Fuji Duo Series SC-E s 5 to 100 hp at 480 VAC cULus and CSA approval, CE mark, meetsJIS and IEC standards. Models SC-E02-xxx to SC-E4-xxx have3-pole main circuits and come in threesizes with widths of 43 mm, 54 mm, and67 mm. Models SC-E1-xxx to SC-E7-xxx employ abox terminal structure; allowing wires to beconnected directly to the main circuit. Has a finger-protection terminal structurethat prevents the exposure of live parts. Models SC-E5-xxx to SC-E7-xxx use aSUPERMAGNETTM (AC-input/DC-outputoperation) for high operating reliabilityand requires no surge suppressor.ProgrammableControllersField I/OSoftwareSC-E2S Terminals with finger-touch protection(DIN 57106/VDE 0106 Teil100)Standards & Approvals UL listed , file E42419, Standard UL 508 cUL listed, file E42419,Standard CSA C 22.2 No.14 VDE 0660 JIS C 8201-4-1 IEC 60947-4-1 / EN 60947-4-1 CE compliantUtility Box lug terminal construction Long electrical life Easy to wireEnvironmentalSmall Size Low power consumption Recycled thermoplastic resin used forplastic parts. The names of materials are indicated onall major parts to facilitate recycling SC-E02-xxx to E05-xxx: 43mm wide SC-E1-xxx to E2S-xxx: 54mm wide SC-E3-xxx, E4-xxx: 67mm wide SC-E5-xxx: 88mm wideC-more &other HMISC-E7SafetyOptional accessories Auxiliary contact blocks Coil surge suppression units Replacement coils for contactor sizesSC-E5 and CSC-E05G-24VDC --- 24VAC --- 110VAC --- 220VAC --- 440-480VAC --- 500-550VAC --- 24VDC --- 24VAC --- 110VAC --- 220VAC --- 440-480VAC --- 500-550VAC --- 24VDC --- 24VAC --- 110VAC --- 220VAC --- 440-480VAC --- 500-550VAC --- 24VDC --- 24VAC --- 110VAC --- 220VAC --- 440-480VAC --- 500-550VAC --- TABLE CONTINUED NEXT PAGEMotors rsLimitSwitchesFrame Width(mm)Rated InsulationVoltage (V)SCCR Ratings(KA)400– 550– 100– 220–200V 220–240V 480V 600V 120V 240VRated AC-1Thermal Current(A) [note 2]1-PhaseMotor3-Phase MotorRated AC-3Current (A) [note 1]PriceNominal CoilVoltageModelSoftStartersPhotoSensorsSC-E Series Contactors Specifications - UL and CSARated Capacity locks 24VDCPart #IndexNotes: 1. AC3 type loads consist of squirrel cage three-phase motors; occasional, limited jogging duty.2. AC1 non-inductive or slightly inductive loads. Typically resistive loads (i.e. furnaces, ovens, etc.)Volume 13w w w . a u t o m a t i o n d i r e c t . c o m / m o t o r- c o n t r o l sMotor Controlse17-5

Fuji Duo Series SC-E -E7-400VSC-E7-500V --- 24VAC --- 110VAC --- 220VAC --- 440-480VAC102525233250 --- 500-550VAC --- 24VDC --- 24VAC --- 110VAC --- 220VAC --- 440-480VAC10153030354060 --- 500-550VAC --- 24VDC --- 24VAC --- 110VAC --- 220VAC --- 440-480VAC152030303105065 --- 500-550VAC --- 24VDC --- 24VAC --- 110VAC --- 220VAC --- 440-480VAC2025505051565100 --- 500-550VAC --- 24VDC --- 24VAC --- 110VAC --- 220VAC --- 440-480VAC --- 500-550VAC --- 24VDC --- 24VAC/VDC --- 110VAC/VDC --- 220VAC/VDC --- 380-450VAC --- 460-575VAC --- 24VAC/VDC --- 110VAC/VDC --- 220VAC/VDC --- 380-450VAC --- 460-575VAC --- 24VAC/VDC --- 110VAC/VDC --- 220VAC/VDC --- 380-450VAC1-PhaseMotor3-Phase Motor400– 550– 100– 220–200V 220–240V 480V 600V 120V 240VFrame Width(mm)PriceNominal CoilVoltageModelRated InsulationVoltage (V)Rated AC-1Thermal Current(A) [note 2]7.5Rated Capacity (HP)SCCR Ratings(KA)Rated AC-3Current (A) [note 1]SC-E Series Contactors Specifications - UL and 751001020125150505010012515251502008810100115 --- 460-575VACNotes: 1. AC3 type loads consist of squirrel cage three-phase motors; occasional, limited jogging duty.2. AC1 non-inductive or slightly inductive loads. Typically resistive loads (i.e. furnaces, ovens, etc.)Volume 13e17-6Motor Controls1 - 80 0 - 633 - 0405

