Low Voltage Lighting - Ideadigitalcontent

1y ago
5 Views
2 Downloads
754.98 KB
5 Pages
Last View : 11d ago
Last Download : 3m ago
Upload by : Tia Newell
Transcription

SECTION6LOW VOLTAGE LIGHTING TRANSFORMERS & POWER SUPPLIESLow Voltage LightingA greater selection for your indoor & outdoor low voltage lighting projectsWhy Low Voltage?Acme’s Low Voltage Lightingproducts provide a safe, long lasting, highly reliable power source;a perfect selection for landscapeapplications as well as interior use.Low voltage lighting is a creativemedium with unlimited applicationpossibilities. Low voltage lightingbenefits include:Precision beam controlMore light intensity per wattLess radiated heatGreater efficiencyLonger lifeSafer to useEasy installationA high return on end-userinvestmentAcme AdvantagesMore valueMore protectionAcme low voltage transformers are available in a widerange of options and models that are all UL listed for useindoors or outdoors. See inside back cover for warrantydetails.A full fault current carrying Faraday Shield (except Buck–Boost) prevents 120 volts from reaching the 12 volt side, asrequired by UL-1571 and UL-1838.More PowerThe convenient “Selection Guide” on the facing pageprovides you with the data you need to select the productthat best meets your requirement. Complete productselection data, dimensions and wiring diagrams arecontained on the following pages. If you need help inyour selection, or if you have questions, just call technicalservices at 1-800-334-5214.Transformers in ratings of 100 through 1000 W; Group VIBuck–Boost in .05 through 10 kVA.More convenienceGroups IV, V and VI transformers have copper lead wiresfor hardwiring. Circuit breakers for instant reset (exceptpool and spa and Buck–Boost). No fumbling with fuses.Generous wiring compartment, too!82Features & OptionsACME ELECTRIC MILWAUKEE, WI 800.334.5214 acmetransformer.com

SECTION6LOW VOLTAGE LIGHTING TRANSFORMERS & POWER SUPPLIESSELECTION GUIDETRANSFORMERSGROUP VGROUP VI‘T1’Catalog No.Buck–Boost‘T1’ and ‘T2”Catalog No.Ratings(Watts, VA, kVA)100through1000 VA.05through10 kVAPrimary Input120 Volts or240 Volts120 x 240VoltsSecondaryOutput12V or 24V12 x 24 VHardwired PrimaryYesYesAuto Thermal ResetNoCircuitBreakersNoOutputWiringCopperLead WiresCopperLead WiresUL ListedYesYesCSA y10 Years10 CME ELECTRIC MILWAUKEE, WI 800.334.5214 acmetransformer.com83

