloy C,Platinum/Iridium,Titanium,Tantalum,PE electrodesAISI 316 Ti,PE electrodesAISI 316 Ti,PE electrodesTemperature [ F]EnclosureNEMA 4X & NEMA 6Ex-versionEEx [ia] [ib] IIB T4-T6Houzandous areaintrinsically safeEEx e ia IIC T3-T6EEx d [ia] [ib] IIB T4-T6intrinsically safeApprovalsFM Class 1, division 2,WRc, NSFWRc, NSFMAG 5000MAG 6000Outputs1 current output1digital output1 relay output1 current output1digital output1 relay outputFlow cationOptionalHART Add-on modulesHART , DeviceNet, Profibus DP,Profibus PA, CANopen3 lines20 characters(optional without display)3 lines20 characters(optional without display)Display 0,5% o.r. 0,25% o.r.NEMA 2, NEMA 4X, NEMA 6NEMA 2, NEMA 4X, NEMA 6Custody transferapprovalPTB(cold water)PTBOIML R75OIML R117Ex-versionSafety barrier 19"[EEx ia] IIC[EEx ia ib] IIB[EEx ia] IIC12-24 V AC/DC115-230 V AC12-24 V AC/DC115-230 V ACMeter uncertaintyEnclosurePower supplyBatchApprovalsRefer to2MAG 3100NoYesULc general purposeFM Class 1, division 2ULc general purposeFM Class 1, division 2MAG 6000 IndustryMAG 8000 WOperating manualSFIDK.PS.026.E1.02Operating manualSFIDK.PS.026.D2.02

SITRANS F M MAGFLO Contents1. Product introduction1.11.2Product introduction . 4Mode of operation . 52. .72.8.12.8.22.92.10Sensor MAG 1100 and MAG 1100 Ex . 6Sensor MAG 1100 FOOD . 7Sensor MAG 3100, MAG 3100 Ex and MAG 3100 W . 8-9Sensor MAG 5100 W - updated 2005.10.21 . 10Transmitter MAG 5000 (1/4" to 48") - updated 2005.06.13 . 11Transmitter MAG 6000 (1/4" to 78") - updated 2005.06.13 . 12Safety barrier (ia/ib) for sizes up to 12'’ . 13Cleaning unit . 13Meter uncertainty - updated 2006.03.15 . 14Output characteristics MAG 5000 and MAG 6000 . 15Sensor cables and conductivity of medium . 16Minimum accept data for cable . 16HART communication add-on module . 16Cable specifications (Supplied by Siemens Flow Instruments) . 163. Product selection guidelines3.13.2.13.2.23.2.33.33.43.53.63.7Sizing table (1/12" to 78") . 17Minimum conductivity . 18Liner selection guide . 18Electrode selection guide . 18Installation conditions . 18-21Cleaning unit . 22Custody transfer approval . 23Transmitter 5000 CT, MAG 6000 CT Sealing . 23Ex installations . 244. Dimensions and weight4.14.24.34.44.5Sensor MAG 1100 . 25Sensor MAG 1100 FOOD . 26-27Sensor MAG 5100 W - updated 2006.03.15 . 28-29Sensor MAG 3100 and MAG 3100 W . 30-31Transmitter . 31-335. Installation of sensor5.15.25.3Potential equalization (Grounding) . 34Inlet protection MAG 3100 . 35Cathodic protected piping . 356. Installation of .2.86.36.4Integral mount installation MAG 5000 and MAG 6000 . 36-37Add-on modules (MAG 6000 only) . 38Remote installation (Sensor end) . 38Remote installation (Wall mount) . 39-40Remote installation (Rack mount) . 41Add-on modules (MAG 6000 only) . 42Installation using wall mounting kit . 43Installation using front of panel mounting kit . 44Installation using back of panel mounting kit . 45Transmitter with safety barrier . 46Transmitter with cleaning unit . 477. Electrical 77.2.8Transmitter MAG 5000 and MAG 6000 connection diagram . 48Wiring diagram for transmitter and sensor . 49Integral installation . 49Remote installation wall mount NEMA 6 enclosure . 49Rack mount NEMA 2 enclosure . 50Wall mount NEMA 4X enclosure . 50Rack mount with safety barrier NEMA 2 EEx (ia/ib) up to 12'' . 50Wall mount with safety barrier NEMA 6 EEx (ia/ib) up to 12'' . 51Rack mount NEMA 2 with cleaning unit . 51Wall mount NEMA 6 with cleaning unit . 518. Start-up & ad and display layout . 52Menu build-up . 53Password . 53MAG 5000 and MAG 6000 menu overview . 54MAG 5000 CT and MAG 6000 CT menu overview . 55Basic settings . 56Outputs . 57Digital and relay outputs . 57Relay output . 58External input . 58Sensor characteristics . 59Reset mode . 59Service mode . 60Operator menu setup . 61Product identity (read only) . 62Change password . 62Language mode . 63HART communication MAG 5000 HART or as add-on module . 63Flow rate . 64Totalizer . 64Batch . 64Factory settings/available settings . 65Dimension dependent factory settings MAG 5000 and MAG 6000 . 66Dimension dependent batch and pulse output settings . 66MAG 6000 CT settings . 67Error handling . 68List of error numbers . 699. Service9.19.29.39.4Transmitter check list . 70Trouble shooting MAG 5000 and MAG 6000 . 71Check list MAG sensor . 72Coil resistance table . 7310. Ordering10.Please look on our homepage http://www.siemens.com/flow under "Product Selector" . 743

