jung pumpen compli residential technology sewage lifting stations

jung pumpen  compli sewage lifting stations compli – the right unit for every application Single units – compact and easy to install compli 300 E – the smallest and the lightest compli 400 – the first choice for the single-family house compli 500 – for those who want more This sewage lifting station is the smallest in our compli range. It has been specifically designed for the disposal of sewage from housing units such as basement dwellings. Due to its extremely compact tank dimensions and the numerous connection options, it is very versatile. Easy to operate, space-saving assembly, easy installation – it is no coincidence that the compli 400 is already an inherent part of the wastewater disposal system in more and more single-family houses. For larger wastewater flows, the compli 500 ensures reliable disposal with a larger tank capacity (115 l). As for all compli systems, the user-friendly controls guarantee dependable operation. Even in flood-prone areas this floodable system continues to dispose of domestic wastewater reliably and around the clock. Different motor ratings are available to suit the particular performance requirements.

Duplex units - Reliability x 2 compli 1000 – for reliability to the power of two compli 1200 – for more volume compli 1500/compli 2500 – to meet the greatest demands For several housing units or for commercial buildings such as hotels, pubs or restaurants, not only more power but also more reliability is required. The compli 1000 is therefore a duplex unit with two pumps on one tank. The compli 1200, with a tank capacity of 350 l, provides the ideal solution for several housing units, business establishments or hospitals. It is easy to install and maintain. For large industrial and municipal wastewater volumes or for the connection of entire streets or shopping centers, an especially large tank capacity is required. With a total volume of 1000 l and correspondingly powerful MultiStream pumps, the compli 2500 is the largest sewage lifting station. These pumps operate alternately, or work together during periods of peak load. The inlet at the back can be installed for variable height (560-700 mm) and be swivel-mounted (180 ). These systems are available with either two tanks (compli 2500) or one tank (compli 1500 with 500 l).

jung pumpen  compli sewage lifting stations Sewage lifting stations for special application compli 100, 500 and 1000 MultiCut compli 1200, 1400 und 1600 – in stainless steel The sewage lifting stations with the MultiCut cutting system were specially developed for the disposal of sewage from weekend cottages, houseboats, production halls and mobile sanitary units. The sewage lifting stations are specifically designed for large industrial and municipal wastewater volumes where special safety regulations have to be met, e. g. at underground stations, airports or parking decks. The MultiCut cutting system breaks up the common solid components found in domestic wastewater, enabling the use of smaller diameter pressure pipes.

compli sewage lifting stations Ready to plug-in · Powerful Your safety against back pressure. Numbers - Dates – Facts compli Dimensions h x w x d [mm] Tank capacity [l] Hmax [m] Qmax [m³/h] Free passage [mm] Inlet height [mm] Single units 300 E 445 x 525 x 525 50 10,5 29 50 180 400 445 x 650 x 595 64 7 48 70 180/250 500 600 x 835 x 690 115 20 76 70 variable 100 MultiCut 450 x 500 x 636 38 24 18 7 180/250 500 MultiCut 600 x 835 x 690 115 24 18 7 variable 1000 600 x 835 x 690 115 20 76 70 variable 1200 800 x 910 x 1010 350 20 76 70 560-700 1500 820 x 910 x 1610 500 22 100 70 / 100 700 2500 820 x 1955 x 1610 2 x 500 22 100 70 / 100 700 1000 MultiCut 600 x 835 x 690 115 24 18 1200 Stainless steel 880 x 770 x 1142 270 16 122 80 / 100 700 1400 Stainless steel 985 x 970 x 1375 540 16 122 80 / 100 800 1600 Stainless steel 985 x 970 x 1882 900 16 122 80 / 100 800 Duplex units 7 variable Stainless steel units

