SITRANS F flowmetersSITRANS F MMAGFLO MAG 5100 W Overview ApplicationThe main applications of the SITRANS F M MAGFLO electromagnetic flow sensors can be found in the following fields: Water abstraction Water treatment Water distribution network (leak detection management) Custody transfer water meters Irrigation Waste water treatment Filtration plant (e.g. reverse osmosis and ultra filtration) Industrial water applications4 Mode of operationThe flow measuring principle is based on Faradays law of electromagnetic induction were the sensor converts the flow into anelectrical voltage proportional to the velocity of the flow. Function Highly resistant to a wide range of chemicals- OIML R49 and PTB approved- conforms to ISO 4064 and EN 14154- MI 001 Custody Transfer approval for billing from 1th November 2006 Meets EEC directives: PED, 97/23/EC pressure directive forEN1092-1 flanges Simple onsite or factory upgrade to IP68 / NEMA 6P of a standard sensor. IntegrationThe SITRANS F M MAGFLO MAG 5100 W is an electromagneticflow sensor designed to meet ground water, drinking water,waste water, sewage or sludge applications. BenefitsThe complete flowmeter consists of a flow sensor and an associated transmitter SITRANS F M MAGFLO MAG 5000,MAG 6000 or MAG 6000 I.The flexible communication concept USM II simplifies integration and update to a variety of fieldbus systems, e.g. HART,PROFIBUS DP & PA, MODBUS RTU/RS485. DN 25 to DN 1200 (1” to 48”) Connection flanges EN 1092-1 (DIN 2501), ANSI, AWWA andAS. NBR Hard Rubber liner for all water applications Drinking water EPDM liner with approvals Hastelloy integrated grounding and measuring electrodes Increased low flow accuracy for water leak detection, due toconed liner design. Drinking water approvals Suitable for direct burial and constant flooding Build-in length according to ISO 13359 - Please note newbuild-in length from DN 500 to DN 1200 Easy commissioning, SENSORPROM unit automatically uploads calibration values and settings. Designed that patented in-situ verification can be conducted.Using SENSORPROM fingerprint.Siemens FI 01 · 20074/57

SITRANS F flowmetersSITRANS F MMAGFLO MAG 5100 W Technical specificationsDesignFull bore sensorConed bore sensorFull bore sensorNominal sizeDN 25 . 40 (1” . 1½”)DN 50 . 300 (2” . 12”)DN 350 . 1200 (14” . 48”)Measuring principleElectromagnetic inductionExcitation frequency12.5 Hz 50 . 65 mm (2” . 2½“): 12.5 Hz 80 . 150 mm (3” . 6“): 6.25 Hz 200 . 300 mm (8” . 12“):3.125 HzDN 350 . 450 (14" . 18"): 3.125 HzDN 500 . 1200 (20" . 48"):1.5625 Hz- StandardPN 40 (580 psi) 50 . 150 mm: PN 16(2“ . 6“: 230 psi) 200 . 300 mm: PN 10(8“ . 12“: 145 psi)PN 10 (145 psi)- Option-- 200 . 300 mm: PN 16(8“ . 12“: 230 psi)PN 16 (230 psi) ANSI B16.5Class 150 lbClass 150 lb 20 bar (290 psi)-- AWWA C-207----28” . 48”: Class D AS4087PN 16 (230 psi) DN 50 . 1200 (2" . 48"), 14 bar (232 psi)Process connectionFlanges EN 1092-14Rated Operation conditionsAmbient temperature Sensor-40 . 70 C (-40 . 158 F) With compact transmitterMAG 5000/6000-20 . 50 C (-4 . 122 F) With compact transmitterMAG 6000 I-20 . 60 C (-4 . 140 F)Operating pressure0.01 . 40 bar (0.15 . 580 psi)0.03 . 20 bar (0.44 . 290 psi)0.01 . 16 bar (0.15 . 232 psi)Enclosure rating StandardIP67 to EN 60529 / NEMA 4X/6 (1 mH2O for 30 minutes) OptionIP68 to EN 60529 / NEMA 6P (10 mH2O continuously)Pressure drop at 3 m/s (10 ft/s)As straight pipeMax. 25 mbar (0.36 psi)Medium conditionsTemperature of medium NBR-5 . 70 C (23 . 158 F) EDPM-5 . 70 C (23 . 158 F)EMC89/336 EECDesignWeightSee dimensional drawingsMaterial Housing and flangesCarbon steel ASTM A105 Measuring pipeAISI 304 (1.4301) LinerNBR Hard Rubber/EPDM ElectrodesHastelloy C276 Grounding electrodes standardHastelloy C276Certificates and approvalsDrinking water approvals EPDMNSF61 (Cold water, US)WRAS (WRc, BS6920 cold water, GB)ACS listed (F)KTW D1 & D2, DVGW W270 (D)ApprovalsPED – 97/23 EC1) FM Class 1 div 21)For sizes larger than 600 mm (24”) PED conformity is available as a costadded option. The basic unit will carry the LVD (Low Voltage Directive) andEMC approval.4/58Siemens FI 01 · 2007As straight pipe