Fuji Duo Series SC-E mableControllersSC-E Series Contactors Specifications - IECContactor TypeRated Capacity (kW)Rated Operating Current (A)3-Phase Motor AC-3 / AC-43-Phase Motor AC-3 / ve )InternalAuxilliaryContactArrangementField I/OSoftware2.2 / 2.24/44 / NA4 / NA9/99/97 / NA5 / NA202020-C-more &other HMI3/35.5 / 5.55.5 / NA5.5 / NA12 / 1212 / 129 / NA7 / NA202020-Drives4/47.5 / 7.57.5 / NA7.5 / NA18 / 1818 / 1813 / NA9 / NA252525-5.5 / 411 / 7.511 / NA7.5 / NA25 / 1825 / 1817 / NA9 / NA323232-7.5 / 7.515 / 1515 / NA11 / NA32 / 3232 / 3224 / NA15 / NA505050-11 / 1118.5 / 18.518.5 / NA15 / NA40 / 4040 / 4029 / NA19 / NA606060-15 / 1122 / 18.525 / NA22 / NA50 / 4050 / 4038 / NA26 / NA656565-18.5 / 18.530 / 3037 / NA30 / NA68 / 6865 / 6560 / NA38 / NA100100100-22 / 18.540 / 3037 / NA37 / NA80 / 6880 / 6560 / NA44 / NA105105105-30 / 3055 / 555 5/ NA55 / NA105 / 105105 / 10585 / NA64 / NA1501501502NO 2NC37 / 3760 / 606 0 / NA60 / NA125 / 125125 / 12590 / NA72 / NA1501501502NO 2NC45 / 4575 / 7575 / NA90 / NA150 / 150150 / 150120 / NA103 / NA2002002002NO 2NCSoftStartersMotors rsPhotoSensorsLimitSwitchesInternal Auxiliary Contact RatingsEncodersCurrentSensorsInternal Auxiliary Contact Ratings - UL and CSAFrame Size( note 1 )NEMA ICS 5-2000 Ratings ( note 2 )AC RatingsDesignationMaking VARatedInsulationVoltage (V)DC RatingsDesignationBreaking VA690A6007200720E5 to E7-xxxNotes:1. E02(G) to E4(G) do not have internal auxiliary contact.2. NEMA ICS 5-2000. For more information, refer to Control Circuit Contact Electrical Ratings, see page 17-77.PressureSensorsMaking/Breaking rnal Auxiliary Contact Ratings - IEC, JISBased on IEC 60974-4-1, EN 60947-4-1, JIS C 8201-4-1Frame Size( note 1 )E5 to E7-xxxRatedInsulationVoltage (V)690RatedThermalCurrent (A)10Comm.Making and BreakingCapacity (A)AC ge andAC-15DC-13AC Voltage (Ind. load) DC Voltage (Ind. load) CurrentRated Operational Current 0V0.55600V12600V1.2220V0.275VDC, 3mATerminalBlocks &WiringPowerCircuitProtectionEnclosuresToolsNote 1: E02(G) to E4(G) do not have internal auxiliary contact.PneumaticsAppendixProductIndexPart #IndexVolume 13w w w . a u t o m a t i o n d i r e c t . c o m / m o t o r- c o n t r o l sMotor Controlse17-7