SITRANS F M MAGFLO 1. Product introduction1.1Product introductionSITRANS F M MAGFLO electromagnetic flowmeters offer reliable, precise and inexpensiveflow measurement on all electrically conductive liquids. Typical applications are found in allindustries. E.g.: Water sector:Food sector:Chemical sector:Other sectors:Potable water, treatment of chemicals, waste water and sludge.Dairy products, beer, wine, soft-drinks and fruit juices.Detergents, pharmaceuticals, acids and alkalies.HVAC, paper pulp and mining slurries.SITRANS F M MAGFLO electromagnetic flowmeters are characterised by simplicity: SimpleSimpleSimpleSimpleto installto commissionto operateto maintainSITRANS F M MAGFLO electromagnetic flowmeters are manufactured by Siemens FlowInstruments - one of the worlds leading makers of flowmeters.All SITRANS F M MAGFLO electromagnetic flowmeters feature a unique SENSORPROM memory unit which stores sensor calibration data and transmitter settings for the lifetime of theproduct.At commissioning the flowmeter commencesmeasurement without any initial programming.The factory settings matching the sensor are storedin the SENSORPROM unit. Also customer specifiedsettings are downloaded to the SENSORPROM unit. Should the transmitter be replaced, the newtransmitter will upload all previous settings andresume measurement without any need for reprogramming.Furthermore, the "fingerprint" used in connectionwith the Siemens Flow Instruments Verificator isstored during the sensor calibration.The Siemens Flow Instruments Verificator can verifythe accuracy of the flowmeter while still installedyears after the initial calibration.USM II "Plug & Play" add-on communication modules.USM II - the Universal Signal Module with "Plug &Play" simplicity makes it easy to access andintegrate the flow measurement with almost anysystem. It ensures the flowmeter will be easy toupgrade to new communication platforms in thefuture, too.4