Height adjustable clamping flange compli 400 compli sewage lifting stations Convincing quality R eady to plug-in – no electrician required – also available with swing-type check valve Height adjustable clamping flange – quick adjustment to suit the wastwater situation on site Easy installation – due to flexible connection facilities Protection from moisture penetration – due to moisture sealed cable inlet Inlet-optimised tank base – less maintenance required Large cleaning opening – maintenance-friendly Guided float switch – for reliable, clearly defined switching points Easy-to-operate controls – clear layout of display and control elements LGA type tested and monitored All components „Made in Germany“ Further information regarding sewage lifting stations at www.jung-pumpen.de JUNG PUMPEN GmbH Industriestr. 4 – 6 · 33803 Steinhagen · Germany · Phone 49 5204 170 · Fax 49 5204 80 368 · info@jung-pumpen.de · www.jung-pumpen.de P 141-1.0-EN-1306 Image sources: Fotolia, Jung Pumpen GmbH PVC inlet sluice valve DN 100 or DN 150, with pipe sockets bonded in, for the time-saving and space-saving direct connection to the inlet clamping flange. Smooth running and quiet – due to cast support platform

JUNG PUMPEN GmbH industriestr. 4 - 6 · 33803 steinhagen · germany · phone 49 5204 170 · ax 49 5204 80 368 f · info@jung-pumpen.de · www.jung-pumpen.de Height adjustable clamping flange compli 400 PVC inlet sluice valve DN 100 or DN 150, with pipe sockets bonded in, for the time-saving and space-saving direct connection to the

Related Documents:

The sewage lifting stations compli 100, compli 500 and compli 1000 with MultiCut cutting system are uses especially for disposal in special objects, such as weekend cottages, houseboats, toilets in production halls or mobile sanitary facilities. The MultiCut cutting system enables

NG PPEN COMPLI 1500 / 2500 SEWAGE LIFTING STATIONS 1 compli 2500 compli 1500 D 204-4.4-EN-1607 APPLICATION The compli 1500 and 2500 tank systems have been designed for large industrial and communal wastewater volumes as well as for the connection of streets or other community effluent systems. In order to ensure a practical arrangement,

Mounting dimensions compli 2500 (mm) dimensions compli 1500 (mm) dimensions compli 2500 (mm) 43010-02 20779-03 43009-03 20778-04 In case of a chamber, plan 60 cm working space around all parts which have to be serviced. In case of a chamber, plan 60 cm working space around all parts which have to be serviced. Mounting dimensions compli 1500 (mm)

Speck-Kolbenpumpen KG Kauttenstr. 10 4060 Linz Österreich Tel. 0043 732 382066 Fax: 0043 732 382066-13 E-mail: info@speck-pumpen.at Internet: www.speck-pumpen.at Norwegen Speck-Triplex-Pumpen GmbH & Co. KG Walkenweg 41 33609 Bielefeld Germany Tel. 0049 521 970480 Fax: 0049 521 9704829 E-mail: info@speck-t

Morgan’s work is much akin to Jung’s Red Book, although Jung worked on the Red Book longer and with more conscious investment as to its outcome. Nevertheless if Jung’s Liber Novus depicts the rebirth of God by integrating God’s dark side, then Mo

Jung's oeuvre by posing some questions whose answers will indicate at least the main outlines of Jung's thought about the problem of evil. 1 hope, too, that this approach will prepare the reader to enter more deeply into the texts that follow and to watch Jung as he struggles with the problem of evil,

Edilcentro Wullschleger SA 6512 Giubiasco www.edilcentro.ch Elcotherm AG 7324 Vilters www.elco.ch EMB Pumpen AG 6512 Giubiasco www.emb-pumpen.ch Energia legno Svizzera 6670 Avegno www.energ

10. Efrain Balli Jr. 23. Madelynn Cortez 36. Alfredo Avila Lopez . 11 . Eligio Meudiola 24. George Garcia 37. Jesus Ruben Briseno . 12. Natalia Quintero Moreno 25. Diego Gonzalez Corpus 38. Juan E. Vela . NUMBER OF VOTES RECEIVED -49 . ELECTORS FOR TOM HOEFLING . 1. Tim Sedgwick 2. Dixie Sedgwick 3. Jared McCurrin 4. Jessica Kimberly Fagin 5. Andrew C. Sanders 6. Megan Sanders 7. Lynn Sanders .