Polypropylene Total Exhaust Fume Hoods 24 36 48 60 72 96

1y ago
18 Views
2 Downloads
956.72 KB
5 Pages
Last View : 18d ago
Last Download : 3m ago
Upload by : Shaun Edmunds
Transcription

SERIESPolypropylene Total Exhaust Fume Hoods“Provides Comprehensive Operator Protection and Optimum Performance”24 36 4860 72 96— PTEFH-48 shown on optionalvented base cabinetProvides Personnel Protectionfrom Airborne HazardsMeets or Exceeds OSHA, ANSI andother International Standards

SERIESp:2Polypropylene Total Exhaust Fume HoodsProduct Overview24 36 48 60 72 96JUMP TO:SERIESFeaturesand Callouts (p.3)Polypropylene Total Exhaust Fume HoodsSpecifications (p.4)White, black or blue all-polypropylene work surface.Options andAccessories (p.5)Units available with up to four exhaust connection points.Vapor-proof, ballasted fluorescent lightingwith switch and power cord.Integrated rear baffle system optimizes airflowand improves containment.Acrylic, bi-fold front sash to ensure operator safetyand comfort.Two cable pass through ports provide convenientworkspace configuration options.Air Velometer provides continuous airflow monitoring.PTEFH-60INTRODUCTIONAir Science TotalExhaust fume hoodsVENTED BASE CABINETare designed to provide superiorThe optional ventedbase cabinet safelystores chemicals, andcan be fitted with cupsink, swan neck faucetand service fixtures.personnel protection from exposureAPPLICATIONSto hazardous agents and toxic Forensicschemicals in a variety of applications. EducationalTotalExhaust fume hoods use horizontal Microscopyand vertical airflow across the work Pharmaceutical Powder weighing Sample prep work Veterinary anddental worksurface to ensure optimal containment.Corrosion-resistant, single-wall unitsAVAILABLE OPTION:EXHAUST BLOWERSsizes and configurationsto withstand the mostdemanding conditions.Chemical and corrosionresistant plastic impellerand casing constructionare suitable for installation in highly causticconditions as well asgeneral laboratory use.Optional polypropyleneexhaust blowers areavailable in a variety ofare available in a number of standardand custom sizes with optional polypropylene exhaust blowers to augmentTOTALEXHAUSTAIRFLOW PATTERNexternal ventilation systems. ContactAir Science for more information.Connectionto DuctworkRoomAir IntakePTEFH-40Made inthe U.S.A.This Product Exceeds OSHA, ANSI and Other International Standards.Ductwork(not included)

SERIESp:3Polypropylene Total Exhaust Fume HoodsProduct Features24 36 48 60 72 96PRODUCT FEATURES:BA. Work Surface: Seamless polypropylene work surface.Stainless steel and epoxy options also available.CB. Exhaust Connection Collar: Standard 6-inch exhaustcollar (up to 4 connections depending on model).C. Power Switch: On/Off power switch for internal lighting.D. Double Hinged Self Locking Front Sash: Easy toopen bi-fold acrylic front sash. Additional constructionmaterials available as options.E. Internal Baffle System: Integrated internal baffle systemHensures smooth airflow and optimized containment.F. Air Velometer: Analog air velocity meter allowscontinuous visual inspection of airflow for operator safety.DG. Pass Through Ports: Side-wall mounted pass throughFports for safe routing of instrument cords, cables and leads.H. Lighting: Ballasted, vapor-proof fluorescent lightingsaves energy and provides optimal internal lightingconditions.EPTEFH-24 shown with all standard features.GAAir Science 120 6th Street Fort Myers, FL 33907 T/239.489.0024 Toll Free/800.306.0656 F/800.306.0677 www.airscience.com

SERIESp:4Polypropylene Total Exhaust Fume HoodsProduct L24 36 48 60 72 96PTEFH-72PTEFH-96DIMENSIONSSide ViewWEIGHT (lbs/Kg)Internal HeightI n t e r n a l DepthExternal ( W x D x H)Shipping ( W x D x H )NetShipPTEFH-2436"914 mm23.2"590 mm24" x 28" x 47"610 x 711 x 1194 mm36" x 36" x 60"914 x 914 x 1524 mm132 / 60177 / 80PTEFH-3636"914 mm23.2"590 mm36" x 28" x 47"914 x 711 x 1194 mm48" x 42" x 60"1219 x 1067 x 1524 mm156 / 71201 / 91PTEFH-4836"914 mm23.2"590 mm48" x 28" x 47"1219 x 711 x 1194 mm55" x 42" x 60"1397 x 1067 x 1524 mm180 / 82225 / 102PTEFH-6036"914 mm23.2"590 mm60" x 28" x 47"1524 x 711 x 1194 mm68" x 42" x 60"1727 x 1067 x 1524 mm204 / 93249 / 113PTEFH-7236"914 mm23.2"590 mm72" x 28" x 47"1829 x 711 x 1194 mm80" x 42" x 60"2032 x 1067 x 1524 mm234 / 106289 / 131PTEFH-9636"914 mm23.2"590 mm96" x 28" x 47"2438 x 711 x 1194 mm105" x 42" x 60"2667 x 1067 x 1524 mm360 / 163450 / 204TotalExhaust Fume HoodsPRODUCT SPECIFICATIONSAir Science ModelPTEFH-24PTEFH-36PTEFH-48 Airflow PatternPTEFH-60PTEFH-72PTEFH-96Horizontal and vertical airflow Construction Unit Work SurfaceSashExhaust Connections(6-inch std. size)Polypropylene Polypropylene (available in White, Black or Blue) Single, double hinged locking acrylic.111Dual, double hinged locking acrylic.223*Specifications subject to change without notice.Air Science 120 6th Street Fort Myers, FL 33907 T/239.489.0024 Toll Free/800.306.0656 F/800.306.0677 www.airscience.com

