SeriesRZPACKAGED ROOFTOP UNITS ANDOUTDOOR AIR HANDLING UNITSFeatures: 45-240 tons 7,500-80,000 cfmAir-cooled condenser or water-cooled condenserpackaged rooftop units from 45-240 tonsEvaporative condenser packaged rooftopunits from 51-261 tonsWater-source, geothermal and air-sourceheat pump optionsChilled water or non-compressorized DXair handling units, from 7,500 - 80,000 cfmR-410A variable speed scroll compressorsDouble wall rigid polyurethane foam insulatedcabinet constructionWalk-in compressor and control service vestibuleUnit access doors with full length hinges andlockable handlesDirect drive welded air-foil plenum supply fansBlow-through and draw-through supply fanconfigurationsElectric, steam, hot water, indirect fired gas,and direct fired gas heatingPower exhaust and power return plenumfan optionsFactory installed AAONAIRE sensible and totalenergy recovery wheelsHumidity control features including return airbypass and modulating hot gas reheatOption boxes available with optional drain panfor field installed componentsHigh Efficiency Final Filters includingunits with gas heat.Application FlexibilityMinimizes Installation Time and Reduces Labor CostUp to 100% Outside AirDehumidication andFiltration CapabilitiesEasy to Install and ServiceCustom Quality Construction

SeriesRZRooftop/Air HandlersAAON continuously strives to satisfy thedynamic industry requirement for largeenergy efficient packaged rooftop equipment.The RZ Series design incorporates the AAONlong term commitment and dedication toexcel as the premier manufacturer of rooftopequipment. RZ Series units are available inmultiple configurations and include manystandard features that make AAON synonymouswith quality products for any application.Premium EfficiencyCompressorsThe RZ Series Packaged Rooftop Unit includes variable speed compressors asstandard. Each interlaced evaporator coil includes one circuit with VFD variablespeed compressor for consistent air temperature across the face of the coil at alloperating conditions. During part load operation, reducing compressor capacitysaves system operating costs. The variable speed compressors use inverter drivenpermanent magnet motors for down to 11% unit turndown on some models. IEERpart load efficiencies for the RZ Series can be as high as 18.7.Variable Speed CompressorsProvide consistent supply air temperaturecontrol, load matching cooling, and highpart load efficiency.Supply FansThe RZ Series offers supply fan arrays with up to 12 fans using high efficiency directdrive airfoil plenum fans with optional permanent magnet motors. In the past whengreater airflows were required, the diameter of the single plenum fan was simplyincreased to meet the requirement. This resulted in higher tip speeds, which alsomeant higher sound levels. With the AAON RZ Series, greater airflow rates can beaccomplished with multiple fans of smaller diameter, which inherently will bequieter than a single larger diameter fan. All the fans are also directly driven bythe motor, which eliminates the drive belt assembly and associated maintenance.Supply Fan ArrayProvides quiet high efficiency operation with low maintenanceand built-in redundancy. Backdraft dampers are available.

The Benefits of Permanent Magnet Motor Technology versus AC Induction MotorsThe RZ Series supply fan array is designed around new permanentmagnet motor technology. These hybrid motors incorporate asynchronous reluctance rotor with permanent magnets to achieve anInternational Efficiency rating above IE5, which is the highest levelof efficiency today. The example chart below shows that this HybridPermanent Magnet Motor has the highest efficiencies at all loadconditions compared with the Electronically Commutated Motor (ECM)and the Premium Efficiency Induction Motor. The advantages of theHybrid Permanent Magnet Motor are even more significant at thelower fan speeds. Notice how much more efficient the HybridPermanent Magnet Motor is at reduced load (rpm) where variable airflow fans will operate during a majority of the time. Another advantageof this motor technology is it uses standard NEMA frames, which givesmore flexibility for replacement than proprietary designs.95%90%IE5)otor (net MMotor Efficiency85%HybridPermronicElect80%t Maganenotored Mutatommally C75%70%65%60%88011001320Application FlexibilityAAON has always offered a large number of features onour products to allow for application flexibility. A poolapplication might require interior corrosion protection forthe unit, e-coated coils, power exhaust, TEFC motors, phaseand brown out protection, and modulating hot gas reheat fordehumidification control. A school application might require Multiple methods of humidity control including:High Capacity Cooling Coils, Return Air Bypass, andModulating Hot Gas Reheat Humidity Control, whichprovides precise dehumidification, even with lowsensible heat loads, without the temperature swingscommon with on/off reheat systems.Multiple high efficiency filtration options, including pleated,cartridge, or bag type, with up to MERV 14 efficiency rating.HEPA filters available for applications that require it.Factory installed total and sensible AAONAIRE energyrecovery wheels save cooling and heating dollars.Return fans are available for high return static applications.Factory installed, sensible or enthalpy controlled,AMCA Certified Class 2 low leakage gear driveneconomizer dampers allow for free cooling.LED Marine service lights for quick and convenientmaintenance.1540176019802200Speed (RPM)additional fresh outside air so an energy recovery wheel canbe added to temper the outside air and save energy. AAONRZ Series also includes an option box feature with differentlengths and locations to allow even more flexibility. See thefollowing for some other options available: Double pane viewing windows can be installed in all doorswhere viewing of operating equipment or interior cabinetis needed.Polymer e-coated coils are available to extend the life of thecoils and protect them in corrosive environments.Interior corrosion protection option protects interiorcomponents of the unit in corrosive environments.Option boxes are segments of the unit that can be left emptyfrom the factory so that components may be installed inthe field without the trouble of installation and service ina crowded cabinet. The option box can be selected with orwithout drain pan.And many more selectable factory installed options to meetnearly any application’s needs.