SITRANS F M MAGFLO 1. Product introduction1.2Mode of operationThe flow measuring principle is based on Faraday’s law of electromagnetic induction. The flowmeterconsists of a sensor type MAG 1100, 3100 or 5100 W and a transmitter type MAG 5000 or 6000.Ui When an electrical conductor of length L is moved at velocity v, perpendicular to the lines offlux through a magnetic field of strength B, the voltage Ui is induced at the ends of the conductorUi L x B x vUiLBvk Induced voltageConductor length Inner pipe diameter k1Magnetic field strength k2Velocity of conductor (media)k1 x k2Ui k x v, the electrode signal is directly proportional to the fluid velocitySENSOR (Flow tube)The sensor converts the flow into an electrical voltage (Ui) proportional to the velocity of the flow.The sensor is built up of a stainless steel pipe, 2 coils, electrodes, an isolating liner, housing andwhere applicable, connecting flanges.TRANSMITTERThe transmitter consists of a number of function blocks which convert the sensor voltage into flowreadings.Power supply2 different types of power supply are available. A 12 - 24 V AC/DC and a 115 - 230 V AC switch modetype.Coil current module generates a pulsating magnetizing current that drives the coils in the sensor.The current is permanently monitored and corrected. Errors or cable faults are registered by the selfmonitoring circuit.Input circuit amplifies the flow proportional signal from the electrodes. The input impedance isextremely high: 1014 Ω which allows flow measurements on fluids with conductivities as low as1 mS/cm. Measuring errors due to cable capacitance are eliminated due to active cable screening.Digital signal processor converts the analog flow signal to a digital signal and suppresseselectrode noise through a digital filter. Inaccuracies in the transmitter as a result of long-term driftand temperature drift are monitored and continuously compensated for via the self-monitoringcircuit. The analog to digital conversion takes place in an ultra low noise ASIC with 23 bit signalresolution. This has eliminated the need for range switching. The dynamic range of the transmitteris therefore unsurpassed with a turn down ratio of minimum 3000:1.CAN communicationThe transmitter operates internal via an internal CAN communication bus. Signals are transferredto/from a signal conditioner to the display module, internal/external option modules and the dialogmodule.Dialog moduleThe display unit consists of a 3-line display and a 6-key keypad. The display shows a flow rate ora totalizer value as a primary reading.Output module converts flow data to an analog, a digital and a relay output. The outputs aregalvanically isolated and can be individually set to suit a particular application.5

SITRANS F M MAGFLO 2. SpecificationsMAG 1100 and MAG 1100 Ex2. Specifications2.1 Sensor MAG 1100 and MAG 1100 ExSpecificationsMAG 1100 CeramicMAG 1100 ExMAG 1100 PFATypeFlangeless sensor (Wafer)Nominal rating pressure1/ 4"-21/ 2":VacuumTemperature ofCeramic1", 11/2", 2", 3", 4"1", 11/2", 2", 3", 4"1/4"-21/2":300 psi600 psi, 3": 560 psi,4": 450 psi1.5 10-5 psi0.3 psi1.5 10-5 psi 20 F to 265 F 5 F to 250 F0 F to 300 F0 F to 400 F (1/4" - 4")Suitable for steam sterilization at 300 FTemperature shock(Duration 1 min.):Max. 210 F momentarily(Ceramic liner)1/ 12", 1/8":High temperature version1/4", 3/8", 1/2",600 psi, 3": 560 psi,4": 450 psiPFAmedium3/8", 1/2",(Duration 1 min.):Max. T 68 F/min.1/ 4",3/ 8",1/2",1": Max. T 60 F/min.1/12", 1/8":Max. T 68 F/min.Max. T 60 F/min.11/2", 2", 21/2": Max. T 50 F/min.11/2", 2", 21/2" : Max. T 50 F/min.1/4",3/8",1/2",1":3", 4" : Max. T 40 F/min.3", 4" : Max. T 40 F/min.(Duration 1 min., followed by 10 min. rest):(Duration 1 min., followed by 10 min. rest):1/ 12", 1/8":Max. T 210 F/min.1/ 4", 3/ 8", 1/2",11/2",2",1/12", 1/ 8":1": Max. T 175 F21/2":Max. T 210 F/min.1/4", 3/8", 1/ 2",Max. T 160 F11/2",3", 4": Max. T 140 F2",1": Max. T 175 F21/2":Max. T 160 F3", 4": Max. T 140 FRemote mount transmitter: 40 F to 210 FAmbient temperatureIntegral mount transmitter: 5 F to 120 FLiner1/12", 1/8"1/ 4 "Electrodes- 4"1/12", 1/8"1/4" - 4"EnclosureTerminal box(Remote installation only)StandardHigh temp.Studs & nutsZirconium oxide ZrO2Aluminum oxide Al2O3 (ceramics)Reinforced PFA (Teflon)Platinum sinteredOptionStandardHastelloy C-276Platinum with gold/titanium brazingalloyStainless steel AISI 316L (1.4404)Stainless steel AISI 316 (1.4404)Stainless steel AISI 316L (1.4404)Fiberglass-reinforced polyamideFiberglass-reinforced polyamideStainless steel AISI 316L (1.4436)Stainless steel AISI 316 (1.4436)Stainless steel AISI 316L (1.4436)Stainless steel AISI 304 (1.4301)Number and size to DIN 2501Number and size to DIN 2501DIN 2501 (150-600 psi), ANSI B16.5, class 150 and 300 or equivalentTo DIN 2501 (150-600 psi),ANSI B16.5,class 150 and 300 or equivalent1/ 12"- 3/8'': 1/2'' NPT threaded adaptorEPDM (max. 300 F, 600 psi)EPDM (max. 300 F, 600 psi)OptionGraphite (max. 390 F, 600 psi)Graphite (max. 390 F, 600 psi)OptionPTFE (max. 210 F, 300 psi)PTFE (max. 265 F, 300 psi)Cable entriesEnclosure ratingAluminum oxide Al2O3 (ceramics)Platinum sinteredPlatinum with gold/titanium brazingalloyStainless steel AISI 304 (1.4301)Mating flangesGasketsZirconium oxide ZrO24 pcs. PG 13.5StandardNEMA 4X / 6 (3 ft. submersion for 30 min)OptionMechanical load (vibration)NEMA 6P (30 ft. continuous submersion)18-1000 Hz random, 3.17 G rms in all directions to EN 60068-2-3618-1000 Hz random in all directionsto EN 60068-2-36Sensor: 3.17 G/Integral mount Ex-d: 1.14 GTest pressure1200 psi (2 nominal)600 psi (2 nominal)Ex approvalsEEx [ia/ib] IIB T4-T6/DEMKO, No. 97D.121909XExcitation frequency1/ 12"programmable3", 4": 7.5 Hz61200 psi (2 nominal)- 21/2": 15 Hz3/ 8 "- 21/2": 15 Hz3", 4": 7.5 Hz1/ 4 "- 21/2": 6.25 Hz3", 4": 3.125 Hz

