Clamp-on Ammeter For AC Current

1y ago
2 Views
1 Downloads
852.49 KB
6 Pages
Last View : 1m ago
Last Download : 3m ago
Upload by : Matteo Vollmer
Transcription

Clamp-on ammeter for AC currentMINI SeriesMINI seriesSmall, compact and particularly resistant, this range ofminiature clamps is designed for measurements from afew milli-amperes to 150 A ac. Their shape makes themvery practical in confined spaces, such as circuit-breakerboards, control panels or control boxes. They are idealfor use with multimeters.This voltage output enables instruments with AC voltagecalibres to display or store current values.There is also a model with a DC voltage output.The MINI clamps give True RMS results when used witha True RMS instrument.There are two types of MINI clamps.The first type operates like a traditional current transformerand provides a current output (mA) which can be usedwith multimeters, loggers or instruments with currentcalibres.The second provides a voltage output proportional to thecurrent measured.Non-contractuel document906131099 - Ed 1 - 001.00 (1/2)

2637.50Ø 10 mm max.112.50Non-contractuel document906131099 - Ed 1 - 001.00 (2/2)

Clamp-on ammeter for AC currentMINI 01 modelCalibreSensitivityMINI Series150 A ac1 mA / A (1,000 / 1)DescriptionSmall and compact, the MINI 01 clamp-on ammeter isthe ideal complement for any multimeter to measure ACcurrents in low-power tertiary or industrial applications.If there is a current in the conductor clamped,the MINI 01 clamp is protected against overvoltagesduring disconnection from the measurement instrument.Main specifications (1)CalibreMeasurement rangeAccuracy in %150 A2 A 150 A 2.5 % 0.15 A (1 Ω load) 3 % 0.15 A (10 Ω load)Phase shiftOutput signalNot specified1 mA ac / A ac (1000 / 1)(150 mA at 150 A)Output:Double-insulated cable 1.5 m long,terminated by 2 insulated elbowed malebanana connectors Ø 4 mmBandwidth: 48 Hz 500 HzClamping capacity:Cable Ø max 10 mmElectrical specificationsLoad impedance: 10 ΩMaximum currents:I 150 A permanent from 48 Hz 500 HzInfluence of temperature: 0.2 % per 10 KInfluence of adjacent conductor: 2 mA / A at 50 HzMechanical specificationsOperating temperature:-10 C to 50 CStorage temperature:-40 C to 80 CRelative humidity for operation:from 0 to 85 % RH decreasing linearlyabove 35 COperating altitude: 0 to 2,000 mCasing protection rating (leakproofing):IP40 (2) (EN 60529 Ed. 1995)Fall height:1.5 m (IEC 68-2-32)Shock protection:100 g / 6 ms / half-period (IEC 68-2-27)Influence of conductor position in jaws: 0.1 % at 50/60 HzVibration resistance (3):5-15 Hz (1.5 mm), 15-25 Hz (1 mm),25-55 Hz (0.25 mm) (IEC 68-2-6)Influence of frequency: 2 % from 65 Hz to 500 HzSelf-extinguishing capability:casing UL94 V2Maximum output voltage(secondary open): 30 VDimensions: 130 x 37 x 25 mmSafety specificationsElectrical safety:Instrument with double insulation or reinforced insulation between the primary, thesecondary and the grippable part locatedunder the guard as per EN 61010-1Ed. 2:2001, EN 61010-2-031 Ed. 2002 &EN 61010-2-032 Ed. 2003- 600 V category III, pollution degree 2- 300 V category IV, pollution degree 2Electromagnetic compatibility:CE-certified equipment compliant withstandard EN 61326-1 (Ed. 97) A1 (Ed. 98) A2 (Ed. 01)- Emission: stipulations for Class Bequipment (domestic use).- Immunity: stipulations for equipmentused intermittently on industrial sites.Weight: approx. 180 gColours: black casing(1) Conditions of reference: 23 C 3 K, 20 to 75 % RH, sinusoidal signal with frequency of 48 Hz to 500 Hz, distortion factor 1 % with no DC component, external DC magnetic field 40 A/m, no external AC magnetic field, no external conductor with circulating current, conductor centred for measurement, measurement instrument load impedance 10 Ω.(2) With clamp closed.(3) Vibrations expressed in mm peak, scanning of 1 octave/minute for 10 minutes on 3 axes.To orderReferenceMINI 01 clamp-on AC ammeter with operating manualNon-contractuel document906131099 - Ed 1 - 01P01105101Z1.01 (1/1)