RZ Series FeaturesMicrochannel Air-CooledCondenser CoilsMicrochannel condenser coils are moreefficient, lighter, and use less refrigerant thantraditional fin and tube condenser coils.Gas HeatHeat exchangers are constructed from 304 stainless steel witha dimpled heat exchanger design that eliminates the need forinternal turbulators, maximizing efficiency and reducing serviceissues. Up to 4500 MBH of heat is available with staged andmodulating control.Variable Speed CompressorsProvide consistent supply air temperaturecontrol, load matching cooling, and highpart load efficiency.Walk-In Service VestibuleThe walk-in service vestibule provides shelter for the maintenanceand service personnel while startup and periodic maintenance isperformed on the unit. Lighting is furnished in the compartment,controlled by a light switch at the door, convenience outlet can beprovided, and the vestibule can be heated for comfort.Final Filters with Gas HeatFinal filters are available with up to MERV 14media, including units with gas heat.Supply Fan Array DesignState-of-the-art computer simulations and laboratory testing were utilizedto design motor mount frames with minimal vibration and sound. Each fanmodule is built on a dedicated assembly line with auto laser cutting and robotwelding for a consistent, high quality product. Fan modules are powder coatedfor corrosion protection.

Superior Features Variable speed scroll compressors are standard for load matchingcooling and high part load efficiency. Variable speed circuits coverthe full-face area of the evaporator coil for consistent control.Aluminum tread plate floor covering within the vestibule forimproved durability and safety.Selectable number of draw-through or blow-through direct drivebackward airfoil curved plenum fans allows designflexibility for quieter applications and redundancy forapplications where unit up time is critical. Corrosion resistant polyurethane paint exceeds a 2,500-hoursalt spray test. Refrigerant circuits are provided with removable core filter driers withisolation valves for ease of service; no need to cut the refrigerant lineas is done with brazed in filters. Unit specific color-coded wiring diagrams are laminated andpermanently affixed inside the control compartment for ease of service. Compressor isolation valves are standard for improved service efficiency. 5 year non-prorated compressor warranty.Optional Exhaust and Return FansPlenum power exhaust and return fans aredirectly driven by the motor.Evaporator CoilsEach evaporator coil circuit has an electronicexpansion valve. Variable speed circuitscover the full-face area of the evaporator coilfor consistent air temperatures. Double slopedstainless steel drain pan is provided for positivedrainage. Intermediate drain pans are provideon units with upper and lower coils. Tubing isdressed and structurally supported.AAONAIRE Energy Recovery WheelThis energy recovery ventilation option can be provided inall model sizes allowing reduced equipment size andoperating cost savings while pre-conditioning the outsideair being introduced into the conditioned space.Service Access DoorsWalk-in hinged access doors with lockable handlesfor easy servicing of all sections of the unit withoptional view port windows.Double Wall Rigid PolyurethaneFoam Panel ConstructionAAON two-inch wall panel has a thermal resistanceof R-13 and includes thermal breaks to reduce heattransfer through the cabinet. The double-wall panelconstruction dampens radiated compressor and fansound and inhibits microbial growth, supportingindoor air quality.EconomizerFactory installed, sensible or enthalpycontrolled AMCA certified Class 2 lowleakage gear driven dampers allow forfree cooling and indoor air quality control.