SITRANS F M MAGFLO 2. SpecificationsMAG 1100 FOOD2.2 Sensor MAG 1100 FOODTypeNominal sizeProcess connectionOperating pressureVacuumTemperature of mediumTemperature shockAmbient temperatureLinerElectrodesEnclosureTerminal box(Remote installation only)StandardOptionCable entriesEnclosure ratingStandardOptionMechanical load (vibration)Test pressureApprovalsExcitation frequencyprogrammableAccessoriesMAG 1100 FOODMAG 1100 FOOD PFASpecificationsMAG 1100 FOODHygienic sensor1", 11/2", 2", 3", 4"Hygienic adapters available for: Direct welding in Clamp fitting Threaded fitting3/8"-21/2": 600 psi, 3": 560 psi, 4": 450 psi300 psi1.5 10-5 psi0.3 psi0 F to 300 F 20 F to 270 FSuitable for steam sterilizationSuitable for steam sterilization at 300 F(Duration 1 min.):Max. 212 F momentarily3/ ", 1/ ", 1"Max. T 60 F/min.8211/2", 2", 2 1/2"Max. T 50 F/min.3", 4"Max. T 40 F/min.(Duration 1 min., followed by 10 min. rest):3/8", 1/2", 1"Max. T 175 F11/2", 2", 2 1/2"Max. T 160 F3", 4"Max. T 140 FRemote mount transmitter: 40 F to 210 FRemote mount transmitter: 40 F to 210 FIntegral mount transmitter: 5 F to 120 FIntegral mount transmitter: 5 F to 120 FAluminum oxide Al2O3 (ceramic)Reinforced PFA (Teflon)Platinum with gold/titanium brazing alloyHastelloy C-276Stainless steel AISI 316L (1.4404)Stainless steel AISI 316L (1.4404)Fiberglass-reinforced polyamideFiberglass-reinforced polyamideStainless steel AISI 316 (1.4436)Stainless steel AISI 316 (1.4436)4 pcs. PG 13.54 pcs. PG 13.5NEMA 4X / 6 (3 ft. submersion for 30 min)NEMA 4X / 6 (3 ft. submersion for 30 min)NEMA 6P (30 ft. continuous submersion)NEMA 6P (30 ft. continuous submersion)18-1000 Hz random, 3.17 G rms in all directions,18-1000 Hz random, 3.17 G rms in all directions,to EN 60068-2-36to EN 60068-2-361200 psi (2 nominal)600 psi (2 nominal)3A, EHEDG3A3/8" - 21/2": 15 Hz3/8" - 2 1/2": 15 Hz3", 4": 7.5 Hz3", 4": 7.5 Hz3/8", 1/2",AdaptersPipe connection/OperatingpressureGasket StandardOptionMaterialStainless steel AISI 316Adapter for direct welding into pipe:Tri-Clover ISO 2037, DIN 11850, SMS 3008, BS 4825-11/ ", 3/ ", 1", 11/ ", 2", 3"2424"Clamp adapter:Tri-Clamp ISO 2852, DIN 32676, SMS 3016, BS 4825-31/ ", 3/ ", 1", 11/ ", 2"24221/2", 3", 4"Thread adapter:3/ ", 1/ ", 1", 11/ "DIN 11851:8222", 21/2", 3", 4"3/ ", 1/ ", 1", 11/ ", 2", 3", 4"ISO 2853, SS 3351, BS 4825-4:822SMS 1145:1", 11/2", 2", 21/2", 3"Pressure600 psi350 psi200 psi150 psi600 psi350 psi200 psi80 psiEPDM (ethylene, propylene rubber) ( 5 F to 300 F)NBR (nitrile butadiene rubber) ( 5 F to 210 F)Stainless steel AISI 304, ISO 2852NoteIt is always a system so please state system max. pressure and not MAG 1100 or adapter.7

