SITRANS F Flowmeters SITRANS F - Jadan

2y ago
17 Views
2 Downloads
531.53 KB
6 Pages
Last View : 1d ago
Last Download : 3m ago
Upload by : Axel Lin
Transcription

SITRANS F flowmetersSITRANS FProduct overview OverviewApplicationDescriptionCatalogpageSoftware forparameterizationSITRANS F M electromagnetic flowmetersChoose MAG 5000/6000 for moreTransmitter MAGFLO MAG 5000/6000 4/19demanding applications where you Superior signal resolution for optimumneed the benefits of highly functurn down ratiotional, accurate performance. Comprehensive self-diagnostic, for error indication and logging Multi-lingual display and keypad interface Custody transfer approval: PTB, OIMLR75, OIML R117 and OIML R49SIMATIC PDMMAG 6000 I and MAG 6000 I Ex d Transmitter MAGFLO MAG4/30in robust die-cast aluminium enclo- 6000 I/6000 I Ex dsure for demanding applications Remote and compact mounting on alland where explosion proof protecsensorstion is necessary. Explosion proof design: ATEX and FM Multi-lingual display and touchpad keypad Comprehensive self-diagnosticsSIMATIC PDM4Designed for the general industryFlow sensors MAGFLO MAG 11004/33environment. The obstructionless Metering tube DN 6 to DN100 flangeperformance of the MAG 1100 isless design.unaffected by the suspended solids, viscosity and temperature chal- Corrosion resistant AISI 316 stainlesssteel housing.lenges. Highly resistant liner and electrodes fitting most extreme process media. Temperature rating up to 200 C(390 F) ATEX approval4/2Siemens FI 01 · 2005Specially designed for the food &beverage industry.Flow sensors MAGFLO MAG1100 Food AISI 316 stainless steel enclosure Hygienic seal, 3A and EHEDG-approved construction Easy to clean Supplied with connections accordingto your specification4/40The MAG 5100 W with its patentedcomposite elastomer lining is suitable for all water applications.Flow sensors MAGFLO MAG 5100 W 4/51 Hard elastomer rubber lined bore. Metering tube DN 25 . 1200(1" . 48") Integral grounding electrodes as standard Increased low flow accuracy for waterleak detection Drinking water approvals and OIMLR49

SITRANS F flowmetersSITRANS FProduct overviewApplicationDescriptionCatalogpageSoftware forparameterizationThe MAG 3100 W comes with either Flow sensors MAGFLO MAG 3100 W 4/58Neoprene or EPDM linings and Metering tube DN 25 . DN 1200AISI 316 Ti electrodes and is(1” . 48”)designed for water applications. Metering tube EPDM or Neoprene Integral grounding electrodes as standardThe MAG 3100 series with its flexibility in the choice of linings, electrodes and flange material allowsthe measurement of even the mostextreme process media.Designed for heavy-duty applicaTransmitter Transmag 24/75tions like pulp & paper stock over Magnetic flowmeter with a very strong3%; heavy mining slurries and minpulsed AC magnetic fielding slurries with magnetic particles. PROFIBUS PA or HART communication Self-test functionApplication in connection withtransmitter Transmag 24Flow sensors MAGFLO MAG4/633100/3100 Ex For a wide range of pipe dimensions:DN 15 . DN 2000 (½” . 78”) Wide range of liner and electrode materials High temperature sensor for application with temperatures up to 180 C(355 F) Approved according to PTB,OIML R75, OIML R117 and ATEXSIMATIC PDMFlow sensor 911/E4/80 Metering tube: DN 15 to 600 (½" to 24") Metering tube liner: rubber, PTFE, Novolak Integral smartPLUG for saving of calibration values Temperature of medium:-20 . 150 C (-4 . 300 F)Measurement of flow of electrically Flow sensor 911/F54/86conducting liquids in connection Ceramic metering tube: DN 2 DN 12with Transmag 2.(0.078" . 0.47")Smallest measuring range: 0 to 3 l/h Various process connections available(0 to 0.013 USgpm). Integral smartPLUG for saving of calibration values Temperature of medium:-20 . 150 C (-4 . 302 F)Battery operated water meter forwater applications within abstraction, distribution network, revenuemetering and irrigation.Water meter MAG 8000W4/90 Battery operated water meter Metering tube DN 50 . 300 (2" . 12")Siemens FI 01 · 20054/3