Clamp-on ammeter for AC currentMINI 03 modelCalibre100 A acSensitivity1 mV / AMINI SeriesDescriptionSmall and compact, the MINI 03 clamp-onammeter is the ideal complement for anymultimeter to measure AC currents in low-powertertiary or industrial applications.When used with an AC voltmeter, it allows youto directly read the current measured on thevoltmeter.Main specifications (1)CalibreMeasurement rangeAccuracy in %Phase shiftOutput signal100 A1 A 100 A 2 % 50 mANot specified1 mA ac / A ac(100 mV at 100 A)Output:Double-insulated cable 1.5 m long,terminated by 2 insulated elbowedmale banana connectors Ø 4 mmBandwidth: 48 Hz 500 HzClamping capacity:Cable Ø max 10 mmElectrical specificationsMechanical specificationsOperating temperature:-10 C to 50 CStorage temperature:-40 C to 80 CRelative humidity for operation:0 to 85 % RH decreasing linearly above 35 COperating altitude:0 to 2,000 mMaximum currents:I 150 A permanent from 48 Hz 500 HzCasing protection rating (leakproofing):IP40 (2) (EN 60529 Ed.1995)Influence of temperature: 0.2 % per 10 KFall height: 1.5 m (IEC 68-2-32)Influence of adjacent conductor: 2 mA / A at 50 HzShock protection:100 g / 6 ms / half-period (IEC 68-2-27)Influence of conductor position in jaws: 0.1 % at 50/60 HzVibration resistance (3):5-15 Hz (1.5 mm), 15-25 Hz (1 mm),25-55 Hz (0.25 mm) (IEC 68-2-6)Influence of frequency: 1 % from 65 Hz to 500 HzSelf-extinguishing capability:casing UL94 V2Safety specificationsElectrical safety:Instrument with double insulation or reinforced insulation between the primary, thesecondary and the grippable part locatedunder the guard as per EN 61010-1Ed. 2:2001, EN 61010-2-031 Ed. 2002 &EN 61010-2-032 Ed. 2003- 600 V category III, pollution degree 2- 300 V category IV, pollution degree 2Electromagnetic compatibility:CE-certified equipment compliant withstandard EN61326-1 (Ed. 97) A1 (Ed. 98) A2 (Ed. 01)- Emission: stipulations for Class Bequipment (domestic use).- Immunity: stipulations for equipmentused intermittently on industrial sites.Dimensions: 130 x 37 x 25 mmWeight: approx. 180 gColours: black casing(1) Conditions of reference: 23 C 3 K, 20 to 75 % RH, sinusoidal signal with frequency of 48 Hz to 500 Hz, distortion factor 1 % with no DC component, external DC magnetic field 40 A/m, no external AC magnetic field, no external conductor with circulating current, conductor centred for measurement, measurement instrument load impedance 10 kΩ.(2) With clamp closed.(3) Vibrations expressed in mm peak, scanning of 1 octave/minute for 10 minutes on 3 axes.To orderReferenceMINI 03 clamp-on AC ammeter with operating manualNon-contractuel document906131099 - Ed 1 - 02P01105103Z1.02 (1/1)

