Auxiliary Electric Heater Interface Kit Table Of Contents ASKHTR

1y ago
7 Views
1 Downloads
785.98 KB
8 Pages
Last View : 13d ago
Last Download : 3m ago
Upload by : Aarya Seiber
Transcription

Auxiliary Electric Heater Interface kit ASKHTR Installation, Operation & Maintenance 97B0012N07 Revised: January 30, 2017 Table of Contents General Information 2 INSTRUCTIONS for 1: Boilerless INSTRUCTIONS for 2: Supplemental 2 3 Typical Wiring Diagram 4 Typical Wiring Diagram 5 Revision History 8

CLIMATEMASTER WATER-SOURCE HEAT PUMPS Aux Electric Heater Interface Kit Rev: January 30, 2017 General Information Safety Warnings, cautions, and notices appear throughout this manual. Read these items carefully before attempting any installation, service, or troubleshooting of the equipment. All work to be performed by qualified service contractor. DANGER: Indicates an immediate hazardous situation, which if not avoided will result in death or serious injury. DANGER labels on unit access panels must be observed. WARNING: Indicates a potentially hazardous situation, which if not avoided could result in death or serious injury. CAUTION: Indicates a potentially hazardous situation or an unsafe practice, which if not avoided could result in minor or moderate injury or product or property damage. NOTICE: Notification of installation, operation, or maintenance information, which is important, but which is not hazard-related. WARNING! WARNING! The installation of water-source heat pumps and all associated components, parts, and accessories which make up the installation shall be in accordance with the regulations of ALL authorities having jurisdiction and MUST conform to all applicable codes. It is the responsibility of the installing contractor to determine and comply with ALL applicable codes and regulations. WARNING! WARNING! To avoid possible injury or death due to electrical shock, open the power supply disconnect switch and secure it in an open position during installation. CAUTION! CAUTION! Use only copper conductors for field installed electrical wiring. Unit terminals are not designed to accept other types of conductors. DESCRIPTION: Kit contains 24 VDC relay, wires and harness. APPLICATION: This kit can be used for two applications: 1) For automatic changeover from heat pump heat to electric heat for boilerless applications. Also required AH Accessory Heater and unit must have DXM. Controller can be heat pump thermostat, MPC, or LON. Controller Y is connected to DXM Y, DXMLT1 sensor in unit determines if unit will operate as compressor heat or electric heat. 2 2) For supplemental electric heat when using MPC. Also required AH Accessory Heater and unit must have MPC and either CXM or DXM. W signal from MPC is connected to W on CXM/DXM. INSTRUCTIONS for 1: boilerless - use wire diagram 96B0006N39 Connect the harness to DXM-P6 (lower right corner). Note- For MPC controller- the heater relay uses the same DXM output (EH) as pulsing fault code. This feature will not be available and pulsing fault code can only be viewed at the DXM. Locate the relay within the reach of the harness wires, mark and drill two 7/64” (2.8 mm) diameter holes. Securely attach relay with two #6 screws. Connect one black and the white harness wire to each side of relay coil. Securely tape off the 2 unused harness wire terminals (red and 1 black) to prevent electrical short. Connect supplied red wire from relay - COM and to any R connection on DXM. Connect supplied white wire from relay - N.O. to AH heater – W1 Connect supplied brown wire from DXM-C to AH heater-C Connect supplied yellow wire from DXM-R to AH heater - R Remove DXM - G wire (disconnect on both ends). Connect supplied Black wire from AH heater GT to controller G output. Connect supplied gray wire from DXM-G to AH heater GU Configuring the DXM; Set dip switch S1.7 to enable (off). Set S1.8 to desired changeover 40F (off) or 50F (on). Set S1.6 and configure JW4 for your controller (see table 1). Blue wire is not used. Table 1 DXM Controller Dip Switch Clip Jumper JW4 S1.6 S1.7 Thermostat On Off No MPC Off Off Yes LON Off Off Yes C l i m a t e M a s t e r Wa t e r - S o u r c e H e a t P u m p s

THE SMART SOLUTION FOR ENERGY EFFICIENCY Aux Electric Heater Interface Kit Rev: January 30, 2017 General Information INSTRUCTIONS for 2: supplemental electric heat when using MPC. Use wire diagram 96B0006N82 Connect the harness to CXM/DXM-P6 (lower right corner). Note- For MPC controller- the heater relay uses the same CXM/DXM output (EH) as pulsing fault code. This feature will not be available and pulsing fault code can only be viewed at the CXM/DXM. Remove CXM/DXM G wire (disconnect on both ends). Connect supplied Black wire from AH heater GT to controller G output. Connect supplied gray wire from CXM/DXM-G to AH heater GU. For DXM- Set dip switch S1.6 to normal (on) and JW4 must be clipped. For CXM- Set dip switch 4 to normal (on) and JW1 must be clipped. Locate the relay within the reach of the harness wires, mark and drill two 7/64” (2.8 mm) diameter holes. Securely attach relay with two #6 screws. Connect one black and the white harness wire to each side of relay coil. Securely tape off the 2 unused harness wire terminals (red and 1 black) to prevent electrical short. Connect supplied blue wire from MPC-W to CXM/ DXM-W. Connect supplied red wire from relay- COM and to any R connection on CXM/DXM. Connect supplied white wire from relay- N.O. to AH heater –W1. Connect supplied brown wire from CXM/DXM-C to AH heater- C. Connect supplied yellow wire from CXM/DXM-R to AH heater- R c l i m a t e m a s t e r. c o m 3