Fuji Duo Series SC-E ContactorsCoil CharacteristicsAC Coil CharacteristicsPower Consumption (VA) Power Loss (W)Frame SizeInrushSealedOperating Time (ms)Pick-Up Voltage (V) Drop-Out Voltage (V)50HzCoil ON to Coil OFF toContact ON Contact OFF60Hz50/60Hz50/60HzE02 to E05-xxx90/959/92.72.80.85 - 1.1 x U.S.rated coil voltage0.2 - 0.75 x U.S.rated coil voltage9-205-16E1 to E2S-xxx120/13512.7/12.43.63.80.85 - 1.1 x U.S.rated coil voltage0.2 - 0.75 x U.S.rated coil voltage10-176-13E3, E4-xxx180/19013.3/13.44.550.85 - 1.1 x U.S.rated coil voltage0.2 - 0.75 x U.S.rated coil voltage10-188-1880/954/4.63.23.60.85 - 1.1 x U.S.rated coil voltage0.2 - 0.75 x U.S.rated coil voltage39-4527-33190/2304.9/5.83.43.70.8 - 1.1 x U.S.rated coil voltage0.1 - 0.65 x U.S.rated coil voltage31-3730-36E5-xxxE6, E7-xxxDC Coil CharacteristicsPower Consumption (W)Operating Time (ms)Frame SizePick-Up Voltage (V)InrushDrop-Out Voltage (V)SealedCoil ON toContact ONCoil OFF toContact OFFE02G to E05G-xxx770.85 - 1.1 x U.S.rated coil voltage0.1 - 0.75 x U.S.rated coil voltage45-4910-26E1G to E2SG-xxx990.85 - 1.1 x U.S.rated coil voltage0.1 - 0.75 x U.S.rated coil voltage40-508-17E3G, E4G-xxx12120.85 - 1.1 x U.S.rated coil voltage0.1 - 0.75 x U.S.rated coil voltage60-7014-21E5-xxx202.80.85 - 1.1 x U.S.rated coil voltage0.1 - 0.75 x U.S.rated coil voltage35-4126-32E6, E7-xxx2253.20.8 - 1.1 x U.S.rated coil voltage0.1 - 0.65 x U.S.rated coil voltage28-3427-33Operating CoilAC/DC Coil (SUPERMAGNET),SC-E5-xxx to SC-E7-xxxVoltage Coil Operating Voltage /CodeFrequencyAC Coil, SC-E02-xxx to SC-E4-xxxVoltage Coil Operating Voltage /CodeFrequency24VAC24VAC 50Hz / 24-26VAC 60Hz110VAC100-110VAC 50Hz / 110-120VAC 60Hz220VAC200-220VAC 50Hz / 220-240VAC 60Hz440VAC415-440VAC 50Hz / 440-480VAC 60Hz500VACOperating CoilOperating Coil480-500VAC 50Hz / 500-550VAC 60Hz24V24-25VAC 50/60Hz; 24VDC100V100-127VAC 50/60Hz; 100-120VDC200V200-250VAC 50/60Hz; 200-240VDC400V380-450VAC 50/60Hz500V460-575VAC 50/60HzDC Coil, SC-E02G-xxx to SC-E4G-xxxVoltage Coil Operating VoltageCode24VDC24VDCPerformance DataFrame sizeMaking current (A)220V440VBreaking current (A)220V440VOperating cyclesper hourDurability 00120012002 million1.5 million1.5 million1.5 million1.5 million1.5 million10 million10 million10 million10 million10 million10 1.5 million1.5 million10 million5 0065010501250150012001200120012001 million1 million1 million1 millionSC-E4SC-E5SC-E6SC-E75 million5 million5 million5 millionVolume 13e17-8Motor Controls1 - 80 0 - 633 - 0405

*Free on ordersover 300Get it fast AND free!** for items shipped fromCumming, GAFree standard 2-day (transit)* shipping is now available for orders over 300,within the U.S. and Puerto Rico. We use our choice of carrier and a combination of ground and air services that allow us to reach any U.S. destinationwithin 2 days transit time (or less). (Canadian orders use the same method, butmay take up to 3 days in transit based on destination.) Orders placed by6 p.m. EST will ship the same day (with approved company credit or creditcard; LTL items require 5 p.m. order cutoff).Note that the 2-day transit time does not apply for LTL shipping of heavy itemsor drop-shipped items. (We cannot ship heavy items to Hawaii or Puerto Rico.To determine if an item is excluded, check the “Availability” column of theprinted price list.)For orders under 300, you may request that your order ship via the 2-day(transit) method; shipping charges will be added to invoice.For complete details on shipping methods and charges, see Terms andConditions pages TC-4 to 6.* We do not guarantee delivery times of the carriers. AutomationDirect is notresponsible for carrier delays due to weather, mechanical failures or other issues.1-800-633-0405www.automationdirect.com