Clamp-on ammeter for AC currentMINI 05 modelCalibresSensitivities10 A ac100 A ac1 mV / mA1 mV / AMINI SeriesDescriptionSmall and compact, the MINI 05 clamp-on ammeter isthe ideal complement for any multimeter to measure ACcurrents in low-power tertiary or industrial applications.With its 2 calibres, it offers excellent resolution formeasuring AC intensities from 5 mA to 100 A.Main specifications (1)CalibreMeasurement rangeAccuracy in %Phase shiftOutput signal10 A5 mA 10 A 3 % 0.15 mA100 A1 A 100 A 2 % 50 mANot specified1 mV ac / mA ac(10 V at 10 A)Output:Double-insulated cable 1.5 m long,terminated by 2 insulated elbowed malebanana connectors Ø 4 mmBandwidth: 48 Hz 500 HzClamping capacity:Cable Ø max 10 mm1 mV ac / A ac(100 mV at 100 A)Mechanical specificationsOperating temperature:-10 C to 50 CStorage temperature:-40 C to 80 CRelative humidity for operation:0 to 85% RH decreasing linearly above 35 CElectrical specificationsMaximum currents:100 A calibre:I 150 A permanent from 48 Hz 500 Hzn 10 A calibre:I 15 A permanent from 48 Hz 500 HznInfluence of temperature: 0.2 % per 10 KInfluence of adjacent conductor: 2 mA / A at 50 HzInfluence of conductor position in jaws: 0.1 % at 50/60 HzInfluence of frequency:n 100 A calibre: 1 % from 65 Hz to 500 Hzn 10 A calibre: 3 % from 65 Hz to 500 HzOperating altitude:0 to 2,000 mCasing protection rating (leakproofing):IP40 (2) (EN 60529 Ed.1995)Fall height: 1.5 m (IEC 68-2-32)Shock protection:100 g / 6 ms / half-period (IEC 68-2-27)Vibration resistance (3):5-15 Hz (1.5 mm), 15-25 Hz (1 mm),25-55 Hz (0.25 mm) (IEC 68-2-6)Safety specificationsElectrical safety:Instrument with double insulation or reinforced insulation between the primary, thesecondary and the grippable part locatedunder the guard as per EN 61010-1Ed. 2:2001, EN 61010-2-031 Ed. 2002 &EN 61010-2-032 Ed. 2003- 600 V category III, pollution degree 2- 300 V category IV, pollution degree 2Electromagnetic compatibility:CE-certified equipment compliant withstandard EN61326-1 (Ed. 97) A1 (Ed. 98) A2 (Ed. 01)- Emission: stipulations for Class Bequipment (domestic use).- Immunity: stipulations for equipmentused intermittently on industrial sites.Self-extinguishing capability:casing UL94 V2Dimensions: 130 x 37 x 25 mmWeight: approx. 180 gColours: black casing(1) Conditions of reference: 23 C 3 K, 20 to 75 % RH, sinusoidal signal with frequency of 48 Hz to 500 Hz, distortion factor 1 % with no DC component, external DC magnetic field 40 A/m, no external AC magnetic field, no external conductor with circulating current, conductor centred for measurement, measurement instrument load impedance 1 MΩ (10 Acalibre) & 10 kΩ (100 A calibre).(2) With clamp closed.(3) Vibrations expressed in mm peak, scanning of 1 octave/minute for 10 minutes on 3 axes.To orderReferenceMINI 05 clamp-on AC ammeter with operating manualNon-contractuel document906131099 - Ed 1 - 03P01105105Z1.03 (1/1)

Clamp-on ammeter for AC currentMINI 09 modelCalibreSensitivityMINI Series150 A ac1 mV dc / A acDescriptionSmall and compact, the MINI 09 clamp-on ammeter isthe ideal complement for any multimeter to measure ACcurrents in low-power tertiary or industrial applications.Its DC voltage output helps to overcome the low sensitivityof certain AC measurement instruments.Main specifications (1)CalibreMeasurement rangeAccuracy in %150 A1 A 5 A 10 % 0.2 A5 A 15 A 6 % 0.2 APhase shiftOutput signal15 A 40 A 3 % 0.2 A40 A 150 A 4%Not specified100 mV dc / A ac (15 V dc at 150 A)Output:Double-insulated cable 1.5 m long,terminated by 2 insulated elbowedmale banana connectors Ø 4 mmBandwidth: 48 Hz 500 HzClamping capacity:Cable Ø max 10 mmElectrical specificationsMechanical specificationsOperating temperature:-10 C to 50 CStorage temperature:-40 C to 80 CRelative humidity for operation:0 to 85% RH decreasing linearly above 35 COperating altitude:0 to 2,000 mMaximum currents:I 150 A permanent from 65 Hz 500 HzCasing protection rating (leakproofing):IP40 (2) (EN 60529 Ed.1995)Influence of temperature: 0.2 % per 10 KFall height: 1.5 m (IEC 68-2-32)Influence of adjacent conductor: 2 mA / A at 50 HzShock protection:100 g / 6 ms / half-period (IEC 68-2-27)Influence of conductor position in jaws: 0.1 % at 50/60 HzVibration resistance (3):5-15 Hz (1.5 mm), 15-25 Hz (1 mm),25-55 Hz (0.25 mm) (IEC 68-2-6)Influence of frequency: 3 % from 65 Hz to 500 HzSelf-extinguishing capability:casing UL94 V2Safety specificationsElectrical safety:Instrument with double insulation or reinforced insulation between the primary, thesecondary and the grippable part locatedunder the guard as per EN 61010-1Ed. 2:2001, EN 61010-2-031 Ed. 2002 &EN 61010-2-032 Ed. 2003- 600 V category III, pollution degree 2- 300 V category IV, pollution degree 2Electromagnetic compatibility:CE-certified equipment compliant withstandard EN61326-1 (Ed. 97) A1 (Ed. 98) A2 (Ed. 01)- Emission: stipulations for Class Bequipment (domestic use).- Immunity: stipulations for equipmentused intermittently on industrial sites.Dimensions: 130 x 37 x 25 mmWeight: approx. 180 gColours: black casing(1) Conditions of reference: 23 C 3 K, 20 to 75 % RH, sinusoidal signal with frequency of 48 Hz to 500 Hz, distortion factor 1 % with no DC component, external DC magnetic field 40 A/m, no external AC magnetic field, no external conductor with circulating current, conductor centred for measurement, measurement instrument load impedance 50 kΩ.(2) With clamp closed.(3) Vibrations expressed in mm peak, scanning of 1 octave/minute for 10 minutes on 3 axes.To orderReferenceMINI 09 clamp-on AC ammeter with operating manualNon-contractuel document906131099 - Ed 1 - 04P01105109Z1.04 (1/1)