SITRANS F flowmetersSITRANS FProduct nt of liquids and gasses. Measurement of mass flow,density, temperature and fractione.g. Brix or Plato.Flow sensors MASSFLO MASS 2100 4/124(Single tube design) DI1.5, DI3, DI6, DI15, DI25 and DI40 Flow from 0.1.52,000 kg/h Pipe material: 1.4435 (316 L); 2.4602Hastelloy C-22 Accuracy typically 0.1% of flow rate0.0005 g/cm3 and 0.5 C Liquid temp./pressure: -50 . 180 C /Up to 410 bar Approved according to ATEX EEx ia IICT3.T6Measurement of liquids and gasses. Measurement of mass flow,density, temperature and fractione.g. Brix or Plato.4/138Flow sensor MASSFLO MC1(Dual tube design) DN50, DN65, DN80 and DN100 Flow from 0.192,000 kg/h Pipe material 1.4571 (316 Ti); HastelloyC4 Accuracy typically 0.15% of rate.Density extended 0.001 g/cm3 Liquid temp./pressure: -50. 180 C /Up to 100 bar Approved according to ATEX EEx em[ib] IIC T2.T6Software forparameterizationSITRANS F C mass flowmeters4Measurement of liquids Multiparam- Transmitters MASS 6000 and4/105eter transmitter for remote or com- MASS 6000 Ex dpact mounting measuring mass Digital signal processing measuringflow, density, temperature and frac30 times a second.tion e.g. Brix and Plato 3 current, 2 freq. and 2 relay outputs Adaptive batch function SENSORPROM memory unit making iteasy to start up the flow meter. Easy retrofitting of communicationmodules (AOM) Approved according to ATEX [EEx ia]IIC / EEx de [ia/ib] IIC T6SITRANS F US ultrasonic flowmetersSONO 3000 is a transit time based SONO 3000 transmitters4/152transmitter designed for ultrasonic Selectable uni or bidirectional countingflowmetering on liquids of any pipein the SONO series up to DN 4000 Automatic reading of SENSORPROMdata for easy commissioning Multiple functional output for processcontrol Pulse/frequency and relay output (status, flow direction, limits) Plug and play for all mediaThe main application forSONO 3300 ultrasonic flowmetersis to measure the volume of: Water and treated waste water Oil and liquid gases Hot water/cooling systems4/4Siemens FI 01 · 2005SONO 3300 Industry4/170 DN 50 150 (2” 6”) cast iron DN 200, 250 and 300 (8”, 10”, 12”)welded steel Flow 0.3 3200 m³/h Transmitter can be compact or wallmounted Signal cables from transmitter to transducer are highly protected from aggressive environment by protection ofstainless steel pipesSIMATIC PDM

SITRANS F flowmetersSITRANS FProduct overviewApplicationDescriptionCatalogpageThe main application forSONO 3100 ultrasonic flowmetersis to measure the volume of: Water and treated waste water Oil and liquid gases Liquid cryogenic application District heating systemsSONO 3100 Industry4/163 Replaceable transducers under pressure ATEX approved Measure on all liquids less than350 Cst, conductive or non-conductive No pressure drop 4-track on request Special material on requestSoftware forparameterizationInstallation of one, two or four trans- Flow sensor SONOFLO SONOKIT4/191ducer sets in existing concrete or DN 200 . DN 4000 (8" . 160")steel pipes. Control and display unit Temperature of medium: -20 . 200 C(-4 . 395 F) Installation on empty pipes or pipes under pressure (hot-tap installation)Designed for accurate, high resolution flow measurement in waterbased district heating plants e.g.local networks, boiler stations orsubstations and in chilled waterapplications.Flow sensor SONO 3300 CT and4/175transmitter DN 50 . DN 1200 (2" . 28") Painted carbon steel flanges and metering tube and AISI 316 transducers Water temperatures from 3 . 200 C(37.4 . 392 F) Approved for custody transfer according to PTB, class C and OIML R75,class 4Designed for accurate high-resolution flow measurement in waterbased district heating plants andcooling systems.SONOCAL 3000 is designed to beconnected to SITRANS F US105heatmeter.Flow sensor and transmitter4/184SONOCAL 3000 DN 50 1200 (2” 8”) Painted carbon steel flanges and metering tube, AISI transducers Water temperatures 3 200 C(37 392 F) Approved for custody transfer according to PTB Class C, OIML R75 Class 4and a number of other countries4Battery-driven ultrasonic flowmeter Flow sensor SONOFLO SONOCELL4/199used mainly for irrigation to mea DN 80, DN 100, DN 125, DN 150,sure water flow rate and volume.DN 200, DN 225, DN 250, DN 300 andEnabling data retrieval from transDN 400 (3", 4", 5", 6", 8", 10", 12", 14"mitter by means of a hand-held terand 16")minal. Hot dipped galvanized steel (AISI 304on request) Temperature of medium: 2 . 55 C(4 . 131 F)SITRANS F VA variable area metersMeasurement of volume of transparent liquid and gas flows inclosed pipelines.Minix Product scales for liquids and gases Rugged design with various materials Can be used for high pressures Suitable for panel mounting and ingroups4/212Siemens FI 01 · 20054/5