SITRANS F flowmetersSITRANS F MMAGFLO MAG 5100 WThe effect of temperature on working pressure MAG 5100 WPressure in bar (psi)Sizes 25 mm, 40 mm and 300 mm (1”, 1½” and 12”)TemperatureFlange spec.Flange rating 20 C (68 F)50 C (122 F) / 70 C (158 F)EN 1092-1PN 1010.0 (145)9.7 (141)PN 1616.0 (232)15.5 (225)PN 4040.0 (580)38.7 (561)ANSI B16.5150 lbs19.7 (286)19.3 (280)AWWA C-207Class D10.3 (150)10.3 (150)AS40871)PN 1616 bar (235)16 bar (235)PN 1010.0 (145)10.0 (145)PN 1616.0 (232)16.0 (232)150 lbs19.7 (286)19.7 (286)4Size 50 mm to 300 mm (2” to 12”)EN 1092-1ANSI B16.51)Sizes bigger than DN 300Siemens FI 01 · 20074/59

SITRANS F flowmetersSITRANS F MMAGFLO MAG 5100 WSelection and Ordering dataOrder No.Selection and Ordering dataSITRANS F M Flowsensor MAGFLO MAG 5100 WHastelloy electrodes, carbon steel flanges7 ME 6 5 2 0 -Additional information777 1 7 - 2 777Please add “-Z“ to Order No. and specify Ordercode(s) and plain text.Diameter4Order codeCustomer specific converter setupY20Tag name plate, stainless steel fixed with SS wire(add plain text)Y17} 3F} 3M} 3TTag name plate, plastic (self adhesive)Y18Factory certificate according to EN 10204-2.1C15Factory certificate according to EN 10204-2.2C14DN 125 (5“)DN 150 (6“)DN 200 (8“)} 4B} 4H} 4PSensor cables wired (specify cable order no.)Y40Junction box potted to IP68 with wired cable (specifycable order no.)Y41DN 250 (10“)DN 300 (12“)DN 350 (14“)DN 400 (16“)DN 450 (18“)}}}}}Other postproduction requirements (add desired text)Y99New short build-in lengthsDN 500 (20“)} 6FDN 600 (24“)DN 700 (28“)DN 750 (30“)} 6P} 6Y} 7DDN 800 (32“)DN 900 (36“)DN 1000 (40“)} 7H} 7M} 7R42“44“DN 1200 (48“)} 7U} 7V} 8BDN 25 (1“)DN 40 (1½“)DN 50 (2“)} 2D} 2R} 2YDN 65 (2½“)DN 80 (3“)DN 100 (4“)4V5D5K5R5Y,to ANSI B16.5class 150 (1“ . 24“)}}}}JLto AS 4087PN 16NLiner BUS PA Profile 3PROFIBUS DP Profile 3MODBUS RTU/RS 485Cable glands/terminal boxMetric: polyamid terminal box or 6000 I compact½" NPT: polyamid terminal box or 6000 I compact} Available ex stock.4/60Siemens FI 01 · 2007}SymbolPlease also see www.siemens.com/SITRANSForderingfor practical examples of orderingto AWWA C-207Class D (28“ . 1200“)No transmitter (can be ordered separately)MAG 6000 I, 18 . 90 V DC; 115 . 230 V AC,50 . 60 HzFDK-085U0220Product selector link: www.pia-selector.com/its main en.aspBCDFEPDMHard RubberOrder No.Potting kit for terminal box ofMAGFLO sensors forIP68/NEMA 6PPlease use online Product selector to get latest updates.Flange norm and pressure ratingto EN 1092-1PN 10 (DN 200 . 1200/8“ . 48“)PN 16 (DN 50 . 1200/2“ . 48“)PN 16, non PED (DN 700 . 1200/28“ . 48“)PN 40 (DN 25 . 40/1“ . 1½“)DescriptionABFGE12