CLIMATEMASTER WATER-SOURCE HEAT PUMPS Aux Electric Heater Interface Kit Rev: January 30, 2017 Typical Wiring Diagram 4 C l i m a t e M a s t e r Wa t e r - S o u r c e H e a t P u m p s

THE SMART SOLUTION FOR ENERGY EFFICIENCY Aux Electric Heater Interface Kit Rev: January 30, 2017 Typical Wiring Diagram c l i m a t e m a s t e r. c o m 5

CLIMATEMASTER WATER-SOURCE HEAT PUMPS Aux Electric Heater Interface Kit Rev: January 30, 2017 Notes: 6 C l i m a t e M a s t e r Wa t e r - S o u r c e H e a t P u m p s

THE SMART SOLUTION FOR ENERGY EFFICIENCY Aux Electric Heater Interface Kit Rev: January 30, 2017 Notes: c l i m a t e m a s t e r. c o m 7

CLIMATEMASTER WATER-SOURCE HEAT PUMPS Aux Electric Heater Interface Kit Rev: January 30, 2017 Revision History Date: Item: 01/30/17 Page 5 Relaced wiring diagram Action: 07/14/16 Logo Updated 04/15/16 Revised 08/22/12 First Published 7300 S.W. 44th Street Oklahoma City, OK 73179 Phone: 405-745-6000 Fax: 405-745-6058 climatemaster.com *97B0012N07* 97B0012N07 ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimateMaster’s Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster’s opinion or commendation of its products. ClimateMaster, Inc. 2012 8 C l i m a t e M a s t e r Wa t e r - S o u r c e H e a t P u m p s

CLIMATEMASTER WATER-SOURCE HEAT PUMPS Aux Electric Heater Interface Kit Rev: January 30, 2017 8 ClimateMaster Water-Source Heat Pumps Date: Item: Action: 01/30/17 Page 5 Relaced wiring diagram 07/14/16 Logo Updated 04/15/16 Revised 08/22/12 First Published Revision History 97B0012N07 *97B0012N07* 7300 S.W. 44th Street Oklahoma City, OK 73179 .

Related Documents:

2 Valve body KIT M100201 KIT M100204 KIT M100211 KIT M100211 KIT M100218 KIT M300222 7 Intermediate cover (double diaphragm) - - - KIT M110098 KIT M110100 KIT M110101 4 Top cover KIT M110082 KIT M110086 KIT M110092 KIT M110082 KIT M110082 KIT M110082 5 Diaphragm KIT DB 16/G KIT DB 18/G KIT DB 112/G - - - 5 Viton Diaphragm KIT DB 16V/S KIT

Heater Heater Kit 3-Pkgd. Units Electric Heater KW No. of Breakers Electric Code H 240-1-60 Stages Q7RD Heater Kit Application Matrix Tonnage Nominal kW Heater Kit Model Heater Kit Part Number Breakers 024K 5 H3HK005H-01B 917166B None 8 H3HK008H-01B 917167B None 10 H3HK010H-01B 917168B 2 030K 5 H3HK005H-01B 917166B None 8 H3HK008H-01B 917167B 2

EK Series Electric Duct Heater OPTIONS & ACCESSORIES Specifi cations may be subject to change without notice. 0 25 50 75 100 125 150 175 200 0 2500 5000 7500 10000 12500 HEATER CAPACITY -kW AIRFLOW - CFM EK Series Heater Capacity SAFE OPERATING RANGE EK SERIES HEATER CAPACITY ELECTRIC DUCT HEATER SPECIFICATIONS Heater Type: Electric Duct .

Fleetguard Cross Reference Guide. OBSOLETED PARTS Obsolete Part # Replacement Part # Filter Part Type 3896692 N/A Coolant Heater 3896694 N/A Coolant Heater 3896697 N/A Coolant Heater 3896700 N/A Coolant Heater 3896706 N/A Coolant Heater 3305648 N/A Coolant Heater 3306006 N/A Coolant Heater 3306007 N/A Coolant Heater 3307046 N/A Coolant Heater

duct. 2) Secure electric heater by using metal screws through round flanges. 3) If necessary, install supports to maintain the electric heater. Slip-in type electric heater - Type I 1) Cut an opening in the duct. Allow ¼'' (6.3mm) more than the frame width ''D''. 2) Insert electric heater through the opening. 3) Secure electric .

This heater is equipped with a tip-over safety feature. Once the heater is tipped over, an internal switch will automatically shut the heater off. Once the heater is restored an upright position, the heater will reset. To continue operation, turn on the heater using the supplied remote control or the control panel on the heater.

Auxiliary Views Learning Objectives: 9Determine the need for an Auxiliary View. 9Construct each of the three classifications of Auxiliary Views. 9Identify the three classifi cations of Auxiliary Views. 9Define key terms. 9Cut Auxiliary sections. 9Understand and demonstrate the concept of Auxiliary Views on worksheets and CAD drawings. Drafting/CAD 1 - Mr. Mandl

5. Do not operate heater in ambient temperatures above 40 C (104 F). 6. Do not plug heater outlet with gloves, clothing, etc. or operate heater with louvers fully closed. 7. Explosion/Electric Shock Hazard. Disconnect heater from power supply before opening enclosures or servicing heater. Do not open if an explosive atmosphere is present. 8 .