SITRANS F M MAGFLO 2. SpecificationsMAG 3100, MAG 3100 Ex and MAG 3100 W2.3 Sensor MAG 3100, MAG 3100 Ex and MAG 3100 WSpecificationsMAG 3100TypeNominal sizeTemperature of mediumLiner:Neoprene (standard)EPDM1)Linatex rubberEbonite 1)PTFEPTFE high temperatureAmbient temperatureRemote mount transmitterIntegral mount transmitterOperating pressure3) [abs.psi]]Liner:NeopreneEPDMNatural rubber & Linatex EbonitePTFE teflon:1/2" - 24"1/ " - 12"2Excitation frequencySensor with flanges1/ " - 78"230 to 160 F 20 to 200 F 40 to 160 F2)30 to 200 F0 to 210 F0 to 350 F (remote only)MAG 3100 ExSensor with flanges1/ " - 12"2Temperature classificationT3 T4T5T630 to 160 F 30 to 160 F 30 to 160 F 20 to 200 F 20 to 190 F 20 to 170 F0 to 160 F 0 to 160 F 0 to 160 F30 to 200 F 30 to 190 F 30 to 170 F0 to 210 F 0 to 190 F 0 to 170 F 40 F to 210 F0 F to 120 F0.150.150.150.15totototo1500 psi600 psi600 psi1500 psi0 F to 105 F0 F to 105 F0.150.150.150.15totototo1500 psi600 psi600 psi1500 psiEnclosure rating StandardOptionCable entriesMechanical loadTest pressureMax. 210 F: 4.5 to 750 psi4.5 to 600 psiMax. 350 F: 9.0 to 750 psi1/ " - 21/ ": 15 Hz1/ " - 21/ ": 7.5 Hz22223" - 6": 7.5 Hz3"/4": 3.75 Hz8" - 48": 3.75 Hz5" - 12": 1.875 Hz54" - 78": 1.875 Hz14" - 48": 3.75 HzNEMA 4X / 6 (3 ft. submersion for 30 min)NEMA 6P (30 ft. continuous submersion)4 pcs. PG 13.5 - 2 others available18-1000 Hz random, 3.17 G rms in all directions, to EN 60068-2-361.5 nominal pressureApprovalsFM Class 1, division 21)MAG 3100 WSensor with flanges1" - 48"30 to 160 F 20 to 200 F 40 F to 210 F0 F to 120 F0.15 to 600 psi0.15 to 600 psiAll sizes: 3.75 HzWith WRAS drinking water approval, approved to BS 6920 by WRC (Water Research Council, UK) and NSFFor temperature below 5 F AISI 304 or 316 flanges must be used3 ) Maximum operating pressure decreases with increasing operating temperature and with stainless steel flanges2)8