Fuji Duo Series SC-E ContactorsStandard operatingconditionsThe magnetic contactors are manufactured for use in the standard operatingconditions given in the table.Standard Operating ConditionsOperating: -5 to 55 CNo sudden temperature changes resulting in condensation or icing(The average temperature over a 24-hour period must not exceed 35 C)Storage: -40 to 65 CAmbientTemperatureHumidityAltitude45 to 85%RH2000m or lowerAtmosphereNo excessive dust, smoke, corrosive gases, flammable gases, steam, or saltVibrationShock10 to 55Hz 15m/s2Mounting35mm IEC DIN railmounting (SC-E02 to SC-E4), screw mounting50m/s2Mounting Angle 30Be sure to perform wiring correctly withreference to the wiring diagrams. Mainterminals for models SC-E02 to SC-E7 arewired using solid wires or stranded wires.Stranded wires or flexible stranded wirescan be connected by twisting themtogether and crimping a sleeve (ferrule)onto them before connecting.Tightening torqueIf wires are not tightened sufficiently, theymay become hot or loosen, resulting in afire, short-circuit, electric shock, or otherpotentially dangerous situation. Tightenwires to the torques specified in thesetables. 30 30 IEC 947-4-1, EN 60947-4-1, VDE 0660JIS C 8201-4-1, JEM 1038UL 508, file E42419; CSA C22.2, file 20479StandardWiring30Wire Sizes, Tightening Torques - Control CircuitSolid or Stranded Wire (mm2)AWGOne0.75 to 2.5 (1 to 1.6 mm diameter)Two0.75 to 2.5 (1 to 1.6 mm diameter)One18 to 14Two18 to 1410 mmInsulation Stripping LengthFork TerminalMax. 7.7mm wideTerminal Screw SizeM3.5Phillips screwdriver, H-type, No. 2 (ISO 8764);ADC part number DN-SP1 or DN-SP2Flat-blade screwdriver, 1 x 5.5 x L-type, B (ISO 2830);ADC part number DN-SS5ToolTightening Torque (N.m)0.8 to 1Wire Sizes, Tightening Torques - Main CircuitContactor TypeSolid Wire (mm2)Stranded Wire (mm2)AWGInsulation Stripping LengthTerminal Screw SizeToolTightening Torque (N.m)SC-E02-xxx SC-E03-xxx SC-E04-xxx SC-E05-xxxOne0.75 to 40.75 to 6Two1 to 41.5 to 6One0.75 to 40.75 to 6Two1 to 41.5 to 6One12 max.10 max.Two12 max.10 max.11 mmM4Phillips screwdriver, H-type, No. 2 (ISO 8764);ADC part number DN-SP1 or DN-SP2Flat-blade screwdriver, 1 x 5.5 x L-type, B (ISO 2830);ADC part number DN-SS51.2 to 1.5Volume 13e17-10Motor Controls1 - 80 0 - 633 - 0405

Fuji Duo Series SC-E ing torque (continued)ProgrammableControllersWire Sizes, Tightening Torques - Main CircuitContactor TypeTop-OnlyConnectionSC-E1, E2, E2S-xxxSC-E3, E4-xxx SC-E5, E6-xxx SC-E7-xxxSolid or stranded wire (mm 2) 10.75 to 351.5 to 704 to 704 to 120Flexible stranded wire with sleeve (mm 2) 10.75 to 251.5 to 502.5 to 502.5 to 95Flexible stranded wire without sleeve (mm 2)0.75 to 251.5 to 504 to 504 to 9518 to 216 to 2/012 to 2/012 to 250MCMSoftwareC-more &other HMIDrivesAWGSolid or stripping length (mm)SoftStarters1519.526.528.5Single stranded wire (mmFlexible stranded wire with sleeve(mm 2) 10.75 to 251.5 to 504 to 704 to 1200.75 to 161.5 to 352.5 to 502.5 to 95Steppers/ServosFlexible stranded wire without sleeve (mm 2)0.75 to 161.5 to 354 to 504 to 95MotorControls18 to 316 to 1/012 to 2/012 to 250MCM12.51626.528.5Top/bottom0.75 to 251.5 to 504 to 704 to 120Top/bottom0.75 to 161.5 to 352.5 to 502.5 to 952) 1Bottom-OnlyConnectionField I/OAWGSheath stripping length (mm)Solid or stranded wire(mm 2) 1Flexible stranded wire with2 1To p / B o t t o m sleeve (mm )ConnectionFlexible stranded wire withoutsleeve (mm 2)AWGMotors ncodersTop/bottom0.75 to 161.5 to 354 to 504 to 95Top/bottom18 to 316 to 1/012 to 2/012 to 250MCMPhillips screwdriver, H-type, No.2(ISO 8764);ADC part number DN-SP1 or DN-SP2ToolTightening Torque (Nm)Self-locking Torque (Nm) 2Note 1: Stranded wire (0 to 25mm2) consists of 7 wires or less.Stranded wire (35 to 120mm2) consists of 19 wires or less.Flexible stranded wire consists of more number wires thanthe above.Flat-blade screwdriver, 1 x 5, 5xLtype, B (ISO 2830);ADC part number SensorsHex. wrench 4 (ISO 2936)Pushbuttons/Lights8102Note 2: The tightening bolt must be loosened in order to insert the wire. However, stoploosening the bolt when the anti-drop attachment on the bottom of the bolt reachesthe top edge of the terminal. If a torque exceeding that given in the table is appliedin this state, the retaining bracket may loosen.ProcessRelays/TimersComm.TerminalBlocks ticsAppendixProductIndexPart #IndexVolume 13w w w . a u t o m a t i o n d i r e c t . c o m / m o t o r- c o n t r o l sMotor Controlse17-11