SITRANS F flowmetersSITRANS FProduct nt of flow of transparent Trogflux4/216liquids and gases, e.g. for water Trogamid (optionally polysulfone) flowtreatment, measurement of coolingtube with various float materialswater, measurement of gas inclu Connections: G ¼" to G 2", alternativelysions.with adhesive bushing Temperature of medium: max. 140 C(284 F) Optionally available with contactsMeasurement of flow of transparent Tubux4/220liquids and gases. Glass flow tube with various float materials Connections: G ¼" to G 2", alternativelywith adhesive bushing Temperature of medium: max. 150 C(302 F) Optionally available with contacts4Measurement of flow of liquids and 2504/228gases, also highly suitable for cor- All-metal variable area meter with varirosive media, high temperaturesous float materialsand high pressures. Connections: DN 15 . DN 100(½" . 4") Temperature of medium:-20 C . 300 C(-4 to 572 F) Optionally available with analog outputor contactsMeasurement of flow of transparent Unox4/235liquids and gases. Glass flow tube with various float materials, additional cover with safety glass Connections: DN 15 . DN 80 (½" . 3")SITRANS F O orifice plate flowmeters4/243VdS-approved measurement of flow Turbo-Luxin sprinkler systems. Measurement of flow according to differential pressure principle with bypassorifice Nominal diameters: DN 80 . DN 250(3" . 10") VdS approval No.: G 4770010Measurement of flow of liquids and N44/247gases, e.g. for filter monitoring. Measurement of flow according to differential pressure principle with bypassorifice Nominal diameters: DN 40 . DN 400(1½" . 16") Temperature of medium: max. 60 C(140 F) Optionally available with contactsSITRANS F O delta pMeasurement of flow with orificeplates and metering pipes formounting between flanges, e.g.together with SITRANS P transmitters, DS III and DS III PA series. Nominal diameters DN 10 . DN 1000 4/251(0.4" . 40") Temperature of medium: -200 . 500 C (-328 . 932 F) for vapors, gasesand liquids.SITRANS P transmitters DS III series DS III PA series4/6Siemens FI 01 · 2005Software forparameterization