Air-Cooled, Water-Cooled, or Evaporative CondensersRZ Model (Nominal Capacity, 5161160172180197200221220241240261Compressor TypeCompressors / CircuitsWidth4/3100HeightLength104Length variesdepending on optionsselected.(2) R-410A Variable SpeedScroll(1) TandemR-410A Scroll(4) R-410AVariable Speed Scroll8/6142(2) TandemR-410A ScrollAll dimensions are in inches.WHLAir-Cooled CondensingMicrochannel condenser coils are more efficient due to their enhancedheat transfer. They are also up to 60 percent lighter and use lessrefrigerant than traditional fin and tube coils. All condenser coils aredesigned for at least 10 F of refrigerant sub-cooling. VFD is factoryinstalled on the condenser fans for head pressure control and greateroperating temperature range, as well as to provide reduced sound levelsat off design ambient temperatures. All condenser fans are direct drive,axial flow propeller type, and discharge vertically.Evaporative CondenserThese units deliver both outstanding energy efficiencyand significant operational cost savings when comparedto air- cooled designs. Energy cost reduc tion canbe 20% to 40% annually depend on application andgeographic location. Locations that commonly require acentral chiller and cooling tower are primary locations forapplication of the evaporative condenser RZ Series rooftop unit.Factory installed AAON evaporative condenser, with air-cooleddesuperheater and low sound ECM driven variable speedcondenser fans, can use 22-100% less water than a conventionalevaporative condenser, and require 22-100% less chemical usagethan a conventional evaporative condenser. Interior of evaporativecondenser is constructed of 304 stainless steel and othernon-corrosive materials. Desuperheater coils include polymere-coating for corrosion protection.Air-Handling UnitsWater-Cooled CondensingThe RZ Series also fits the job when units are required without compressors.The unit will be built without a condensing section and walk-in compressorand control vestibule. All other features and options are readily available.Air handling units may include the following options:Highly energy efficient water-cooled units are of particularapplication value when cooling tower water is available. Thestandard water-cooled RZ Series units include these features: Supplied with a DX coil and expansion valves.Supplied with a chilled water coil in 4, 6, or 8 rows.The unit may be specified with any of the heating options toprovide a year-round rooftop heating and cooling package. Shell and tube refrigerant-to-water heat exchangers.Each heat exchanger is provided with a removableand cleanable type basket filter.Heat exchanger piping connections are made withinthe condensing section of the roof top unit.

Heating OptionsFan SelectionThe RZ Series can be configured as either a draw-through or blow-through arrangement with supply or return fans. The supply blowerassemblies are direct drive, unhoused, single inlet, single width, fans. AAON ECat selection software easily allows selection for constantor variable air flow applications. The software determines the most efficient alternatives for the application as a function of fan quantity,fan diameter, fan blade width, and rpm.Inlet and outlet sound ratings are provided for each combination of fans and unit inlet and outlet sound ratings are determined forthe overall unit configuration. Multiple fans can provide improved reliability, greater efficiency, lower sound levels, and greater serviceoptions.Gas HeatElectric HeatAll 304 stainless steel design construction assures dependable,long term functionality. Through elimination of the need forinternal turbulators, this unique design reduces service issues,and increases capacity and efficiency. Individual RZ Series gasheat exchanger modules are designed for 350 MBH and 400MBH input rates and can be configured for up to a 4500 MBHtotal gas input rating on the largest cabinet size. High turndown modulating gas heat provides greater fuel efficiency andimproved occupancy comfort. Final filters are allowable on theRZ Series gas heat units.Electric resistance heating elements are open type withlow watt density nickel chromium. The heating modulesare 40 kW with individual circuit fusing and a manuallyreset high temperature limit switch. SCR (Silicon ControlledRectifier) electric heat control for supply air temperature controlreduced power consumption, longer heater life and improvedoccupant comfort.Hot Water and Steam Heat CoilsHot water and steam coils are available in 1 or 2 rowconfigurations with multiple different face areas to meet jobrequirements.Hot Water or Steam Preheat CoilsWhen jobsite conditions require, coils are available toprecondition the outside air. 1 or 2 row hot water or steamcoils may be supplied to match the system requirements.