Fuji Duo Series SC-E ContactorsElectrical durabilitySC-E0510000SC-E04380 - 440VSC-E03200 - 240VSC-E02AC-3 duty / SC-E02 to SC-E05-xxx10000Make/break operations ( W200 - 240V304kW380 - 440V18A105010025A512A33-phase motor capacity (kW)and full-load current (A)2.2kW29A1102003005001000Breaking current (A)200 - 240V100200300500100020003000500010000Breaking current (A)37kW45kW380 - 440VSC-E750105A125A60kW 150A75kW30SC-E6SC-E5SC-E3SC-E4203-phase motor capacity (kW)and full-load current (A)55kW101030kW201065A302040kW 0030040A50032A100015kWMake/break operations ( E2S380 - 440V10000SC-E110000200 - 240VSC-E2AC-3 duty / SC-E1 to SC-E7-xxxSC-E2SC-E2SSC-E1SC-E04SC-E05380 - 440VSC-E03200 - 240VSC-E02AC-1 duty / SC-E02 to SC-E7-xxxMake/break operations ( 5001000Breaking current (A)Volume 13e17-12Motor Controls1 - 80 0 - 633 - 0405

Fuji Duo Series SC-E ContactorsDimensions (mm)Wiring diagramsContactorsContactors1(68) *43Mainterminal M4Coil terminalM3.5Panel drilling34160(48 to)52804920(28) *214.591(Rail height 15)81618.518.5(to 20.5)SC-E02, E03, E04, E05-xxx2SC-E02 to E05-xxxSC-E1 to E4-xxxSC-E02G to E05G-xxxSC-E1G to E4G-xxxSC-E2S, E2SG-xxx*1*153*21310.5Mounting hole2-M4Weight:0.33 kgMass: 0.33kg*161 1/L1 3/L2 5/L38371A135Use the two mounting holes on a diagonal lineorto mount contactor: 35 60: 35 (48 to) 525462 2/T1 4/T2 6/T384A272SC-E1, E2, E2S-xxx(79) *154Panel drillingCoil terminalM3.5518.545(38 to 46)9.5106 (Rail height 15) (28) *2 Main96terminal65.510.52SC-E5, E6, E7-xxx90*1758057*153 61 13 21 1/L1 3/L2 5/L3 43 31 83 712A1 A21*154 62 14 22 2/T1 4/T2 6/T3 44 32 84 722*Mounting hole2-M416.5Weight:kgMass : 0.580.58kg45*1 In case of aux. contact 4NO 4NCUse the two mounting holes on a diagonal lineorto mount contactor: 45 75: 45 (38 to 46) 80SC-E3, E4-xxxPanel drilling(91) *167Coil terminalM3.5(54 to)6013Mainterminal19.5121 (Rail height 15) (28) *211172.510.5 2.5907711221*2*120.5Mass: 1.1kgWeight:1.1 kgMounting hole (55 to)602-M4Use the two mounting holes on a diagonal lineorto mount contactor: (55 to) 60 90: (54 to) 60 90Volume 13e17-16Motor Controls1 - 80 0 - 633 - 0405