6SECTIONLOW VOLTAGE/VOLTAGE LIGHTINGLIGHTINGTRANSFORMERSTRANSFORMERS& POWER SUPPLIESLow Voltage General Purpose TransformersFEATURESUL Listed , CSA Certified.UL class 180 C insulation system 115 C rise.100, 150, 300, 600, 750, 1000 VA.UL Type 2 enclosure.1 Phase, 60 Hz, 120 or 240 volt input.Keyhole slotted wall mounting brackets.12 or 24 volt output.Black finish.Input Auto-Thermal reset switch.Bottom access.Output circuit breaker.Two 0.875 (2.2 cm) single knockoutseach side.Fully encapsulated core and coil.Full fault current carrying Faraday Shield.Flexible copper leadwire terminations.HTwo dual 0.875 (2.2 cm) and 1.125(2.9 cm) knockouts on bottom cover.WDGROUP V120 PRIMARY VOLTS – 12 SECONDARY VOLTS, TWO WINDINGS, 1Ø, 60 HzVAHEIGHTAPPROX. DIMENSIONSINCHES (CM.)WIDTHCATALOG NO.CB RATINGCB STYLEDEPTHAPPROX.SHIP WEIGHTLBS. (KG.)100T179600S9.01 (22.9)4.08 (10.4)3.88 (9.9)7 (3.2)15 AMPPush To Reset Thermal Breaker150T179620S9.01 (22.9)4.08 (10.4)3.88 (9.9)7 (3.2)20 AMPPush To Reset Thermal Breaker300T179621S11.68 (29.7)4.66 (11.8)4.57 (11.6)11 (5.0)40 AMPPush To Reset Thermal Breaker600T179622S11.68 (29.7)4.66 (11.8)4.57 (11.6)15 (6.8)60 AMPMagnetic Toggle On/Off Breaker750T179603S11.68 (29.7)4.66 (11.8)4.57 (11.6)18 (8.2)75 AMPMagnetic Toggle On/Off Breaker1000T179604S11.93 (30.3)5.41 (13.7)5.20 (13.2)26 (11.8)100 AMPMagnetic Toggle On/Off BreakerCB RATINGCB STYLE120 PRIMARY VOLTS – 24 SECONDARY VOLTS, TWO WINDINGS, 1Ø, 60 HzVAHEIGHTAPPROX. DIMENSIONSINCHES (CM.)WIDTHDEPTHAPPROX.SHIP WEIGHTLBS. (KG.)CATALOG NO.100T179605S9.01 (22.9)4.08 (10.4)3.88 (9.9)7 (3.2)7 AMPPush To Reset Thermal Breaker150T179623S9.01 (22.9)4.08 (10.4)3.88 (9.9)7 (3.2)10 AMPPush To Reset Thermal Breaker300T179624S11.68 (29.7)4.66 (11.8)4.57 (11.6)11 (5.0)20 AMPPush To Reset Thermal Breaker600T179625S11.68 (29.7)4.66 (11.8)4.57 (11.6)15 (6.8)40 AMPPush To Reset Thermal Breaker750T179608S11.68 (29.7)4.66 (11.8)4.57 (11.6)18 (8.2)50 AMPPush To Reset Thermal Breaker1000T179609S11.93 (30.3)5.41 (13.7)5.20 (13.2)26 (11.8)50 AMPMagnetic Toggle On/Off BreakerCB RATINGCB STYLE240 PRIMARY VOLTS – 24 SECONDARY VOLTS, TWO WINDINGS, 1Ø, 60 HzVA84HEIGHTAPPROX. DIMENSIONSINCHES (CM.)WIDTHDEPTHAPPROX.SHIP WEIGHTLBS. (KG.)CATALOG NO.100T179615S9.01 (22.9)4.08 (10.4)3.88 (9.9)7 (3.2)7 AMPPush To Reset Thermal Breaker150T179629S9.01 (22.9)4.08 (10.4)3.88 (9.9)7 (3.2)10 AMPPush To Reset Thermal Breaker300T179630S11.68 (29.7)4.66 (11.8)4.57 (11.6)11 (5.0)20 AMPPush To Reset Thermal Breaker600T179631S11.68 (29.7)4.66 (11.8)4.57 (11.6)15 (6.8)40 AMPPush To Reset Thermal Breaker750T179618S11.68 (29.7)4.66 (11.8)4.57 (11.6)18 (8.2)50 AMPPush To Reset Thermal Breaker1000T179619S11.93 (30.3)5.41 (13.7)5.20 (13.2)26 (11.8)50 AMPMagnetic Toggle On/Off BreakerACME ELECTRIC MILWAUKEE, WI 800.334.5214 acmetransformer.com

6SECTIONLOW VOLTAGE/VOLTAGE LIGHTINGLIGHTINGTRANSFORMERSTRANSFORMERS& POWER SUPPLIESBuck-Boost TransformersThe No-Frills LowVoltage LightingBuck-Boost Transformers offer a nofrills approach to low voltage lighting.(See Chart Below) A typical BuckBoost application is 120 volts in and12 volts out for low voltage lighting orcontrol circuitry. In most applications,this low voltage isolation transformeris field connected as an autotransformer. For more information on BuckBoost Transformers, refer to the nextsection in this catalog.HDWGROUP VI120 x 240 VOLT INPUT– 12/24 VOLT OUTPUT – 1Ø, 60 HzCATALOGNUMBERINSULATINGTRANSFORMERRATING0.05 kVASECONDARY MAXIMUMCURRENT OUTPUT12V24V4.162.08APPROX. DIMENSIONSINCHES (CM.)HEIGHTWIDTHDEPTH6.38 (16.2)3.19 (8.1)3.00 (7.6)T181047T1810480.10 kVA8.324.166.62 (16.8)T1810490.15 kVA12.526.257.12 (18.1)3.75 (9.5)3.62 (9.2)7 (3.2)T1810500.25 kVA20.8010.408.68 (22.0)4.08 (10.4)3.88 (9.9)10 (4.5)T1810510.50 kVA41.6020.809.06 (23.0)4.37 (11.1)4.20 (10.7)15 (6.8)T1810520.75 kVA62.5031.259.68 (24.6)4.75 (12.1)4.51 (11.5)19 (8.6)T1116831.00 kVA83.2041.6010.50 (26.7)5.50 (14.0)5.13 (13.0)24 (10.9)T1116841.50 kVA125.0062.5011.62 (29.5)5.50 (14.0)5.13 (13.0)30 (13.6)T1116852.00 kVA166.0083.2013.00 (33.0)5.50 (14.0)5.13 (13.0)38 (17.2)T1116863.00 kVA250.00125.0011.50 (29.2)10.31 (26.2)7.13 (18.1)55 (24.9)T1116875.00 kVA416.00208.0014.38 (36.5)10.31 (26.2)7.13 (18.1)75 (34.0)T2116887.50 kVA625.00312.5021.19 (53.8)13.50 (34.3)10.84 (27.5)125 (56.7)T21168910.00 kVA833.00416.6021.19 (53.8)13.50 (34.3)10.84 (27.5)160 (72.6)3.75 (9.5)ACME ELECTRIC MILWAUKEE, WI 800.334.5214 acmetransformer.com3.62 (9.2)APPROX.NET WEIGHTLBS. (KG.)4 (1.8)5 (2.3)85