(3-70 tons)(800 - 80,000 cfm)RQ SeriesRN SeriesChiller and Packaged OutdoorMechanical Rooms (4-478 tons)Self-Contained UnitsOutdoor Air Handling UnitsRZ SeriesSB SeriesWater-Source Heat PumpsWH Series &WV Series(2-70 tons)(800 - 50,000 cfm)V3 SeriesRN SeriesRQ SeriesSA SeriesCF SeriesCB SeriesH3 SeriesF1 SeriesLZ SeriesCondensing UnitsIndoor Air Handling Units(½ - 230 tons)LN SeriesLF SeriesM2 SeriesSA SeriesPackaged Rooftop UnitsSB Series(2-240 tons)M2 SeriesRZ SeriesSA SeriesCoils BOOSTER, HYDRONIC, and DXM2 SeriesRQ SeriesRN SeriesControls(WSHP, RTU,SELF-CONTAINED,SPLIT SYSTEM, & CHILLER)Heating and Cooling for.AuditoriumsConvenience StoresHealth ClubsHealth Care FacilitiesHomesLodgingsManufacturingMuseums & LibrariesNatatoriumsOffice BuildingsRestaurantsRetail StoreSchoolsSupermarkets2425 S. Yukon Ave.Tulsa, OK 74107-2728www.AAON.comIt is the intent of AAON to provide accurate and current product information. However, in the interest of product improvement, AAON reserves the right to change pricing,specifications, and/or design of its product without notice, obligation, or liability. Copyright AAON, all rights reserved throughout the world. AAON and AAONAIRE areregistered trademarks of AAON, Inc., Tulsa, OK.RZ Series V62360 210210RZ Series

Up to 100% Outside Air Dehumidication and Filtration Capabilities Easy to Install and Service Custom Quality Construction Features: Air-cooled condenser or water-cooled condenser packaged rooftop units from 45-240 tons Evaporative condenser packaged rooftop units from 51-261 tons Water-source, geothermal and air-source heat pump options

Related Documents:

Packaged Rooftop Air Conditioners Voyager Cooling and Gas/Electric 12½–25 Tons, 60 Hz . Packaged Rooftop Air Conditioners Through the years, Trane has designed and developed the most complete line of Packaged Rooftop products available in the market today. Trane was the first to introduce the Micro— . † Manual Outside Air Dampers .

Zoned Rooftop Systems p. 3 Zoned Rooftop System Confi gurations p. 4 Systems comparison p. 10 Application considerations p. 12 Equipment with controls: Light commercial rooftop units p. 28 Equipment with controls: VAV terminal units p. 35 Equipment with controls: Bypass damper p. 37 Sensors p. 38 System level control p. 40 Specifi cations p. 44

Packaged Rooftop Air Conditioners Through the years, Trane has designed and developed the most complete line of Packaged Rooftop products available in the market today. Trane was the first to introduce the Micro—microelectronic unit controls—and has continued to improve and revolutionalize this design concept. The Relia Tel control platform .

2020 Trane RT-PRC073E-EN Introduction Packaged Rooftop Air Conditioners Through the years, Trane has designed and developed the most complete line of Packaged Rooftop products available in the market today. Trane customers demanded a product that provided exceptional reliability, was easy to install, and was competitively priced.

THE ROOFTOP (RE) SERIES The RE series WSHP rooftop units offer high effi ciency at competitive prices for applications where outdoor equipment is required. The RE series meets ASHRAE 90.1 effi ciencies and is up to 40% more effi cient that typical air source rooftop units. Available in sizes 3 tons (10.6 kW) through 20 tons (70.3

Energence Ultra-High Efficiency Packaged Electric / Electric 7.5 to 12.5 Ton / Page 2 FEATURE HIGHLIGHTS CONTENTS Lennox' Energence Ultra- High Efficiency packaged rooftop unit product line was created to save energy with intelligence by offering some of the highest energy efficiency ratings available with a powerful, easy to use unit controller.

Packaged Rooftop Air Conditioners Through the years, Trane has designed and developed the most complete line of Packaged Rooftop products available in the market today. Trane was the first to introduce the Micro—microelectronic unit controls—and has continued to improve and revolutionalize this design concept.

on the work of its forty-seventh session, which was held in New York, from 7-18 July 2014, and the action thereon by the United Nations Conference on Trade and Development (UNCTAD) and by the General Assembly. In part two, most of the documents considered at the forty-seventh session of the Commission are reproduced. These documents include .