Electrical specifications Maximum currents: I 150 A permanent from 48 Hz (2)500 Hz Influence of temperature: 0.2 % per 10 K Influence of adjacent conductor: 2 mA / A at 50 Hz Influence of conductor position in jaws: 0.1 % at 50/60 Hz Influence of frequency: 1 % from 65 Hz to 500 Hz Mechanical specifications Operating .

Related Documents:

BC1 Page 41 BEAM CLAMP BD1 Page 41 BEAM CLAMP BF1 Page 42 BEAM CLAMP BG1 Page 42 BEAM CLAMP BH1 Page 42 BEAM CLAMP BF2 Page 42 BEAM CLAMP BG2 Page 42 BEAM CLAMP BL FLANGE CLAMP Page 43 GRATE FIX Page 44 BEAM CLAMP GRATING CLIP Page 45 BEAM CLAMP FLOORFIX HT Page 46 FLOORFIX Page

To minimize error, ammeter resistance r must be very small. (ideal ammeter would have zero resistance) any ammeter has . some resistance r. r connect ammeter in series Are we measuring the correct current? (the

price in CHF Elbro DM 6015 Current Clamp Meter 125.- 1630 Earth Ground Clamp 125.- i200 Current Clamp 95.- 336 Current Clamp 125.- 337 True RMS Clamp Meter 125.- i410 AC/DC Current Clamp 125.- T5-600 Current Clamp Meter 100.- T5-1000 Current Clamp Meter 125.- Gossen Metr

Bruksanvisning för bilstereo . Bruksanvisning for bilstereo . Instrukcja obsługi samochodowego odtwarzacza stereo . Operating Instructions for Car Stereo . 610-104 . SV . Bruksanvisning i original

Ammeter It is a device to measure current in a circuit. A galvanometer is converted into an ammeter by connecting a small resistance in parallel ( also called the shunt resistance ) to the galvanometer A real ammeter has a low resistance. An ideal

Q.5 In ac circuit when ac ammeter is connected it reads i current if a student uses dc ammeter in place of ac ammeter the reading in the dc ammeter will be: (1) 2 i (2) 2 i (3)0.637i (4*)zero Q.6 In an AC generator, a coil with N turns, all of the same area A and total resistance

100A - 470 500 690 Non Standard Ammeter/Other than above ranges (upto 100A) 660 600 630 880 . BAR etc. This is a surcharge for non standard scale along with the meter price LP surcharge Ammeter (x1) (without suppression) Ammeter (x2) or (x3) suppression (for EQ meters only) Ammeter (x5) or (x6) suppression (for EQ meters only)

Jan 01, 2021 · 100A - 475 505 695 Non Standard Ammeter/Other than above ranges (upto 100A) 665 605 635 885 . This is a surcharge for non standard scale along with the meter price LP surcharge 40 Ammeter (x1) (without suppression) Ammeter (x2) or (x3) suppression (for EQ meters only) Ammeter (x5) or (x6) suppression (for EQ meters only) 30