SITRANS F flowmetersSITRANS FProduct overviewApplicationDescriptionCatalogpageSoftware forparameterizationSITRANS F I flap flowmetersMeasurement of flow of liquids and Gardex4/274 Baffle plate flowmetergases, e.g. for use with domesticinstallations and heating systems. Nominal diameters: DN 25 . DN 300(1" . 12") Temperature of medium: max. 300 C(572 F) Optionally available with analog outputor contactsMeasurement of flow of transparent Intra4/279liquids, e.g. for use with domestic Flowmeter according to the flap princiinstallations and heating systems.ple Nominal diameters: DN 25 . DN 150(1" . 6") Temperature of medium: max. 150 C(302 F)4Measurement of flow of liquids, e.g. Prima4/279for use with domestic installations Flowmeter according to the flap princiand heating systems.ple Nominal diameters DN 25 . DN 150(1" . 6") Temperature of medium: max. 250 C(482 F) Optionally available with contactsSITRANS F R liquid metersRotary-piston metersIndustrial design for measurementof flowing liquids DN 15 . DN 80 (½" . 3") for industrial 4/285requirements DN 25 (1") as acid-resistant version With the required registers and quantitypreset registers Temperature of medium: from-30 . 300 C (-22 . 572 F)Automatic batchmeter DN 25 . DN 50 (1" . 2")Any quantity of liquid can be prese- Temperature of medium: fromlected and filled automatically.-30 . 300 C (-22 . 572 F)4/285Drum meters SITRANS A alcohol meter for taxingpurposes, standard samplerFor use in open or closed pipelines,e.g. for measurement of condensation.4/357Meters for lubricating oilsMechanical pistol-grip meter Pistol-grip and stationary meters Also with official approval for custodytransfer Temperature of medium: from10 . 60 C (50 . 140 F)Meters for lubricating oilsWith electric pulser As stationary meter with digital display; 4/355also with official approval for custodytransfer Temperature of medium: max. 40 C(104 F)4/351Capacitive flow monitoring2-wire switch for interface and prod- SITRANS PD 5005/139uct presence detection, even in Equipped with the HART Smart protoextreme and critical process condicol for remote setup and calibrationtions; suitable for use on any ferrous High sensitivity, accurate measurementor non-ferrous piping systemof small changesSiemens FI 01 · 20054/7

SITRANS F flowmeters SITRANS F Product overview 4/2 Siemens FI 01 · 2005 4 Overview Application Description Catalog page Software for parameterization SITRANS F M electromagnetic flowmeters Choose MAG 5000/6000 for more demanding applications where you need the benefits of highly func-tional, accura

Related Documents:

SITRANS F flowmeters SITRANS F M MAGFLO MAG 5100 W Siemens FI 01 · 2007 4/57 4 Overview The SITRANS F M MAGFLO MAG 5100 W is an electromagnetic flow sensor designed to meet ground water, drinking water, waste water, sewage or sludge applications. Benefits DN 25 to DN 1200 (1” to

SITRANS F flowmeters SITRANS F M MAGFLO MAG 1100 Food Siemens FI 01 · 2008 4/51 4 MAG 5000/6000 transmitters and sensors are packed in sepa-rate boxes, the final assembly takes place during installation at

ciated transmitter MAG 5000, 6000 and 6000 I. . FM Class 1 Div 2 CSA Class 1, Div 2 1) Larger sizes on request 2) Conditions are also dependent on liner characteristiques 3) Sealing O-ring in Viton. SITRANS F flowmeters SITRANS F M MAGFLO MAG 3100/3100 Ex Siemens FI 01 · 2007 4/67 4

Ultrasonic flowmeters SITRANS FUH1010 IP65 NEMA 4X Instruction Manual - September 2008 . Controlotron is now part of: Siemens Energy & Automation, Inc. Process Instrumentation Business Unit (PI BU) . Flowmeter configurations included with this change include all SITRANS F Gas Flowmeters (7ME361*). 2. Flow Units

SITRANS F M Transmitter MAG 5000/6000 4/30 Siemens FI 01 · 2009 4 Safety barrier (e/ia) Electrode cleaning unit Cleaning unit The Siemens cleaning unit can be used with MAG 5000 or 6000 in 19” insert version. The cleaning unit can be used in applications where the liner and

SITRANS F Flowmeters SITRANS F M MAG 5000/6000 Operating Instructions Electromagnetic flow transmitter designed for use with flow sensor types MAG 1100/1100 F/3100/3100 P/5100 W C

SITRANS F M MAG 1100 DN 2- DN 100 SITRANS F M MAG 1100 DN 2- DN 3 1.3 Items supplied SITRANS F M MAG 1100/1100 F Calibration report DVD with documentation and cerificates . Siemens’ products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and .

Coronavirus disease 2019 (COVID-19) emerged in December 2019 in Wuhan, the capital of Hubei province, China. This highly contagious disease is currently spreading across the world and throughout EU/EEA Member States, with a daily increase in the number of affected countries, confirmed cases and infection -related deaths. Updated data are publisheddaily on the ECDC and World Health Organization .