SITRANS F flowmetersSITRANS F MMAGFLO MAG 5100 W153 (6.0)153 (6.0) Dimensional drawingsM20 (½" NPT)DN 50.300AADN 25.40DN 350.1200M20 (½" NPT)LNominal sizeA4LLPN 10PN 16PN 40Class 150 / AWWA h][mm] 158851948--861189681317891200PN 16PN 40- not availableWith transmitter MAG 5000 and MAG 6000 compact, weight is increased by approximately 0.8 kg (1.8 lbs),with MAG 6000 I, weight is increased by 5.5 kg (12.1 lb).Siemens FI 01 · 20074/634

SITRANS F flowmeters SITRANS F M MAGFLO MAG 5100 W Siemens FI 01 · 2007 4/57 4 Overview The SITRANS F M MAGFLO MAG 5100 W is an electromagnetic flow sensor designed to meet ground water, drinking water, waste water, sewage or sludge applications. Benefits DN 25 to DN 1200 (1” to

Related Documents:

SITRANS F flowmeters SITRANS F Product overview 4/2 Siemens FI 01 · 2005 4 Overview Application Description Catalog page Software for parameterization SITRANS F M electromagnetic flowmeters Choose MAG 5000/6000 for more demanding applications where you need the benefits of highly func-tional, accura

SITRANS F flowmeters SITRANS F M MAGFLO MAG 1100 Food Siemens FI 01 · 2008 4/51 4 MAG 5000/6000 transmitters and sensors are packed in sepa-rate boxes, the final assembly takes place during installation at

ciated transmitter MAG 5000, 6000 and 6000 I. . FM Class 1 Div 2 CSA Class 1, Div 2 1) Larger sizes on request 2) Conditions are also dependent on liner characteristiques 3) Sealing O-ring in Viton. SITRANS F flowmeters SITRANS F M MAGFLO MAG 3100/3100 Ex Siemens FI 01 · 2007 4/67 4

Ultrasonic flowmeters SITRANS FUH1010 IP65 NEMA 4X Instruction Manual - September 2008 . Controlotron is now part of: Siemens Energy & Automation, Inc. Process Instrumentation Business Unit (PI BU) . Flowmeter configurations included with this change include all SITRANS F Gas Flowmeters (7ME361*). 2. Flow Units

SITRANS F M Transmitter MAG 5000/6000 4/30 Siemens FI 01 · 2009 4 Safety barrier (e/ia) Electrode cleaning unit Cleaning unit The Siemens cleaning unit can be used with MAG 5000 or 6000 in 19” insert version. The cleaning unit can be used in applications where the liner and

SITRANS F Flowmeters SITRANS F M MAG 5000/6000 Operating Instructions Electromagnetic flow transmitter designed for use with flow sensor types MAG 1100/1100 F/3100/3100 P/5100 W C

SITRANS F M MAG 1100 DN 2- DN 100 SITRANS F M MAG 1100 DN 2- DN 3 1.3 Items supplied SITRANS F M MAG 1100/1100 F Calibration report DVD with documentation and cerificates . Siemens’ products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and .

accounting profession plays in economic and social development of societies. The Imperatives of Accounting Profession. In a long narrative (Burchell, et al., 1980) stated that the roles of accounting which grace the introductions to accounting texts, professional pronouncements and the statements of those concerned with the regulation and development of the profession is a clear manifestation .