6SECTIONLOW VOLTAGE/VOLTAGE LIGHTINGLIGHTINGTRANSFORMERSTRANSFORMERS& POWER SUPPLIESLow Voltage Lighting Wiring DiagramsGROUP VIGROUP VH1H1H2H2240V120VX112VX1X2H1H2Voltageat Lamp13.2H2240VX2X1VOLTAGE DROP CHARTLife Expectancy% of Ratedof LampCandlepower2/3 Rated Life35024VX2240VINPUT12VOUTPUTCABLE SIZE CONSTANT CHARTCableCable UTX3X424VOUTPUTH2H1X3X4240VINPUT24VOUTPUTVOLTAGE DROP FORMULAXTotal Watts on Cable3/4 Rated Life180#162200Length of RunCable Size Constant12.0As Rated100#143500 Voltage Drop11.52X Rated Life80#12750011.03X Rated Life74#1011,92010.55X Rated Life65#818,96010.09X Rated NPUTACME ELECTRIC MILWAUKEE, WI 800.334.5214 4

SECTION LOW VOLTAGE LIGHTING TRANSFORMERS & POWER SUPPLIES 84 ACME ELECTRIC MILWAUKEE, WI 800.334.5214 acmetransformer.com 6 LOW VOLTAGE/ LIGHTING TRANSFORMERS Low Voltage General Purpose Transformers FEATURES Q UL Listed , CSA Certified. Q 100, 150, 300, 600, 750, 1000 VA. Q 1 Phase, 60 Hz, 120 or 240 volt input. Q 12 or 24 volt output. Q Input Auto-Thermal reset switch.

Related Documents:

Dec 06, 2016 · COMMERCIAL LIGHTING 01-13 14-29 industrial lighting hazardous area lighting cleanroom lighting INDUSTRIAL LIGHTING street lighting area lighting induction lighting landscape lighting CITYSCAPE LIGHTING 30-51 ballast light sources HID lamps spares price list A

LIGHTING ( DEFINED ) OPEN AREA (ANTI-PANIC) LIGHTING ( UNDEFINED ) HIGH RISK TASK LIGHTING Emergency lighting standards tree. Escape route lighting. 1.Escape Route Lighting The emergency lighting on a route forming part of the means of escape from a point in a building to final exit. 2.Open Area (Anti-panic) Lighting The part of emergency .

Small Lighting controls 20 80/22 21 Small Lighting-only 20 80/22 18 Large Lighting controls 10 80/31 10 Large Lighting-only 10 80/31 7 2013-2014 Small Lighting controls 40 80/16 42 Small Lighting-only 20 80/22 21 Large Lighting controls 30 80/18 33 Large Lighting-only 10 80/31 10 Total 160 80/15 162

2 15 ' 1 2 15 ' 2 15 ' notes: mainline 1 typ. lighting limits interchange 215' lighting limits interchange lighting limits interchange lighting limits interchange lighting limits interchange 3. 2. 1. interchange lighting limits n.t.s. reports indicates. of what that the lighting justification the mainline will be illuminated regardless

Pathway Lighting Prescolite/Hubbell Siltron Sure-Lites/Eaton Lighting solutions LIGHTING, FLOURESCENT Alera Lighting/Hubbell Apogee Translite Bartco Lighting Columbia Lighting/Hubbell Coronet Lighting Day-Brite/Philips Finelite Focal Point Lighting H.E. Williams Holophane/Acuity

Lighting Controller is connected to the lighting monitoring system to control all the lighting in the building and storing lighting control data. - Can interwork with lighting Monitoring S/W - Can control about 4,000 wireless devices Type Spec Model 9LH00B58802.ABP01E Input Voltage AC 100 220V Install site Wall or inside lighting panel

Fifty‐five percent of growers grow crops under HPS lighting; 25% grow crops under LED lighting. Growers were familiar with many LED lighting manufacturers; and had evaluated or purchased LED lighting from GE Lighting, LumiGrow, Philips Lighting, PL Light Systems and Sunlight Supply.

Second’Grade’ ’ Strand:(ReadingInformational(Text’ Topics( Standard( “Ican ”statements( Vocabulary(Key(Ideas(and(Details ’ RI.2.1.’Ask’andanswer .