SITRANS F M MAGFLO 2. SpecificationsMAG 3100, MAG 3100 Ex and MAG 3100 W2.3 Sensor MAG 3100, MAG 3100 Ex and MAG 3100 W (continued)FlangesStandardEN 1092-1:20011)Rased faceOptionANSI B 16.5( BS 1560)AS 2129AS 4087AWWA C-207ElectrodesStandardOptionGrounding electrodesStandardMeasuring pipe StandardOptionFlange andStandardhousing materialOption1)MAG 3100 ExDN 15-50:600 psiDN 65-150:200 psiDN 200-1000:150 psiDN 1100 -2000:80 psiDN 65-1000:80 psiDN 1200-2000:150 psiDN 200-2000:200 psiDN 200-600:350 psiDN 65-600:600 psiDN 50-400945 psi (DIN 2636)DN 25-350150 psi (DIN 2637)3/4"-24": Class 150 (290 psi)3/4"-24": Class 300 (725 psi)3/4"-48": Table D (100 psi) / E (200 psi)Class 14 (DN 50-1200, 200 psi)Class 21 (DN 50-600, 300 psi)Class 35 (DN 50-600, 500 psi)28"-78": Class D (145 psi)AISI 316 Ti (1.4571)Hastelloy C-276, Platinum / Iridium, Titanium,AISI 316 Ti Ceramic Coated, TantalumAs measuring electrodes (except PTFE)AISI 304 (1.4301)AISI 316L (1.4436)Carbon steelCorrosion-resistant two-component coating (min. 150 µm)OptionColorEx

SITRANS F M MAGFLO Electromagnetic flowmeters Sensor types MAG 1100, MAG 3100, MAG 5100 W Transmitter types MAG 5000, MAG 6000 Handbook Edition 08/2005 - Revision 04 Order no.: FDK-521H0879 SFIDK.PS.027.W4.22 s [ ] Technical Documentation (handb

Related Documents:

SITRANS F flowmeters SITRANS F M MAGFLO MAG 5100 W Siemens FI 01 · 2007 4/57 4 Overview The SITRANS F M MAGFLO MAG 5100 W is an electromagnetic flow sensor designed to meet ground water, drinking water, waste water, sewage or sludge applications. Benefits DN 25 to DN 1200 (1” to

sitrans f SITRANS F M MAGFLO Elektromagnetiska flödesmätare Upplev Siemens-lösningen s. Det som gör MAGFLO . Transmitter MAG 5000 MAG 6000 MAG 6000 I MAG 6000 I (Ex d) . FM Class 1, Div 2 FM Class 1,

SITRANS F flowmeters SITRANS F M MAGFLO MAG 1100 Food Siemens FI 01 · 2008 4/51 4 MAG 5000/6000 transmitters and sensors are packed in sepa-rate boxes, the final assembly takes place during installation at

ciated transmitter MAG 5000, 6000 and 6000 I. . FM Class 1 Div 2 CSA Class 1, Div 2 1) Larger sizes on request 2) Conditions are also dependent on liner characteristiques 3) Sealing O-ring in Viton. SITRANS F flowmeters SITRANS F M MAGFLO MAG 3100/3100 Ex Siemens FI 01 · 2007 4/67 4

sitrans f sitrans f m magflo mag 5100 w siemens fi 01 · 2007 3/59 3 mag 5100 w 1) dn 300 6 " 6 25 , 40 300

Instrumentos para medida de caudal SITRANS F SITRANS F M MAGFLO MAG 5100 W Siemens FI 01 · 2005 4/55 4 - no disponible Con transmisor MAG 5000 ó MAG 6000 montado, el peso aumenta unos 0,8 kg (1.8 lbs), co

SITRANS F flowmeters SITRANS F Product overview 4/2 Siemens FI 01 · 2005 4 Overview Application Description Catalog page Software for parameterization SITRANS F M electromagnetic flowmeters Choose MAG 5000/6000 for more demanding applications where you need the benefits of highly func-tional, accura

ASME A17.1, 2013 NFPA 13, 2013 NFPA 72, 2013 Not a whole lot has changed in the sub-standards. Substantial requirements in the IBC/IFC. International Building Code (IBC) and International Fire Code (IFC) “General” Requirements. Hoistway Enclosures Built as “shafts” using fire barrier construction o 1 hr for 4 stories o 2 hr for 4 or more stories o Additional .