Fuji Duo Series SC-E ons (mm)ProgrammableControllersContactorsField Panel drillingCoil terminalM3.51(111) *8813.513277Software70C-more &other HMISoftStarters75129155DrivesMotors &GearboxMounting hole2-M432Weight: 2.0 kgMass: 2.0kgSteppers/Servos1* Side mounting aux. contact block*2 Front mounting aux. contact liaryterminalM3.5(123) *1100ProximitySensorsPanel drillingCoil terminalM3.513.5138(80 rentSensors32Mounting hole2-M5Mass: ght: 2.6 kg(138) *1115Panel drillingCoil ocks &Wiring146175Mounting hole2-M535Weight: 2.9 kgRelays/TimersComm.Mass: 2.9kgCoil terminalM3.5(68) *431Panel sures20(28) *218.5(to 20.5)PowerSC-E02G, E03G, E04G, E05G-xxx118 (Rail height 15)108888.5Pushbuttons/Lights(80 to)90110Mainterminal14.514076.838.8(48 ting hole2-M4ProductIndex35Weight: 0.59 kgMass: 0.59kgPart #IndexUse the two mounting holes on a diagonal lineorto mount co

Fuji Duo Series SC-E Contactors Internal Auxiliary Contact Ratings. e17-8 Motor Controls 1-800-633-0405 Volume 13 Fuji Duo Series SC-E Contactors DC Coil Characteristics Frame Size Power Consumption (W) Pick-Up Voltage (V) Drop-Out Voltage (V) Operating Time (ms) Inrush Sealed Coil ON toFile Size: 626KB

Related Documents:

Fuji Duo Series SC-E Contactors SC-E Series Contactors Specifications - UL and CSA Model Price Nominal Coil Voltage Rated Capacity (HP) Rated AC-3 Cur-rent (A) [note 1] Rated AC-1 Ther-mal Current (A) [note 2] SCCR Ratings (KA) Rated Insulation Voltage (V) 3-Phase Motor Frame Width (mm) 1-Phase

contactor Contactor number price Accessories for A/AF/AL & AE contactors Discount schedule ABA [OF] 1 Use type VE 5-2 for mechanical and electrical interlocking between A30/A40 and A50 - A75 contactors. Interlocks for two horizontally mounted contactors – AF1350 - AF2050 contactors

Place the mixed Fuji II LC into the cavity. Light cure, trim and finish. Easy Fuji II LC Restoration Technique Simple Sandwich Technique Use Fuji II LC as a base or liner to prevent marginal leakage, provide superior fluoride release and eliminate sensitivity. Prepare cavity, apply GC Cavity Conditioner for 10 seconds and rinse. Place mixed .

2. AC1 non-inductive or slightly inductive loads. Typically resistive loads (i.e. furnaces, ovens, etc.) Fuji Duo Series SC-E Contactors eMS-32 1-800-633-0405 Prices as of April 27, 2016. Check Web site for

Fuji Duo Series SC-E Contactors DC Coil Characteristics Frame Size Power Consumption (W) Pick-Up Voltage (V) Drop-Out Voltage (V) Operating Time (ms) Inrush Sealed Coil ON to Contact ON Coil OFF to Contact OFF E02G to E05G-xxx 7 0.85 - 1.1 x U.S. rated coil voltage 0.1 - 0.75 x U.S. rated coil voltag

Fuji Duo Series SC-E Contactors SC-E Series Contactors Specifications - UL and CSA Model Price Nominal Coil Voltage Rated Capacity (HP) Rated AC-3 Cur-rent (A) [note 1] Rated AC-1 Ther-mal Current (A) [note 2] SCCR Ratings (KA) Rated Insulation Voltage (V) Frame Width (mm) 3-Phase Motor 1-Phase

Lighting Contactors 50767 Power Pole Kit for C30CN Lighting Contactors 50768 Control Module Kit for C30CN Lighting Contactors Contact position indication— when button protrudes, contact is closed Power poles are available as single or double poles, creating 74 different circuit combinations Convenient side access for field power wiring

One more blue cube is put into the box. What fraction of the cubes in the box are blue now? 1 mark . Tadworth Primary School 23 40. 150 people take part in a walk. This chart shows the number of people still walking at different times. 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 Number of walkers 9 am 10 am 11 am 12 pm 1 pm 2 pm 3 pm Time Use the chart to estimate the time when two .