SERIESp:5Polypropylene Total Exhaust Fume HoodsProduct Options24 36 48 60 72 96PRODUCT SPECIFICATIONSElectricaland MonitoringLightingPTEFH-24 f, ballasted fluorescent lighting with mounted On/Off switch and power cord (110V 60Hz; also available in other voltages). Switches MonitoringLighting, push switch On/Off. Continuous airflow display meter, wall mounted. *Specifications subject to change without notice.OPTIONS & ACCESSORIESAir Science ModelWork SurfaceWall ConstructionStainless steel or epoxy resin worktops.Slide out for easy cleaning.Clear acrylic side and rear walls provideincreased visibility.Service ValvesCan be fitted with service fixtures suchas petcocks, faucets, and valves.Cup SinkCup sink is fitted into base tray.Trash ChutesSide mounted trash chutes. Bags notincluded.Vented Base CabinetsFloor-standing vented base for cabinet.Provides safe storage of chemicals orother materials.Sash ConfigurationIncludes overlapping sliding doors(vertical or horizontal), vertical outwardswing doors and various hinged upwardswing configurations.Exhaust BlowersSingle block, high density UV-treatedand recyclable polypropylene unitsavailable in various sizes and mountingconfigurations to external ventilationsystems to vacate contaminated -TE-60CREAR-TE-72CREAR-TE-96 SF-X. Specify service fitting type (faucet, valve, petcock)and location when ordering. 0ENCVBPTEFH-72ENCVBPTEFH-96ENCVB Contact Air Science to discuss specific door options and configurationson each model of TotalExhaust fume hood. Multiple sizes and mounting configurations are available. STANDARDS & COMPLIANCEQuality Management SystemsISO 9001Chemical Fume ContainmentANSI/ASHRAE 110 1995Electrical SafetyUL-C-61616ACE MarkROHS Exempt under EEE Category 9Product DesignANSI Z 9.5-2003ANSI Z 9.7-1998OSHA, Occupational Safetyand Health AdministrationOSHA Standard -29 CRF, Safety and Health Regulationsfor General Industry, 1910.1450; Occupational exposureto hazardous chemicals in laboratories. Part B, definition,laboratory type hood.EnvironmentISO 14001Energy Star Partner120 6th Street Fort Myers, FL 33907T/239.489.0024 Toll Free/800.306.0656 F/800.306.0677www.airscience.com 2018 Air Science OW 10409 04/18Air Science, TotalExhaust, Multiplex, and EFT are all registered trademarks of Air Science Corporation.

Cup Sink Cup sink is fitted into base tray. SINK SINK SINK SINK SINK SINK Trash Chutes Side mounted trash chutes. Bags not included. TRASH TRASH TRASH TRASH TRASH TRASH Vented Base Cabinets Floor-standing vented base for cabinet. Provides safe storage of chemicals or other materials. PTEFH-24-ENCVB PTEFH-36-ENCVB PTEFH-48-ENCVB PTEFH-60-ENCVB .

Related Documents:

Laboratory Fume Hoods Sash Closed Sash Open Sash Closed Sash Open 3 Sash Closed Sash Open Definitions BMC/Laboratory Fume Hoods Exhaust Collar -Connection between exhaust duct and Fume Hood through which all exhaust air passes. Face Velocity -Speed of air moving into Fume Hood entrance or access opening, expressed in feet per minute (FPM).

Fume hoods also provide physical protection against fire, spills, and explosion. Laboratory fume hoods only protect users when they are used properly and are working correctly. A fume hood is designed to protect the user and room occupants from exposure to vapors, aerosols, toxic materials, odorous, and other harmful substances. Fume hoods provide

Laboratory fume hoods are one of the most vital pieces of safety equipment in a working laboratory. Fume hoods are designed to safely exhaust dangerous fumes, unpleasant odors, vapors, and particulates away from the user and safely out of the building. This guide will help you safely select the best fume hood for your particular application.

flame can be used inside a ductless fume hood as long as there are no operations involving flammable or explosive vapors. If possible, ignition sources should remain outside the hood at all times. Ductless fume hoods are potential locations for fires and explosions due to the types of reactions conducted in these hoods.

Hamilton SafeAire II Fume Hood Installation Assembly Instructions For Knocked-Down Floor-Mounted Fume Hoods General – When receiving fume hood assemblies, inspect for damage immediately. If damage is noted, request the delivering carrier to note and describe damage on bill of lading prior to your signature. Notify carrier immediately and

Fume hoods are comprised of the hood itself and a sash, which is the front panel of the fume hood that can be opened and closed to maximize access and minimize airflow. When a person walks by a fume hood, turbulence can be created causing contaminants to be drawn outside the hood. Also, if the air diffuser is

Multi-Chamber Desiccator Cabinets, Adjustable Shelf 2 Powder Containment Hoods (CVEs) 25 Wafer Storage Desiccator Cabinets 4 Custom/ Specialty Exhaust Hoods 25 Drawer Desiccator Cabinets 5 Vertical Laminar Flow Hoods 26 . Ductless Fume Hoods, Portable, HEPA & Carbon Filter 21 Gowning Bench, Shoe rack, Stainless steel Cabinets 40

To be sure your fume hood is the right one for the work you’re doing, contact your local Kewaunee sales representative. Checking Fume Hood Performance To confirm that your fume hood exhaust system is working properly, you should equip the hood with an air flow monitor. Inspect both the monitor and the system periodically for malfunctions.